Kinetics, Ca2+ dependence, and biophysical properties of integrin-mediated mechanical modulation of transmitter release from frog motor nerve terminals

Neurotransmitter release from frog motor nerve terminals is strongly modulated by change in muscle length. Over the physiological range, there is an approximately 10% increase in spontaneous and evoked release per 1% muscle stretch. Because many muscle fibers do not receive suprathreshold synaptic inputs at rest length, this stretch-induced enhancement of release constitutes a strong peripheral amplifier of the spinal stretch reflex. The stretch modulation of release is inhibited by peptides that block integrin binding of natural ligands. The modulation varies linearly with length, with a delay of no more than approximately 1-2 msec and is maintained constant at the new length. Moreover, the stretch modulation persists in a zero Ca2+ Ringer and, hence, is not dependent on Ca2+ influx through stretch activated channels. Eliminating transmembrane Ca2+ gradients and buffering intraterminal Ca2+ to approximately normal resting levels does not eliminate the modulation, suggesting that it is not the result of release of Ca2+ from internal stores. Finally, changes in temperature have no detectable effect on the kinetics of stretch-induced changes in endplate potential (EPP) amplitude or miniature EPP (mEPP) frequency. We conclude, therefore, that stretch does not act via second messenger pathways or a chemical modification of molecules involved in the release pathway. Instead, there is direct mechanical modulation of release. We postulate that tension on integrins in the presynaptic membrane is transduced mechanically into changes in the position or conformation of one or more molecules involved in neurotransmitter release, altering sensitivity to Ca2+ or the equilibrium for a critical reaction leading to vesicle fusion.

Non-NASA Center↗

Waste Water Brine Purification through Electrodialysis Ion Exchange

Reutilizing resources onboard the International Space Station (ISS) and for future deep space missions are critical for mission longevity and sustainability. Waste water brine produced from water recovery systems contain chemical species that could be processed into a potential fertilizer for future plant systems.Fertilizer production can be achieved through a process called electrodialysis ion exchange. Waste water containing inorganic salt components are fed through a series of ion exchange membranes to produce fertilizer (a phosphate rich stream), electrolysis-grade water, and other useful commodities.A test bed was constructed to conduct controlled experiments and an experimental design procedure developed to determine the feasibility of the process. Conductivity and pH probes were utilized to determine the ion concentration in each of the product streams, along with ion chromatography (IC) to define the exact concentration of each ion in every stream throughout the experiment. This is crucial in order to convey the effectiveness of ion removal from the incoming waste water stream.The waste water and electrolyte streams were prepared in the lab prior to experimentation. Additionally, the ion exchange membrane configurations were developed and Opto 22 data analysis software incorporated to conduct measurements in real time.Ions successfully diffused across their respective membranes into the concentrate, acid, and base streams. This resulted in pure water, a phosphate rich stream, and a separate anion/hydrogen and cation/hydroxide stream.

Hancock, Matthew L.↗

Quantitative image analysis of laminin immunoreactivity in skin basement membrane irradiated with 1 GeV/nucleon iron particles

We previously reported that laminin immunoreactivity in mouse mammary epithelium is altered shortly after whole-body irradiation with 0.8 Gy from 600 MeV/nucleon iron ions but is unaffected after exposure to sparsely ionizing radiation. This observation led us to propose that the effect could be due to protein damage from the high ionization density of the ion tracks. If so, we predicted that it would be evident soon after radiation exposure in basement membranes of other tissues and would depend on ion fluence. To test this hypothesis, we used immunofluorescence, confocal laser scanning microscopy, and image segmentation techniques to quantify changes in the basement membrane of mouse skin epidermis. At 1 h after exposure to 1 GeV/nucleon iron ions with doses from 0.03 to 1.6 Gy, neither the visual appearance nor the mean pixel intensity of laminin in the basement membrane of mouse dorsal skin epidermis was altered compared to sham-irradiated tissue. This result does not support the hypothesis that particle traversal directly affects laminin protein integrity. However, the mean pixel intensity of laminin immunoreactivity was significantly decreased in epidermal basement membrane at 48 and 96 h after exposure to 0.8 Gy 1 GeV/nucleon iron ions. We confirmed this effect with two additional antibodies raised against affinity-purified laminin 1 and the E3 fragment of the long-arm of laminin 1. In contrast, collagen type IV, another component of the basement membrane, was unaffected. Our studies demonstrate quantitatively that densely ionizing radiation elicits changes in skin microenvironments distinct from those induced by sparsely ionizing radiation. Such effects may might contribute to the carcinogenic potential of densely ionizing radiation by altering cellular signaling cascades mediated by cell-extracellular matrix interactions.

Non-NASA Center↗

Catalyst surfaces for the chromous/chromic redox couple

An electricity producing cell of the reduction-oxidation (REDOX) type is described. The cell is divided into two compartments by a membrane, each compartment containing a solid inert electrode. A ferrous/ferric couple in a chloride solution serves as a cathode fluid which is circulated through one of the compartments to produce a positive electric potential disposed therein. A chromic/chromous couple in a chloride solution serves as an anode fluid which is circulated through the second compartment to produce a negative potential on an electrode disposed therein. The electrode is an electrically conductive, inert material plated with copper, silver or gold. A thin layer of lead plates onto the copper, silver or gold layer when the cell is being charged, the lead ions being available from lead chloride which was added to the anode fluid. If the REDOX cell is then discharged, the current flows between the electrodes causing the lead to deplate from the negative electrode and the metal coating on the electrode will act as a catalyst to cause increased current density.

Giner, J. D.↗

Development of a Low-Power CO2 Removal and Compression System for Closed-Loop Air Revitalization in Future Spacecraft

The current CO2 removal technology of NASA is very energy intensive and contains many non-optimized subsystems. This paper discusses the design and prototype development of a two-stage CO2 removal and compression system that will utilize much less power than NASA s current CO2 removal technology. This integrated system contains a Nafion membrane followed by a residual water adsorber that performs the function of the desiccant beds in the four-bed molecular sieve (4BMS) system of the International Space Station (ISS). The membrane and the water adsorber are followed by a two-stage CO2 removal and compression subsystem that satisfies the operations of the CO2 adsorbent beds of the 4BMS aid the interface compressor for the Sabatier reactor connection. The two-stage compressor will utilize the principles of temperature-swing adsorption (TSA) compression technology for CO2 removal and compression. The similarities in operation and cycle times of the CO2 removal (first stage) and compression (second stage) operations will allow thermal coupling of the processes to maximize the efficiency of the system. In addition to the low-power advantage, this processor will maintain a lower CO2 concentration in the cabin than that can be achieved by the existing CO2 removal systems. The compact, consolidated, configuration of membrane gas dryer and CO2 separator and compressor will allow continuous recycling of humid air in the cabin and supply of compressed CO2 to the reduction unit for oxygen recovery. The device has potential application to the International Space Station and future, long duration, transit, and planetary missions.

Mulloth, Lila M.↗

Replaceable Sensor System for Bioreactor Monitoring

A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

Mayo, Mike↗

Delamination analysis of tapered laminated composites under tensile loading

A study was conducted to analyze tapered composite laminates under tensile loading. A tapered construction made of S2/SP250 glass/epoxy laminate was used to achieve a thickness reduction using three consecutive dropped plies over a distance of 60 ply thicknesses. The principle of minimum complementary potential energy was used to determine interlaminar stresses. The interlaminar peel stress distribution shows a higher tensile intensity at the taper/thin portion juncture. The total strain energy release rate is determined using a simplified membrane model. Results are compared with a finite element simulation.

Armanios, Erian A.↗

Ice nucleus concentrations measured during the 1975 Florida Area Cumulus Experiment /FACE/

Ice nuclei measurements were made aboard a cloud-base aircraft during the 1975 Florida Area Cumulus Experiment. Two techniques were used to obtain the ice nuclei concentrations; membranes were collected and analyzed using the NCAR membrane development chamber and continuous ice nuclei concentrations were obtained using the NCAR acoustical counter. Results showed that the membrane technique failed to effectively detect ice nuclei in this maritime tropical area. However, the concentrations recorded by the acoustical counter showed natural afternoon diurnal increases which may have ramifications on cloud development and seeding potential within the particular study area.

Wisniewski, J.↗

Optimal control of distributed parameter elastic systems

This paper presents an analytical solution to the Riccati equation for self-adjoint systems such as beams, plates, strings and membranes moving in space, and shows how the optimal control law can be implemented using the given solution. It is then shown that there always exists a self-adjoint operator describing the distribution of potential energy if the state space is appropriately augmented. A beam-like gravity-stabilized satellite moving in a circular orbit around the earth is used to illustrate the main results in this paper.

Juang, J.-N.↗

Summer 2015 Internship Abstract

Green fluorescent protein (GFP) visually shows the expression of proteins by fluorescing when exposed to certain wavelengths of light. The GFP in this experiment was used to identify cells actively releasing viruses. The experiment focused on the effect of microgravity on the GFP expression of Akata B-cells infected with Epstein Barr Virus (EBV). Two flasks were prepared with 30 million cells each and two bioreactors were prepared with 50 million cells each. All four cultures were incubated for 16 days and fed every four days. Cellometer readings were taken on the feeding days to find cell size, viability, and GFP expression. In addition, the cells were treated with Propodium monoazide (PMA) and run through real time PCR to determine viral load on the feeding days. On the International Space Station air samples are taken to analyze the bacterial and fungal organisms in the air. The Sartorius Portable Airport is being investigated for potential use on the ISS to analyze for viral content in the air. Multiple samples were taken around Johnson Space Center building 37 and in Clear Lake Pediatric Clinic. The filter used was the gelatin membrane filter and the DNA was extracted directly from the filter. The DNA was then run through real time PCR for Varicella Zoster Virus (VZV) and EBV as well as GAPDH to test for the presence of DNA. The results so far have shown low DNA yield and no positive results for VZV or EBV. Further inquiry involves accurately replicating an atmosphere with high viral load from saliva as would be found on the ISS to run the air sampler in. Another line of research is stress hormones that may be correlated to the reactivation of latent viruses. The stress hormones from saliva samples are analyzed rather than blood samples. The quantity found in saliva shows the quantity of the hormones actually attached to cells and causing a reaction, whereas in the blood the quantity of hormones is the total amount released to cause a reaction. The particular hormones tested for were cortisol, alpha-amylase, and DHEA. The DHEA was very high in the two control samples tested. Regularly, samples came into the lab from local clinics to be tested for various viruses. Saliva, blood, body scrapes, and tears were received from the clinics and then run for VZV, EBV, and Human Simplex Virus 1 (HSV-1) with the results then reported back to the clinician. Blood, saliva, and urine from astronauts were also tested for viruses and logged. In addition, several cell cultures were brought up and grown, including adherent Human Lung Fibroblast (HFL) cells infected with VZV, and Akata B-cells infected with EBV.

Smith, Courtney↗

Advanced radiator systems for space power

Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

Mattick, A. T.↗

Thermoelectric integrated membrane evaporation subsystem testing

An advanced preprototype Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) has been developed to provide high quality water recovery from various types of wastewater on extended duration space flights. The subsystem has undergone extensive wastewater processing testing, in order to evaluate its potential as an essential part of the Space Station Water Reclamation System. A discussion of the operating performance of the TIMES is presented in this paper, with special attention given to the water quality attained for a number of simulated Space Station wastewater feedstocks.

Dehner, Gerard F.↗

Dual Anion-Cation Crosslinked Poly(ionic liquid) Composite Membranes for Enhanced CO2 Separation

Herein, we propose a strategy of developing novel dual anionic-cationic crosslinked poly(IL)-IL composite membranes via a photopolymerization method for enhanced CO2 separations. These are the first examples of dually photopolymerized anionic-cationic poly(IL)-IL composite systems, in which the backbones of poly(IL)s feature both pendant anions and cations without any mobile counterions unlike poly(IL) reported so far in the literature. A new type of dual photopolymerizable anionic-cationic IL (DIL) monomer having methacrylate functional group tethered with highly delocalized sulfonimide anion (–SO2–N(-)–SO2–C7H7) and a vinylimidazolium counterion ([C4(vim)](+)) was successfully synthesized and photopolymerized with four distinct amounts of free IL with a structurally analogous cation ([C4(mim)][Tf2N]) and 20 wt% PEGDA crosslinker, offering novel composite matrices. Further, the structure-property relationships as well as gas separation behaviors of the four newly developed dual anioniccationic poly(IL)-IL composite membranes were extensively characterized by FT-IR, DSC, and XRD. All of the newly developed dual anionic-cationic poly(IL)-IL composite membranes displayed outstanding permselectivites for CO2/CH4, CO2/N2, and CO2/H2 gas pairs together with reasonable CO2 permeabilities. As a result, all the dual anionic-cationic poly(IL)-IL composite membranes outperformed the common poly(IL)-IL systems in the upper bound limit plots with best CO2 permeability of 40 barrer and CO2/CH4 permselectivity of 85. This study may pave a new platform to explore countless potential poly(IL)-IL composites for selective separation of CO2 from flue gas, natural gas, and syngas streams.

Irshad Kammakakam↗

Spacesuit Water Membrane Evaporator Integration with the ISS Extravehicular Mobility

NASA has developed a Solid Water Membrane Evaporation (SWME) to provide cooling for the next generation spacesuit. One approach to increasing the TRL of the system is to incorporate this hardware with the existing EMU. Several integration issues were addressed to support a potential demonstration of the SWME with the existing EMU. Systems analysis was performed to assess the capability of the SWME to maintain crewmember cooling and comfort as a replacement for sublimation. The materials of the SWME were reviewed to address compatibility with the EMU. Conceptual system placement and integration with the EMU via an EVA umbilical system to ensure crew mobility and Airlock egress were performed. A concept of operation for EVA use was identified that is compatible with the existing system. This concept is extensible as a means to provide cooling for the existing EMU. The cooling system of one of the EMUs on orbit has degraded, with the root cause undetermined. Should there be a common cause resident on ISS, this integration could provide a means to recover cooling capability for EMUs on orbit.

Margiott, Victoria↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Adaptation of ion beam technology to microfabrication of solid state devices and transducers

It was found that ion beam texturing of silicon surfaces can be used to increase the effective surface area of MOS capacitors. There is, however, a problem with low dielectric breakdown. Preliminary work was begun on the fabrication of ion implanted resistors on textured surfaces and the potential improvement of wire bond strength by bonding to a textured surface. In the area of ion beam sputtering, the techniques for sputtering PVC were developed. A PVC target containing valinomycin was used to sputter an ion selective membrane on a field effect transistor to form a potassium ion sensor.

Topich, J. A.↗

Characterizing the Superconducting-to-Normal Transition in Mo/Au Transition-Edge Sensor Bilayers

We are developing arrays of Mo/Au bilayer transition-edge sensors (TES's) for applications in future X-ray astronomy missions such as NASA's Constellation-X. The physical properties of the superconducting-to-normal transition in our TES bilayers, while often reproducible and characterized, are not well understood. The addition of normal metal features on top of the bilayer are found to change the shape and temperature of the transition, and they typically reduce the unexplained 'excess' noise. In order to understand and potentially optimize the properties of the transition, we have been studying the temperature, widths and current dependence of these transitions. We report on the characterization of devices both deposited on silicon substrates and suspended on thin silicon nitride membranes. This includes key device parameters such as the logarithmic resistance sensitivity with temperature alpha, and the logarithmic resistance sensitivity with current beta, of the phase-transition. We investigate alpha and beta as a function of current, both at fixed and varying bias points in the transition. Using Ginzburg-Landau theory for the current dependence of the superconducting transition temperature, we investigate the relationship between alpha and beta and compare our measured and theoretical estimates.

Smith, Stephen J.↗