Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Instrumentation development and testing of a wind turbine blade for sub-scale wake studies

Wind turbine blade aerodynamics and the resulting wake flow are complex, and wind tunnel testing of these flows can provide critical insight. The data from such tests are also valuable for validation of numerical models. For experiments using sub-scale turbines to be useful, the blade aerodynamics and wakes must exhibit the important features observed in utility-scale turbine flows. In this work, ~1 m blades designed to produce physics relevant to larger scale turbines were manufactured and affixed to an existing turbine. One of the blades was instrumented for blade surface pressure measurements. Time-dependent surface pressure measurements coupled with instantaneous measurements of the inflow with Cobra probes and the wake with particle image velocimetry allowed for characterization of the inflow, blade flow, and near wake. The results demonstrate that the instrumentation was effective in characterizing the blade loading and the flow field. For the one test case discussed in this paper, the measurements of inflow, blade loading, and wake properties facilitate understanding of the wake's behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics

The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.

Yadav, M. [University of California, Los Angeles, ↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

IPN Absorption Coefficients

The dataset contains aerosol light absorption and scattering coefficients measured by three single-wavelength Integrated Photoacoustic Nephelometers (IPN). The absorption coefficients were measured at 405, 721, and 1047 nm, while the scattering coefficients were measured at 405 and 721 nm. The single scattering albedo (SSA) at 405 and 721 nm were also calculated from the IPN measurements. The three IPNs shared a common inlet without impactor/cyclone in July; in August, a PM2.5 cyclone inlet was installed to reduce measurement noise and improve data quality. The 721-nm IPN experienced laser shutdown issues, causing missing of a large fraction of the 721-nm measurements, especially in July. As described before, the 721-nm laser issue was less frequent in August after the cyclone installation, improving the data completeness and quality. The IPN raw data were noisy, making identifying patterns and trends difficult; therefore, the hourly average data are recommended over the raw data. The hourly average data were cross-checked with the filter-based TAP and PSAP measurements, which showed that their patterns, trends, and peaks matched. However, due to the differences in working mechanisms and principles of the filter-based and photoacoustic particle-phase instruments, the IPN measurements are lower than the filter-based measurements despite that they have consistent patterns, trends, and peaks.

54 ENVIRONMENTAL SCIENCES↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of local-scale changes in greenhouse gas emissions in urban environments using micrometeorological methods and comparison to a high-resolution inventory

We used the Monin–Obukhov similarity theory (MOST) flux-variance relationship to estimate greenhouse gas (GHG) fluxes from high-precision mole fraction measurements at 3 instrumented urban communication towers over several years, demonstrating the ability of this method to detect and quantify changes in emissions. Depending on data availability, we used carbon dioxide (CO 2 ) and carbon monoxide (CO) measurements and/or tracer ratios to estimate fluxes at 1 urban site (Site 3) and 1 suburban site (Site 7) in Indianapolis, IN, USA, and 1 urban site (COM) in Los Angeles, CA, USA. We also compared the estimated fluxes of CO 2 from fossil fuel sources (CO 2 ff) at Sites 3 and 7 and the total CO 2 fluxes at Site 3 to 20 m, hourly resolution subdomains of the high-resolution CO 2 emissions inventory, Hestia, for the year 2020, introducing a new way to evaluate emissions inventories at small spatial and temporal scales. Using the flux-variance relationship, we detected and quantified abrupt decreases in CO and CO 2 fluxes at Site 3 and COM in April 2020, coinciding with the stay-at-home order due to COVID-19 pandemic, as well as abrupt decreases in CO and CO 2 fluxes at Site 3 in July 2018 coinciding with a highway closure next to the site. The Hestia emissions inventory detected a decrease in emissions in April 2020 at Sites 3 and 7, but this decrease differed in magnitude from those detected in the atmospheric estimates. Seasonal trends in emissions are similar between Hestia and the atmospheric estimates at Site 7. We use differences in seasonal and spatial trends between the flux estimation methods to identify potential sources of uncertainty in both the atmospheric and inventory methods. The results from this study show that the flux-variance estimation method is a useful tool to monitor local-scale emissions and evaluate high-resolution emissions inventories.

Carbon dioxide↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Illumination of Thunderclouds by Lightning: 2. The Effect of GLM Instrument Threshold on Detection and Clustering

Abstract Lightning is measured from space using optical instruments that detect transient changes in the illumination of the cloud top. How much of the flash (if any) is recorded by the instrument depends on the instrument detection threshold. NOAA's Geostationary Lightning Mapper (GLM) employs a dynamic threshold that varies across the imaging array and changes over time. This causes flashes in certain regions and at night to be recorded in greater detail than other flashes, and threshold inconsistencies will impose biases on all levels of GLM data products. In this study, we quantify the impact of the varying GLM threshold on event/group/flash detection, flash clustering, and gridded product generation by imposing artificial thresholds on the event data taken from a thunderstorm with a low instrument threshold (∼0.7 fJ). We find that even modest increases in threshold severely impact event (60% loss by 2 fJ, 90% loss by 10 fJ) and group (25% loss by 2 fJ, 81% loss by 10 fJ) detection by suppressing faint illumination of the cloud top from weak sources and scattering. Flash detection is impacted less by threshold increases (4% loss by 2 fJ), but reductions are still significant at higher thresholds (35% loss by 10 fJ, or 44% if single‐group flashes are removed). Undetected pulses cause individual flashes to be split and severely impact the construction of gridded products. All of these factors complicate the interpretation of GLM data, particularly when trended over time under a changing threshold.

54 ENVIRONMENTAL SCIENCES↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

INL Alpha Background Radiation Study

Radiological emergencies that result in the dispersion of radioactive materials to the environment require the deployment of field monitoring teams to determine the quantity and location of the dispersed radioactive material. This information is utilized by the emergency operations center to aid in determining the appropriate protective action recommendations. The background alpha emission rates from normal environmental surfaces of soil, concrete and asphalt as measured by portable instrumentation used by field monitoring teams are not well documented. Idaho National Laboratory conducted a study of the alpha radiation background levels of the environmental surfaces in eastern Idaho to determine the normal background rates. Results for normal dry surfaces and those wetted by precipitation were measured and reported.

61 RADIATION PROTECTION AND DOSIMETRY↗