PHYSICAL MEASUREMENTS AND DATA PROCESSING
Instrumentation, calibration and data processing of tiros meteorological satellites
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Instrumentation, calibration and data processing of tiros meteorological satellites
Microwave radiometer analysis of sea water, salines, quartz sand, and crushed limestone
Microwave radiometer analysis of sea water, salines, quartz sand, and crushed limestone - sea water plots and printout
Microwave radiometer analysis of sea water, salines, quartz sand, and crushed limestone - quartz sand, salines, and crushed limestone plots and printouts
Absorption by Lorentz, Doppler, and Voight lines are compared for a range of atmospheric parameters. It is found that, for the intermediate path lengths, the use of the combined Lorentz-Doppler (Voight) profile is essential in calculating the atmospheric transmittance. A brief review of band models, to approximate the absorption over certain frequency interval, is presented. Expressions for total radiative energy emergent from the atmosphere are given which, with appropriate line or band models, can be used to reduce the data obtained from radiation measurement by an instrument mounted on an aircraft or a satellite. By employing the inversion procedure, the concentration of atmospheric pollutants can be obtained from the measured data.
Explore the source record for details and available documents.
The author has identified the following significant results. Measurements made at 13.9 GHz with the radar scatterometer on Skylab have been combined to produce median curves of the variation of scattering coefficient with angle of incidence out to 45 deg. Because of the large number of observations, and the large area averaged for each measured data point, these curves may be used as a new design base for radars. A reasonably good fit at larger angles is obtained using the theoretical expression based on an exponential height correlation function and also using Lambert's law. For angles under 10 deg, a different fit based on the exponential correlation function, and a fit based on geometric optics expressions are both reasonably valid.
The role of various infrared techniques in measurements of trace gases in the stratosphere were surveyed. Particular emphasis was placed on the role of instruments exhibiting ultrahigh resolution (i.e., less than or equal to 0.00/cm) such as laser heterodyne spectrometers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Two signal processing techniques are discussed that improve the accuracy of a microwave holographic measurement by removing unwanted signals from the aperture distribution: pattern simulation and subtraction, and time domain filtering. Pattern simulation and subtraction involves modeling unwanted scattering mechanisms and then removing them from the measured far-field data. Measurements taken on a focal point geometry and a Cassegrain geometry at 11 GHz were processed by the holographic analysis system. Pattern simulation and subtraction was applied to both geometries. Surface deformation profiles generated for the Cassegrain antenna by this system were compared to an optical measurement of the main reflector surface.
Explore the source record for details and available documents.
Low-altitude windshear is the leading weather-related cause of fatal aviation accidents in the U.S. Since 1964, there have been 26 accidents attributed to windshear resulting in over 500 fatalities. Low-altitude windshear can take several forms, including macroscopic forms such as cold-warm gustfronts down to the small, intense downdrafts known as microbursts. Microbursts are particularly dangerous and difficult to detect due to their small size, short duration, and occurrence under both heavy precipitation and virtually dry conditions. For these reasons, the real-time detection of windshear hazards is a very active field of research. Also, the advent of digital ground-to-air datalinks and electronic flight instrumentation opens up many options for implementation of windshear alerts in the terminal area environment. Study is required to determine the best content, format, timing, and cockpit presentation of windshear alerts in the modern ATC environment to best inform the flight crew without significantly increasing crew workload.
This document establishes the functional requirements of the Galileo Orbitor plasma wave subsystem (PWS) which is used to investigate electric and magnetic waves in space plasmas.
The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to assure the end product meets specifications and customer requirements. Measuring devices, often called measuring and test equipments (MTE), provide the evidence of product conformity to the prescribed requirements. Therefore the processes which employ MTE can become a weak link to the overall QMS if proper attention is not given to development and execution of these processes. Traditionally, calibration of MTE is given more focus in industry standards and process control efforts than the equally important proper usage of the same equipment. It is a common complaint of calibration laboratory personnel that MTE users are only interested in "a sticker." If the QMS requires the MTE "to demonstrate conformity of the product," then the quality of the measurement process must be adequate for the task. This leads to an ad hoc definition; measurement assurance is a discipline that assures that all processes, activities, environments, standards, and procedures involved in making a measurement produce a result that can be rigorously evaluated for validity and accuracy. To evaluate that the existing measurement processes are providing an adequate level of quality to support the decisions based upon this measurement data, an understanding of measurement assurance basics is essential. This topic is complimentary to the calibration standard, ANSI/NCSL Z540.3-2006, which targets the calibration of MTE at the organizational level. This paper will discuss general measurement assurance when MTE is used to provide evidence of product conformity, therefore the target audience of this paper is end item users of MTE. A central focus of the paper will be the verification of tolerances and the associated risks, so calibration professionals may find the paper useful in communication with their customers, MTE users.
In order to understand the risk posed to astronauts by electric arc-generated particles, high-speed, high-resolution, quantitative thermal imaging was needed. The measurement requirements appeared to be beyond the capabilities of commercial thermal imaging systems, but the particles were known to have a significant amount of emission in the visible spectrum. This led to the use of commercially available, high-speed video cameras as imaging radiometers. Measured particle temperatures were consistent with predictions and other measurement data. The optical temperature measurement method, results, and conclusions are presented, along with recommendations for further work.
Automatic incorporation of non-destructive evaluation (NDE) data into CAD and finite element (FE) models for structural analysis is essential for accurate residual-life and strength analyses of composite structures. Currently, two significant but independent challenges exist for incorporating NDE data in such analyses: interpretation of the NDE signals to locate and characterize the structural defects and the incorporation of that information into structural analysis tools. The first challenge will be addressed through linear inversion of calculated synthetic responses generated by a simulation engine to evaluate flaw size, location, and other characteristics. The second challenge will be addressed by building on prior and parallel defect modeling efforts to integrate suitable flaw models into the CAD/finite-element representation of a specimen. Ultrasonic NDE information is usually represented using C-Scans of time-of-flight or intensity information. Other modalities such as thermography and computed tomography (CT) could also be used to characterize the structure. This information will first be projected into material coordinates and then aligned with the specimen’s finite element mesh. The NDE data can then be incorporated by inserting flaw geometry into the CAD and FE analysis model and automatic modification of local material properties and boundary conditions. This process will enable the use of structural analysis tools even for practical modalities such as ultrasound and thermography which may not directly give accurate-enough geometric information to fully define the flaw. The full flaw characteristics will be inferred using prior expert and modeling knowledge to categorize flaw signatures. Outputs for this project will include demonstrated methods for creating structural analysis geometric models that incorporate flaw characterization information; these models can then be used directly in popular commercial FEA software. In addition, the primary deliverable for the project will include a software that will be able to automatically incorporate different kinds of flaws into an existing FE models. The models will be generated in standard file formats to enable direct import into the analysis software.