Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “materials forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Application of the 226 Ra– 230 Th– 234 U and 227 Ac– 231 Pa– 235 U radiochronometers to uranium certified reference materials

Uranium certified reference materials (CRM) issued by New Brunswick Laboratory were subjected to dating using four independent uranium-series radiochronometers. In all cases, there was acceptable agreement between the model ages calculated using the 231 Pa– 235 U, 230 Th– 234 U, 227 Ac– 235 U or 226 Ra– 234 U radiochronometers and either the certified 230 Th– 234 U model date (CRM 125-A and CRM U630), or the known purification date (CRM U050 and CRM U100). Finally, the agreement between the four independent radiochronometers establishes these uranium certified reference materials as ideal informal standards for validating dating techniques utilized in nuclear forensic investigations in the absence of standards with certified model ages for multiple radiochronometers.

226Ra↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NIST Efforts to Quality-Assure Gunpowder Measurements

In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

MacCrehan, William A.↗

Elementary! A Nuclear Forensics Workshop Teaches Vital Skills to International Practitioners

The article describes the Nuclear Forensics Workshop sponsored by the International Atomic Energy Agency (IAEA), the Office of Nonproliferation and International Security (NIS) and hosted by Pacific Northwest National Laboratory October 28-November 8, 2013 in Richland,Washington. Twenty-six participants from 10 countries attended the workshop. Experts from from Los Alamos, Lawrence Livermore, and Pacific Northwest national laboratories collaborated with an internationally recognized cadre of experts from the U.S. Department of Homeland Security and other U.S. agencies, IAEA, the Australian Nuclear Science and Technology Organisation, the United Kingdom Atomic Weapons Establishment (AWE), and the European Union Joint Research Center Institute for Transuranium Elements, to train practitioners in basic methodologies of nuclear forensic examinations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Overview of Algorithms for Using Particle Morphology in Pre-Detonation Nuclear Forensics

A major goal in pre-detonation nuclear forensics is to infer the processing conditions and/or facility type that produced radiological material. This review paper focuses on analyses of particle size, shape, texture (“morphology”) signatures that could provide information on the provenance of interdicted materials. For example, uranium ore concentrates (UOC or yellowcake) include ammonium diuranate (ADU), ammonium uranyl carbonate (AUC), sodium diuranate (SDU), magnesium diuranate (MDU), and others, each prepared using different salts to precipitate U from solution. Once precipitated, UOCs are often dried and calcined to remove adsorbed water. The products can be allowed to react further, forming uranium oxides UO3, U3O8, or UO2 powders, whose surface morphology can be indicative of precipitation and/or calcination conditions used in their production. This review paper describes statistical issues and approaches in using quantitative analyses of measurements such as particle size and shape to infer production conditions. Statistical topics include multivariate t tests (Hotelling’s T 2 ), design of experiments, and several machine learning (ML) options including decision trees, learning vector quantization neural networks, mixture discriminant analysis, and approximate Bayesian computation (ABC). ABC is emphasized as an attractive option to include the effects of model uncertainty in the selected and fitted forward model used for inferring processing conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A new TEVA-DGA chromatography procedure to separate Pu, Am, and Np from bulk U materials

Trace actinides present within uranium (U) material are diagnostic signatures of U processing history. For example, the emplacement of U material within the high neutron-flux environment of a nuclear reactor can cause neutron capture of U to form 241-plutonium ( 241 Pu). Plutonium-241 then decays to progeny isotopes 241-americium ( 241 Am) and 237-neptunium ( 237 Np); therefore, the presence and relative abundances of these trace actinides is indicative of the material’s production history and intended employment (Mayer et al., 2013). During a pre-detonation nuclear forensics investigation, measurement of trace actinide 241 Pu, 241 Am, and 237 Np concentrations by an analytical laboratory may be requested. However, chemically purifying these elements from bulk U is a challenging and involved procedure requiring several sequential chromatography columns across 4+ days. To expedite Pu-Am-Np separation from bulk U material, and to improve the yield recovery of these elements, this DHS Postdoc Fellowship has worked to create a new chromatography separation chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A probabilistic inverse prediction method for predicting plutonium processing conditions

In the past decade, nuclear chemists and physicists have been conducting studies to investigate the signatures associated with the production of special nuclear material (SNM). In particular, these studies aim to determine how various processing parameters impact the physical, chemical, and morphological properties of the resulting special nuclear material. By better understanding how these properties relate to the processing parameters, scientists can better contribute to nuclear forensics investigations by quantifying their results and ultimately shortening the forensic timeline. This paper aims to statistically analyze and quantify the relationships that exist between the processing conditions used in these experiments and the various properties of the nuclear end-product by invoking inverse methods. In particular, these methods make use of Bayesian Adaptive Spline Surface models in conjunction with Bayesian model calibration techniques to probabilistically determine processing conditions as an inverse function of morphological characteristics. Not only does the model presented in this paper allow for providing point estimates of a sample of special nuclear material, but it also incorporates uncertainty into these predictions. This model proves sufficient for predicting processing conditions within a standard deviation of the observed processing conditions, on average, provides a solid foundation for future work in predicting processing conditions of particles of special nuclear material using only their observed morphological characteristics, and is generalizable to the field of chemometrics for applicability across different materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis of Actinide Materials for the Study of Basic Actinide Science and Rapid Separation of Fission Products

This dissertation covers several distinct projects relating to the fields of nuclear forensics and basic actinide science. Post-detonation nuclear forensics, in particular, the study of fission products resulting from a nuclear device to determine device attributes and information, often depends on the comparison of fission products to a library of known ratios. The expansion of this library is imperative as technology advances. Rapid separation of fission products from a target material, without the need to dissolve the target, is an important technique to develop to improve the library and provide a means to develop samples and standards for testing separations. Several materials were studied as a proof-of-concept that fission products can be extracted from a solid target, including microparticulate (< 10 μm diameter) dUO 2 , porous metal organic frameworks (MOFs) synthesized from depleted uranium (dU), and other organicbased frameworks containing dU. The targets were irradiated with fast neutrons from one of two different neutron sources, contacted with dilute acids to facilitate the separation of fission products, and analyzed via gamma spectroscopy for separation yields. The results indicate that smaller particle sizes of dUO 2 in contact with the secondary matrix KBr yield higher separation yields than particles without a secondary matrix. It was also discovered that using 0.1 M HNO 3 as a contact acid leads to the dissolution of the target material. Lower concentrations of acid were used for future experiments. In the case of the MOFs, a larger pore size in the framework leads to higher separation yields when contacted with 0.01 M HNO 3 . Different types of frameworks also yield different results.

36 MATERIALS SCIENCE↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Round-robin 230 Th– 234 U age dating of bulk uranium for nuclear forensics

In an inter-laboratory measurement comparison study, four laboratories determined 230 Th– 234 U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. As a result, these model ages are concordant with to slightly older than the known production age of NBL U050.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National Nuclear Materials Archive (NNMA) - Specimen Selection and Sampling at the Y-12 National Security Complex

Y-12 has made significant progress in FY21 towards National Nuclear Materials Archive (NNMA) program objectives related to the identification, nomination, sampling, sub-sampling and shipment of NNMA materials. Y-12 efforts in FY22 and beyond are anticipated to transition away from material identification and nomination to an emphasis on sampling/sub-sampling and long-term storage of NNMA specimens. Long-term storage efforts will also involve more emphasis on insuring that the nuclear forensics value of NNMA items is guaranteed through appropriate preservation processes.

36 MATERIALS SCIENCE↗

Innovative high-temperature ammonium bifluoride fusion and rapid analysis of elements with nuclear forensic value

High-temperature ammonium bifluoride (ABF) fusions were evaluated for potential use in rapid dissolution of post-detonation nuclear debris. The ABF fusion was carried out in a Pt crucible which allowed evaluation of higher fusion and evaporation temperatures. The high-temperature ABF fusion dissolution method was evaluated using geological reference materials: USGS QLO-1a Quartz Latite, USGS SDC-1 Mica Schist, and NIST 278 Obsidian Rock. The optimized dissolution method involved a 10 min fusion at 540 °C, a 5 min reflux in 8 M HNO 3 , an evaporation at 300 °C and final dilution into 45 mL of 2% (v/v) HNO3. The final solution was filtered after heating at 105 °C using a hotblock. This dissolution method was simple, requiring only a hotplate or hotblock, filtered samples were available for ICP-MS analysis or radiochemical separation within 150 min, and was found to have high (>90%) recovery for many isotopes of interest in nuclear forensics applications. U and Pu in the dissolved material was separated using TEVA and UTEVA extraction chromatography columns, a process which resulted in >90% recovery. An irradiated U tracer was spiked into the material prior to dissolution and analyzed for recovery of major fission products and 239Np. The monitored radionuclides had recoveries of greater than 90%, except for the volatile radioiodine isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

Nuclear Forensics

Explore the source record for details and available documents.

Nuclear science and engineering - Nuclear fuel cyc↗