Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array

The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the cosmic microwave background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be $r_{0.05}<0.06$ at 95% c.l., further improvements on this upper limit are hindered by polarized galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: $G, T_c, R_n, P_{sat}$, and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07×10 -17 W/$\sqrt{Hz}$, including an anticipated photon noise level 1.54×10 -17 W/$\sqrt{Hz}$.

47 OTHER INSTRUMENTATION↗

Insights into Methodologies and Operational Details of Resource Adequacy Assessment: A Case Study with Application to a Broader Flexibility Framework

Assessing and maintaining resource adequacy (RA) is a core pillar of power systems. However, recent changes in the physical makeup of these systems and the conditions under which these systems must operate have yielded a renewed interest in the methods, metrics, and assumptions that underpin RA assessments. In this paper, we systematically explore a wide range of RA modeling dimensions, including: the objective function and level of operational detail in the underlying model formulation; the quantity (look-ahead) and quality (accuracy) of data that is available for making operational decisions within those models; and the physical configuration of solar photovoltaics (PV) with battery storage hybrid resources. We apply a set of probabilistic RA tools and production cost modeling tools to a realistic test system based loosely on a future Electric Reliability Council of Texas power system dominated by solar PV resources. Under the assumptions of our system and models, we find that multi-stage probabilistic assessments may provide a more robust evaluation of RA by capturing a wider range of operational and system interactions, but this comes at a computational cost of 1-2 orders of magnitude longer run time depending on the specific configuration. In addition, the information on thermal generator availability impacts RA performance by an order of magnitude more than solar resource forecasts, which is driven by the comparatively larger magnitude of thermal outages than solar forecast errors within our test system. Lastly, the flexibility provided by hybrid and other resources can help reduce system load-shedding event frequencies and enable the system to be more robust to inaccurate forecast information, and alternative hybrid inverter sizes can impact RA levels by 1-2 orders of magnitude. Our results point to the importance of a broader flexibility framework to describe the interaction between (1) flexibility "supply" from both physical resource capabilities and operational constraints considered in the modeling, and (2) flexibility "demand" from forecast errors, thermal generator outages, and other sources of uncertainty, as well as their RA impacts. Results are likely sensitive to the system buildout explored; future work could consider additional system configurations and conditions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

A Comfort Model Simplification for Tight Integration with Grid Service Optimizations

Localized generation, storage, and intelligent power electronics are increasingly being integrated into building. The excess storage, thermal, and generation capacity can be used to develop new markets for ancillary services such as peak reduction, voltage and frequency support, or load flattening. Widespread participation in these markets will make the power grid more resilient. However, widespread participation in these markets will require a simple and intuitive control over the excess capacity by the building occupants. Most importantly for adopting these technologies, participation in these markets should not require sacrificing occupant comfort. Many of the proposed control and optimization technologies for supplying the ancillary services do not explicitly incorporate occupant comfort into their models and when they do, generally utilize a rigid constraint on the indoor air temperature set a priori. This reduces flexibility in using excess thermal capacity. It also cannot take into account uncertainties in local factors that affect thermal comfort such as clothing insulation or relative humidity. In this paper we present and justify some assumptions that simplify the standard predictors of thermal comfort. We also develop a regression model of the thermal comfort that is linear with respect to the indoor air temperature. Next we develop the concept of thermal comfort variation that eliminates the dependence of the thermal comfort on uncertain thermal comfort factors. Then, we present a quadratic program utilizing the thermal comfort variation in both the objective function and as a constraint. Finally, we show the results of a time-of-use cost optimization that utilizes the simplified thermal comfort model.

Melin, Alexander↗

Power Hardware-In-the-Loop Hydropower and Ultracapacitor Hybrid Testbed

Widespread deployment of a proof-of-concept technological solution for power system performance improvement can be accelerated through onsite demonstration and pilot projects. Digital real-time simulation with power hardware-in-the-loop in controlled lab environment is the precursor to de-risk the timely and efficient execution of field demonstration and pilot projects. However, the detailed process of development, characterization, and calibration of such high fidelity simulation testbed needs to be documented in a reproducible and publicly accessible manner to leverage across broader research and development communities. This paper presents such a laboratory testbed to study black start capability of a run-of-river hydro + ultracapacitor hybrid system. Beside the high-fidelity model of the islanded grid with hydropower unit, the testbed includes the energy storage, grid following inverter, and grid emulator hardware. Several aspects such as storage characterization, control and various parameter settings necessary to capture frequency transients during load restoration are described in a comprehensive manner, which led to an effective and timely execution of black start field demonstration with an actual hydropower plant.

13 HYDRO ENERGY↗

Washington Clean Energy Fund: Energy Storage System Consolidated Performance Test Results

This report provides an overview of test results for four energy storage systems funded under the Washington Clean Energy Fund deployed at three utilities in Washington State. Integration of energy storage into the U.S. grid has been gathering momentum across the industry, especially as penetration of power generated by renewable resources increases. Several states have storage procurement targets to deal with a variety of issues, such as afternoon total system load ramping requirements, frequency regulation/control, and integration power generated from by renewable resources. This report presents the performance test results for battery energy storage systems (BESS) funded by the Washington Clean Energy Fund (CEF) 1 Program ($\$$14.3 million in state funding supporting a total investment of $\$$43 million). For each project, the technical attributes of the BESS were tested, defined, and evaluated in detail. These projects were funded jointly by Avista, the Snohomish Public Utility District (SnoPUD), Puget Sound Energy (PSE), the Washington CEF, and the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting rotor rotation noise

Program uses multiple sets of measured or hypothetical high-frequency blade-loading coefficients to calculate rotational noise of stationary helicopter rotors.

Hosier, R. N.↗

Preliminary design study of an alternate heat source assembly for a Brayton isotope power system

Results are presented for a study of the preliminary design of an alternate heat source assembly (HSA) intended for use in the Brayton isotope power system (BIPS). The BIPS converts thermal energy emitted by a radioactive heat source into electrical energy by means of a closed Brayton cycle. A heat source heat exchanger configuration was selected and optimized. The design consists of a 10 turn helically wound Hastelloy X tube. Thermal analyses were performed for various operating conditions to ensure that post impact containment shell (PICS) temperatures remain within specified limits. These limits are essentially satisfied for all modes of operation except for the emergency cooling system for which the PICS temperatures are too high. Neon was found to be the best choice for a fill gas for auxiliary cooling system operation. Low cycle fatigue life, natural frequency, and dynamic loading requirements can be met with minor modifications to the existing HSA.

Strumpf, H. J.↗

Vibration of prestressed periodic lattice structures

Equations are developed for vibration of general lattice structures that have repetitive geometry. The method of solution is an extension of a previous paper for buckling of similar structures. The theory is based on representing each member of the structure with the exact dynamic stiffness matrix and taking advantage of the repetitive geometry to obtain an eigenvalue problem involving the degrees-of-freedom at a single node in the lattice. Results are given for shell-and beam-like lattice structures and for rings stiffened with tension cables and a central mast. The variation of frequency with external loading and the effect of local member vibration on overall modes is shown.

Anderson, M. S.↗

Orientation and origin of ridges in the Lunae Palus - Coprates region of Mars

By analogy with lunar mare ridges and from morphologic evidence, such as the smooth slopes of arches, the wrinkle ridges of the Tharsis region of Mars are interpreted to primarily result from compressional folding of the volcanic plains. Comparison of ridge orientations in the Lunae Palus and Coprates quadrangles to a Tharsis center indicates that more than 60% of the total length of ridges is orthogonal to a normal from this center. Graben trends in surrounding terrain indicate that nonorthogonal ridges are not significantly affected by regional scale structures. Comparison of orthogonal and nonorthogonal ridge frequencies suggests that loading due to the Tharsis plateau produced compressional features as far as 4000 km from the center of the load, and that additional compressional stress sources are needed to account for ridge systems at greater distances from the Tharsis plateau.

Maxwell, T. A.↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study, volume 1

An active controls technology (ACT) system architecture was selected based on current technology system elements and optimal control theory was evaluated for use in analyzing and synthesizing ACT multiple control laws. The system selected employs three redundant computers to implement all of the ACT functions, four redundant smaller computers to implement the crucial pitch-augmented stability function, and a separate maintenance and display computer. The reliability objective of probability of crucial function failure of less than 1 x 10 to the -9th power per flight of 1 hr can be met with current technology system components, if the software is assumed fault free and coverage approaching 1.0 can be provided. The optimal control theory approach to ACT control law synthesis yielded comparable control law performance much more systematically and directly than the classical s-domain approach. The ACT control law performance, although somewhat degraded by the inclusion of representative nonlinearities, remained quite effective. Certain high-frequency gust-load alleviation functions may require increased surface rate capability.

Hanks, G. W.↗

NASTRAN forced vibration analysis of rotating cyclic structures

Theoretical aspects of a new capability, developed and added to the general purpose finite element program NASTRAN Level 17.7, to conduct forced vibration analysis of turned cyclic structures rotating about their axis of symmetry, are presented. The effects of Coriolis and centripetal accelerations as well as those due to the translational acceleration of the axis of rotation, are included. The equations of motion are first derived for an arbitrary grid point of the cyclic sector finite element model and then extended for the complete model. The equations are solved by four principal steps: (1) transformation of applied loads at frequency-dependent circumferential harmonic components; (2) application of circumferential harmonic-dependent intersegment compatibility constraints; (3) solution of frequency-dependent circumferential harmonic components of displacements; and (4) recovery of frequency-dependent response in various segments of the total structure. Five interrelated examples are presented to illustrate the various features of the development.

Elchuri, V.↗

Conceptual design for scaled truss antenna flight experiment

The conceptual design for a scaled truss antenna structures experiment program (STASEP) is presented. The hardware analysis of the scaled truss antenna structure (STAS) was performed by interactive design and evaluation of advanced spacecraft (IDEAS) computer aided, interactive, design and analysis program. Four STAS's were designed to be launched by the Shuttle, tested by using the space technology experiments platform (STEP) and space transportation system (STS), and then free flown in short lifetime orbits. Data were gathered on deployment, structural characteristics, geometric accuracies, thermal performance, and drag and lifetime as an orbiting spacecraft. Structural and thermal properties were determined for the STAS, including mass properties, thermal loading, structural natural frequencies, and mode shapes. The necessary analysis, scaling, and ground testing are discussed.

Lee, W. H.↗

Transient vibration test criteria for spacecraft hardware

Transient vibration test criteria, developed for spacecraft hardware, provide a test rationale to verify the capability of the hardware to withstand the low and mid frequency transient vibration environments induced by launch vehicle events. A test method, consisting of a series of discrete frequency, limited cycle, modulated sine wave pulses, was developed to avoid the slow swept sine drawbacks, yet provide a repeatable test that would excite all frequencies. The shape of the waveform is that of the classic response of the mass of a one degree of freedom system when it is base-excited by an exponentially decayed sine wave transient. Criteria were developed to define pulse amplitudes, shapes, and center frequencies from spacecraft loads analyses. Test tolerance criteria were also developed and specified. The transient vibration test criteria were implemented on spacecraft flight hardware and provided a more realistic test simulation (i.e., less conservative) for qualification of spacecraft hardware without risk of undertest.

Kern, D. L.↗

Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS). Phase 1: Users handbook

The EASY5 macro component models developed for the spacecraft power system simulation are described. A brief explanation about how to use the macro components with the EASY5 Standard Components to build a specific system is given through an example. The macro components are ordered according to the following functional group: converter power stage models, compensator models, current-feedback models, constant frequency control models, load models, solar array models, and shunt regulator models. Major equations, a circuit model, and a program listing are provided for each macro component.

Kim, S.↗