Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relaxation dynamics of deformed polymer nanocomposites as revealed by small-angle scattering and rheology

Here, the relaxation dynamics of polystyrene (PS)/silica nanocomposites after a large step deformation are studied by a combination of small-angle scattering techniques and rheology. Small-angle X-ray scattering measurements and rheology show clear signatures of nanoparticle aggregation that enhances the mechanical properties of the polymer nanocomposites (PNCs) in the linear viscoelastic regime and during the initial phase of stress relaxation along with accelerated relaxation dynamics. Small-angle neutron scattering experiments under the zero-average-contrast condition reveal, however, smaller structural anisotropy in the PNCs than that in the neat polymer matrix, as well as accelerated anisotropy relaxation. In addition, the degrees of anisotropy reduction and relaxation dynamics acceleration increase with increasing nanoparticle loading. These results are in sharp contrast to the prevailing viewpoint of enhanced molecular deformation as the main mechanism for the mechanical enhancement in PNCs. Furthermore, the observed acceleration of stress relaxation and reduction in structural anisotropy point to two types of nonlinear effects in the relaxation dynamics of PNCs at large deformation.

36 MATERIALS SCIENCE↗

Photoreactive Capture and Conversion of Dilute Carbon Dioxide into Synthetic Natural Gas

This study introduces a photoreactive system that integrates the capture of dilute CO 2 streams with their catalytic conversion to synthetic natural gas (CH 4 ), utilizing a Ru nanoparticle (NP)-doped TiO 2 composite loaded with linear polyethylenimine (L-PEI) and enhanced with plasmonic titanium nitride (TiN). This light-driven approach mitigates challenges that have plagued traditional thermal reactive carbon capture (RCC) methods, such as CO 2 slip and amine degradation. We demonstrate that L-PEI enables stable CO 2 capture and conversion, achieving ~70% conversion of captured CO 2 to CH 4 across multiple reaction cycles using nonflammable forming gas (~5% H 2 ) as the reductant. In contrast, branched PEI (B-PEI)-loaded composites exhibited significant catalyst deactivation after several RCC cycles. Scanning transmission electron microscopy (STEM) imaging confirms that significant sintering of the Ru NPs occur in the B-PEI sample under RCC conditions, whereas their size remains stable in more rigid L-PEI composites. Technoeconomic analysis (TEA) estimates that CH 4 production using this system could cost less than $\$$5/kg based on current electrocatalytic H 2 prices. These results represent one of the most promising demonstrations of amine-based RCC employing dilute CO 2 sources to date.

36 MATERIALS SCIENCE↗

Evaluation of Composite Materials for Heliostat Cost Reduction

This is an evaluation of composite materials for heliostat cost reduction, including the motivation, reference heliostat model, characteristic wind loads, selection of pultruded structural composites, and technoeconomic analysis using equivalent deformation.

composite materials↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Micro-cantilever beam experiments and modeling in porous polycrystalline UO 2

Understanding the impact of microstructure on the thermo-mechanical behavior of oxide nuclear fuels is vital to predicting their performance through multiscale models. Evaluating the mechanical properties at the sub-grain length scale is key to developing these multiscale models. In this work, 3D finite element (FE) models were constructed to simulate the micrometer-scale bending of micro-cantilever beams fabricated using porous polycrystalline uranium dioxide (UO 2 ) and tested at room temperature. Here, the results showed that the porosity and elastic anisotropy of individual grains can play a significant role in determining the effective mechanical properties of the material deduced from the tests. Specifically, the porosity had a non-negligible effect, given that the pore size was of the same order of magnitude as the dimensions of the micro-beams. Correlations between load-deflection data, pore location, and elastic properties (effective Young's modulus) were investigated using UO 2 micro-beam FE models, where pore clusters were included and placed at different locations along the length of the beam. Results indicated that the presence of pore clusters near the substrate, i.e., the clamp of the micro-cantilever beam, has the strongest effect on the load-deflection behavior, with the porosity leading to a reduction of stiffness that is the largest for any location of the pore clusters. Furthermore, it was also found that pore clusters located towards the middle of the span and close to the end of the beam have a comparatively small effect on the load-deflection behavior. Therefore, it is concluded that accurate estimates of Young's modulus can be obtained from micro-cantilever experiments after accounting for porosity on the one third of the beam length close to the clamp. This, in turn, provides an avenue to improve microscale experiments and their analysis in porous, anisotropic elastic materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coherency-Constrained Spectral Clustering for Power Network Reduction

This paper presents a methodology for reducing the complexity of large-scale power network models using spectral clustering, aggregation of electrical components, and cost function approximation. Two approaches are explored using unconstrained and constrained spectral clustering to determine areas for effective system reduction. Once the system areas are determined, both loads and generators by type are aggregated, and their new cost function is approximated through polynomial curve-fitting or statistical methods. The performance of reduced networks is evaluated in terms of their ability to follow the true daily cost of the original system over a 24-hour period considering a set of several days. Two test systems are taken as test beds. Application of the methodology to a modified version of the IEEE 39-bus system reduces it from 17 generators to a 4-bus system and 9 generators with about 93% of accuracy. Similarly, the IEEE 118-bus system is reduced from 19 generators to a 3-bus system with three aggregated units achieving over 99% of accuracy. These findings address scalability challenges and enhance accuracy for high and mid-loading level conditions, and by aggregating thermal units with similar cost functions.

42 ENGINEERING↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of sintered bauxite proppant for binary enhanced geothermal systems

Abstract Solid granular proppant particles are widely used in oil and gas development to sustain permeability through fractures after hydraulic stimulation. Similar proppants are of interest for geothermal applications where the goal of sustaining permeability is the same, but the harsh geothermal environment risks rapid proppant degradation that will reduce fracture permeability. Here, we present proppant conductivity experiments using saw cut granite, tensile fractured granite, and aluminum control specimens packed with sintered bauxite ceramic proppants at concentrations of 0.0, 0.1, and 1.0 kg/m 2 . Simulated geothermal conditions included temperatures up to 130 °C and normal closure stresses up to 60 MPa. Compared to unpropped specimens, peak fracture conductivity enhancement was up to 6 orders of magnitude. At simulated geothermal conditions, proppants were able to sustain fracture conductivity over 60 h, but chemical dissolution and decreasing permeability over time were evident. Irreversible conductivity reductions with crushing and embedment of proppants during loading stages were also observed. Overall, sintered bauxite proppant remains a promising option for low-temperature binary-cycle enhanced geothermal systems.

58 GEOSCIENCES↗

Effect of framework Al pairing on NO storage properties of Pd-CHA passive NOx adsorbers

For this study, three Pd/H-CHA samples were prepared containing 53.0%, 10.8% and 6.5% paired Al sites at near fixed Si/Al ratio and similar Pd loading. According to H 2 temperature-programmed reduction, Pd was present almost exclusively as isolated cations in the two samples containing the higher concentrations of paired Al sites, whereas in the other sample PdO was also present. Simulated lean cold start tests on the fresh samples conducted in a microflow reactor showed that the sample containing PdO stored the lowest amount of NOx. When tested with CO/H 2 , the sample containing 53.0% paired Al sites showed significantly better storage capacity than the other samples and deactivated less rapidly upon sequential tests. Experiments using lean gasoline engine exhaust revealed similar trends. This study showed that a high concentration of paired Al sites in Pd/H-CHA is beneficial for NOx storage capacity, thermal durability, and minimizing deactivation in the presence of CO/H 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical production of H 2 O 2 on palladium-based clusters driven by metal–support interaction

Utilizing palladium (Pd) clusters as active sites offers a promising route to minimize noble metal consumption in electrochemical hydrogen peroxide (H 2 O 2 ) production. In this work, we present a synthesis approach for anchoring Pd-based clusters onto carbon-supported CeO 2 nanosubstrates to enable efficient H 2 O 2 generation via the two-electron oxygen reduction reaction (ORR) pathway. By systematically adjusting Pd loading, we evaluated its impact on H 2 O 2 yield and production rate. The catalyst with the lowest Pd content (0.027 wt%) exhibited outstanding performance, achieving 97% H 2 O 2 selectivity, 94.2 faradaic efficiency at 0.7 V vs. RHE, and a peak production rate of 195.8 mol g Pd −1 h −1 . A formulation containing 0.35 wt% Pd delivered a peak ORR mass activity nearly three times as high as that of commercial 10 wt% Pd/C, while retaining comparable electrochemical stability. These enhancements are attributed to synergistic effects among isolated PdO clusters, CeO 2 nanocrystals, and the conductive carbon support, which together facilitate oxygen adsorption and promote the two-electron ORR pathway. Analysis after accelerated durability testing further revealed a tendency toward cluster agglomeration and mass transfer from smaller to larger nanocrystals, indicative of a coarsening mechanism. Overall, this study underscores the promise of low-Pd PdO–CeO 2 –carbon hybrid catalysts for scalable and efficient H 2 O 2 electrosynthesis, while highlighting stability as a critical area for future improvement.

36 MATERIALS SCIENCE↗

MADE3D™ (Manufacturing and Additive Design of Electric Machines Enabled by Three-Dimensional Printing) [SWR-20-70]

The MADE3D™ software uses advanced neural networks for realizing novel high torque density electric machine designs with desired functional specifications not limited to but including torque, magnetic loading, and mass. This software allows for a reduction in cost of design by using next-generation computational resources including the cloud while still maintaining high accuracy. The design of the neural networks allows for exploration of large design space and possibilities to find more optimal designs and accommodate new manufacturing technologies like 3D printing.

Sethuraman, Latha↗

Development of a medium-duty stoichiometric diesel micro-pilot natural gas engine

Fueling a compression-ignition engine with premixed natural gas offers the potential to combine a clean-burning, low-carbon fuel with a high compression ratio, high-efficiency engine. This work describes the development of a multi-cylinder 6.7 L diesel engine converted to run stoichiometric diesel micro-pilot/ natural gas premix combustion with a maximum diesel contribution target of 5% of the total fuel energy and a three-way catalyst aftertreatment system. Results are given by comparing the stoichiometric combustion to the diesel baseline operation, showing combustion characteristics differences, including the rapid two stage heat release. A high load output of 23 bar brake mean effective pressure was obtained with diesel-like brake thermal efficiency of 41%. This operating condition enabled a brake specific CO 2 emissions reduction of up to 25% when compared to diesel. It was observed that the low load output is limited by combustion stability when operated at stoichiometric condition. The three-way catalyst is observed to run at peak efficiency with an equivalence ratio of 1.01. Injector fouling was observed through the inspection of the nozzle and its internal parts, indicating carbon build-up similar to that seen in injector coking mechanisms. A comparison of the developed engine to other engine technologies is given, showing that the diesel micro-pilot natural gas engine performance is in good standing among other diesel and gas engines in the market.

Engineering↗

TEAMER: FOSWEC Mooring Modeling and Analysis, Post Access Report and Data

Floating oscillating surge wave energy converters (FOSWECs) offer several advantages over bottom-hinged oscillating surge wave energy converters, including large wave potential at deep-water sites with fewer permitting and environmental concerns outside territorial waters. As a team, Stevens Institute of Technology, Virginia Tech and Resolute Marine Energy are designing a 100 kW FOSWEC with DOE support (2020-2021) for the PacWave test site "PacWave". The proposed FOSWEC consists of a floating platform, two pivoting flaps, and an innovative power-take-off (PTO). The distance between the two flaps is around half the typical wavelength, resulting in out-of-phase motion and a reduction in motion of the frame and mooring loads. The overall goal of the project is to design, build, deploy and analyze a 1:2 scale (100-kW annual averaged electrical power output) device with reduced levelized cost of energy (LCOE) and peak-to-average power ratio, through the co-design and control of the PTO, WEC, and floating platform. This submission includes a Post Access Report and data for the project of Mooring Modeling and Analysis for Floating Oscillating Surge Wave Energy Converter that Powers Marine Aquaculture of RFTS2 (request for technical support). The data are used to generate all figures in the Post Access Report. Project was a collaboration between Virginia Tech and the National Renewable Energy Lab, with funding from TEAMER.

16 TIDAL AND WAVE POWER↗