Space suit for the moon.
Apollo space suit design discussing construction, purpose and operating conditions of liquid-cooled life support system
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Apollo space suit design discussing construction, purpose and operating conditions of liquid-cooled life support system
Test firing of the Space Shuttle Reaction Control Thruster (SSRCT) was conducted to determine the characteristic velocity and chamber throat temperatures when the fuel is changed from monomethylhydrazine (MMH) to hydrazine. Thruster performance with hydrazine was essentially as predicted. Characteristic velocity at a mixture ratio of 1.4 (equal volumetric flow) for hydrazine was 5180 feet/second compared with 5110 feet/second at a mixture of 1.6 for MMH. Specific impulse with 22:1 nozzle is calculated to be 280 lbf-sec/lbm. Thermal performance, as measured by chamber throat temperature, was dramatically different (colder) than predicted. Throat temperatures of 2330 F were predicted from a cooling model which assumed a reactive liquid cooling film. Throat temperatures of 800 - 1000 F were measured. An attempt to reconcile the differences between film cooling predictions and the measurements, indicated that an evaporation (nonreactive fluid) model rather than a decomposition (reactive fluid) model best fits the test data at 0/F = 1.4. At higher mixture ratios, a transition to temperatures typical of the reactive fluid model were observed.
The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.
Apollo space suit design including personal liquid cooling for conditioning and replenishing atmosphere inside space suit
Liquid cooled undergarments tested for metabolic heat dissipation of men working in thermally isolated environment
Control rod modeling in Liquid Metal-cooled Fast Reactors (LMFRs) is important for an accurate simulation, especially in depletion calculations. Recently, control rod search and cusping models have been added to the LUPINE multiphysics fast reactor simulator. LUPINE stands for the 'LMFR Utility for Physics Informed Nuclear Engineering' and is currently being developed at North Carolina State University. LUPINE models the coupled multiphysics effects in LMFRs, including neutronics, thermal hydraulics, thermal expansion, and depletion. The control rod search has been implemented using a Newton-secant search in an inexact-Newton iteration and the cusping model uses a polynomial technique to correct for control rod cusping. The control rod cusping and search models were demonstrated by modeling the Advanced Burner Reactor (ABR) MET-1000 Sodium-cooled Fast Reactor (SFR) and a long-life Lead-cooled Fast Reactor (LFR) based on a Westinghouse Electric Company, LLC (WEC) design. A differential control rod worth curve was calculated for both reactor models to demonstrate the control rod cusping model. The SFR and LFR models were used to demonstrate the importance of modeling control rod movement during depletion calculations and the adverse effect of control rods on cycle length is demonstrated. (authors)
The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi?s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 1200 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 1200 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.
The Spacesuit Water Membrane Evaporator (SWME) is a heat-rejection device that is being developed to perform thermal control for advanced spacesuits. Cooling is achieved by circulating water from the liquid cooling garment (LCG) through hollow fibers (HoFi s), which are small hydrophobic tubes. Liquid water remains within the hydrophobic tubes, but water vapor is exhausted to space, thereby removing heat. A SWME test article was tested over the course of a year, for a total of 600 cumulative hours. In order to evaluate SWME tolerance to contamination due to constituents caused by distillation processes, these constituents were allowed to accumulate in the water as evaporation occurred. A test article was tested over the course of a year for a total of 600 cumulative hours. The heat rejection performance of the SWME degraded significantly--below 700 W, attributable to the accumulation of rust in the circulating loop and biofilm growth. Bubble elimination capability, a feature that was previously proven with SWME, was compromised during the test, most likely due to loss of hydrophobic properties of the hollow fibers. The utilization of water for heat rejection was shown not to be dependent on test article, life cycle, heat rejection rate, or freezing of the membranes.
New athletic wear design based on the circulating liquid cooling system used in the astronaut's space suits, allows athletes to perform more strenuous activity without becoming overheated. Techni-Clothes gear incorporates packets containing a heat-absorbing gel that slips into an insulated pocket of the athletic garment and is positioned near parts of the body where heat transfer is most efficient. A gel packet is good for about one hour. Easily replaced from a supply of spares in an insulated container worn on the belt. The products, targeted primarily for runners and joggers and any other athlete whose performance may be affected by hot weather, include cooling headbands, wrist bands and running shorts with gel-pack pockets.
A lightweight, regenerable heat absorber (RHA), developed for rejecting metabolic heat from a space suit, may also be useful on Earth for short-term cooling of heavy protective garments. Unlike prior space-suit-cooling systems, a system that includes this RHA does not vent water. The closed system contains water reservoirs, tubes through which water is circulated to absorb heat, an evaporator, and an absorber/radiator. The radiator includes a solution of LiCl contained in a porous material in titanium tubes. The evaporator cools water that circulates through a liquid-cooled garment. Water vapor produced in the evaporator enters the radiator tubes where it is absorbed into the LiCl solution, releasing heat. Much of the heat of absorption is rejected to the environment via the radiator. After use, the RHA is regenerated by heating it to a temperature of 100 C for about 2 hours to drive the absorbed water back to the evaporator. A system including a prototype of the RHA was found to be capable of maintaining a temperature of 20 C while removing heat at a rate of 200 W for 6 hours.
As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data
This is the Monthly Letter Progress Report for the eighth month of a twelve month technical study directed toward the following objectives: A. Determining analytically and experimentally the feasibility and attractiveness of using free-standing pyrolytic graphite for a radiation cooled liquid rocket thrust chamber and exit nozzle for space application. B. Establishing through analysis and experimental demonstration, a set of design principles to facilitate the design of a reliable pyrolytic graphite thrust chamber assembly for a specific range of operating conditions. C. Demonstrate by means of test firings of complete thrust chamber assemblies, the validity of the design data and principles developed during the program. Preparations have been completed for test firing the two 100 lb. thrust Boron Pyralloy chambers at Marquardt during the first week in March 1962. These two chambers will first be static pressure checked with water to a pressure of 135 psig. The chambers will then be test fired with N204/N2H4-MMH propellants . Test samples of eleven different pyrolytic carbide and nitride materials have been ordered for high temperature oxidation tests and should be delivered by the end of March for evaluation in the plasma torch facility. The specific materials ordered in free- standing condition in thicknesses from 0.030 inch to 0.065 inch were as follows: (a) Pyrolytic graphite (on hand) (b) Pyrolytic graphite-boron alloy (on hand) (c) Pyrolytic graphite-tungsten alloy (d)Boron nitride (e) Titanium nitride (f) Silicon carbide (g) Titanium carbide (h) Zirconium carbide (i) Hafnium carbide (j) Niobium carbide (k) Tantalum carbide (l) High density (1 1-90) graphite (m) High density graphite (heat treated) These materials were ordered from Raytheon, HTM, and American Meta 1 Products . A summary of the available data on the oxidation rates of pyrolytic materials under slow air and rocket motor conditions is shown in Figure 1. High Temperature Materials, Inc. has been contacted relative to providing Pyrographite thrust chambers with extra-thick walls . They believe they can deliver chambers with substantially thicker walls than were possible a short time ago. Such a configuration, with acceptable residual stresses, would provide a longer firing life since it is ultimately limited by the oxidation rate of the chamber wall material. Stress and structural studies have continued. The analytical stress studies point out some of the problems associated with the experimental determination of the elastic constants of this highly anisotropic material. Further analysis may shed light on improved techniques for making these experimental determinations. The large potential weight saving available with the use of pyrolytic graphite as a thrust chamber wall material in a radiation cooled rocket motor has been calculated and is shown graphically in Figure 2. Figure A presents the program progress schedule and the actual expenditures as of 7 February 1962.
With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.
The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).
The electronic link connecting cryogenically cooled radiation detectors to data acquisition and signal processing electronics at higher temperatures contributes significantly to the total heat load on spacecraft cooling systems that use combined mechanical and cryogenic liquid cooling. Using high transition temperature superconductors for this link has been proposed to increase the lifetime of space missions. Herein, several YBCO (YBa2Cu3O7) superconductor-substrate combinations were examined and total heat loads were compared to manganin wire technology in current use. Using numerical solutions to the heat-flow equations, it is shown that replacing manganin technology with YBCO thick film technology can extend a 7-year mission by up to 1 year.
Many manufacturers of loudspeakers are now using a magnetic liquid cooling agent known as ferrofluid. Commercialized by Ferrofluids Corporation, ferrofluid is a liquid material in which sub-microscopic particles of iron oxide are permanently suspended. Injected into the voice coil segment of speaker system, magnetic liquid serves as superior heat transfer medium for cooling the voice coil, thus substantially increasing the system's ability to handle higher power levels and decreasing chance of speaker failure. Ferrofluid offers several additional advantages which add up to improved speaker performance, lower manufacturing costs and fewer rejects.
The U.S. Army Research Laboratory, Fort Monmouth, NJ, has developed and is installing two 3.3 MW high speed solid state circuit breakers at the Army's Pulse Power Center. These circuit breakers will interrupt 4160V three phase power mains in no more than 300 microseconds, two orders of magnitude faster than conventional mechanical contact type circuit breakers. These circuit breakers utilize Gate Turnoff Thyristors (GTO's) and are currently utility type devices using air cooling in an air conditioned enclosure. Future refinements include liquid cooling, either water or two phase organic coolant, and more advanced semiconductors. Each of these refinements promises a more compact, more reliable unit.
Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.