Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Direct dark matter searches with metal halide perovskites

Polar materials with optical phonons in the meV range are excellent candidates for both dark matter direct detection via dark photon-mediated scattering and light dark matter absorption. In this study, we propose, for the first time, the metal halide perovskites MAPbI 3 , MAPbCl 3 , and CsPbI 3 for these purposes. Our findings reveal that CsPbI 3 is the best material, significantly improving exclusion limits compared to other polar materials. For scattering, CsPbI 3 can probe dark matter masses down to the keV range. For absorption, it enhances sensitivity to detect dark photon masses below ∼10 meV. The only material that has so far been investigated and that could provide competitive bounds is CsI, which, however, demonstrates lower stability as device platform compared to CsPbI 3 . Moreover, CsI is isotropic while the anisotropic structure of CsPbI 3 enables daily modulation analysis, showing that a significant percentage of daily modulation exceeding 1% is achievable for dark matter masses below 40 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reaction times to weak test lights

Maloney and Wandell (1984) describe a model of the response of a single visual channel to weak test lights. The initial channel response is a linearly filtered version of the stimulus. The filter output is randomly sampled over time. Each time a sample occurs there is some probability increasing with the magnitude of the sampled response - that a discrete detection event is generated. Maloney and Wandell derive the statistics of the detection events. In this paper a test is conducted of the hypothesis that the reaction time responses to the presence of a weak test light are initiated at the first detection event. This makes it possible to extend the application of the model to lights that are slightly above threshold, but still within the linear operating range of the visual system. A parameter-free prediction of the model proposed by Maloney and Wandell for lights detected by this statistic is tested. The data are in agreement with the prediction.

Wandell, B. A.↗

Design and optimization of high temperature optocouplers as galvanic isolation

The commercial InGaN-based (blue and green) and AlGaInP-based (red) multiple quantum well (MQW) lighting emitting diodes (LEDs) were studied in a wide range of temperatures up to 800 K for their light emission and detection (i.e., LEDs operated under reverse bias as photodiodes (PDs)) characteristics. The results indicate the feasibility of integrating a pair of selected LEDs to fabricate high temperature (HT) optocouplers, which can be utilized as galvanic isolation to replace the bulky isolation transforms in the high-density power modules. A detailed study on LEDs and PDs were performed. The external quantum efficiency (EQE) of the LED and PDs were calculated. Higher relative external quantum efficiency (EQE) and lower efficiency droops with temperatures are obtained from the blue and green LEDs for display compared with the blue one for lighting and red LED for display. The blue for lighting and red for display devices show superior responsivity, specific detectivity (D*), and EQE compared with blue and green for display when operated as PDs. The results suggest that red LED devices for display can be used to optimize HT optocouplers due to the highest wavelength overlapping compared with others.

42 ENGINEERING↗

Limb-atmospheric infrared spectrum observed on the satellite Ohzora

The Institute of Space and Astronautical Science (ISAS) launched the 9th scientific satellite Ohzora at 17:00 JST on February 14, 1984. This satellite bears the spectrometer, which measures the infrared spectrum of the solar radiation passing the limb atmosphere in the wavelength region of 2 to 10 m. The spectrometer is based on multichannel spectroscopy by using image sensors. Since the wavelength is scanned electronically, it can measure the spectrum unaffected by the satellite motion. A definite axis, i.e., the Z-axis of the satellite, which coincides to the optical axis of the spectrometer, is controlled to the direction of the Sun, and the finer control to introduce the solar light into the spectrometer is made with a 2-axes-controlled mirror. This solar tracking equipment is derived fast enough to measure the spectra in a moment after sunrise. The solar light introduced into the spectrometer is focused on the slits of the monochromators (f=100mm). For better altitude resolution, the horizontal slit is also used with the vertical slit, which is used for the separation of the dispersion. The dispersion light is detected with the pyroelectric array sensors. To obtain maximum dynamic range and spectral resolution, the three-stage polychromator is used.

Matsuzaki, A.↗

Ultrafast, multiphoton-pump, multiphoton-probe spectroscopy

Methods for pump-probe spectroscopy are provided. In an embodiment, such a method comprises directing pump light having a frequency ωpump at a location in a sample to excite a transition between two quantum states of a target entity in the sample, directing probe light at the location to generate a coherent output signal having a frequency ωoutput and a wavevector koutput, and detecting the output signal as the probe light is scanned over a range of frequencies. In the method, either the transition excited by the pump light is a multiphoton transition corresponding to a frequency difference of n*ωpump, wherein n≥2; or the probe light is a set of m coherent light pulses, each coherent light pulse having a frequency ωm and a wavevector km, wherein m≥2; or both. Systems for carrying out the methods are also provided.

Morrow, Darien James↗

Single-Particle Measurements of Midlatitude Black Carbon and Light-Scattering Aerosols from the Boundary Layer to the Lower Stratosphere

A single-particle soot photometer (SP2) was flown on a NASA WB-57F high-altitude research aircraft in November 2004 from Houston, Texas. The SP2 uses laser-induced incandescence to detect individual black carbon (BC) particles in an air sample in the mass range of approx.3-300 fg (approx.0.15-0.7 microns volume equivalent diameter). Scattered light is used to size the remaining non-BC aerosols in the range of approx.0.17-0.7 microns diameter. We present profiles of both aerosol types from the boundary layer to the lower stratosphere from two midlatitude flights. Results for total aerosol amounts in the size range detected by the SP2 are in good agreement with typical particle spectrometer measurements in the same region. All ambient incandescing particles were identified as BC because their incandescence properties matched those of laboratory-generated BC aerosol. Approximately 40% of these BC particles showed evidence of internal mixing (e.g., coating). Throughout profiles between 5 and 18.7 km, BC particles were less than a few percent of total aerosol number, and black carbon aerosol (BCA) mass mixing ratio showed a constant gradient with altitude above 5 km. SP2 data was compared to results from the ECHAM4/MADE and LmDzT-INCA global aerosol models. The comparison will help resolve the important systematic differences in model aerosol processes that determine BCA loadings. Further intercomparisons of models and measurements as presented here will improve the accuracy of the radiative forcing contribution from BCA.

Schwartz, J. P.↗

Finite source sizes and the information content of macho-type lens search light curves

If the dark halo matter is primarily composed of Massive Compact Halo Objects (MACHOs) toward the lower end of the possible detection range (less than 10(exp -3) solar mass) a fraction of the lens detection events should involve the lens crossing directly in front of the disk of the background star. Previously, Nemiroff has shown that each crossing would create an inflection point in the light curve of the MACHO event. Such inflection points would allow a measure of the time it took for the lens to cross the stellar disk. Given an independent estimate of the stellar radius by other methods, one could then obtain a more accurate estimate of the velocity of the lens. This velocity could then, in turn, be used to obtain a more accurate estimate of the mass range for the MACHO or disk star doing the lensing.

Nemiroff, Robert J.↗

Combining quantum noise reduction resources: A practical approach

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. Here, we demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

Optomechanics↗

Oxygen detection using the laser diode absorption technique

Accurate measurement of the concentration and flow rate of gaseous oxygen is becoming of greater importance. The detection technique presented is based on the principal of light absorption by the Oxygen A-Band. Oxygen molecules have characteristics which attenuate radiation in the 759-770 nm wavelength range. With an ability to measure changes in the relative light transmission to less than 0.01 percent, a sensitive optical gas detection system was configured. This system is smaller in size and light in weight, has low energy requirements and has a rapid response time. In this research program, the application of temperature tuning laser diodes and their ability to be wavelength shifted to a selected absorption spectral peak has allowed concentrations as low as 1300 ppm to be detected.

Disimile, P. J.↗

A vector-based failure detection and isolation algorithm for a dual fail-operational redundant strapdown inertial measurement unit

A vector-based failure detection and isolation technique for a skewed array of two degree-of-freedom inertial sensors is developed. Failure detection is based on comparison of parity equations with a threshold, and isolation is based on comparison of logic variables which are keyed to pass/fail results of the parity test. A multi-level approach to failure detection is used to ensure adequate coverage for the flight control, display, and navigation avionics functions. Sensor error models are introduced to expose the susceptibility of the parity equations to sensor errors and physical separation effects. The algorithm is evaluated in a simulation of a commercial transport operating in a range of light to severe turbulence environments. A bias-jump failure level of 0.2 deg/hr was detected and isolated properly in the light and moderate turbulence environments, but not detected in the extreme turbulence environment. An accelerometer bias-jump failure level of 1.5 milli-g was detected over all turbulence environments. For both types of inertial sensor, hard-over, and null type failures were detected in all environments without incident. The algorithm functioned without false alarm or isolation over all turbulence environments for the runs tested.

Morrell, Frederick R.↗

Short range laser obstacle detector

A short range obstacle detector for surface vehicles is described which utilizes an array of laser diodes. The diodes operate one at a time, with one diode for each adjacent azimuth sector. A vibrating mirror a short distance above the surface provides continuous scanning in elevation for all azimuth sectors. A diode laser is synchronized with the vibrating mirror to enable one diode laser to be fired, by pulses from a clock pulse source, a number of times during each elevation scan cycle. The time for a given pulse of light to be reflected from an obstacle and received is detected as a measure of range to the obstacle.

Kuriger, W. L.↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Space Borne Event Timer

The Space Borne Event Timer is a part of the NASA laser ranging system that is intended to operate aboard the Space Shuttle orbiting over California. The object is to measure, by laser ranging, the earth movement along the San Andreas fault and possibly forecast future earthquakes. A number of cube reflector targets will be placed along both sides of the fault. The ranging system aboard the Space Shuttle will fire a burst of laser pulses at each target and detect the reflected light. Time differences between pulses from the two sides of the fault will indicate earth displacements. The Space Borne Event Timer is a CAMAC compatible system that provides extremely accurate timing data and controls the operation of the ranging system. For each event the time is given in 19.53 increments from the instant of firing the laser to the instant the reflected light is received back, within a range of 130 days.

Turko, B.↗

Resonant tunneling IR detectors

Researchers propose a novel semiconductor heterojunction photodetector which would have a very low dark current and would be voltage tunable. A schematic diagram of the device and its band structure are shown. The two crucial components of the device are a cathode (InGaAs) whose condition band edge is below the conduction band edge of the quantum wells and a resonant tunneling filter (GaAs-AlGaAs). In a standard resonant tunneling device the electrodes are made of the same material as the quantum wells, and this device becomes highly conducting when the quantum levels in the wells are aligned with the Fermi level in the negatively biased electrode. In contrast, the researchers device is essentially non-conducting under the same bias conditions. This is because the Fermi Level of the cathode (InGaAs) is still well below the quantum levels so that no resonant transport occurs and the barriers (AlGaAs) effectively block current flow through the device. However, if light with the same photon energy as the conduction-band discontinuity between the cathode and the quantum wells, E sub c3-E sub c1, is shone on the sample, free carriers will be excited to an energy corresponding to the lowest quantum level in the well closest to the cathode (hv plue E sub c1 = E sub o). These electrons will resonantly tunnel through the quantum wells and be collected as a photocurrent in the anode (GaAs). To improve the quantum efficiency, the cathode (InGaAs) should be very heavily doped and capped with a highly reflective metal ohmic contact. The thickness of the device should be tailored to optimize thin film interference effects and afford the maximum absorption of light. Because the device relies on resonant tunneling, its response should be very fast, and the small voltages needed to change the responsivity should allow for very high frequency modulation of the photocurrent. In addition, the device is tuned to a specific photon energy so that it can be designed to detect a fairly narrow range of wavelengths. This selectivity is important for reducing the photocurrent due to spurious light sources.

Woodall, Jerry M.↗

Direct imaging of extra-solar planetary systems with the Circumstellar Imaging Telescope (CIT)

In a joint study conducted by the Jet Propulsion Laboratory and the Perkin-Elmer Corporation it was found that an earth orbital, 1.5 meter diameter low scattered light coronagraphic telescope can achieve a broad range of scientific objectives including the direct detection of Jupiter-sized planets around the nearby stars. Recent major advances in the understanding of coronagraphic performance and in the field of super smooth mirror fabrication allow such an instrument to be designed and built within current technology. Such a project, called the Circumstellar Imaging Telescope (CIT), is currently being proposed.

Terrile, Richard J.↗

Optical leak detection of oxygen using IR-laser diodes

The ability to accurately measure the concentration of gaseous oxygen and its corresponding flow rate is becoming of greater importance. The technique being presented is based on the principal of light attenuation due to the absorption of radiation by the A-band of oxygen which is located in the 759-770 nm wavelength range. With an ability to measure the change in the light transmission to 0.05 percent, a sensitive optical leak detection system which has a rapid time response is possible. In this research program, the application of laser diode technology and its ability to be temperature tuned to a selected oxygen absorption spectral peak has allowed oxygen concentrations as low as 16,000 ppm to be detected.

Disimile, P. J.↗

Estimation of Rain Intensity Spectra over the Continental US Using Ground Radar-Gauge Measurements

A high-resolution surface rainfall product is used to estimate rain characteristics over the continental US as a function of rain intensity. By defining each data at 4-km horizontal resolutions and 1-h temporal resolutions as an individual precipitating/nonprecipitating sample, statistics of rain occurrence and rain volume including their geographical and seasonal variations are documented. Quantitative estimations are also conducted to evaluate the impact of missing light rain events due to satellite sensors' detection capabilities. It is found that statistics of rain characteristics have large seasonal and geographical variations across the continental US. Although heavy rain events (> 10 mm/hr.) only occupy 2.6% of total rain occurrence, they may contribute to 27% of total rain volume. Light rain events (< 1.0 mm/hr.), occurring much more frequently (65%) than heavy rain events, can also make important contributions (15%) to the total rain volume. For minimum detectable rain rates setting at 0.5 and 0.2 mm/hr which are close to sensitivities of the current and future space-borne precipitation radars, there are about 43% and 11% of total rain occurrence below these thresholds, and they respectively represent 7% and 0.8% of total rain volume. For passive microwave sensors with their rain pixel sizes ranging from 14 to 16 km and the minimum detectable rain rates around 1 mm/hr., the missed light rain events may account for 70% of train occurrence and 16% of rain volume. Statistics of rain characteristics are also examined on domains with different temporal and spatial resolutions. Current issues in estimates of rain characteristics from satellite measurements and model outputs are discussed.

Lin, Xin↗

The Swift/BAT Hard X-Ray Survey

The BAT instrument on Swift is a wide field (70 deg. '100 deg.) coded aperture instrument with a CdZnTe detector array sensitive to energies of 14-200 keV. Each day, the BAT survey typically covers 60% of the sky to a detection limit of 30 millicrab. BAT makes hard X-ray light curves of similar sensitivity and coverage to the X-ray light curves from XTE/ASM, but in an energy range where sources show remarkably different behavior. Integrating the BAT data produces an all sky map with a source detection limit at 15 months of a few 10(exp -11) ergs per square centimeter per second, depending on the exposure. This is the first uniform all-sky survey at energies high enough to be unaffected by absorption since HEAO 1 in 1977-8. BAT has detected greater than 200 AGN and greater than 180 galactic sources. At high galactic latitudes, the BAT sources are usually easy to identify, but many are heavily absorbed and there are a few quite surprising identifications. The BAT selected galaxies can be used to calculate LogN/LogS and the luminosity function for AGN which are complete and free from common systematics. Several crucial parameters for understanding the cosmic hard x-ray background are now determined.

Tueller, Jack↗