Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “levelized cost of heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Fast Modular Reactor (FMR) - Development Plan of a New 50 MWe Gas-cooled Fast Reactor

General Atomics Electromagnetic Systems (GA-EMS) will be developing a new 50-megawatt electric (MWe) fast modular reactor (FMR), under the Department of Energy’s (DOE’s) Advanced Reactor Demonstration Program (ARDP), Advanced Reactor Concepts 2020 (ARC-20) development pathway, that provides safe, carbon free electricity, capable of incremental capacity additions. A modular design allows it to be factory-built and assembled on-site to keep the cost of capital low, while the dry-cooling facilitates siting to complement renewables in nearly any location. GA-EMS is committed to commercialization of the proposed reactor, with a demonstration by 2030, and deployment by the mid-2030s. The ultimate goal of the design is to develop flexible and dispatchable carbon-free power source for the 2035 US electricity market. The GAEMS- led team will verify that simplified characteristics (e.g., inert helium gas coolant, pellet-loaded fuel rod, installation-free of heat sink requirements, small and passive heat removal systems) of the FMR will result in a safe, maintainable, cost-effective, distributed, nuclear energygenerating station. Three key specific project objectives for the next three years include: Development of the conceptual design of the 50- MWe FMR plant, Achievement of Technology Readiness Level (TRL) 4 for key system and component technologies through in-pile tests, out-of-pile tests, and numerical experiments; and Development of robust techno-economic analysis (TEA) and pre-application licensing approach necessary for timely demonstration and eventual commercialization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Powerstick Development

Proof of concept testing has been performed on a 'powerstick' trickle charger, which uses heat from a radioisotope heater unit to charge spacecraft batteries. The type of unit being tested uses a bismuth-telluride thermoelectric converter to produce roughly 40 mW at 15 V. This is much less power than a radioisotope thermoelectric generator (RTG), but the cost and level of environmental concern are also much less.

spacecraft power radioisotope heater unit RHU↗

Multi-Fidelity Heating Prediction of Adaptable, Deployable Entry Placement Technology Vehicles

The objective of this work was to investigate a multi-fidelity modeling approach to accurately and efficiently predict the laminar and turbulent convective heating on adaptable, deployable entry placement technology vehicles in Mars entry. A previously developed co-Kriging based multi-fidelity modeling approach was used to model the laminar and turbulent convective heat fluxes at several surface locations along the vehicle, including the rib sections. The laminar convective heat flux multi-fidelity model was found to have a mean convective heat rate error of approximately 3% when compared to high-fidelity CFD simulations. The turbulent convective heat flux multi-fidelity model was found to have a mean convective heat rate error of approximately 8% when compared to high-fidelity CFD simulations. Compared to a single fidelity model, the multi-fidelity model required approximately one-third the number of high-fidelity model evaluations to obtain the same accuracy level. The computational cost of evaluating the multi-fidelity model was approximately five orders of magnitude less than one high-fidelity model simulation.

Mario Santos↗

What is the long-term demand for liquid hydrocarbon fuels and feedstocks?

Liquid hydrocarbons made from crude oil serve many functions: (1) a dense, easy-to-store, easy-to-transport energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent and (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes. Liquid hydrocarbons can be produced and used without increasing atmospheric carbon dioxide levels if made from non-fossil feedstocks such as carbon dioxide or biomass. Understanding future liquid hydrocarbon demand is the starting point in assessing the viability of such options. Our assessment is that U.S. demand for liquid hydrocarbons is unlikely to go below the equivalent of 10 million barrels per day of crude oil but could be as high as 20 million barrels per day. The costs to replace liquid hydrocarbons increases rapidly at lower liquid hydrocarbon consumption rates. Hydrocarbon biofuels from cellulosic feedstocks can meet such demands if produced with large external inputs of heat and hydrogen. Options based on more limited feedstocks (starches, plant oils, sugars, etc.) can’t meet such demands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Techno-economic prospects for producing Fischer-Tropsch jet fuel and electricity from lignite and woody biomass with CO 2 capture for EOR

This work explores the prospective techno-economic performance of facilities that produce low- and net-negative-carbon liquid transportation fuels and electricity with CO 2 capture for enhanced oil recovery. The lignite and biomass-to-jet fuel process is based on KBR’s TRIG gasifier, Rectisol (for sulfur removal and CO 2 capture), fixed-bed low temperature Fischer-Tropsch synthesis of liquid fuels, and Brayton/Rankine combined cycles to convert synthesis/refining off-gases and waste heat to electricity. This work leverages a recent, highly-detailed assessment of a prospective first-of-a-kind (FOAK) demonstration facility to develop highly detailed Aspen Plus process simulations for nine prospective N th -of-a-kind (NOAK) plant equipment configurations. Component-level capital costs from the FOAK study are scaled and adjusted to reflective prospective learning-by-doing to estimate capital costs for the NOAK designs. NOAK plant economic performance is found to be largely insensitive to variations in plant configurations and electricity output fraction, but biomass input fraction significantly affects profitability. Facilities that consume only carbon–neutral biomass, with no lignite co-feed, have significantly net-negative carbon emissions and the most favorable prospective economics when carbon emissions are priced. For these facilities, the crude oil price required for plant economic viability falls rapidly from $\$$100/bbl as carbon emission prices increase above $\$$120/tonne CO 2eq . In general, plants that co-fire lignite with biomass are less profitable (than 100% biomass plants) due to their higher net greenhouse gas emissions.

09 BIOMASS FUELS↗

Modeling and analysis of synthetic liquid fuel production from CO 2 and nuclear energy using methanol-to-diesel process

Electrofuels (e-fuels) are synthetic fuels produced from carbon dioxide (CO 2 ) and electricity for blending with or replacing petroleum fuels. Nuclear energy is an attractive energy feedstock for e-fuel production because of its low environmental footprint and its ability to provide steady heat and power essential for e-fuels production. We modeled and evaluated the cost and environmental footprint of e-fuels production in the distillate range for three nuclear power scales, 100, 500, and 1000 MWe, through methanol and olefins intermediates leveraging commercial or high technology readiness level (TRL) processes. Compared to the commonly studied e-fuels from Fischer Tropsch process that has a distillate yield of <70% with the rest being low value naphtha, the proposed process via methanol intermediate increases the product selectivity with distillate yield of 96% and only 4% naphtha. The modeled process has a carbon conversion ratio of 98%, and a process energy efficiency of 56% relative to the total equivalent nuclear electricity input. The e-fuel plant economics and GHG emissions were estimated by considering CO 2 collected from ethanol plants adjacent to nuclear power plants. The estimated minimum fuel selling prices (MFSP) of e-fuel is in the range of $5.7-$9.1/gal depending on e-fuel plant scale, electricity cost, and CO 2 transportation distance. The corresponding e-fuels life cycle GHG emissions is estimated in the range of 5-6 gCO 2 e/MJ of liquid fuel using the R&D Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) model.

10 SYNTHETIC FUELS↗

Design tradeoffs for a Space Station solar-Brayton power system

Mass, area, and station-keeping propellant needs have been estimated for a typical system. And, although important criteria such as cost, Shuttle packaging, and erection/deployment schemes were not considered, the documented trends should aid in many of the design choices to be made. Effects on system characteristics were examined for: three heat storage salts with melting temperatures from 743 to 1121 K; parabolic and Cassegrainian mirrors; module power levels of 20 and 40 kW; and, alternate pumped-loop, tube-and-fin radiator configurations, with and without micrometeoroid armoring.

Klann, J. L.↗

Cryogenic Pressure Control Modeling for Ellipsoidal Space Tanks

A computational fluid dynamics (CFD) model is developed to simulate pressure control of an ellipsoidal-shaped liquid hydrogen tank under external heating in normal gravity. Pressure control is provided by an axial jet thermodynamic vent system (TVS) centered within the vessel that injects cooler liquid into the tank, mixing the contents and reducing tank pressure. The two-phase cryogenic tank model considers liquid hydrogen in its own vapor with liquid density varying with temperature only and a fully compressible ullage. The axisymmetric model is developed using a custom version of the commercially available FLOW-31) software. Quantitative model validation is ,provided by engineering checkout tests performed at Marshall Space Flight Center in 1999 in support of the Solar Thermal Upper Stage_ Technology Demonstrator (STUSTD) program. The engineering checkout tests provide cryogenic tank self-pressurization test data at various heat leaks and tank fill levels. The predicted self-pressurization rates, ullage and liquid temperatures at discrete locations within the STUSTD tank are in good agreement with test data. The work presented here advances current CFD modeling capabilities for cryogenic pressure control and helps develop a low cost CFD-based design process for space hardware.

Lopez, Alfredo↗

High-Efficiency Heat Exchanger to Achieve Low-Power CO2 Deposition

This document serves as the Concept of Operations (ConOps) for Iowa State University’s Space Habitat Research group’s design to fulfill the requirements of NASA’s eXploration Systems and Habitation (X-Hab) 2020 Academic Innovation Challenge. The title of the challenge awarded to the group is ‘High-Efficiency Heat Exchanger to Achieve Low-Power CO2 Deposition’, with the scope of the challenge being to ‘characterize the achievable efficiency of an air-to-air heat exchanger in order to cool air for CO2 removal utilizing phase change properties’. The scope of this document includes an introduction that provides background and rationale for the project, a high-level description of the envisioned system, functional requirements, operational scenarios and environment, risk mitigation, and costs and scheduling.

Ward Thomas↗

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study has been conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel which is used to meet the demand when insolation is unavailable and storage is depleted.

Revere, W.↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study was conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel.

Revere, W.↗

A multiblock analysis for shuttle orbiter re-entry heating from Mach 24 to Mach 12

A multiblock, laminar heating analysis for the shuttle orbiter at three trajectory points ranging from Mach 24.3 to Mach 12.86 on re-entry is described. The analysis is performed using the Langley Aerothermodynamic Upwind Relaxation Algorithm (LAURA) with both a seven species chemical nonequilibrium model and an equilibrium model. A finite-catalytic-wall model appropriate for shuttle tiles at a radiative equilibrium wall temperature is applied. Computed heating levels are generally in good agreement with the flight data though a few rather large discrepancies remain unexplained. The multiblock relaxation strategy partitions the flowfield into manageable blocks requiring a fraction of the computational resources (time and memory) required by a full domain approach. In hot, the computational cost for a solution at even a single trajectory point would be prohibitively expensive at the given resolution without the multiblock approach. Converged blocks are reassembled to enable a fully coupled converged solution over the entire vehicle, starting from a nearly converged initial condition.

Gnoffo, Peter A.↗

Multiblock analysis for Shuttle Orbiter reentry heating from Mach 24 to Mach 12

A multiblock, laminar heating analysis for the shuttle orbiter at three trajectory points ranging from Mach 24.3 to Mach 12.86 on reentry is described. The analysis is performed using the Langley Aerothermodynamic Upwind Relaxation Algorithm with a seven species chemical nonequilibrium model. A finite-catalytic-wall model appropriate for shuttle tiles at a radiative equilibrium wall temperature is applied. Computed heating levels are generally in good agreement with the flight data, although a few rather large discrepancies remain unexplained. The multiblock relaxation strategy partitions the flowfield into manageable blocks requiring a fraction of the computational resources (time and memory) required by a full domain approach. In fact, the computational cost for a solution at even a single trajectory point would be prohibitively expensive at the given resolution without the multiblock approach. Converged blocks are reassembled to enable a fully coupled converged solution over the entire vehicle, starting from a nearly converged initial condition.

LANGLEY AEROTHERMODYNAMIC UPWI↗

Experimental Evaluation of the Thermal Performance of a Water Shield for a Surface Power Reactor

A water based shielding system is being investigated for use on initial lunar surface power systems. The use of water may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a representative lunar surface reactor shield design is evaluated at various power levels in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to anchor a CFD model. Performance of a water shield on the lunar surface is then predicted by CFD models anchored to test data. The accompanying viewgraph presentation includes the following topics: 1) Testbed Configuration; 2) Core Heater Placement and Instrumentation; 3) Thermocouple Placement; 4) Core Thermocouple Placement; 5) Outer Tank Thermocouple Placement; 6) Integrated Testbed; 7) Methodology; 8) Experimental Results: Core Temperatures; 9) Experimental Results; Outer Tank Temperatures; 10) CFD Modeling; 11) CFD Model: Anchored to Experimental Results (1-g); 12) CFD MOdel: Prediction for 1/6-g; and 13) CFD Model: Comparison of 1-g to 1/6-g.

Pearson, J. Boise↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗