Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Comparison of Square and Radial Geometries for High Intensity Laser Power Beaming Receivers

In an effort to further advance a realizable form of wireless power transmission (WPT), high intensity laser power beaming (HILPB) has been developed for both space and terrestrial applications. Unique optical-to-electrical receivers are employed with near infrared (IR-A) continuous-wave (CW) semiconductor lasers to experimentally investigate the HILPB system. In this paper, parasitic feedback, uneven illumination and the implications of receiver array geometries are considered and experimental hardware results for HILPB are presented. The TEM00 Gaussian energy profile of the laser beam presents a challenge to the effectiveness of the receiver to perform efficient photoelectric conversion, due to the resulting non-uniform illumination of the photovoltaic cell arrays. In this investigation, the geometry of the receiver is considered as a technique to tailor the receiver design to accommodate the Gaussian beam profile, and in doing so it is demonstrated that such a methodology is successful in generating bulk receiver output power levels reaching 25 W from 7.2 sq cm of photovoltaic cells. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers to achieve a 1.0 sq m receiver capable of generating over 30 kW of electrical power. This type of system would enable long range optical "refueling" of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion. In addition, a smaller HILPB receiver aperture size could be utilized to establish a robust optical communications link within environments containing high levels of background radiance, to achieve high signal to noise ratios.

Raible, Daniel E.↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Attosecond inner-shell lasing at ångström wavelengths

Since the invention of the laser, nonlinear effects such as filamentation, Rabi cycling and collective emission have been explored in the optical regime, leading to a wide range of scientific and industrial applications. X-ray free-electron lasers (XFELs) have extended many optical techniques to X-rays for their advantages of ångström-scale spatial resolution and elemental specificity. An example is XFEL-driven inner-shell Kα 1 (2p 3/2 → 1s 1/2 ) X-ray lasing in elements ranging from neon to copper, which has been used for nonlinear spectroscopy and development of new X-ray laser sources. Here, in this study, we show that strong lasing effects similar to those in the optical regime can occur at 1.5–2.1 Å wavelengths during high-intensity (>10 19 W cm −2 ) XFEL-driven Kα 1 lasing of copper and manganese. Depending on the temporal XFEL pump pulse substructure, the resulting X-ray pulses (about 10 6 −10 8 photons) can exhibit strong spatial inhomogeneities and spectral splitting, inhomogeneities and broadening. Three-dimensional Maxwell–Bloch calculations show that the observed spatial inhomogeneities result from X-ray filamentation and that the broad spectral features are driven by sub-femtosecond Rabi cycling. Our simulations indicate that these X-ray pulses can have pulse lengths of less than 100 attoseconds and coherence properties that provide opportunities for quantum X-ray optics applications.

47 OTHER INSTRUMENTATION↗

Angular displacement measuring device

A system for measuring the angular displacement of a point of interest on a structure, such as aircraft model within a wind tunnel, includes a source of polarized light located at the point of interest. A remote detector arrangement detects the orientation of the plane of the polarized light received from the source and compares this orientation with the initial orientation to determine the amount or rate of angular displacement of the point of interest. The detector arrangement comprises a rotating polarizing filter and a dual filter and light detector unit. The latter unit comprises an inner aligned filter and photodetector assembly which is disposed relative to the periphery of the polarizer so as to receive polarized light passing the polarizing filter and an outer aligned filter and photodetector assembly which receives the polarized light directly, i.e., without passing through the polarizing filter. The purpose of the unit is to compensate for the effects of dust, fog and the like. A polarization preserving optical fiber conducts polarized light from a remote laser source to the point of interest.

Seegmiller, H. Lee B.↗

Some New Lidar Equations for Laser Pulses Scattered Back from Optically Thick Media Such as Clouds, Dense Aerosol Plumes, Sea Ice, Snow, and Turbid Coastal Waters

I survey the theoretical foundations of the slowly-but-surely emerging field of multiple scattering lidar, which has already found applications in atmospheric and cryospheric optics that I also discuss. In multiple scattering lidar, returned pulses are stretched far beyond recognition, and there is no longer a one-to-one connection between range and return-trip timing. Moreover, one can exploit the radial profile of the diffuse radiance field excited by the laser source that, by its very nature, is highly concentrated in space and collimated in direction. One needs, however, a new class of lidar equations to explore this new phenomenology. A very useful set is derived from radiative diffusion theory, which is found at the opposite asymptotic limit of radiative transfer theory than the conventional (single-scattering) limit used to derive the standard lidar equation. In particular, one can use it to show that, even if the simple time-of-flight-to-range connection is irretrievably lost, multiply-scattered lidar light can be used to restore a unique profiling capability with coarser resolution but much deeper penetration into a wide variety of optical thick media in nature. Several new applications are proposed, including a laser bathymetry technique that should work for highly turbid coastal waters.

turbid water↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Influence of Process Parameter and Build Rate Variations on Defect Formation in Laser Powder Bed Fusion SS316L

Laser powder bed fusion (LPBF) is an additive manufacturing process that has gained interest for its material fabrication due to multiple advantages, such as the ability to print parts with small feature sizes, good mechanical properties, reduced material waste, etc. However, variations in the key process parameters in LPBF may result in the instantiation of porosity defects and variation in build rate. Particularly, volumetric energy density (VED) is a variable that encapsulates a number of those parameters and represents the amount of energy input from the laser source to the feedstock. VED has been traditionally used to inform the quality of the printed part but different values of VED are presented as optimal values for certain material systems. An optimal VED value can be maintained by changing the key process parameters so that various combinations yield a constant value. In this study, an optimal constant VED value is maintained while printing SS316L with variable key processing parameters. Porosity analysis is performed using optical microscopy, as well as X-ray computed tomography, to reveal the volume density and distribution of those pores. Two primary defect categories are identified, namely lack of fusion and porosity induced by balling defects. The findings indicate that, even at optimal VED, variations in process parameters can significantly influence defect type, underscoring the sensitivity of defect formation to the variation of these parameters. Furthermore, a minor change in the build rate, driven by adjustments in process parameters, was found to influence defect categories. These findings emphasize that fine tuning the process parameters and build rate is essential to minimize defects. Finally, fiducial marks have been identified as a source of unintentional porosity defects. These results enable the refinement of process parameters, ultimately optimizing LPBF to achieve enhanced material density and expedite the printing.

36 MATERIALS SCIENCE↗

Preface to the JPCM special issue on intense radiation sources in condensed matter and materials physics

This special issue is designed to honour the contributions of our colleague Neville Greaves who was among the first to apply newly-available synchrotron x-ray techniques to study the synthesis, structures and properties of advanced materials [1, 2]. His wide ranging work on ceramics, glasses and nanomaterials was celebrated in a recent issue of the J. Non-Cryst. Solids [3]. Neville's contributions to synchrotron research, highlighted here, focussed on design and construction of new beamline capabilities and sample environments to probe materials under different physical and chemical conditions, integrating various techniques to obtain complementary data on structure and bonding. The innovative nature of his work is illustrated by his studies of liquids and glasses, where he incorporated aerodynamic levitation into these experimental techniques, using both synchrotron x-ray and neutron beams to probe the structural transformations and dynamics combined with molecular dynamics simulations to study atomic scale organisation. His work has had a major impact on fundamental condensed matter physics and chemistry as well as applied materials science; and in this issue, we present contributions from colleagues using and developing new experimental techniques at current and next-generation synchrotron, neutron and free-electron laser sources and in their own laboratories, that probe the fundamental physics, chemistry and functional properties of novel materials and processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Dispersive optical systems for scalable Raman driving of hyperfine qubits

Hyperfine atomic states are among the most promising candidates for qubit encoding in quantum information processing. In atomic systems, hyperfine transitions are typically driven through a two-photon Raman process by a laser field which is amplitude modulated at the hyperfine qubit frequency. Here we introduce a method for generating amplitude modulation by phase modulating a laser and reflecting it from a highly dispersive optical element known as a chirped Bragg grating. This approach is passively stable, offers high efficiency, and is compatible with high-power laser sources, enabling large Rabi frequencies and improved quantum coherence. We benchmark this approach by globally driving an array of approximately 300 neutral 87 Rb atomic qubits trapped in optical tweezers and obtain Rabi frequencies of 2 MHz with photon-scattering error rates of less than 2×10 -4 per π pulse. This robust approach can be directly integrated with local addressing optics in both neutral atom and trapped ion systems to facilitate high-fidelity single-qubit operations for quantum information processing.

74 ATOMIC AND MOLECULAR PHYSICS↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

Drilling of sub-100 μm hourglass-shaped holes in diamond with femtosecond laser pulses

We present images of microholes drilled in diamond using a homemade femtosecond Yb : KGW laser. We use a femtosecond laser source emitting pulses with a duration of 230 fs at a wavelength of 1030 nm, the focusing spot size amounting to 8.9 μm. The effect of the pulse energy and the number of pulses on the microhole geometry (hole diameter, circularity, taper angle, and drilling quality) is evaluated. The obtained results demonstrate the feasibility of drilling of hourglass-shaped holes in a diamond sample, which have similar diameters at the hole entrance (92 μm) and exit (95 μm), but a much smaller diameter (28 μm) at a certain waist section inside the hole. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature distribution in a laser-heated diamond anvil cell as described by finite element analysis

Finite element analysis (FEA) is a powerful tool for numerically solving partial differential equations over complex geometries and is thus useful for analyzing heat transport in laser-heated diamond anvil cell (LHDAC) experiments. Our models expand on previously published simulations by calculating the volume-averaged temperatures of both the sample and insulation/pressure media under steady-state heating to determine the thermal pressure of the hot sample. Our goal is to produce an accurate relationship between the measured surface temperature of the absorbing sample and the temperature of the transparent insulating media, which is used to determine thermal pressure but susceptible to steep temperature gradients. We find that in doing so, our FEA models of temperature within the pressure/insulation media can differ from simplified estimates of temperature gradients by more than a factor of 2. We also explore temperature-dependent and temperature-independent thermal conductivity models and find that the volume-averaged temperatures differ by up to a factor of 1.3, forcing the predicted thermal pressures determined to also differ by up to a factor of 1.5 at a temperature of 2000 K at 50 GPa for neon. Higher temperatures exacerbate this difference. We also find that unintentional asymmetric sample insertion and sample heating, which are common in LHDAC experiments, do not have a first-order effect on volume-averaged temperatures. The FEA models, available in both Python and FlexPDE, are versatile across different sample geometries, materials, and heat source laser shapes.

Farah, Frederick↗

Optical Communications from Planetary Distances

Future planetary campaigns, including human missions, will require data rates difficult to realize by microwave links. Optical channels not only provide an abundance of bandwidth, they also allow for significant size, weight, and power reduction. Moreover, optical-based tracking may enhance spacecraft navigation with respect to microwave-based tracking. With all its advantages, optical communications from deep space is not without its challenges. Due to the extreme distance between the two ends of the link, specialized technologies are needed to enable communications in the deep space environment. Although some of the relevant technologies have been developed in the last decade, they remain to be validated in an appropriate domain. The required assets include efficient pulsed laser sources, modulators, transmitters, receivers, detectors, channel encoders, precise beam pointing technologies for the flight transceiver and large apertures for the ground receiver. Clearly, space qualification is required for the systems that are installed on a deep space probe. Another challenge is atmospheric effects on the optical beam. Typical candidate locations on the ground have a cloud-free line of sight only on the order of 60-70% of the time. Furthermore, atmospheric losses and background light can be problematic even during cloud-free periods. Lastly, operational methodologies are needed for efficient and cost effective management of optical links. For more than a decade, the National Aeronautics and Space Administration (NASA) has invested in relevant technologies and procedures to enable deep space optical communications capable of providing robust links with rates in the order of 1 Gb/s from Mars distance. A recent publication indicates that potential exists for 30-dB improvement in performance through technology development with respect to the state-of-the-art in the early years of this decade. The goal is to fulfill the deep space community needs from about 2020 to the foreseeable future. It is envisioned that, at least initially, optical links will be complemented by microwave assets for added robustness, especially for human missions. However, it is expected that as optical techniques mature, laser communications may be operated without conventional radio frequency links. The purpose of this paper is to briefly review the state-of-the-art in deep space laser communications and its challenges and discuss NASA-supported technology development efforts and plans for deep space optical communications at JPL.

Laser Communications↗

On ultrafast x-ray scattering methods for magnetism

With the introduction of x-ray free electron laser sources around the world, new scientific approaches for visualizing matter at fundamental length and time-scales have become possible. As it relates to magnetism and ‘magnetic-type’ systems, advanced methods are being developed for studying ultrafast magnetic responses on the time-scales at which they occur. We describe three capabilities which have the potential to seed new directions in this area and present original results from each: pump-probe x-ray scattering with low energy excitation, x-ray photon fluctuation spectroscopy, and ultrafast diffuse x-ray scattering. By combining these experimental techniques with advanced modeling together with machine learning, we describe how the combination of these domains allows for a new understanding in the field of magnetism. Finally, we give an outlook for future areas of investigation and the newly developed instruments which will take us there.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

N‐Doping Effects On Electrocatalytic Water Splitting of Non‐Noble High‐Entropy Alloy Nanoparticles Prepared by Inert Gas Condensation

Abstract The unique catalytic activities of high‐entropy alloys (HEAs) emerge from the complex interaction among different elements in a single‐phase solid solution. As a “green” nanofabrication technique, inert gas condensation (IGC) combined with laser source opens up a highly efficient avenue to develop HEA nanoparticles (NPs) for catalysis and energy storage. In this work, the novel N‐doped non‐noble HEA NPs are designed and successfully prepared by IGC. The N‐doping effects of HEA NPs on oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) are systematically investigated. The results show that N‐doping is conducive to improving the OER, but unfavorable for HER activity. The FeCoNiCrN NPs achieve an overpotential of 269.7 mV for OER at a current density of 10 mA cm −2 in 1.0 M KOH solution, which is among the best reported values for non‐noble HEA catalysts. The effects of the differences in electronegativity, ionization energy and electron affinity energy among mixed elements in N‐doped HEAs are discussed as inducing electron transfer efficiency. Combined with X‐ray photoelectron spectroscopy and the extended X‐ray absorption fine structure analysis, an element‐design strategy in N‐doped HEAs electrocatalysts is proposed to improve the intrinsic activity and ameliorate water splitting performance.

Chemistry↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗