Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “landmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Spatial Precision in Magnetic Resonance Imaging–Guided Radiation Therapy: The Role of Geometric Distortion

Because magnetic resonance imaging–guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility–induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility–induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Radiation Therapy for Margin-Positive Vulvar Squamous Cell Carcinoma: Defining the Ideal Dose-Response Using the National Cancer Data Base

Purpose: Positive surgical margins after radical vulvectomy for vulvar cancer portend a high risk for local relapse, which may be challenging to salvage. We assessed the impact of adjuvant radiation therapy (aRT) on overall survival (OS) and the dose-response relationship using the National Cancer Data Base. Methods and Materials: Patients with vulvar squamous cell carcinoma who underwent initial extirpative surgery with positive margins from 1998 to 2012 were included. Factors associated with aRT and specific dose levels were analyzed using logistic regression. Log-rank and multivariable Cox proportional hazards modeling were used for OS analysis. Results: We identified 3075 patients with a median age of 66 years (range, 22-90 years); the median follow-up time was 36.4 months (interquartile range [IQR] 15.4-71.0 months). Stage IA/B disease represented 41.2% of the cohort. Sixty-three percent underwent lymph node assessment, with a 45% positivity rate. In total, 1035 patients (35.3%) received aRT, with a median dose of 54.0 Gy (IQR 48.6-60.0 Gy). The 3-year OS improved from 58.5% to 67.4% with aRT (P<.001). On multivariable analysis, age, Charlson-Deyo score ≥1, stage ≥II, tumors ≥4 cm, no aRT, and adverse nodal characteristics led to inferior survival. Dose of aRT was positively associated with OS as a continuous variable on univariate analysis (P<.001). The unadjusted 3-year OS for dose subsets 30.0 to 45.0 Gy, 45.1 to 53.9 Gy, 54.0 to 59.9 Gy, and ≥60 Gy was 54.3%, 55.7%, 70.1%, and 65.3%, respectively (P<.001). Multivariable analysis using a 4-month conditional landmark revealed that the greatest mortality reduction occurred in cumulative doses ≥54 Gy: 45.1 to 53.9 Gy (hazard ratio [HR] 0.94, P=.373), 54.0 to 59.9 Gy (HR 0.75, P=.024), ≥60 Gy (HR 0.71, P=.015). No survival benefit was seen with ≥60 Gy compared with 54.0 to 59.9 Gy (HR 0.95, P=.779). Conclusions: Patients with vulvar squamous cell carcinoma and positive surgical margins derive an OS benefit from aRT with a seemingly optimal dose in the range of 54.0 to 59.9 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Pediatric Abdominal Organ Motion With a 4-Dimensional Magnetic Resonance Imaging Method

Purpose: To characterize respiration-induced abdominal organ motion in children receiving radiation treatment with a 4-dimensional (4D) magnetic resonance imaging (MRI) method. Methods and Materials: We analyzed free-breathing coronal 4D MRI datasets acquired from 35 patients (aged 1-20 years) with abdominal tumors. A deformable image registration of the 4D MRI datasets was performed to derive motion trajectories of selected anatomic landmarks, from which organ motions were quantified. The association between organ motion and patient characteristics was investigated and compared with previous studies. The relation between patient height and organ motion was further investigated to predict organ motion in prospective patients. Results: Organ motion and its individual variation were reduced in younger patients (eg, kidney peak-to-peak motion <5 mm for all but 1 patient aged ≤8 years), although special motion management may be warranted in some adolescents. The liver and spleen exhibited greater motion than did the kidneys, while intraorgan variation was present. The motions in the liver and kidneys agreed with those reported by the previous 4D computed tomography studies. Individual variations of organ motion in younger patients were due, in part, to changes in respiration rate, which ostensibly reflected the effect of anesthesia. The prediction of organ motion was limited by large individual variations, particularly for older patients. Conclusions: The 4D MRI acquisition method and motion analysis described in this study provide a nonionizing approach to understand age-associated organ motion, which aids in the planning of abdominal radiation therapy for pediatric patients. Use of 4D MRI facilitates monitoring of changes in target motion patterns during treatment courses and in various studies of the effect of organ motion on radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NRG Oncology/RTOG Consensus Guidelines for Delineation of Clinical Target Volume for Intensity Modulated Pelvic Radiation Therapy in Postoperative Treatment of Endometrial and Cervical Cancer: An Update

Accurate target definition is critical for the appropriate application of radiation therapy. In 2008, the Radiation Therapy Oncology Group (RTOG) published an international collaborative atlas to define the clinical target volume (CTV) for intensity modulated pelvic radiation therapy in the postoperative treatment of endometrial and cervical cancer. The current project is an updated consensus of CTV definitions, with removal of all references to bony landmarks and inclusion of the para-aortic and inferior obturator nodal regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality Image Fusion and Planning and Dose Delivery for Radiation Therapy

Image-guided radiation therapy (IGRT) relies on the quality of fused images to yield accurate and reproducible patient setup prior to dose delivery. The registration of 2 image datasets can be characterized as hardware-based or software-based image fusion. Hardware-based image fusion is performed by hybrid scanners that combine 2 distinct medical imaging modalities such as positron emission tomography (PET) and computed tomography (CT) into a single device. In hybrid scanners, the patient maintains the same position during both studies making the fusion of image data sets simple. However, it cannot perform temporal image registration where image datasets are acquired at different times. On the other hand, software-based image fusion technique can merge image datasets taken at different times or with different medical imaging modalities. Software-based image fusion can be performed either manually, using landmarks, or automatically. In the automatic image fusion method, the best fit is evaluated using mutual information coefficient. Manual image fusion is typically performed at dose planning and for patient setup prior to dose delivery for IGRT. The fusion of orthogonal live radiographic images taken prior to dose delivery to digitally reconstructed radiographs will be presented. Although manual image fusion has been routinely used, the use of fiducial markers has shortened the fusion time. Automated image fusion should be possible for IGRT because the image datasets are derived basically from the same imaging modality, resulting in further shortening the fusion time. The advantages and limitations of both hardware-based and software-based image fusion methodologies are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardization of Head and Neck Contouring Using the Acanthiomeatal Line

The purpose of this study was to determine the perceived and actual chin position(s) used for radiotherapy of head-and-neck cancers in a variety of clinical settings. Dosimetrists were asked to describe the external landmarks used to set the chin position. The lateral treatment planning radiographic figures in Ang's textbook, Radiotherapy for Head and Neck Cancers: Indications and Techniques, were analyzed for chin position by drawing a horizontal line from the tip of the chin to the cervical spine. The physicians at 7 departments were asked to rate the chin positions used in their departments for head-and-neck simulations. Choices included: (1) mildly flexed, (2) neutral, (3) mildly extended, and (4) hyperextended. In addition, each center was asked to select 2 representative cases to show routine chin position. The dosimetrists fixed the chin in neutral position by placing a virtual plane defined by 3 points (the base of the nasal septum [acanthus] and the external auditory canals) perpendicular to the table top. The type of head holder was irrelevant. Eighty-two percent (31/38) of the figures in Ang's text showed positioning in the neutral position (tip of the chin intersected the cervical spine between C2-3/C3-4). Most (71.4%) of the radiotherapists thought their patients were treated in the hyperextended neck position but, in fact, 85.7% (12/14) of the simulations showed a neural neck position. Reproducible chin positioning can be obtained by using the acanthiomeatal line. Consistent use of this technique will create a uniformly positioned set of axial co-images that have consistent appearance of avoidance and lymphatic areas. This will simplify contouring on axial computed tomography (CT) images of the neck. Standardizing the chin position is an important step to developing a standardized atlas and developing an information tool for automated contouring.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Four Volume-Based Image Registration Algorithms

We evaluated 4 volume-based automatic image registration algorithms from 2 commercially available treatment planning systems (Philips Syntegra and BrainScan). The algorithms based on cross correlation (CC), local correlation (LC), normalized mutual information (NMI), and BrainScan mutual information (BSMI) were evaluated with: (1) the synthetic computed tomography (CT) images, (2) the CT and magnetic resonance (MR) phantom images, and (3) the CT and MR head image pairs from 12 patients with brain tumors. For the synthetic images, the registration results were compared with known transformation parameters, and all algorithms achieved accuracy of submillimeter in translation and subdegree in rotation. For the phantom images, the registration results were compared with those provided by frame and marker-based manual registration. For the patient images, the results were compared with anatomical landmark-based manual registration to qualitatively determine how the results were close to a clinically acceptable registration. NMI and LC outperformed CC and BSMI, with the sense of being closer to a clinically acceptable result. As for the robustness, NMI and BSMI outperformed CC and LC. A guideline of image registration in our institution was given, and final visual assessment is necessary to guarantee reasonable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance. The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

Targeting accuracy of single-isocenter intensity-modulated radiosurgery for multiple lesions

To investigate the targeting accuracy of intensity-modulated SRS (IMRS) plans designed to simultaneously treat multiple brain metastases with a single isocenter. A home-made acrylic phantom able to support a film (EBT3) in its coronal plane was used. The phantom was CT scanned and three coplanar small targets (a central and two peripheral) were outlined in the Eclipse system. Peripheral targets were 6 cm apart from the central one. A reference IMRS plan was designed to simultaneously treat the three targets, but only a single isocenter located at the center of the central target was used. After positioning the phantom on the linac using the room lasers, a CBCT scan was acquired and the reference plan were mapped on it, by placing the planned isocenter at the intersection of the landmarks used in the film showing the linac isocenter. The mapped plan was then recalculated and delivered. The film dose distribution was derived using a cloud computing application ( (www.radiochromic.com)) that uses a triple-channel dosimetry algorithm. Comparison of dose distributions using the gamma index (5%/1 mm) were performed over a 5 × 5 cm{sup 2} region centered over each target. 2D shifts required to get the best gamma passing rates on the peripheral target regions were compared with the reported ones for the central target. The experiment was repeated ten times in different sessions. Average 2D shifts required to achieve optimal gamma passing rates (99%, 97%, 99%) were 0.7 mm (SD: 0.3 mm), 0.8 mm (SD: 0.4 mm) and 0.8 mm (SD: 0.3 mm), for the central and the two peripheral targets, respectively. No statistical differences (p > 0.05) were found for targeting accuracy between the central and the two peripheral targets. The study revealed a targeting accuracy within 1 mm for off-isocenter targets within 6 cm of the linac isocenter, when a single-isocenter IMRS plan is designed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Variations of target volume definition and daily target volume localization in stereotactic body radiotherapy for early-stage non–small cell lung cancer patients under abdominal compression

We aimed to compare gross tumor volumes (GTV) in 3-dimensional computed tomography (3DCT) simulation and daily cone beam CT (CBCT) with the internal target volume (ITV) in 4-dimensional CT (4DCT) simulation in stereotactic body radiotherapy (SBRT) treatment of patients with early-stage non–small cell lung cancer (NSCLC) under abdominal compression. We retrospectively selected 10 patients with NSCLC who received image-guided SBRT treatments under abdominal compression with daily CBCT imaging. GTVs were contoured as visible gross tumor on the planning 3DCT and daily CBCT, and ITVs were contoured using maximum intensity projection (MIP) images of the planning 4DCT. Daily CBCTs were registered with 3DCT and MIP images by matching of bony landmarks in the thoracic region to evaluate interfractional GTV position variations. Relative to MIP-based ITVs, the average 3DCT-based GTV volume was 66.3 ± 17.1% (range: 37.5% to 92.0%) (p < 0.01 in paired t-test), and the average CBCT-based GTV volume was 90.0 ± 6.7% (daily range: 75.7% to 107.1%) (p = 0.02). Based on bony anatomy matching, the center-of-mass coordinates for CBCT-based GTVs had maximum absolute shift of 2.4 mm (left-right), 7.0 mm (anterior-posterior [AP]), and 5.2 mm (superior-inferior [SI]) relative to the MIP-based ITV. CBCT-based GTVs had average overlapping ratio of 81.3 ± 11.2% (range: 45.1% to 98.9%) with the MIP-based ITV, and 57.7 ± 13.7% (range: 35.1% to 83.2%) with the 3DCT-based GTV. Even with abdominal compression, both 3DCT simulations and daily CBCT scans significantly underestimated the full range of tumor motion. In daily image-guided patient setup corrections, automatic bony anatomy-based image registration could lead to target misalignment. Soft tissue-based image registration should be performed for accurate treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Turbulence theories and statistical closure approaches

When discussing research in physics and in science more generally, it is common to ascribe equal importance to the three components of the scientific trinity: theoretical, experimental, and computational studies. This review will explore the future of modern turbulence theory by tracing its history, which began in earnest with Kolmogorov’s 1941 analysis of turbulence cascade and inertial range [A.N. Kolmogorov, Dokl. Akad. Nauk SSSR, 30, 299, (1941); 32, 19, (1941)]. The 80th Anniversary of Kolmogorov’s landmark study is a welcome opportunity to survey the achievements and evaluate the future of the theoretical approach of turbulence research. Over the years, turbulence theories have been critically important in laying the foundation of our understanding of the nature of turbulent flows. In particular, the Direct Interaction Approximation (DIA) [R.H. Kraichnan, J. Fluid Mech., 5, 497 (1959)] and its subsequent development, known as the statistical closure approach, can be identified as perhaps the most profound single advancement. The remarkable success of the statistical closure has furnished a platform to study such essential concepts as the energy transfer process and interacting scales, and the roles of the straining and sweeping motions. More recently, the quasi-Lagrangian formulation of V. L’vov & I. Procaccia and Kraichnan’s solvable passive scalar model provided powerful ways to explore another fundamental aspect of turbulent flows, the phenomena of intermittency, and the associated anomalous scaling exponents. In the meantime, the theory of fluid equilibria has been developed to describe the large-scale structures that can emerge from turbulent cascades of two-dimensional and geophysical flows at a later time. And yet, despite all these successes, analytical treatments suffer from mathematical complexities. As a result, the utility of theoretical approaches has been limited to relatively idealized flows. On the other hand, in recent decades, computational abilities and experimental facilities have reached an unprecedented scale. Looking beyond the horizon, the imminent deployment of exascale supercomputers will generate complete datasets of the entire flow field of key benchmark flows, allowing researchers to extract additional measurements concerning fully developed, complex turbulent flow fields far beyond those available from the statistical closure theories. Some other developments that could potentially influence the future course of turbulence theories include the advancement of machine learning, artificial intelligence, and data science; likely disruptions arising from the advent of quantum computation; and the increasingly prominent role of turbulence research in providing more accurate climate scientific data. Finally, turbulence theorists can leverage these developments by asking the right questions and developing advanced, sophisticated frameworks that will be able to predict and correlate vast amounts of data from the other two components of the trinity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Earth's record-high greenness and its attributions in 2020

Terrestrial vegetation is a crucial component of Earth's biosphere, regulating global carbon and water cycles and contributing to human welfare. Despite an overall greening trend, terrestrial vegetation exhibits a significant inter-annual variability. The mechanisms driving this variability, particularly those related to climatic and anthropogenic factors, remain poorly understood, which hampers our ability to project the long-term sustainability of ecosystem services. Here, in this work, by leveraging diverse remote sensing measurements, we pinpointed 2020 as a historic landmark, registering as the greenest year in modern satellite records from 2001 to 2020. Using ensemble machine learning and Earth system models, we found this exceptional greening primarily stemmed from consistent growth in boreal and temperate vegetation, attributed to rising CO 2 levels, climate warming, and reforestation efforts, alongside a transient tropical green-up linked to the enhanced rainfall. Contrary to expectations, the COVID-19 pandemic lockdowns had a limited impact on this global greening anomaly. Our findings highlight the resilience and dynamic nature of global vegetation in response to diverse climatic and anthropogenic influences, offering valuable insights for optimizing ecosystem management and informing climate mitigation strategies.

54 ENVIRONMENTAL SCIENCES↗

Dermatotoxicology: Historical perspective and advances

The fundamental principles underlying the study of dermatotoxicology were developed by Arnold Lehman and John Draize over a half century ago and remain applicable today. This discipline has proven indispensable for addressing the problems associated with skin exposure to chemicals. The 55th anniversary of Lehman's landmark publication on safety factors presents the opportunity to reflect upon the historical beginnings of dermatotoxicology and the role of regulatory policies on the development of this field over the years. The complexity and sheer volume of information that has been collected makes it difficult to comprehensively cover all aspects of this vast discipline. This overview will touch upon the general concepts of ADME, the various forms of contact dermatitis, and transdermal drug delivery systems. The traditional tests performed in animals and humans to identify allergic or irritant potential of chemicals, in addition to alternative methods such as QSAR modeling will be discussed. The subspecialties of infant and occupational dermatotoxicology, as well as dermatotoxicology of aged and ethnic skin, and skin of the vulva and vagina will also be noted.

60 APPLIED LIFE SCIENCES↗

Occludin induces microvillus formation via phosphorylation of ezrin in a mouse hepatic cell line

Highlights: • The microvillus formation was decreased in occludin knockout cells. • Phosphorylation of ezrin was decreased in occludin knockout cells. • The microvillus formation were increased by transfection of occludin. • Phosphorylation of ezrin was increased by transfection of occludin. Apical and basolateral cell membranes are separated by tight junctions (TJs). Microvilli are limited to the apical cell membrane. TJs and microvilli are the landmarks for epithelial cell polarity. However, the direct relationship between TJ proteins (TJPs) and the components of microvilli remains unclear. In this study, we investigated whether occludin, which is considered to be a functional TJP, is involved in microvillus formation. In occludin knockout mouse hepatic cells (OcKO cells), the microvillus density was less than that in wild-type (WT) cells and the length of microvilli was short. Immunoreactivity of ezrin was decreased in OcKO cells compared with that in WT cells. Although there was no change in the expression level of ezrin, phosphorylation of ezrin was decreased in OcKO cells. The microvillus density and the length of microvilli were increased in OcKO cells by transfection of full-length mouse occludin and COOH-terminal domains of occludin. These results suggested that occludin induced microvillus formation via phosphorylation of ezrin and that the COOH-terminal domain of occludin, which is localized in non-TJ areas, might be able to induce microvilli formation. Our results provide new insights into the function of occludin.

60 APPLIED LIFE SCIENCES↗

Cadherin profiling for therapeutic interventions in Epithelial Mesenchymal Transition (EMT) and tumorigenesis

The major hallmarks of Epithelial-Mesenchymal Transition (EMT) is the loss of epithelial cell polarity and loss of expression of the cell- cell adhesion molecule like E-cadherin and acquired mesenchymal cells marker called N-Cadherin. This phenotypical changes of E-M plasticity of cells is extensively considered to be a crucial factor for tumor cells invasion and cancer metastasis; landmark events for transforming a locally growing tumor (benign tumor) into a systemic and live-threatening disease (malignant tumor). Cadherin molecules are adherens junction proteins and expressed as multiple isoforms. Cadherin switching occurs during normal tissue developmental processes; also recapitulates the increasing aggressive behavior and metastatic nature of cancer cells when E-Cadherin converts to N-Cadherin, in particular. There are several mechanisms established that cadherin switching and some of the underlying pathways involves multiple steps associated with migration and invasion of cancer cells, and finally colonization of micro metastatic lesions to form macro-metastasis. Inhibition of metastasis is complicated by the plasticity of cancer cells behaviors and the evolving nature of microenvironment. Although there is no clear evidence how that dynamic structural switching of cadherin family member occurs, stabilized and eventually influence cell behavior, phenotypic transformations and initiate tumorigenesis. Therefore, we emphasize here the major functions of over 20 existing human cadherins in tissue integrity and stability as well as mechanistic understanding on recent work of cadherin ectodomain-mediated adhesion, functional studies of the cell-cell adhesion through key signaling intermediates interacting with other binding partners. We hope understanding on how the dynamic all existing cadherins influence the cell behavior can be targeted to design possible therapeutic interventions to combat its activity and prevent tumor cell growth, invasion and metastasis.

60 APPLIED LIFE SCIENCES↗

Rational Design of Pore Size and Functionality in a Series of Isoreticular Zwitterionic Metal–Organic Frameworks

The isoreticular expansion and functionalization of charged-polarized porosity has been systematically explored by the rational design of 11 isostructural zwitterionic metal-organic frameworks (ZW-MOFs). This extended series of general structural composition {[M 3 F(L1) 3 (L2) 1.5 ]·guests} n was prepared by employing the solvothermal reaction of Co and Ni tetrafluoroborates with a binary ligand system composed of zwitterionic pyridinium derivatives and traditional functionalized ditopic carboxylate auxiliary ligands (HL1·Cl = 1-(4-carboxyphenyl)-4,4'-bipyridinium chloride, Hcpb·Cl; or 1-(4-carboxyphenyl-3-hydroxyphenyl)-4,4'-bipyridinium chloride, Hchpb·Cl; and H 2 L2 = benzene-1,4-dicarboxylic acid, H 2 bdc; 2-aminobenzene-1,4-dicarboxylic acid, H 2 abdc; 2,5-dihydroxy-1,4-benzenedicarboxylic acid, H 2 dhbdc; biphenyl-4,4'-dicarboxylic acid, H 2 bpdc; or stilbene-4,4'-dicarboxylic acid, H 2 sdc). Single-crystal structure analyses revealed cubic crystal symmetry ( I -43 m , a = 31-36 Å) with a 3D pore system of significant void space (73-81%). The pore system features three types of pores being systematically tunable in size ranging from 17.4 to 18.8 Å (pore I), 8.2 to 12.8 Å (pore II), and 4.8 to 10.4 Å (pore III) by the choice of auxiliary ligands. All members of this series have noninterpenetrating structures and exhibit robust architectures, as evidenced by their permanent porosity and high thermal stability (up to 300 °C). The structural integrity and specific surface areas could be systematically optimized using supercritical CO 2 exchange methods for framework activation resulting in BET surface areas ranging from 1250 to 2250 m 2 /g. Most interestingly, as a structural landmark, we found the pore surfaces lined with charge gradients employed by the pyridinium ligands. This key feature results in significant adsorption of carbon dioxide and methane which is attributed to polarization effects. With this contribution we pioneer the reticulation of pyridinium building blocks into extended zwitterionic networks in which specific properties can be targeted.

36 MATERIALS SCIENCE↗

First-Principles Models for van der Waals Interactions in Molecules and Materials: Concepts, Theory, and Applications

Noncovalent van der Waals (vdW) or dispersion forces are ubiquitous in nature and influence the structure, stability, dynamics, and function of molecules and materials throughout chemistry, biology, physics, and materials science. These forces are quantum mechanical in origin and arise from electrostatic interactions between fluctuations in the electronic charge density. Here, we explore the conceptual and mathematical ingredients required for an exact treatment of vdW interactions, and present a systematic and unified framework for classifying the current first-principles vdW methods based on the adiabatic-connection fluctuation–dissipation (ACFD) theorem (namely the Rutgers–Chalmers vdW-DF, Vydrov–Van Voorhis (VV), exchange-hole dipole moment (XDM), Tkatchenko–Scheffler (TS), many-body dispersion (MBD), and random-phase approximation (RPA) approaches). Particular attention is paid to the intriguing nature of many-body vdW interactions, whose fundamental relevance has recently been highlighted in several landmark experiments. The performance of these models in predicting binding energetics as well as structural, electronic, and thermodynamic properties is connected with the theoretical concepts and provides a numerical summary of the state-of-the-art in the field. We conclude with a roadmap of the conceptual, methodological, practical, and numerical challenges that remain in obtaining a universally applicable and truly predictive vdW method for realistic molecular systems and materials.

Hermann, Jan↗