Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laboratory evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Modeling Protocol for Evaluation of Air Emissions for the Idaho National Laboratory Site-wide Permit to Construct and Facility Emission Cap (PTC/FEC)

This document outlines the methods to be used for calculating non-radiological air quality impacts from proposed emissions at the Idaho National Laboratory (INL) Site in support of applying for a renewal to a Permit to Construct with a Facility Emissions Cap (PTC/FEC). The INL Site is seeking to maintain a state enforceable limit on emissions to maintain synthetic minor status in accordance with Idaho Administrative Procedures Act (IDAPA) 58.01.01.175-181 and IDAPA 58.01.01.200-228.

54 ENVIRONMENTAL SCIENCES↗

Flexible, Multipurpose Laboratory Advances Building and Thermal Energy Systems: Expanding Evaluation and Development of Grid-Interactive Buildings

Robust hardware and controls are necessary to ensure results match their intent before they can be used broadly. However, this often requires multiple field experiments in a variety of climate zones. In the field, it is more difficult to obtain information on other important factors, such as thermal, grid, and occupant interaction. Gaps also exist in understanding the performance degradation and life cycle of thermal energy systems as they relate to buildings. There is a lack of robust, high-quality performance data for projects at scale; this data can be expensive to produce and often remain proprietary.

30 DIRECT ENERGY CONVERSION↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

2021 Consequence Management Hotline Drill After Action Report

In March 2021, a functional area drill was held at the Remote Sensing Laboratory–Nellis that focused on using CBRNResponder and the Digital Field Monitoring (DFM) tablets for sample hotline operations and the new paper Sample Control Forms (SCFs) for sample collection. Participants included staff trained and billeted as sample control specialists and Consequence Management Response Team (CMRT) field monitoring personnel. Teams were able to successfully gather and transfer samples to the sample control hotline staff through the manual process, though there were several noted areas for improvement. In July and October 2021, two additional functional area drills were held at Sandia National Laboratories that focused on field sample collection and custody transfer at the sample control hotline for the Consequence Management (CM) Radiological Assistance Program (RAP) program. The overarching goal of the drills was to evaluate the current CM process for sample collection, sample drop off, and sample control using the CBRNResponder mobile and web-based applications. The July 2021 drill had an additional focus to have a subset of samples analyzed by the local analytical laboratory, Radiation Protection Sample Diagnostics (RPSD) laboratory, to evaluate the Laboratory Access portal on CBRNResponder. All three drills were able to accomplish their objectives however, there were several issues noted (Observations: 25 Urgent, 29 Important, and 22 Improvement Opportunities). The observations were prioritized according to their impact on the mission as well as categorized to align with the programmatic functional area required to address the issue. This report provides additional detail on each observation for skillset/program leads and software developers to consider for future improvement or mandatory efforts.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

Field Performance of R-1234yf Heat Pump Water Heaters

Heat pump water heaters (HPWH) provide a resource for increasing water heating efficiency in U.S. residences. Electric HPWHs have traditionally utilized R-134a as the refrigerant in the vapor-compression cycle; however, this refrigerant is undesirable long-term due to its high global warming potential. For HPWHs, low global warming potential refrigerants such as R-1234yf may offer comparable performance, but the evaluation of these systems has been limited to laboratory settings. This study provides field evaluations of off-the-shelf HPWHs that had their factory R-134a refrigerant replaced with an optimized charge of R-1234yf. The field evaluation consisted of R-1234yf HPWHs at two occupied field sites and two unoccupied, simulated lab homes. At the two residential field sites with occupants, the R-1234yf HPWHs operated issue-free for the 18-month field trial, and the home occupants perceived no change in HPWH performance relative to their prior R-134a HPWHs. At the lab homes, under simulated hot water draws, the average daily operating efficiency of the R-1234yf HPWH was within 2% of the baseline R-134a HPWHs.

42 ENGINEERING↗

Comparative Critical Mass Calculations for NNL and ENDF/B-VIII.0 Zirconium Hydride Thermal Neutron Scattering Laws

Zirconium hydride (ZrH x ) is a moderator material for TRIGA reactors and historical space reactor systems, such as SNAP-10A. Thermal neutron scattering laws (TSL) for two phases of this material, δ and ε, have been previously evaluated by Naval Nuclear Laboratory (NNL) and submitted to the National Nuclear Data Center (NNDC) for inclusion in the US national ENDF/B-VIII.1 nuclear data library. In contrast to the current ENDF/B-VIII.0 TSL evaluations, which consider only a single phase, the new evaluations are derived from separate ab initio calculations for both phases and include coherent elastic effects of the zirconium sublattice. To estimate the impact of these changes to the TSL evaluation of this material, comparative critical mass calculations were performed with MC21 for homogenous mixtures of high- enriched uranium (HEU) and ZrH x in bare and water reflected sphere configurations. These calculations yield an impact on the estimated critical mass as a function of 235 U loading density with maximum differences as large as 1% - 5% for over-moderated thermal spectrum systems. Consequently, the NNL TSL evaluations are anticipated to have a small impact on criticality calculations of thermal reactor systems regardless of the material phase. Nevertheless, characteristic differences exist in the predicted thermal spectra as function of energy for the two sets of TSL evaluations, which are attributed to difference in the underlying phonon density of states of hydrogen bound in ZrH x .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NGEE Arctic Rainfall Simulator Validation Data from Los Alamos National Laboratory, New Mexico, Summer 2022

Experiments evaluating the uniformity and intensity of rainfall produced by the NGEE Arctic Rainfall Simulator (NARS) were conducted at Los Alamos National Laboratory, New Mexico, over summer 2022. Petri dishes were placed in a grid within the NARS plot. Simulated rainfall was collected in each petri dish and the intensity and uniformity of the simulator was subsequently calculated. This data package contains two .csv files, one that summarizes the rainfall intensity and uniformity for each experiment, the other that contains individual petri dish water volume and intensity for each plot location and experiment. The Python scripts to control NARS are also included. The NGEE Arctic Rainfall Simulator (NARS) is a variable intensity rainfall simulator (RFS) with a frame design based on the Humphry et al. (2002) RFS and a water delivery system based on the Walnut Gulch (Paige et al., 2004) RFS. The NARS uses an aluminum frame that is fully deconstructable for transportation to field locations and a water system that enables variable rain intensity. Rain intensity control and data collection are automated using a Raspberry Pi microcomputer. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Comparative critical mass calculations for NNL and ENDF/B-VIII.0 - Zirconium hydride thermal neutron scattering laws

Zirconium hydride (ZrH{sub x}) is a moderator material for TRIGA reactors and historical space reactor systems, such as SNAP-10A. Thermal neutron scattering laws (TSL) for two phases of this material, δ and ε, have been previously evaluated by Naval Nuclear Laboratory (NNL) and submitted to the National Nuclear Data Center (NNDC) for inclusion in the US national ENDF/B-VIII.1 nuclear data library. In contrast to the current ENDF/B-VIII.0 TSL evaluations, which consider only a single phase, the new evaluations are derived from separate ab initio calculations for both phases and include coherent elastic effects of the zirconium sublattice. To estimate the impact of these changes to the TSL evaluation of this material, comparative critical mass calculations were performed with MC21 for homogenous mixtures of high-enriched uranium (HEU) and ZrH{sub x} in bare and water reflected sphere configurations. These calculations yield an impact on the estimated critical mass as a function of {sup 235}U loading density with maximum differences as large as 1% - 5% for over-moderated thermal spectrum systems. Consequently, the NNL TSL evaluations are anticipated to have a small impact on criticality calculations of thermal reactor systems regardless of the material phase. Nevertheless, characteristic differences exist in the predicted thermal spectra as function of energy for the two sets of TSL evaluations, which are attributed to difference in the underlying phonon density of states of hydrogen bound in ZrH{sub x}. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MFC and Fuel Evaluation for KSU

Idaho National Laboratory's Materials and Fuels Complex is well equipped for research, development, and demonstration of nuclear fuel designs and reactor components. The capabilities for fuels RD&D at MFC are briefly presented and the observation of fuel behavior that merit RD&D at MFC are introduced, with emphasis on metal fast reactor fuel.

Materials and Fuels Complex↗

Temporal and Spatial Evolution of Non-Elastic Strain Accumulation in Stanstead Granite During Brittle Creep

Understanding the long-term behavior of brittle rocks requires fundamental consideration of time-dependent strain evolution and brittle creep processes. Previous studies have evaluated sub-critical crack growth during time-dependent deformation and damage evolution in brittle rocks; however, there is an incomplete knowledge of how damage evolves spatially and temporally within the body of intact rocks, where distributed regions of damage interact and coalesce during creep. This paper presents laboratory research focusing on evaluating brittle creep damage processes in Stanstead granite (SG) using 2-dimensional digital image correlation (2D-DIC). In the laboratory, the prismatic SG specimens were loaded beyond an estimated Crack Damage stress threshold (CD) level and then maintained a constant stress to initiate the creep process. DIC was used to characterize full-field spatiotemporal strain evolution, which was then interpreted in the context of local regions of “damage”, determined according to a strain-based criterion. Here, a method was proposed for identifying “existing” and “new” damage regions over specified intervals during the test, followed by spatial clustering of these regions to assess their spatiotemporal evolution. The clustering analysis results demonstrated the extension of existing damage regions was the main damage process during brittle creep, which is consistent with existing models of sub-critical crack growth. In addition, temporal analysis of tensile and shear strains on a point-by-point basis revealed both new damage formation and the strain concentration within existing damaged regions significantly contribute to overall specimen strain during primary creep. In contrast, during secondary creep, increases in specimen deformation are influenced by the accumulation of strains within already damaged regions.

58 GEOSCIENCES↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wetland Re-Evaluation and Delineation Report for the Los Alamos National Laboratories Wetlands Project, Los Alamos County, New Mexico

In March of 2005, the Department of Energy (DOE), National Nuclear Security Administration (NNSA), Los Alamos Site office (LASO) requested the U.S. Army Corps of Engineers Albuquerque District (USACE) to identify and delineate wetlands at Los Alamos National Laboratory (LANL). The results of this study were intended to support the preparation of the Supplemental Site-Wide Environmental Impact Statement (EIS) and various mitigative measures that would become part of the National Environmental Policy Act (NEPA) compliance process for LANL. The term “wetland” will be used throughout the report to refer to the potential wetlands listed in Table 1. Many of these potential "wetlands” were not determined to be wetlands based on 2025 data.

60 APPLIED LIFE SCIENCES↗

Demonstration and Evaluation of Lightweight High Performance Secondary Windows

Eight secondary windows (single-pane and double-pane) were installed at Building 53 of the Denver Federal Center in Colorado as part of a demonstration project to assess their thermal performance, life cycle costs, and deployment potential for use in conjunction with existing, older single-pane windows. The U.S. Department of Energy's National Renewable Energy Laboratory performed several different evaluations to assess the viability of the secondary windows for GSA applications. Some assessments were performed with models, while others required onsite evaluations including time series measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗