Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion beam analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS

Accurate and precise lithium isotopic composition measurements are achieved on the Neoma MS/MS after careful tuning of the prefilter lenses to allow both Li ion beams to pass through unimpeded.

07 ISOTOPE AND RADIATION SOURCES↗

Jet-hadron correlations with respect to the event plane in $\sqrt{s_{NN}}$ = 200 GeV Au + Au collisions in STAR

Angular distributions of charged particles relative to jet axes are studied in $\sqrt{s_{NN}}$ = 200 GeV Au+Au collisions as a function of the jet orientation with respect to the event plane. This differential study tests the expected path-length dependence of energy loss experienced by a hard-scattered parton as it traverses the hot and dense medium formed in heavy-ion collisions. A second-order event plane is used in the analysis as an experimental estimate of the reaction plane formed by the collision impact parameter and the beam direction. Charged-particle jets with 15 < 𝑝 T,jet < 20 and 20 < 𝑝 T,jet < 40 ⁢GeV/𝑐 were reconstructed with the anti-𝑘 T algorithm with radius parameter setting of 𝑅 = 0.4 in the 20–50% centrality bin to maximize the initial-state eccentricity of the interaction region. The reaction plane fit method is implemented to remove the flow-modulated background with better precision than prior methods. Yields and widths of jet-associated charged-hadron distributions are extracted in three angular bins between the jet axis and the event plane. The event-plane (EP) dependence is further quantified by ratios of the associated yields in different EP bins. No dependence on orientation of the jet axis with respect to the event plane is seen within the uncertainties in the kinematic regime studied. This finding is consistent with a similar experimental observation by ALICE in $\sqrt{s_{NN}}$ = 2.76 TeV Pb-Pb collision data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Overview of the Nuclear Electric Xenon Ion System (NEXIS) Activity

The Nuclear Electric Xenon Ion System (NEXIS) research and development activity within NASA's Project Prometheus, was one of three proposals selected by NASA to develop thruster technologies for long life, high power, high specific impulse nuclear electric propulsion systems that would enable more robust and ambitious science exploration missions to the outer solar system. NEXIS technology represents a dramatic improvement in the state-of-the-art for ion propulsion and is designed to achieve propellant throughput capabilities >= 2000 kg and efficiencies >= 78% while increasing the thruster power to >= 20 kW and specific impulse to >= 6000 s. The NEXIS technology uses erosion resistant carbon-carbon grids, a graphite keeper, a new reservoir hollow cathode, a 65-cm diameter chamber masked to produce a 57-cm diameter ion beam, and a shared neutralizer architecture to achieve these goals. The accomplishments of the NEXIS activity so far include performance testing of a laboratory model thruster, successful completion of a proof of concept reservoir cathode 2000 hour wear test, structural and thermal analysis of a completed development model thruster design, fabrication of most of the development model piece parts, and the nearly complete vacuum facility modifications to allow long duration wear testing of high power ion thrusters.

ion thrusters↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Whistler Waves Associated With Electron Beams in Magnetopause Reconnection Diffusion Regions

Abstract Whistler waves are often observed in magnetopause reconnection associated with electron beams. We analyze seven MMS crossings surrounding the electron diffusion region (EDR) to study the role of electron beams in whistler excitation. Waves have two major types: (a) Narrow‐band waves with high ellipticities and (b) broad‐band waves that are more electrostatic with significant variations in ellipticities and wave normal angles. While both types of waves are associated with electron beams, the key difference is the anisotropy of the background population, with perpendicular and parallel anisotropies, respectively. The linear instability analysis suggests that the first type of wave is mainly due to the background anisotropy, with the beam contributing additional cyclotron resonance to enhance the wave growth. The second type of broadband waves are excited via Landau resonance, and as seen in one event, the beam anisotropy induces an additional cyclotron mode. The results are supported by particle‐in‐cell simulations. We infer that the first type occurs downstream of the central EDR, where background electrons experience Betatron acceleration to form the perpendicular anisotropy; the second type occurs in the central EDR of guide field reconnection. A parametric study is conducted with linear instability analysis. A beam anisotropy alone of above ∼3 likely excites the cyclotron mode waves. Large beam drifts cause Doppler shifts and may lead to left‐hand polarizations in the ion frame. Future studies are needed to determine whether the observation covers a broader parameter regime and to understand the competition between whistler and other instabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Dual ion beam deposition of carbon films with diamondlike properties

A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamondlike films generated by sputtering a graphite target.

Mirtich, M. J.↗

Sixty GHz IMPATT diode development

The objective of this program is to develop 60 GHz GaAs IMPATT Diodes suitable for communications applications. The performance goal of the 60 GHz IMPATT is 1W CW output power with a conversion efficiency of 15 percent and 10 year life time. During the course of the program, double drift (DD) GaAs IMPATT Diodes have been developed resulting in the state of the art performance at V band frequencies. A CW output power of 1.12 W was demonstrated at 51.9 GHz with 9.7 percent efficiency. The best conversion efficiency achieved was 15.3 percent. V band DD GaAs IMPATTs were developed using both small signal and large signal analyses. GaAs wafers of DD flat, DD hybrid, and DD Read profiles using molecular beam epitaxy (MBE) were developed with excellent doping profile control. Wafer evaluation was routinely made by the capacitance versus voltage (C-V) measurement. Ion mass spectrometry (SIMS) analysis was also used for more detailed profile evaluation.

Ma, Y. E.↗

Dual-ion-beam deposition of carbon films with diamond-like properties

A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamond like films generated by sputtering a graphite target.

Mirtich, M. J.↗

Comparison of short-range order in irradiated dysprosium titanates

Abstract The structural response of Dy 2 TiO 5 oxide under swift heavy ion irradiation (2.2 GeV Au ions) was studied over a range of structural length scales utilizing neutron total scattering experiments. Refinement of diffraction data confirms that the long-range orthorhombic structure is susceptible to ion beam-induced amorphization with limited crystalline fraction remaining after irradiation to 8 × 10 12 ions/cm 2 . In contrast, the local atomic arrangement, examined through pair distribution function analysis, shows only subtle changes after irradiation and is still described best by the original orthorhombic structural model. A comparison to Dy 2 Ti 2 O 7 pyrochlore oxide under the same irradiation conditions reveals a different behavior: while the dysprosium titanate pyrochlore is more radiation resistant over the long-range with smaller degree of amorphization as compared to Dy 2 TiO 5 , the former involves more local atomic rearrangements, best described by a pyrochlore-to-weberite-type transformation. These results highlight the importance of short-range and medium-range order analysis for a comprehensive description of radiation behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanotomography for Quantitative 3D Particle Reconstruction

Particulates are ubiquitous across fuel cycle operations and carry critical information about particle formation, processing, and potential proliferation-related activities. Traditional analytical techniques, including micro-Raman spectroscopy and standard electron microscopy, are often limited in spatial resolution or dimensionality, particularly when used to examine metallic or submicron-scale features. Understanding particle morphology, phase distribution, and internal porosity is essential for constraining formation conditions, thermodynamic environments, and material transport behavior. In this report, we demonstrate the application of plasma focused ion beam nanotomography to reconstruct micron-scale particulates at nanoscale resolution. Using high-resolution backscattered electron imaging and Avizo software, we obtained 3D reconstructions that enabled quantitative analysis of particle morphology, phase composition, and internal voids. Representative examples include a Ta particle with a large central void and a composite particle with embedded tetrahedral crystalline structures. These reconstructions reveal structural and compositional details that are inaccessible through conventional 2D imaging. The results demonstrate that nanotomography provides both qualitative and quantitative insights into particle formation and behavior. Using nanotomography, porosity and phase distributions can be quantified to inform models of particle density, transport, and solidification conditions. Beyond technical insights, the workflow developed here establishes a transferable capability for analyzing heterogeneous particles and has potential applications in bulk materials studies via x-ray computed tomography or other volumetric imaging modalities. Ongoing efforts are focused on optimizing the workflow to process multiple particles simultaneously, increasing throughput and statistical robustness. Overall, this work illustrates the power of nanotomography as a tool for connecting particulate morphology to formation mechanisms, composition, and transport, thereby strengthening analytical capabilities for nuclear forensics, fuel cycle analysis, and related scientific investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.↗

Demonstration of and future perspective on scaling ultrafast-laser-ablation microstructuring of Li-ion battery electrodes to roll-to-roll production and large-format cells

This work demonstrates integration of an ultrafast laser onto a roll-to-roll machine, the laser structuring of a double-sided, 700 m long roll of graphite battery anode and its subsequent manufacture into 27 Ah prismatic cells. The electrode was ablated with a novel hybrid-microstructure composed of both hexagonally arranged pores for enhanced rate performance and channels for fast electrolyte wetting. Subsequently, this anode and a non-ablated baseline anode are paired with an NMC111 cathode for cell building and electrochemical characterization. Compared to the baseline, laser ablated cells demonstrated a reduction in soaking time of at least 60%, an improvement in fast charge capability with >30% more capacity accepted during 6C charging, and an extension of cycle life of >40% during 0.5C cycling. Further, a perspective is provided on scaling ultrafast laser ablation of battery electrodes to industrial throughputs. Additionally, lessons learned from this pilot-scale demonstration are provided in regards to optical architecture, debris removal, and system control. A techno-economic analysis is used to demonstrate that laser ablation can be integrated into existing electrode manufacturing facilities with only ≈$\$$1.3 per kWh increase (≈2%) in manufacturing cost. Preemptive electrode design for laser ablation is discussed as a further method for enhancing performance. Finally, an analysis of available laser systems and beam-scanning architectures is used to determine design requirements to scale process throughput to a state-of-the-art speed of 50 m min −1 . This analysis demonstrates that laser ablating Li-ion battery electrodes has multiple benefits to manufacturing and battery performance, that the technology already exists to achieve high laser-ablation throughputs, and that integrating ultrafast laser ablation to electrode manufacturing will not create a cost or processing bottleneck.

25 ENERGY STORAGE↗

Characterization of Meteorites by Focused Ion Beam Sectioning: Recent Applications to CAIs and Primitive Meteorite Matrices

Focused ion beam (FIB) sectioning has revolutionized preparation of meteorite samples for characterization by analytical transmission electron microscopy (TEM) and other techniques. Although FIB is not "non-destructive" in the purest sense, each extracted section amounts to no more than nanograms (approximately 500 cubic microns) removed intact from locations precisely controlled by SEM imaging and analysis. Physical alteration of surrounding material by ion damage, fracture or sputter contamination effects is localized to within a few micrometers around the lift-out point. This leaves adjacent material intact for coordinate geochemical analysis by SIMS, microdrill extraction/TIMS and other techniques. After lift out, FIB sections can be quantitatively analyzed by electron microprobe prior to final thinning, synchrotron x-ray techniques, and by the full range of state-of-the-art analytical field-emission scanning transmission electron microscope (FE-STEM) techniques once thinning is complete. Multiple meteorite studies supported by FIB/FE-STEM are currently underway at NASA-JSC, including coordinated analysis of refractory phase assemblages in CAIs and fine-grained matrices in carbonaceous chondrites. FIB sectioning of CAIs has uncovered epitaxial and other overgrowth relations between corundum-hibonite-spinel consistent with hibonite preceding corundum and/or spinel in non-equilibrium condensation sequences at combinations of higher gas pressures, dust-gas enrichments or significant nebular transport. For all of these cases, the ability of FIB to allow for coordination with spatially-associated isotopic data by SIMS provides immense value for constraining the formation scenarios of the particular CAI assemblage. For carbonaceous chondrites matrix material, FIB has allowed us to obtain intact continuous sections of the immediate outer surface of Murchison (CM2) after it has been experimentally ion processed to simulate solar wind space weathering. The surface amorphization and loss of OH produced by the irradiation provides important clues regarding space weathering on primitive asteroids such as the OSIRIS-Rex target 101955 Bennu.

Christoffersen, Roy↗

On FIRE mode in KSTAR

We report on the status of Fast Ion Regulated Enhancement (FIRE) mode experiments in the Korea Superconducting Tokamak Advanced Research. This regime is being developed for high-performance, steady-state operation which features a stationary ion internal transport barrier, enabling a central ion temperature approaching 10 keV to be sustained for up to 50 s, without the need for delicate profile control and with no significant impurity accumulation. As its key novelty lies in the significant contribution of fast ions that stabilize core turbulence, the regime has been named FIRE mode. To achieve this regime, neutral beam injection is applied at moderate power levels near the L–H power threshold, while maintaining low plasma density to avoid the L–H transition. The scenario is typically established in diverted magnetic configurations. The core features of FIRE mode were investigated through power balance analysis and fluctuation measurements, revealing a clear transport bifurcation in the ion channel. At the plasma edge, FIRE mode occasionally exhibits I-mode characteristics, particularly in unfavorable magnetic null configurations with q 95 ∼ 4, including the presence of weakly coherent modes. In terms of MHD activity, sawtooth oscillations are observed but appear to be stabilized during the high-performance phase. Fast ion-driven Alfvénic eigenmodes (AEs), indicated by strong frequency chirping near 200 kHz, are also observed. Additionally, lower-frequency MHD activities, distinct from the fast ion-driven AEs, are present and have some influence on plasma performance. The enhancement of core confinement is primarily attributed to fast ion effects, which were evaluated with respect to dilution, alpha stabilization, and resonant interactions with turbulence using gyrokinetic analyses. Among these, the dilution effect was found to be the most dominant. The characteristics of FIRE mode were compared with those of other hot ion plasma scenarios, such as supershot and hot ion mode. While they share many similarities, FIRE mode is distinguished by the accessibility to conditions with T i ≈ T e , presence of I-mode edge features, and its long-duration sustainment. Predictive simulations of FIRE mode were performed using integrated transport modeling with TRIASSIC, employing the TGLF anomalous transport model. These simulations confirmed the critical role of fast ions in achieving this regime. The future prospect of FIRE mode for application in fusion reactors is discussed, with an emphasis on possibly extending the regime to higher density operation.

FIRE mode↗

The influence of electrochemical cycling protocols on capacity loss in nickel-rich lithium-ion batteries

The transition towards electric vehicles and more sustainable transportation is dependent on lithium-ion battery (LIB) performance. Ni-rich layered transition metal oxides, such as NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 ), are promising cathode candidates for LIBs due to their higher specific capacity and lower cost compared with lower Ni content materials. However, complex degradation mechanisms inhibit their use. In this work, tailored aging protocols are employed to decouple the effect of electrochemical stimuli on the degradation mechanisms in graphite/NMC811 full cells. Using these protocols, impedance measurements, and differential voltage analysis, the primary drivers for capacity fade and impedance rise are shown to be large state of charge changes combined with high upper cut-off voltage. Focused ion beam-scanning electron microscopy highlights that extensive microscale NMC particle cracking, caused by electrode manufacturing and calendering, is present prior to aging and not immediately detrimental to the gravimetric capacity and impedance. Scanning transmission electron microscopy electron energy loss spectroscopy reveals a correlation between impedance rise and the level of transition metal reduction at the surfaces of aged NMC811. The present study provides insight into the leading causes for LIB performance fading, and highlights the defining role played by the evolving properties of the cathode particle surface layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing Antifouling and Antimicrobial Interfaces: Structural Characterization using CryoEM, Automated Microscopy, and AI Image Segmentation

The design of functionalized surfaces for interactions with biological systems is critical across sectors such as healthcare, energy, and agriculture. Tailoring materials for specific applications, such as antifouling and antimicrobial surfaces, demands a comprehensive understanding of topology and chemistry across multiple length and time scales on both biological and materials systems. This work presents the development and characterization of nanostructured surfaces with controlled topographies and chemistries that enhance bacterial membrane disruption, reduce biofilm formation, and improve antimicrobial and antifouling capabilities. Two specific use cases will be presented - the use of cellulose nanocrystals (CNCs) for bacterial growth inhibition and the development of antifouling surfaces to prevent protein and bacterial adsorption [1-4]. By leveraging large language models (LLMs) for image segmentation and training [5], we enable automated analysis of terabyte-scale cryogenic electron microscopy (cryoEM) datasets. This analysis provides statistical insights into the biotic/abiotic interface and facilitates automated electron microscopy experiments to mitigate time and dose. The integration of cryogenic electron tomography (cryoET) and cryogenic focused ion beam (cryoFIB) milling enables high-resolution, near-native-state imaging and 3D reconstructions of bio/material interfaces [6]. Orthogonal characterization techniques and computational modeling further enhances our understanding, offering a robust platform for the design and optimization of next-generation functional surfaces [7].

Williams, Alexis [ORNL] (ORCID:0000000252835822)↗

Study of Particle Loss in Synchrotron Phase Space Injection for ESR Using Weak-Strong Beam-Beam Simulation with Nonlinear Lattice

In this report, we use tracking simulations to investigate synchrotron phase space injection for electron accumulation in the electron storage ring of the Electron Ion Collider. Our simulation model accounts for both beam-beam interactions and lattice nonlinearities. Specifically, we examine how particle loss is influenced by various parameters. Additionally, we conduct a theoretical analysis and derive an analytical formula for the rapid evaluation of particle loss. Our results demon strate the feasibility of synchrotron phase-space injection for the electron storage ring and provide insights to guide parameter selection for the design of the injection line.

43 PARTICLE ACCELERATORS↗