Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Designing an Intrusion Detection for an Adjustable Speed Drive System Controlling a Critical Process

In this article, we address the cyber-security problem of industrial control systems (ICSs) when their sensor measurements may be compromised due to an attacker who has intercepted those measurements via a network. We introduce a general-purpose method “Dynamic Watermarking (DW)” to detect potential cyber-intrusions on speed sensor measurements within industrial control systems, which deploy an adjustable speed drive (ASD) to control a critical process. The DW method is injecting a random private low-amplitude signal with a zero mean Gaussian distribution, “watermark”, into one of the input phase voltages powering the ASD system. The watermark signal propagates through the system including pulse width modulation (PWM) power conversion stage and motor, then ultimately appears in the speed sensor measurements. By deploying two statistical DW tests with two proper thresholds, the system can detect potential cyber-intrusions or unobservable cyber-attacks such as replay attacks and false data injection attacks (FDIA). The DW method tested on a laboratory-scale ASD system experimentally to protect the system against cyber-intrusions. This system, powered by a commercial PWM drive operating at 208 V, 3-phase, and 3.7 kW, served as our experimental platform.

42 ENGINEERING↗

Toward Emittance Measurements at 11.7 GHz Short-Pulse High-Gradient RF Gun

A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.

43 PARTICLE ACCELERATORS↗

Wellbore injectivity response to step-rate CO 2 injection: Coupled thermo-poro-elastic analysis in a vertically heterogeneous formation

Safe and permanent carbon geological storages require an elaborate analysis of geomechanical stability. Subsurface injection of CO 2 changes the local temperature and pore pressure and, further, alters the stress due to thermo-poro-elastic responses. A permanent CO 2 storage testing was conducted in the water leg of Cranfield reservoir in Mississippi, USA, where hosted CO 2 enhanced-oil recovery activities. During CO 2 injection, the injection rate was ramped up twice but the bottom-hole pressure did not increase with the imposed injection rates as expected. This unexpected field observation suggests the possibility of an open-mode fracture development at the injector. However, the injector response and potential fracture development have not been rigorously interpreted with detailed near-wellbore temperature and pore pressure change upon the CO 2 injection. In this study, we performed history matching of CO 2 injection using coupled thermo-poro-elastic reservoir simulation to examine the possibility of fracturing. We built a reservoir model including vertical heterogeneity in both petrophysical and geomechanical properties estimated from well-logging analysis and laboratory experiments. The simulation results show that CO 2 injection changes stresses and support the hypothesis of development of an open-mode fracture at the injector during the Cranfield test. The near-injector region exhibits a large temperature reduction up to 55 °C with ensuing effective horizontal stress reduction up to 9.1 MPa. However, a caprock integrity issue is unlikely because of the horizontal stress contrast within layers and low hydraulic communication with the injection zone. This work indicates that the injectant temperature should be considered in the design of high-rate CO 2 injector.

58 GEOSCIENCES↗

History Matching and Performance Prediction of a Polymer Flood Pilot in Heavy Oil Reservoir on Alaska North Slope

The first-ever polymer flood pilot to enhance heavy oil recovery on Alaska North Slope (ANS) is ongoing. After more than 2.5 years of polymer injection, significant benefit has been observed from the decrease in water cut from 65% to less than 15% in the project producers. The primary objective of this study is to develop a robust history-matched reservoir simulation model capable of predicting future polymer flood performance. In this work, the reservoir simulation model has been developed based on the geological model and available reservoir and fluid data. In particular, four high transmissibility strips were introduced to connect the injector-producer well pairs, simulating short-circuiting flow behavior that can be explained by viscous fingering and reproducing the water cut history. The strip transmissibilities were manually tuned to improve the history matching results during the waterflooding and polymer flooding periods, respectively. It has been found that higher strip transmissibilities match the sharp water cut increase very well in the waterflooding period. Then the strip transmissibilities need to be reduced with time to match the significant water cut reduction. The viscous fingering effect in the reservoir during waterflooding and the restoration of injection conformance during polymer flooding have been effectively represented. Based on the validated simulation model, numerical simulation tests have been conducted to investigate the oil recovery performance under different development strategies, with consideration for sensitivity to polymer parameter uncertainties. The oil recovery factor with polymer flooding can reach about 39% in 30 years, twice as much as forecasted with continued waterflooding. Besides, the updated reservoir model has been successfully employed to forecast polymer utilization, a valuable parameter to evaluate the pilot test’s economic efficiency. All the investigated development strategies indicate polymer utilization lower than 3.5 lbs/bbl in 30 years, which is economically attractive.

Wang, Xindan↗

CO 2 -Soluble Nonionic Surfactants for Enhanced CO 2 Storage via In Situ Foam Generation

Geologic carbon storage (GCS) is a rapidly evolving technology with the potential to reduce the environmental impact of fos-sil fuels. Saline aquifers, which comprise a sandstone matrix with brine in the pores, make up much of the pore space availa-ble for CO 2 storage in the United States. When CO 2 is injected in saline aquifers, however, capillary fingering occurs and only a small percentage of the pore space is filled with CO 2 . This is due to the low viscosity of CO 2 , which is roughly ten times less viscous than brine. To address this problem, we tested the ability of inexpensive, commercially available nonionic surfactants to be dissolved in the injected CO 2 and increase the apparent viscosity of CO 2 by generating CO 2 -in-water foams in situ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coreflood Tests to Evaluate Enhanced Oil Recovery Potential of Wettability-Altering Surfactants for Oil-Wet Heterogeneous Carbonate Reservoirs

Summary Oil-wetness and heterogeneity are two main factors that result in low oil recovery (OR) by waterflood in carbonate reservoirs. The injected water is likely to flow through high-permeability regions and bypass the oil in the low-permeability matrix. In this study, systematic coreflood tests were carried out in both “homogeneous” cores and “heterogeneous” cores with a wettability-altering surfactant. The homogeneous coreflood tests were conducted to evaluate surfactant retention, as well as to compare tertiary surfactant flooding with secondary surfactant flooding. The heterogeneous coreflood test was proposed to model bypassing in low-permeability matrix during waterfloods, and dynamic imbibition of surfactant into the low-permeability matrix. Surfactant retention results suggest that retention increases as initial oil saturation decreases. The retention of selected surfactant in the target reservoir cores was measured to be within a range of 0.07–0.12 mg/g-rock, which is economically acceptable. The results of homogeneous coreflood tests showed that both secondary waterflood and secondary surfactant flood can achieve high OR (>50%) from relatively homogeneous oil-wet cores. A shut-in phase after the surfactant injection resulted in a surge in oil production, which suggests that enough time should be given for wettability alteration by surfactants. The results of heterogeneous coreflood tests showed that more oil is bypassed in the tighter matrix by waterflood if the permeability is higher in the flooded layer and this bypassed oil is the target for the wettability-altering surfactant floods. Slow wettability-altering surfactant injection leads to imbibition into bypassed regions. When the oil-wet carbonate reservoirs have large unswept regions after waterflood, wettability-altering surfactants can significantly improve OR if enough time is given for imbibition.

Engineering↗

Uncertainty Quantification in CO2 Trapping Mechanisms: A Case Study of PUNQ-S3 Reservoir Model Using Representative Geological Realizations and Unsupervised Machine Learning

Evaluating uncertainty in CO2 injection projections often requires numerous high-resolution geological realizations (GRs) which, although effective, are computationally demanding. This study proposes the use of representative geological realizations (RGRs) as an efficient approach to capture the uncertainty range of the full set while reducing computational costs. A predetermined number of RGRs is selected using an integrated unsupervised machine learning (UML) framework, which includes Euclidean distance measurement, multidimensional scaling (MDS), and a deterministic K-means (DK-means) clustering algorithm. In the context of the intricate 3D aquifer CO2 storage model, PUNQ-S3, these algorithms are utilized. The UML methodology selects five RGRs from a pool of 25 possibilities (20% of the total), taking into account the reservoir quality index (RQI) as a static parameter of the reservoir. To determine the credibility of these RGRs, their simulation results are scrutinized through the application of the Kolmogorov–Smirnov (KS) test, which analyzes the distribution of the output. In this assessment, 40 CO2 injection wells cover the entire reservoir alongside the full set. The end-point simulation results indicate that the CO2 structural, residual, and solubility trapping within the RGRs and full set follow the same distribution. Simulating five RGRs alongside the full set of 25 GRs over 200 years, involving 10 years of CO2 injection, reveals consistently similar trapping distribution patterns, with an average value of Dmax of 0.21 remaining lower than Dcritical (0.66). Using this methodology, computational expenses related to scenario testing and development planning for CO2 storage reservoirs in the presence of geological uncertainties can be substantially reduced.

Mahjour, Seyed Kourosh↗

Utah FORGE: Temperature-Dependent Fracture Seismicity from Fluid Injection Experiments

This dataset contains experimental data from fluid injection experiments conducted to investigate the influence of temperature on fracture seismicity. The experiments were performed on granite samples from Utah FORGE. The samples were prepared with a 30-degree inclined fracture and subjected to controlled stress and temperature conditions. Data were collected under three distinct temperature settings: 24 C, 78 C, and 137 C. During the experiments, a constant confining pressure of 10 MPa and a constant shear stress at 80% of the shear strength of the sample were maintained. Pore pressure was incrementally increased at a rate of 300 kPa every three minutes to simulate fluid injection. Temperature was raised rapidly and then stabilized for the duration of each test. The dataset includes shear stress and displacement measurements under each temperature condition, along with supplementary figures illustrating the experimental setup and time-series plots of pressures and temperature.

15 GEOTHERMAL ENERGY↗

Accelerated version of NUBEAM capabilities in DIII-D using neural networks

A neural network model of the effects of neutral beam injection on DIII-D has been developed. The training and testing data used by the model have been generated by the NUBEAM module of TRANSP for experimental discharges from the 2018 DIII-D campaign. Using a principle component analysis to reduce the dimensionality of profile data, the model has been shown to reproduce the results of the Monte Carlo code NUBEAM with a high level of accuracy and an execution time orders of magnitude faster than the execution time of NUBEAM. Furthermore, this makes the neural network model uniquely suited to applications in model-based scenario planning (off-line) and active control (on-line), where a large number of simulation runs are required by the associated optimization tasks that need to be performed before and during the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Microwave Plasma Flash Pyrolysis for Coal-to-Product Applications

Since 2010, the US coal industry has experienced a precipitous decline, with coal production volumes dropping by as much as 35% according to EIA. This decline is hardly surprising given that 90% of domestic coal use is allocated to electricity production: While coal generation supplied about 45% of the nation's power in 2010, its share is projected to fall to only 22% in 2020. Fortunately, alternative uses for coal as a feedstock rather than as energy source are available. Coal tar is an established feedstock for chemicals and high-value carbon products including carbon fiber and battery-grade graphites. At present, growth of these uses is constrained by the low availability, purity, and yields of currently available coal liquids, and high energy- and CO2-intensity of current methods of production (i.e. coking). Previously reported work conducted in a partnership with Pacific Northwest National Laboratory demonstrated technical and economic viability of flash pyrolysis of coal in a microwave plasma environment at bench scales targeting production of fuel feedstocks (synthetic oil). H Quest’s work since then indicated promise of microwave-derived coal liquids to be uniquely suited for the lower-cost production of carbon materials, including synthetic graphite, carbon fiber, and composites. Low bulk process temperatures, subsecond residence times, and ambient pressure operation enable small-scale deployment, reduce capital and operating costs, and suppress formation of impurities, including QI material, typical in conventional coal tars. With no inherent production of CO2 or water consumption, microwave plasma flash pyrolysis presents a viable route to the sustainable production of both platform chemicals and carbon-based materials. Most recently, H Quest developed a novel, ruggedized microwave plasma reactor, which departs from the proof-of-concept approach and addresses the problems typically encountered in scaling laboratory microwave plasma apparata (e.g. eliminating fragile quartz enclosures prone to coking and fouling). This reactor has been integrated with a 15kW microwave power supply, a pulverized coal injection system, and a product recovery system. A series of screening tests across a range of coals (including hv-, lv-bituminous and subbituminous PRB), entrainment gas flows and compositions and microwave energy inputs are performed to evaluate conversion rates within the novel, scaled-up system, confirm yields of liquid products, and to perform compositional (GC/MS and elemental) analyses of the products. Results of these tests will be presented and discussed.

Skoptsov, George↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

Field Validation of MVA Technology for Offshore CCS: Novel Ultra-High-Resolution 3D Marine Seismic Technology (P-Cable) (Final Report)

The objectives of the proposed study were to deploy and validate a specific monitoring technology, high-resolution 3D marine seismic (HR3D), appropriate for large-demonstration and commercial-scale offshore CCS sites. The project accomplished successful acquisition two HR3D seismic surveys. The first HR3D dataset was over the offshore injection site of the Tomakomai, Japan integrated pilot CCS project, which at the time of survey acquisition was actively injecting CO 2 . The first survey also represented a successful international collaboration between the DOE NETL program and Japan’s national CCS program and was the first successful acquisition and use of HR3D over an active CO 2 injection site (Meckel, Feng et al. 2019). The Tomakomai HR3D survey successfully tested a novel 4-streamer HR3D system array in which, for the first time, no cross-cable (aka “P-Cable”) was utilized and only four GeoEel streamers were used instead of the standard 12-streamer configuration. Consequently, this was not, strictly speaking, a deployment of the “P-Cable” system of (Planke and Berndt 2004) but rather a modified version, thereof, and it is the first known demonstration of the modified system configuration. One very positive outcome from the Japanese collaboration earlier in the project was the ability to learn from the Japanese how they used tail buoys with GPS to determine the position of the seismic source and receivers in time and space. Based on that experience, GCCC designed and built six GPS receivers that could be used to position the streamer receivers and the seismic source via tail buoys. A fundamental advance that was made on the original design, was the ability to directly power the tail buoy GPS units and transfer data through the streamers (i.e., vs. the batteries used at Tomakomai). The bulkiness of the GPS batteries caused drag and episodic surging of the buoys, which affected data quality by lifting up the tail end of the streamers so the receivers were not at the same depth. The units were tested onshore for accuracy and functionality, and the design was subsequently and successfully tested in marine acquisition mode during the SLP survey acquisition. The marine acquisition test and survey satisfied Subtasks 2.2.2, Novel Positioning Technology Selection and Subtask 2.2.3, Novel Positioning Technology Deployment. Results of the novel positioning technology selection (Subtask 2.2.2) were considered successful and will be incorporated in future HR3D seismic acquisition projects to reduce costs, improve deployment safety at sea, and integrate both seismic and data recording via a single data transfer through the streamers to the recording system. The project also established a permitting process through NETL NEPA compliance, which included an Environmental Assessment in a marine setting and is required for conducting these types of surveys using Federal funding. The permitting process charted a “boilerplate,” which can allow future surveys related to other funded projects to move forward more expeditiously. Future improvements that could be considered are more robust seals on the GPS module and stronger materials (especially joints) on tail buoy fabrication. These would increase fixed costs, but would be advisable and probably more economic long-term if multiple HR3D surveys are planned. Project Accomplishments include: • Pre-survey Sensitivity Study • Marine geochemistry methods and data analysis • Successful HR3D seismic dataset acquired @ Tomakomai active CO 2 injection marine site • Developed advanced seismic processing techniques • No NRMS anomalies detected in overburden; Demonstration of containment • Repeatability study • Second survey collected @ San Luis Pass, TX • 4D application using positioning techniques developed in the project for monitoring were successful

3D seismic GPS positioning↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Selecting representative geological realizations to model subsurface CO 2 storage under uncertainty

Carbon capture and storage (CCS) is one of the quickest and most effective solutions for reducing carbon emissions. The majority of subsurface storage occurs in saline aquifers, for which geological information is lacking which in turn results in geological uncertainty. To evaluate uncertainty in CO 2 injection projections, the use of multiple geological realizations (GRs) has been practiced very commonly. In this approach, hundreds or thousands of high-resolution GRs is used that quickly becomes computationally expensive. This issue can be addressed with representative geological realizations (RGRs) that preserve the uncertainty domain of the ensemble GRs. Here, in this study, we propose the use of unsupervised machine learning (UML) frameworks, including dissimilarity measurement, dimensionality reduction, clustering and sampling algorithms ta select a predetermined number of RGRs. We compare the simulation outputs of the RGR sets and the ensemble using the Kolmogorov–Smirnov (KS) test to select the best UML. The UML frameworks and their associated selection processes are evaluated using a saline aquifer with a single CO 2 injection well and 200 GRs with varying uncertain petrophysical characteristics. The best UML framework is selected to use only 5% of the GRs while maintaining the uncertainty domain of the ensemble GRs. In addition, the best UML framework is tested using a saline aquifer with three CO 2 injection wells and varied GRs. The results show that our proposed UML framework can be used to choose RGRs, capturing the whole uncertainty domain. Our approach leads to a significant reduction in the computational cost associated with scenario testing, decision-making, and development planning for CO 2 storage sites under geological uncertainty.

58 GEOSCIENCES↗

Geomechanical Characterization of the Mount Simon Sandstone and Eau Claire Formation of Northern Illinois Basin

The purpose of this paper is to analyze publicly available geomechanical data from two carbon storage sites in the Illinois Basin: the Illinois Basin-Decatur Project (IBDP) in Macon County, IL and the FutureGen2.0 project in Morgan County, IL, cancelled before injection began. This study estimates the magnitudes and directions of the least compressive principal stress gradient using hydraulic fracture-based stress measurement tests, borehole breakouts, and sonic logs in the Eau Claire Formation (primary confining zone) and the Mount Simon Sandstone (targeted reservoir). The range of stresses expected in the underlying Precambrian basement is also investigated. The evaluation of the state of stress is carried out in a probabilistic manner using the State of Stress Analysis Tool (SOSAT) developed under the National Risk Assessment Partnership (NRAP) program. Finally, the paper also provides a discussion on distinctions between fracture initiation pressure, propagation pressure, and fracture closure pressure, given that hydraulic fracture testing results show a significant difference between these three values. The discussion also addresses why the fracture closure pressure should be preferred in injection pressure determinations, a critical point in geological carbon storage projects.

de Toledo Camargo, Julia↗