Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “in situ testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

High-strength, lightweight nano-architected silica

Continuous nanolattices are an emerging class of mechanical metamaterials that are highly attractive due to their superior strength-to-weight ratios, which originate from their spatial architectures and nanoscale-sized elements possessing near-theoretical strength. Rational design of frameworks remains challenging below 50 nm because of limited methods to arrange small elements into complex architectures. Here, we fabricate silica frameworks with ~4- to 20-nm-thick elements using self-assembly and silica templating of DNA origami nanolattices and perform in situ micro-compression testing to examine the mechanical properties. We observe strong effects of lattice dimensions on yield strength (σ $\mathcal{y}$ ) and failure mode. Silica nanolattices are found to exhibit yield strengths higher than those of any known engineering materials with similar mass density. The robust coordination of the nanothin and strong silica elements leads to the combination of lightweight and high-strength framework materials offering an effective strategy for the fabrication of nanoarchitected materials with superior mechanical properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Atomistic measurement and modeling of intrinsic fracture toughness of two-dimensional materials

Quantifying the intrinsic mechanical properties of two-dimensional (2D) materials is essential to predict the long-term reliability of materials and systems in emerging applications ranging from energy to health to next-generation sensors and electronics. Currently, measurements of fracture toughness and identification of associated atomistic mechanisms remain challenging. Herein, we report an integrated experimental–computational framework in which in-situ high-resolution transmission electron microscopy (HRTEM) measurements of the intrinsic fracture energy of monolayer MoS 2 and MoSe 2 are in good agreement with atomistic model predictions based on an accurately parameterized interatomic potential. Changes in crystalline structures at the crack tip and crack edges, as observed in in-situ HRTEM crack extension tests, are properly predicted. Such a good agreement is the result of including large deformation pathways and phase transitions in the parameterization of the inter-atomic potential. The established framework emerges as a robust approach to determine the predictive capabilities of molecular dynamics models employed in the screening of 2D materials, in the spirit of the materials genome initiative. Moreover, it enables device-level predictions with superior accuracy (e.g., fatigue lifetime predictions of electro- and opto-electronic nanodevices).

Zhang, Xu↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Leading Edge Erosion Classification System

The leading edge erosion of wind turbine blades is a common issue that can have a range of implications for the operation and maintenance of the turbine. A variety of methods have attempted to determine the severity of erosion damage, applied in different academic, testing and in-situ settings. This paper describes the current state of the art in categorization, and the individual drivers in assessment. From this foundation, the IEA Wind Task 46 WP3 group collated key considerations from the process of categorizing erosion damage and a proposed erosion classification system was put forward. Trial assessments were performed using the initial system, which led to adjustments to the original proposition. The refined system defines discrete severity levels that concern the wind turbine blade: (1) Visual Condition (concerning blades with/without leading edge protection); (2) Mass Loss; (3) Aerodynamic Performance; and (4) Structural Integrity. The classification system presented is not intended to be a fixed entity. The Task 46 group has already identified specific challenges and opportunities that are applicable to individual use and the overall wind energy industry. The intention is for the system to evolve as improvements are identified, technology improves, and work progresses through other Task 46 activities. Several considerations and recommendations are discussed that could be applicable for future implementation of the system.

17 WIND ENERGY↗

Advanced Characterization Capabilities for Nuclear Materials via Nuclear Science User Facilities (NSUF)

Advanced post-irradiation examination (PIE) techniques are required to design new or improved nuclear materials, characterize, and understand in-core behavior of fuel and materials, and support the qualification of new reactor materials. The Nuclear Science User Facilities (NSUF) is the U.S. Department of Energy Office of Nuclear Energy's only designated nuclear science user facility. NSUF provides researchers access to PIE capabilities at Idaho National Laboratory and at a diverse mix of university, national laboratory and industrial partner institutions. The PIE capabilities include novel destructive and non-destructive techniques for radiation damage characterization, such as advanced diffraction techniques (X-ray, electron, or neutron) coupled to extreme environments; in-situ observation of microstructural evolution under irradiation; in-situ irradiation to monitor corrosive attack in coolant environments; in-situ irradiation and mechanical testing; and test methods for synergistic effects of superimposed extreme environments (temperature, irradiation, stress, corrosion) on materials behaviors. This talk will provide an overview of NSUF PIE capabilities.

36 MATERIALS SCIENCE↗

Micro-Tensile Properties of Irradiated AGR-2 TRISO Fuel Pyrolytic Carbon (PyC) and Silicon Carbide (SiC) Coatings

Tristructural isotropic (TRISO) coated nuclear fuel particles are emerging as a versatile option for new reactor designs, with the silicon carbide (SiC) layer crucial for retaining fission products. However, the mechanical properties of TRISO coating layers, particularly after irradiation, are not fully understood due to their small size and high radioactivity. Recent in situ micro-tensile testing of various TRISO layers aims to better understand the SiC layer's failure mechanisms, advancing TRISO fuel qualification. These micro-tensile results will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

A novel in-situ Raman spectroscopic cell for aqueous geochemistry at the solid–liquid interface

In-situ Raman spectroscopy has the potential to be a powerful technique for monitoring geochemical reactions at a solid–liquid interface in real time. In this article, we present the development and testing of an in-situ Raman spectroscopic cell, which can be used for reaction systems at moderate temperatures and pressure [<1000 psi (6.89 MPa), <100 °C, relevant to subsurface geologic systems] and can hold samples large enough for chemical mapping of heterogeneous rock surfaces. The system is validated by measuring the temperature-dependent conversion of gypsum to calcite over time. Near total conversion of gypsum to calcite on the mineral surface took 29 hours at room temperature and 150 minutes at 100 °C, corresponding to an 11.6-fold increase in the conversion rate. Further, we anticipate that this cell can be an important tool in quantifying the rates of carbon mineralization relevant to geologic carbon sequestration, particularly for the elevated rates recently observed in mafic/ultramafic rocks.

47 OTHER INSTRUMENTATION↗

In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

25 ENERGY STORAGE↗

Real-Time Observation of Nanoscale Kink Band Mediated Plasticity in Ion-Irradiated Graphite: An In Situ TEM Study

Graphite IG-110 is a synthetic polycrystalline material used as a neutron moderator in reactors. Graphite is inherently brittle and is known to exhibit a further increase in brittleness due to radiation damage at room temperature. To understand the irradiation effects on pre-existing defects and their overall influence on external load, micropillar compression tests were performed using in situ nanoindentation in the Transmission Electron Microscopy (TEM) for both pristine and ion-irradiated samples. While pristine specimens showed brittle and subsequent catastrophic failure, the 2.8 MeV Au2+ ion (fluence of 4.378 × 1014 cm−2) irradiated specimens sustained extensive plasticity at room temperature without failure. In situ TEM characterization showed nucleation of nanoscale kink band structures at numerous sites, where the localized plasticity appeared to close the defects and cracks while allowing large average strain. We propose that compressive mechanical stress due to dimensional change during ion irradiation transforms buckled basal layers in graphite into kink bands. The externally applied load during the micropillar tests proliferates the nucleation and motion of kink bands to accommodate the large plastic strain. The inherent non-uniformity of graphite microstructure promotes such strain localization, making kink bands the predominant mechanism behind unprecedented toughness in an otherwise brittle material.

36 MATERIALS SCIENCE↗

Tensile behavior and microstructural evolution of a Fe-25Ni-20Cr austenitic stainless steel (alloy 709) from room to elevated temperatures through in-situ synchrotron X-ray diffraction characterization and transmission electron microscopy

Uniaxial tensile tests were done on Fe-25Ni-20Cr Austenitic Stainless Steel (Alloy 709) along with in-situ synchrotron measurement at different temperatures (25 degrees C, 500 degrees C, 700 degrees C and 900 degrees C). The X-Ray diffraction data was collected in-situ in order to follow the phases present as well as to derive the dislocation density as a function of strain through peak broadening analysis based on the modified Williamson-Hall method and see how trends are affected as a function of temperature. The XRD data were complemented by TEM and STEM-EDX characterization done on the post-experiment samples to observe the deformed microstructures. Finally, the paper presents a depiction of the tensile behavior of this advanced steel by interpreting the stress-strain curves and the effect of temperature through the information gained by in-situ XRD and TEM observations as well as fractography done ex-situ on the samples tested to rupture.

36 MATERIALS SCIENCE↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Understanding Li-Ion Cell Internal Short Circuit and Thermal Runaway through Small, Slow and In Situ Sensing Nail Penetration

Here we report a small, slow and in situ sensing (3S) nail penetration test method to understand Li-ion cell internal short circuit (ISC) and thermal runaway. The method not only keeps conventional nail penetration's advantage of simple implementation, but also enhances its relevance to field failures and enables detailed in situ diagnosis. It was applied to 3-Ah pouch cells and revealed insights that could not be captured by conventional methods. Most interestingly, multiple in situ temperature peaks were observed during a period of over 100 s before thermal runaway. These initial peaks exceeded safety limit but the temperature rapidly decreased after each peak instead of causing immediate thermal runaway. Further investigation suggested that the initial temperature peaks occurred when nail tip reached aluminum foil current collector to form a low resistance ISC between anode and aluminum foil. The rapid temperature decrease after each peak can be attributed to sudden drop of ISC current, which can be further attributed to rupture of aluminum foil and increase of contact resistance. The findings show that 3S nail penetration test can separate processes of ISC from thermal runaway and provide details of ISC at the level of individual electrode and current collector.

25 ENERGY STORAGE↗

Acceptance criteria for in situ surveillance of MSR materials based on thermally-loaded mechanical test articles

This report describes practices and acceptance test procedures for designing, running, and maintaining a material surveillance program in a future operating molten salt reactor. The programs described here rely on test data from passively actuated mechanical test articles inserted into critical regions of the reactor and periodically removed for out-of-reactor testing. The report defines definite acceptance procedures, based on the results of these tests, to determine whether a component can continue to operate accounting for the accumulation of environmentally-assisted mechanical damage in the component materials to date, and extrapolated out through the next inspection period. Additionally, the report describes work on a software tool implementing many of the surveillance methods and procedures described here and progress on simplified methods for inferring damage accumulation in the test articles, based on out-of-reactor thermal cycling, that do not rely on sophisticated numerical analysis.

36 MATERIALS SCIENCE↗

In Situ Measurement of Stress Corrosion Crack Tip Properties During Environmentally Induced Cracking in Stainless Steel 304L

The influence of the external cathodic area, stress intensity, and electrochemical polarization level on the resultant crack growth rate and crack tip pH and potential was studied for stainless steel 304L in a sodium chloride environment. Before testing, the validity of in situ crack tip property measurements using microprobes and drilled holes was supported through modeling efforts and confirmed with experimental observations. Here, it was found that increasing the R-ratio during corrosion fatigue increased the crack growth rate and decreased the measured crack tip pH of the 304L sample. Decreasing the electrochemical potential (i.e., cathodic polarization) of the bulk sample increased the crack tip pH and stopped measured crack extension under constant K conditions. Conversely, increasing the potential of the bulk sample decreased the crack tip pH and induced cracking under constant K conditions. Decreasing the cathodic area external to the crack increased the measured pH at the crack tip and decreased the crack growth rate under fatigue conditions. For the given configuration, environment, and alloy studied, fatigue crack growth is not sustained by cathodic reactions solely occurring in the crack wake and notch. These results have implications for the ability to predict atmospheric crack growth rates from laboratory, full immersion experiments.

corrosion fatigue↗

Design of RUSL Irradiation Experiment with Free Standing Sample

During FY19, the MIMIC-RUSL TREAT test successfully measured the shift in resonance of a cantilever beam as it underwent a grain restructuring event in the TREAT reactor core. FY20 efforts focused on a new capsule design which would replace the cantilever beam with a free-free beam. The free-free beam configuration eliminates the cantilever boundary condition and enables internal friction measurements. A test capsule was designed which supported the sample beam at the nodal points of the first flexural vibration mode. Initial tests detected the resonance peak but the signal to noise level was not high enough for in-situ measurements. Several detection probes were tested and a significant increase in the signal to noise was achieved. Although adequate signals and clean resonance peaks were measured when the beam was centered, the beam did not self-center when displaced resulting in distorted and inconsistent resonance peaks. It was concluded that the free-free beam approach is likely not suited for in-situ measurements. Measurement of ZGV plate waves is another option for in-situ microstructure monitoring and should be considered for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Non-Invasive Approach for Elucidating the Spatial Distribution of in-situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (Task 4 (Field Testing) Report)

"This document presents a summary of TASK 4 (Field Testing) of the project entitled “A Non-Invasive Approach for Elucidating the Spatial Distribution of in-situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (FE0031686)”. This three-year project is part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Carbon Storage program to research and address gaps that affect the economics of commercial CCS projects. One of these key gaps is the lack of certainty in predicting the geomechanical impacts of pressure migration due to CO 2 injection into a storage complex. This report documents field testing that was conducted under TASK 4 to obtain input data needed to develop the site-specific geomechanical model in TASK 5 and to verify the model results (i.e. calculated stresses) for this site. The field work entailed collecting geophysical logs and core samples and conducting geomechanical stress tests in the Core Energy LLC State Otsego Lake (SOL 8-15A) well, located in Otsego County, Michigan."

58 GEOSCIENCES↗