Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “implicit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Digital flight control design using implicit model following.

A design procedure for determining the control gains of a discrete-time ('digital') control system is presented. The method is separable into four distinct steps: (1) the definition of closed-loop response criteria, (2) the choice of a discrete-time model which provides the desired response, (3) the determination of control gains which implicitly force the actual system to follow the desired response, and (4) the reduction of the measurement state by the introduction of an 'observer' (a form of integral-differential compensation). It is shown that a single desired response does not completely define the 'ideal' system. The response criterion generally leaves some parameters of the model unspecified, allowing two courses for improving the model: (1) definition of additional response criteria, or (2) redefinition of the discrete-time model for improved implicit model-following with the actual closed-loop system.

Stengel, R. F.↗

Higher order accurate partial implicitization: An unconditionally stable fourth-order-accurate explicit numerical technique

The previously obtained second-order-accurate partial implicitization numerical technique used in the solution of fluid dynamic problems was modified with little complication to achieve fourth-order accuracy. The Von Neumann stability analysis demonstrated the unconditional linear stability of the technique. The order of the truncation error was deduced from the Taylor series expansions of the linearized difference equations and was verified by numerical solutions to Burger's equation. For comparison, results were also obtained for Burger's equation using a second-order-accurate partial-implicitization scheme, as well as the fourth-order scheme of Kreiss.

Graves, R. A., Jr.↗

Comments on the role of diagonal dominance in implicit difference methods

Numerical tests were made for a model of the Navier-Stokes equations using a second-order accurate implicit scheme which guarantees diagonal dominance. The results suggest that the failure of implicit methods using large marching steps may not always be attributed to the lack of diagonal dominance in the coefficient matrix. In some cases the failure may be caused by a nonlinear instability associated with the solution method.

Rudy, D. H.↗

Implicit finite-difference procedures for the computation of vortex wakes

Implicit finite-difference procedures for the primitive form of the incompressible Navier-Stokes and the compressible Euler equations are used to compute vortex wake flows. The partial differential equations in strong conservation-law form are transformed to cluster grid points in regions with large changes in vorticity. In addition to clustering, fourth-order accurate, spatial difference operators are used to help resolve the flow-field gradients. The use of implicit time-differencing permits large time steps to be taken since temporal variations are typically small. Computational efficiency is achieved by approximate factorization. Both two-dimensional and preliminary three-dimensional calculations are described and qualitatively compared with existing experimental data.

Steger, J. L.↗

Conservative implicit schemes for the full potential equation applied to transonic flows

Implicit approximate factorization techniques (AF) were investigated for the solution of matrix equations resulting from finite difference approximations to the full potential equation in conservation form. For transonic flows, an artificial viscosity, required to maintain stability in supersonic regions, was introduced by an upwind bias of the density. Two implicit AF procedures are presented and their convergence performance is compared with that of the standard transonic solution procedure, successive line overrelaxation (SLOR). Subcritical and supercritical test cases are considered. The results indicate that the AF schemes are substantially faster than SLOR.

Holst, T. L.↗

An alternating direction implicit method for the Control Data STAR-100 vector computer

An implementation of the alternating direction implicit (ADI) method for the Control Data STAR-100 computer is presented and analyzed. Two parallel algorithms, both of which are most efficient when used to solve many independent tridiagonal systems of equations, are discussed relative to their usefulness in an ADI implementation on the STAR-100 computer. It is shown that it may be desirable to alternate between the parallel algorithms as the direction of implicitness is alternated in order to eliminate the data rearrangement which would otherwise be required. The applicability of the two parallel tridiagonal solvers to several other numerical algorithms is also discussed.

Lambiotte, J. J., Jr.↗

An implicit-iterative solution of the heat conduction equation with a radiation boundary condition

For the problem of predicting one-dimensional heat transfer between conducting and radiating mediums by an implicit finite difference method, four different formulations were used to approximate the surface radiation boundary condition while retaining an implicit formulation for the interior temperature nodes. These formulations are an explicit boundary condition, a linearized boundary condition, an iterative boundary condition, and a semi-iterative boundary method. The results of these methods in predicting surface temperature on the space shuttle orbiter thermal protection system model under a variety of heating rates were compared. The iterative technique caused the surface temperature to be bounded at each step. While the linearized and explicit methods were generally more efficient, the iterative and semi-iterative techniques provided a realistic surface temperature response without requiring step size control techniques.

Williams, S. D.↗

On implicit finite-difference simulations of three-dimensional flow

An implicit finite-difference procedure for unsteady three-dimensional flow capable of handling arbitrary geometry through the use of general coordinate transformations is described. Viscous effects are optionally incorporated with a 'thin layer' approximation of the Navier-Stokes equations. An implicit approximate factorization technique is employed so that the small grid sizes required for spatial accuracy and viscous resolution do not impose stringent stability limitations. Results obtained from the program include transonic inviscid and laminar-turbulent solutions about simple body configurations. Comparisons with existing theories and experiments are made. Numerical accuracy and the effect of three-dimensional coordinate singularities are also discussed.

Pulliam, T. H.↗

Supersonic flow over ablated nosetips using an unsteady, implicit numerical procedure

The axisymmetric supersonic flow over passive, that is, nonablating, indented nosetips of reentry vehicles is determined using an unsteady implicit numerical algorithm which solves either the inviscid Euler equations or the 'thin-layer' Navier-Stokes equations. A nonorthogonal independent variable transformation is used to map the distorted physical region, containing multiple zones of embedded subsonic flow into a rectangular computational domain at whose boundaries the required permeable or impermeable boundary conditions are simulated. Use of the implicit algorithm results in faster convergence to the steady state because of a larger allowable time step over conventional explicit schemes. The numerical results obtained compare favorably with existing experimental data for very mildly and severely indented blunt nosetips.

Kutler, P.↗

Alternating direction implicit methods for parabolic equations with a mixed derivative

Alternating direction implicit (ADI) schemes for two-dimensional parabolic equations with a mixed derivative are constructed by using the class of all A sub 0-stable linear two-step methods in conjunction with the method of approximation factorization. The mixed derivative is treated with an explicit two-step method which is compatible with an implicit A sub 0-stable method. The parameter space for which the resulting ADI schemes are second order accurate and unconditionally stable is determined. Some numerical examples are given.

Beam, R. M.↗

An implicit factored scheme for the compressible Navier-Stokes equations. II - The numerical ODE connection

An attempt is made to establish a connection between linear multistep methods for applications to ordinary differential equations and their extension (by approximate factorization) to alternating direction implicit methods for partial differential equations. An earlier implicit factored scheme for the compressible Navier-Stokes equations is generalized by innovations that (1) increase the class of temporal difference schemes to include all linear multistep methods, (2) optimize the class of unconditionally stable factored schemes by a new choice of unknown variable, and (3) improve the computational efficiency by the introduction of quasi-one-leg methods.

Beam, R. M.↗

Supersonic flow over three-dimensional ablated nosetips using an unsteady implicit numerical procedure

The three-dimensional supersonic flow over passive, that is, nonablating, indented nosetips of reentry vehicles is determined using an unsteady implicit numerical algorithm which solves either the inviscid Euler equations or the 'thin-layer' Navier-Stokes equations. A nonorthogonal independent variable transformation is used to map the distorted physical domain, containing multiple zones of embedded subsonic flow and separated flow regions into a rectangular computational volume at whose boundaries the required permeable or impermeable boundary conditions are simulated. Use of the implicit algorithm results in faster convergence to the steady state because of a larger allowable time step over conventional explicit schemes. The numerical results obtained compare favorably with existing numerical solutions and experimental data for simple spheres which validates the program. Results are also presented for analytically defined indented bodies for both laminar and turbulent flow conditions that demonstrate the program's capability for computing such flows.

Kutler, P.↗

A fast semi-implicit algorithm for problems of mixed type

Certain physical processes are modeled by partial differential equations which are parabolic over part of the domain and elliptic over the remainder. A family of semi-implicit algorithms which are well suited to initial-boundary value problems of this mixed type is discussed. One important feature of these algorithms is the use of an approximate inverse for the solution of the implicit linear system. A strong error analysis results in an estimate of the total error as a function of approximate inverse error e and time step h.

Frederickson, P. O.↗

On the construction and application of implicit factored schemes for conservation laws

Efficient, noniterative, implicit finite difference algorithms are systematically developed for nonlinear conservation laws including purely hyperbolic systems and mixed hyperbolic parabolic systems. Utilization of a rational fraction or Pade time differencing formulas, yields a direct and natural derivation of an implicit scheme in a delta form. Attention is given to advantages of the delta formation and to various properties of one- and two-dimensional algorithms.

Warming, R. F.↗

Alternating direction implicit methods for parabolic equations with a mixed derivative

Alternating direction implicit (ADI) schemes for two-dimensional parabolic equations with a mixed derivative are constructed by using the class of all A(0)-stable linear two-step methods in conjunction with the method of approximate factorization. The mixed derivative is treated with an explicit two-step method which is compatible with an implicit A(0)-stable method. The parameter space for which the resulting ADI schemes are second-order accurate and unconditionally stable is determined. Some numerical examples are given.

Beam, R. M.↗

Implicit boundary conditions for the solution of the parabolized Navier-Stokes equations for supersonic flows

A fully implicit set of boundary conditions is developed for the solution of the parabolized Navier-Stokes equations for supersonic flow in two dimensions. Shock fitting is employed at the shock and the body has no-slip and specified temperature conditions. A specified heat transfer condition at the wall can be handled in a similar manner. In addition, the shock location is advanced in space in a fully implicit manner by utilizing the Rankine-Hugoniot conditions along with global conservation of mass.

Barnett, M.↗

Implicit calculations of transonic flows using monotone methods

Implicit approximate-factorization algorithms have been developed that use monotone methods for the calculation of steady and unsteady transonic flows governed by the small-disturbance-potential equation. These algorithms use the new Engquist-Osher switch in the type-dependent differencing in place of the standard Murman-Cole switch. The resulting algorithms are more stable; hence, calculations can be done more efficiently. For steady flows, the convergence rate is about 35% faster, and for unsteady flows the allowable time step is about 10 times larger. These improvements are achieved with no increase in computer storage and with only minor modifications in codes that use the Murman-Cole switch. Also an implicit algorithm has been developed for the steady full-potential equation in one-dimension, which uses monotone methods.

Goorjian, P. M.↗