Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

Laser Wakefield Acceleration (LWFA) experiments have been performed at the Jupiter Laser Facility, Lawrence Livermore National Laboratory. In order to unambiguously determine the output electron beam energy and deflection angle at the plasma exit, we have implemented a two-screen electron spectrometer. This system is comprised of a dipole magnet followed by two image plates. By measuring the electron beam deviation from the laser axis on each plate, both the energy and deflection angle at the plasma exit are determined through the relativistic equation of motion.

42 ENGINEERING↗

Laser Wakefield Acceleration at Reduced Density in the Self-Guided Regime

Experiments conducted using a 200TW 60 fs laser have demonstrated up to 720 MeV electrons in the self-guided laser wakefield regime using pure Helium gas jet targets. Charge and energy of the accelerated electrons was measured using an electron spectrometer with a 0.5T magnet and charge callibrated image plates. The self-trapped charge in a helium plasma was shown to fall off with decreasing electron density with a threshold at 2.5 x 10{sup 18} (cm{sup -3}) below which no charge is trapped. Self-guiding however is shown to continue below this density limitation over distances of 14 mm with an exit spot size of 25{micro}m. Simulations show that injection of electrons at these densities can be assisted through ionization induced trapping in a mix of Helium with 3% Oxygen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Review of X-ray Diagnostic Calibrations in the 2 to 100 keV Region Using the High Energy X-ray Calibration Facility (HEX)

The precise and accurate measurement of X-rays in the 2 keV to 100 keV region is crucial to the understanding of HED plasmas and warm dense matter in general. With the emergence of inertially confined plasma facilities as the premier platforms for ICF, laboratory astrophysics, and national security related plasma experiments, the need to calibrate diagnostics in the high energy X-ray regime has grown. At National Security Technologies High Energy X-ray Calibration Facility (HEX) in Livermore, California, X-ray imagers, filter-fluorescer spectrometers, crystal spectrometers, image plates, and nuclear diagnostics are calibrated. The HEX can provide measurements of atomic line radiation, X-ray flux (accuracy within 10%), and X-ray energy (accuracy within 1%). The HEX source is comprised of a commercial 160 kV X-ray tube, a fluorescer wheel, a filter wheel, and a lead encasement. The X-ray tube produces a Tungsten bremsstrahlung spectrum which causes a foil to fluoresce line radiation. To minimize bremsstrahlung in the radiation for calibration we also provide various foils as filters. For experimental purposes, a vacuum box capable of 10{sup -7} Torr, as well as HPGe and CdTe radiation detectors, are provided on an optical table. Most geometries and arrangements can be changed to meet experimental needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fresnel zone plates for Achromatic Imaging Survey of X-ray sources

A telescope with Fresnel Zone Plates has been contemplated to be an excellent imaging mask in X-rays and gamma-rays for quite some time. With a proper choice of zone plate material, spacing and an appropriate readout system it is possible to achieve any theoretical angular resolution. We provide the results of numerical simulations of how a large number of X-ray sources could be imaged at a high resolution. We believe that such an imager would be an excellent tool for a future survey mission for X-ray and gamma-ray sources which we propose.

79 ASTRONOMY AND ASTROPHYSICS↗

The extraction of accurate coordinates of images on photographic plates by means of a scanning type measuring machine

The Moire method experimental stress analysis is similar to a problem encountered in astrometry. It is necessary to extract accurate coordinates from images on photographic plates. The solution to the mutual problem found applicable to the field of experimental stress analysis is presented to outline the measurement problem. A discussion of the photo-reading device developed to make the measurements follows.

Ross, B. E.↗

Scintillator based fiber optic plate for neutron imaging applications and the like

A chalcopyrite, colquiriite, neutron absorber loaded glass, or plastic scintillator based fiber optic plate for use in a neutron imaging system, including: a plurality of optical fiber segments disposed side-by-side adjacent to one another in a parallel array; and a binder material disposed between and coupling the plurality of optical fiber segments together. A diffuse reflective material is optically coupled to the plurality of first ends of the plurality of optical fiber segments. An optical detector device is optically coupled to the plurality of second ends of the plurality of optical fiber segments opposite the diffuse reflective material. Optionally, the fiber optic plate further includes a diffuse reflective material disposed one or more of on an exterior surface of each of the plurality of optical fiber segments and between the plurality of optical fiber segments.

42 ENGINEERING↗

Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

Roth, Don J.↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Plate Scattering Visualization: Images, Near Fields, Currents, and Far Field Patterns

This paper presents a case study of a simple yet robust target for demonstration of the EM visualization process. A five lambda square plate exhibits many scattering mechanisms depending on excitation angle and polarization: specular scattering, leading and trailing edge diffraction, traveling wave, and edge wave scattering. Bistatic k space radiation images, currents maps, and near scattered / total fields are examined for each of these scattering mechanisms.

Shaeffer, John↗

Development of a compact E ? B microchannel plate detector for beam imaging

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Bistatic k Space Images Compared to Experimental Swept Frequency EAR Images

A case study of flat plate scattering images obtained by the analytical bistatic k space and experimental swept frequency ISAR methods is presented. The key advantage of the bistatic k space image is that a single excitation is required, i.e., one frequency I one angle. This means that prediction approaches such as MOM only need to compute one solution at a single frequency. Bistatic image Fourier transform data are obtained by computing the scattered field at various bistatic positions about the body in k space. Experimental image Fourier transform data are obtained from the measured response to a bandwidth of frequencies over a target rotation range.

Shaeffer, John↗