Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “identity elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Self-Stabilizing Synchronization Protocol for Arbitrary Digraphs

This paper presents a self-stabilizing distributed clock synchronization protocol in the absence of faults in the system. It is focused on the distributed clock synchronization of an arbitrary, non-partitioned digraph ranging from fully connected to 1-connected networks of nodes while allowing for differences in the network elements. This protocol does not rely on assumptions about the initial state of the system, other than the presence of at least one node, and no central clock or a centrally generated signal, pulse, or message is used. Nodes are anonymous, i.e., they do not have unique identities. There is no theoretical limit on the maximum number of participating nodes. The only constraint on the behavior of the node is that the interactions with other nodes are restricted to defined links and interfaces. This protocol deterministically converges within a time bound that is a linear function of the self-stabilization period. We present an outline of a deductive proof of the correctness of the protocol. A bounded model of the protocol was mechanically verified for a variety of topologies. Results of the mechanical proof of the correctness of the protocol are provided. The model checking results have verified the correctness of the protocol as they apply to the networks with unidirectional and bidirectional links. In addition, the results confirm the claims of determinism and linear convergence. As a result, we conjecture that the protocol solves the general case of this problem. We also present several variations of the protocol and discuss that this synchronization protocol is indeed an emergent system.

Malekpour, Mahyar R.↗

The Gamma Ray Observatory

The Gamma Ray Observatory (GRO), scheduled for launch by the Space Shuttle in April 1991, weighs 35,000 lbs and will offer 10 to 20 times better sensitivity than any previous gamma ray mission. The four instruments aboard GRO are described. The Burst and Transient Source Experiment (BATSE) will continuously monitor the entire sky for transient gamma-ray events using eight identical, wide-field detectors capable of measuring brightness variations lasting only milliseconds at energies from about 50,000 to 600,000 eV. The Oriented Scintillation Spectrometer Experiment (OSSE) will make comprehensive observations of discrete sources at energies from 100,000 to 10 million eV, where many radioactive elements have emission lines. The observatory's Imaging Compton Telescope will conduct a deep survey of the entire sky at gamma-ray energies between 1 and 30 MeV. The Energetic Gamma Ray Experiment Telescope will cover a broad high-energy spectral range, from about 20 million to 30 billion eV and conduct a sensitive all-sky survey with a wide field of view and good angular resolution.

Kniffen, Donald A.↗

Constraints on the chemical enrichment history of the Perseus Cluster of galaxies from high-resolution X-ray spectroscopy

High-resolution spectroscopy of the core of the Perseus Cluster of galaxies, using the Hitomi satellite above 2 keV and the XMM–Newton Reflection Grating Spectrometer at lower energies, provides reliable constraints on the abundances of O, Ne, Mg, Si, S, Ar, Ca, Cr, Mn, Fe, and Ni. Accounting for all known systematic uncertainties, the Ar/Fe, Ca/Fe, and Ni/Fe ratios are determined with a remarkable precision of less than 10 per cent, while the constraints on Si/Fe, S/Fe, and Cr/Fe are at the 15 per cent level, and Mn/Fe is measured with a 20 percent uncertainty. The average biases in determining the chemical composition using archival CCD spectra from XMM–Newton and Suzaku typically range from 15 to 40 per cent. A simple model in which the enrichment pattern in the Perseus Cluster core and the protosolar nebula are identical gives a surprisingly good description of the high-resolution X-ray spectroscopy results, with X^2=10.7 for 10 degrees of freedom. However, this pattern is challenging to reproduce with linear combinations of existing supernova nucleosynthesis calculations, particularly given the precise measurements of intermediateα-elements enabled by Hitomi. We discuss in detail the degeneracies between various supernova progenitor models and explosion mechanisms, and the remaining uncertainties in these theoretical models. We suggest that including neutrino physics in the core-collapse supernova yield calculations may improve the agreement with the observed pattern ofα-elements in the Perseus Cluster core. Our results provide a complementary benchmark for testing future nucleosynthesis calculations required to understand the origin of chemical elements.

A Simionescu↗

Phase equilibria and trace element partitioning in a magma ocean to 260 kilobars

A magma ocean can solidify in a way that is intermediate between perfect equilibrium and perfect fractional crystallization. In order to model quantitatively any fractional crystallization scenario, it is necessary to understand the geochemical characteristics of the phases that crystallize from a magma ocean, and how they vary with pressure. The crystallizing phase is called the liquidus phase, and their identities were determined by numerous experiments utilizing the multianvil apparatus. For chondritic compositions the liquidus phases are as follows: olivine at 1 atmosphere to 100 kilobars; garnet from 100 to about 260 kilobars; silicate perovskite from 260 kilobars to possibly the core-mantle boundary in the Earth.

Herzberg, Claude↗

On a study of the /Delta T/c and C/asterisk/ integrals for fracture analysis under non-steady creep

Applications of a vector quantity, path-independent integral which has an energy interpretation to the characterization of crack-tip fields in the range from fast to slow crack propagation are examined. The crack tip characterization parameter is defined in terms of a conservation integral for an area around the crack tip in a two-dimensional cracked body. The actual physical interpretation of the parameter is shown to be the difference in crack lengths displayed by two identical bodies which have equal load histories. A steady-state value is obtained for the parameter for cases of steady-state creep and is shown to be related to the standard path-independent integral for macroscopic self-similar crack growth under mode I conditions. A finite element model is developed for viscoplastic material models, using an initial strain approach with steps in a size employed in tangent stiffness methods.

Stonesifer, R. B.↗

Parallel Analog-to-Digital Image Processor

Proposed integrated-circuit network of many identical units convert analog outputs of imaging arrays of x-ray or infrared detectors to digital outputs. Converter located near imaging detectors, within cryogenic detector package. Because converter output digital, lends itself well to multiplexing and to postprocessing for correction of gain and offset errors peculiar to each picture element and its sampling and conversion circuits. Analog-to-digital image processor is massively parallel system for processing data from array of photodetectors. System built as compact integrated circuit located near local plane. Buffer amplifier for each picture element has different offset.

Lokerson, D. C.↗

Measurement Via Optical Near-Nulling and Subaperture Stitching

A subaperture stitching interferometer system provides near-nulling of a subaperture wavefront reflected from an object of interest over a portion of a surface of the object. A variable optical element located in the radiation path adjustably provides near-nulling to facilitate stitching of subaperture interferograms, creating an interferogram representative of the entire surface of interest. This enables testing of aspheric surfaces without null optics customized for each surface prescription. The surface shapes of objects such as lenses and other precision components are often measured with interferometry. However, interferometers have a limited capture range, and thus the test wavefront cannot be too different from the reference or the interference cannot be analyzed. Furthermore, the performance of the interferometer is usually best when the test and reference wavefronts are nearly identical (referred to as a null condition). Thus, it is necessary when performing such measurements to correct for known variations in shape to ensure that unintended variations are within the capture range of the interferometer and accurately measured. This invention is a system for nearnulling within a subaperture stitching interferometer, although in principle, the concept can be employed by wavefront measuring gauges other than interferometers. The system employs a light source for providing coherent radiation of a subaperture extent. An object of interest is placed to modify the radiation (e.g., to reflect or pass the radiation), and a variable optical element is located to interact with, and nearly null, the affected radiation. A detector or imaging device is situated to obtain interference patterns in the modified radiation. Multiple subaperture interferograms are taken and are stitched, or joined, to provide an interferogram representative of the entire surface of the object of interest. The primary aspect of the invention is the use of adjustable corrective optics in the context of subaperture stitching near-nulling interferometry, wherein a complex surface is analyzed via multiple, separate, overlapping interferograms. For complex surfaces, the problem of managing the identification and placement of corrective optics becomes even more pronounced, to the extent that in most cases the null corrector optics are specific to the particular asphere prescription and no others (i.e. another asphere requires completely different null correction optics). In principle, the near-nulling technique does not require subaperture stitching at all. Building a near-null system that is practically useful relies on two key features: simplicity and universality. If the system is too complex, it will be difficult to calibrate and model its manufacturing errors, rendering it useless as a precision metrology tool and/or prohibitively expensive. If the system is not applicable to a wide range of test parts, then it does not provide significant value over conventional null-correction technology. Subaperture stitching enables simpler and more universal near-null systems to be effective, because a fraction of a surface is necessarily less complex than the whole surface (excepting the extreme case of a fractal surface description). The technique of near-nulling can significantly enhance aspheric subaperture stitching capability by allowing the interferometer to capture a wider range of aspheres. More over, subaperture stitching is essential to a truly effective near-nulling system, since looking at a fraction of the surface keeps the wavefront complexity within the capability of a relatively simple nearnull apparatus. Furthermore, by reducing the subaperture size, the complexity of the measured wavefront can be reduced until it is within the capability of the near-null design.

Forbes, Greg↗

Short-term hot hardness characteristics of rolling-element steels

Short-term hot hardness studies were performed with five vacuum-melted steels at temperatures from 294 to 887 K (70 to 1140 F). Based upon a minimum Rockwell C hardness of 58, the temperature limitation on all materials studied was dependent on the initial room temperature hardness and the tempering temperature of each material. For the same room temperature hardness, the short-term hot hardness characteristics were identical and independent of material composition. An equation was developed to predict the short-term hardness at temperature as a function of initial room temperature hardness for AISI 52100, as well as the high-speed tool steels.

Chevalier, J. L.↗

A finite element method for time varying geometry in multibody structures

A three-dimensional finite element formulation using convected coordinates is presented for the multibody dynamics of truss-like configurations. Unlike existing formulations, the present one does not superimpose nonlinear rigid body kinematics with linear structural mode shapes, an approach that has recently been shown to be grossly inaccurate under certain conditions. Instead, the finite element method is extended to treat large motions/deformations. The formulation is oriented toward joint dominated structures and places the generalized coordinates at the joints. For the planar spin-up of a flexible beam, results are compared with those derived from a commercially available computer program. The two programs predict nearly identical results.

Housner, J. M.↗

The Initial Blood Storage Experiment - The spaceflight hardware program

The Initial Blood Storage Experiment (IBSE) was conceived to investigate the effects of microgravity on the formed elements of human blood. The experiment flew on the January 1986, 61-C mission of the Space Shuttle Columbia. The experiment hardware was designed to provide a closely controlled temperature and air flow environment for all blood samples. During the mission, two IBSE modules were on board the orbiter and an identical set of hardware and blood samples were maintained on earth as a control. This paper describes the development and performance of the IBSE hardware which was converted from a conceptual design to an on-orbit, man-rated, mid-deck locker experiment in 17 months.

Almgren, David W.↗

Highly Siderophile Element Abundances in Martian Meteorites

Critical evaluation of new and literature data for highly siderophile elements (HSE) in Martian (SNC) meteorites allows several first order conclusions to be drawn. (i) Re concentrations in SNC meteorites are nearly constant (within a factor of two) and do not correlate with rock type. Exceptions to this rule are Chassigny and Dar al Gani (DaG) 476, both of which are inferred to have experienced terrestrial Re contamination. (ii) Fractionations between Rh and Pd are small. Excluding Shergotty, the Rh/Pd ratio of the SNC suite is 0.22\pm0.05. (iii) Os and Ir contents vary by about four orders of magnitude; and positive correlations with MgO, Cr, and Ni suggest that these variations are not controlled by sulfide fractionation. A possible exception is the orthopyroxenite ALH84001, whose HSE's (including Ni, which is compatible in opx) are very low. (iv) Zagami, Shergotty, and Nakhla have nearly identical HSE signatures. Shergotty and Zagami have experienced assimilation-fractional crystallization (AFC) and have "crustal" Sr and Nd isotopic signatures. Conversely, the Nakhla parent was a small degree partial melt of a depleted mantle that interacted little with the Martian crust. These observations suggest that "evolved" HSE signatures can be produced by either fractional crystallization or small degrees of partial melting. (v) Chassigny and other mafic SNC's have HSE signatures that are very distinct from those of Nakhla-Zagami-Shergotty. The HSE elemental ratios of mafic SNC's approach chondritic, implying that the Martian mantle has nearly chondritic relative abundances of the HSE's. (vi) This chondritic HSE signature is observed in SNC's of various ages, suggesting that this is an ancient feature that has not evolved over time. (vii) No correlation is observed between HSE's and signatures of crustal contamination (e.g., Sr isotopes), indicating that the HSE signatures of the SNC suite are not derived from the crust. (vii) The Ru/Pd for the SNC suite ratio is about 0.5 chondritic. We attribute this depletion of Ru to the presence of spinel in the SNC source regions. (viii) Assignment of this depletion of Ru to spinel seems to also imply that spinel is not the cause of Os and Ir fractionations, requiring some other mafic phase to account for the observed variations. -----.

Jones, J. H.↗

Contact law and impact responses of laminated composites

Static identation tests were performed to determine the law of contact between a steel ball and glass/epoxy and graphite/epoxy laminated composites. For both composites the power law with an index of 1.5 was found to be adequate for the loading curve. Substantial permanent deformations were noted after the unloading. A high order beam finite element was used to compute the dynamic contact force and response of the laminated composite subjected to the impact of an elastic sphere. This program can be used with either the classical Hertzian contact law or the measured contact law. A simple method is introduced for estimating the contact force and contact duration in elastic impacts.

Sun, C. T.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Human Research Program Human Health Countermeasures Element Bone and Muscle Risk Standing Review Panel (SRP)

The Bone and Muscle Risk Standing Review Panel (SRP) met at the NASA Johnson Space Center (JSC) on October 4-6, 2009 to discuss the areas of current and future research targeted by the Human Health Countermeasures (HHC) Element of the Human Research Program (HRP). Using evidence-based knowledge as a background for identified risks to astronaut health and performance, NASA had identified gaps in knowledge to address those risks. Ongoing and proposed tasks were presented to address the gaps. The charge to the Bone and Muscle Risk SRP was to review the gaps, evaluate whether the tasks addressed these gaps and to make recommendations to NASA s HRP Science Management Office regarding the Panel's review. The Bone and Muscle Risk SRP consisted of scientists who are experts in muscle, bone, or both and could evaluate the existing evidence with sufficient knowledge of the potential effects of long duration exposure to microgravity. More important, although expertise in basic science is important, the SRP was requested to evaluate the practicality of the proposed efforts in light of the realistic demands placed on the HRP. In short, all tasks presented in the Integrated Research Plan (IRP) should address specific questions related to the challenges faced by the astronauts as a result of prolonged exposure to microgravity. All tasks proposed to fill the gaps in knowledge should provide applied, translational data necessary to answer the specific questions. Several presentations were made to the SRP during the site visit and the SRP spent sufficient time to address the panel charge, either as a group or in separate sessions for the Bone and Muscle Risk subgroups. The SRP made a final debriefing to the HRP Program Scientist, Dr. John B. Charles, on October 6, 2009. Taking the evidence and identified risks as givens, the SRP concluded that 1) integration of information should lead to a more comprehensive approach to identifying the gaps, 2) not all tasks addressed the gaps as stated in the IRP, 3) better access should be given to the SRP to existing data to include in its review, and 4) there were some missing gaps and tasks. As a result the SRP recommended 1) combining certain gaps, which in some cases were addressed with identical tasks, 2) additional gaps and tasks to address some of the gaps, 3) deleting some gaps and tasks to better focus the efforts of NASA s HRP in prioritizing their efforts, and 4) prioritizing gaps to address significant issues needing resolution in the short term while maintaining an awareness of long-term goals. The SRP commended the efforts by the HHC Element to integrate knowledge gaps and design tasks to address the higher order questions. This integration did not apply to the Bone and Muscle Risk alone, but the musculoskeletal system as its functions integrate with issues in

Glowacki, Julie↗

High-Velocity Absorption Features in FUSE Spectra of Eta Carinae

Numerous broad (200 to 1000 km/sec) features in the FUSE spectrum (905-1187 A) of eta Carinae are identified as absorption by a forest of high-velocity narrow lines formed in the expanding circumstellar envelope. These features were previously thought to be P-Cygni lines arising in the wind of the central star. The features span a heliocentric velocity range of -140 to -580 km/sec and are seen prominently in low-ionization ground-state transitions (e.g. N I 1134-35, Fe II 1145-42, 1133, 1127- 22, P II 1153, C I 1158) in addition to C III] 1176 A. The high-velocity components of the FUSE transitions have depths about 50% below the continuum. The identifications are consistent with the complex velocity structures seen in ground- and excited-state transitions of Mg I, Mg 11, Fe II, V II, etc observed in STIS/E230H spectra. The origin of other broad features of similar width and depth in the FUSE spectrum, but without low-velocity ISM absorption, are unidentified. However, they are suspected of being absorption of singly-ionized iron-peak elements (e.g. Fe II, V II, Cr II) out of excited levels 1,000 to 20,000 cmE-l above the ground state. The high-velocity features seen in Fe II 1145 are also present in Fe II 1608 (STIS/E140M), but are highly saturated in the latter. Since these transitions have nearly identical log (flambda) (1.998 vs. 2.080), the differences in the profiles are attributable to the different aperture sizes used (30 x 30 arcsec for FUSE, 0.2 x 0.2 arcsec for STIS/E140M). The high-velocity gas appears to be very patchy or has a small covering factor near the central star. Eta Carinae has been observed several times by FUSE over the past three years. The FUSE flux levels and spectral features in eta Car are essentially unchanged over the 2000 March to June 2002 period, establishing a baseline far-UV spectrum in advance of the predicted spectroscopic minimum in 2003.

Sonneborn, G.↗

How actin crosslinking and bundling proteins cooperate to generate an enhanced cell mechanical response

Actin-crosslinking proteins organize actin filaments into dynamic and complex subcellular scaffolds that orchestrate important mechanical functions, including cell motility and adhesion. Recent mutation studies have shown that individual crosslinking proteins often play seemingly non-essential roles, leading to the hypothesis that they have considerable redundancy in function. We report live-cell, in vitro, and theoretical studies testing the mechanical role of the two ubiquitous actin-crosslinking proteins, alpha-actinin and fascin, which co-localize to stress fibers and the basis of filopodia. Using live-cell particle tracking microrheology, we show that the addition of alpha-actinin and fascin elicits a cell mechanical response that is significantly greater than that originated by alpha-actinin or fascin alone. These live-cell measurements are supported by quantitative rheological measurements with reconstituted actin filament networks containing pure proteins that show that alpha-actinin and fascin can work in concert to generate enhanced cell stiffness. Computational simulations using finite element modeling qualitatively reproduce and explain the functional synergy of alpha-actinin and fascin. These findings highlight the cooperative activity of fascin and alpha-actinin and provide a strong rationale that an evolutionary advantage might be conferred by the cooperative action of multiple actin-crosslinking proteins with overlapping but non-identical biochemical properties. Thus the combination of structural proteins with similar function can provide the cell with unique properties that are required for biologically optimal responses.

Non-NASA Center↗

Fine structure of the sun at 1.3 cm wavelength

The two-element interferometer at Hat Creek Observatory was used at 1.3-cm wavelength to study the fine structure of the radio emissive regions on the sun. Observations of the quiet sun at 1.3 cm show sudden changes in the fringe amplitude and phase, lasting for typically about 5 to 8 min. Assuming that these events are identical in nature, a plot of peak amplitude vs the projected baseline at the time of the event suggests emission from a region of angular size of about 10 sec. The corresponding brightness temperature is 50,000 K. It is possible that these events may be related to the appearance and disappearance of groups of spicules or mottles.

Kundu, M. R.↗