Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high renewable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report for GROWTH-MSI at Sonoma University

This final technical report describes the goals, activities, outcomes, and broader impacts of the GROWTH-MSI program, supported through the DOE RENEW Initiative in High Energy Physics. The program established a 1.5-year traineeship for undergraduate students from six Northern California Minority Serving Institutions, connected students with DOE laboratory research mentors, provided particle physics coursework and professional development, and advanced HEP research infrastructure at CSU Stanislaus and Sonoma State University.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Opening Up Transactive Systems: Introducing TESS and Specification in a Field Deployment

Transactive energy systems (TS) use automated device bidding to access (residential) demand flexibility and coordinate supply and demand on the distribution system level through market processes. In this work, we present TESS, a modularized platform for the implementation of TS, which enables the deployment of adjusted market mechanisms, economic bidding, and the potential entry of third parties. TESS thereby opens up current integrated closed-system TS, allows for the better adaptation of TS to power systems with high shares of renewable energies, and lays the foundations for a smart grid with a variety of stakeholders. Furthermore, despite positive experiences in various pilot projects, one hurdle in introducing TS is their integration with existing tariff structures and (legal) requirements. In this paper, we therefore describe TESS as we have modified it for a field implementation within the service territory of Holy Cross Energy in Colorado. Importantly, our specification addresses challenges of implementing TS in existing electric retail systems, for instance, the design of bidding strategies when a (non-transactive) tariff system is already in place. We conclude with a general discussion of the challenges associated with “brownfield” implementation of TS, such as incentive problems of baseline approaches or long-term efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Centralized and Decentralized Distributed Energy Resource Access Control Implementation Considerations.

A global transition to power grids with high penetrations of renewable energy generation is being driven in part by rapid installations of distributed energy resources (DER). New DER equipment includes standardized IEEE 1547-2018 communication interfaces and proprietary communications capabilities. Interoperable DER provides new monitoring and control capabilities. The existence of multiple entities with different roles and responsibilities within the DER ecosystem makes the Access Control (AC) mechanism necessary. In this paper, we introduce and compare two novel architectures, which provide a Role-Based Access Control (RBAC) service to the DER ecosystem’s entities. Selecting an appropriate RBAC technology is important for the RBAC administrator and users who request DER access authorization. The first architecture is centralized, based on the OpenLDAP, an open source implementation of the Lightweight Directory Access Protocol (LDAP). The second approach is decentralized, based on a private Ethereum blockchain test network, where the RBAC model is stored and efficiently retrieved via the utilization of a single Smart Contract. We have implemented two end-to-end Proofs-of-Concept (PoC), respectively, to offer the RBAC service to the DER entities as web applications. Finally, an evaluation of the two approaches is presented, highlighting the key speed, cost, usability, and security features.

42 ENGINEERING↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This presentation was given by Marc Turner, NETL Support Contractor, at the International Center for Sustainable Carbon's "The Energy Transition - the Role for Sustainable Carbon" workshop held in Sardinia, Italy on November 16-18, 2022. The presentation addresses the NETL report titled "Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation" published on September 6, 2022. This study presents an independent conceptual assessment of the features, cost, and performance of pulverized coal power plants (without carbon dioxide capture) intended for flexible, rather than baseload, operation. The objective was to leverage the already substantial knowledge base about flexible operation and develop state-of-the-art pulverized coal power plant cases that are designed to accommodate flexible operation within an electric grid having a high level of renewable generation. This is of significant importance in coal-dependent regions of the world as variable renewable energy becomes more prevalent.

Turner, Marc↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the IEEE 73-bus reliability test system (RTS) case via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own.

IBRs↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Swing Contract-Based Valuation for Distributed Energy Resources in Transactive Energy Systems: A Reinforcement Learning Approach

With the proliferation of distributed energy resources (DERs) and power grids with high fractions of renewable energy, market constructs are evolving to allow DERs to participate in multiple possible markets, at different levels of grid hierarchy. The effective participation of DERs in market environments is aided by swing contract-based pricing mechanisms, whereby DERs have a two-part compensation structure – one for their reservation/commitment and another for performancedriven ex-post payment for their actual mobilization during dispatch. In this paper, we propose a reinforcement learningbased (Q-learning) approach that allows a rational DER agent to select the market it wants to participate in within a composite market environment where individual markets are coordinated by possibly different actors. The proposed Q-learning framework aids DERs in their self-valuation by implicitly maximizing their own payoff through market participation, assuming a swing contract-based compensation structure. We complement our work through simulation-based investigations where factors affecting the DER decision making process, such as parametric uncertainties in market (and grid) environments, are studied.

Naqvi, Syed Ahsan Raza↗

Using multiple high-resolution datasets to benchmark the energy exascale earth system model (E3SM) for renewable resource assessment

The United States is accelerating its shift toward a renewable energy system. However, renewable resources, which harness energy from the Earth system, are susceptible to both present-day climate variability and future climate change. For example, variations in regional climate can alter renewable energy production patterns and site viability. The use of high-resolution climate model projections can therefore facilitate and may be critical to long-term planning of renewable energy investments. However, climate models must first be validated for renewable resource assessment. This research employs multiple high-spatiotemporal-resolution datasets to assess the capability of the Department of Energy’s (DOE) Energy Exascale Earth System Model version 2 North American Regionally Refined Model (E3SMv2-NARRM) for predicting multi-year climatological values of solar and wind energy capacity factors in the continental U.S., with a focus on regional and seasonal variability. Present-day E3SMv2-NARRM simulations are compared with reported utility-scale production data obtained from the Energy Information Administration (EIA). In addition, E3SMv2-NARRM data are evaluated against non-climate benchmark models from the National Renewable Energy Laboratory, including the Wind Integration National Dataset Toolkit and the National Solar Radiation Database (NSRDB), as well as three wind energy datasets from PLUSWIND. Our analysis indicates that solar capacity factors from E3SM closely match those from the NSRDB dataset. However, both datasets tend to overestimate values by 10% in comparison to EIA data. Furthermore, biases in wind capacity factors within E3SM are notably pronounced in the West Coast regions, where the seasonal cycle diverges from EIA data.

Energy forecasting, Capacity factor, Renewable ene↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

High-Power and Flexible Low-Frequency AC Transmission for Renewable Integration

This project develops a steady-state, dynamic, and production cost models of a multi-terminal, high-power, flexible low-frequency ac (LF-HVac) transmission system with grid-forming converters. Through both numerical analysis and EMTP simulation, the project goal is to demonstrate the feasibility of such an innovative and transformative LF-HVac system to support bulk integration of large-scale, cheap, and steady renewable resources from remote locations such as offshore wind farms to meet recent clean energy goals from DOE. The proposed adoption of low-frequency ac transmission aims to improve power transfer capability for remote large-scale renewable integration. In addition, the control for power electronics converters provides grid-support functions to improve the flexibility and resilience the existing 60-Hz HVac system. Future projects on this topic can be supported by both Energy Efficiency and Renewable Energy (DOEEE) and Office of Electricity Delivery & Energy Reliability (DOEOE) offices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Assessment of Deploying Advanced Pumped Storage Hydropower Technology in U.S. Electricity Markets

Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗