Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heterodyne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Submillimeter local oscillators for spaceborne heterodyne applications

Existing and prospective submillimeter local oscillator technologies are surveyed and compared with respect to criteria of suitability for application in spaceborne submillimeter heterodyne receivers as those proposed for the Large Deployable Reflector (LDR). Solid-state and plasma devices are considered in terms of fundamental limitations.

Petuchowski, S. J.↗

Heterodyne frequency measurements on N2O at 5.3 and 9.0 microns

Heterodyne frequency measurements on the 01(1)1-00(0)0 band of N2O have been made with the use of a tunable-diode laser, CO laser transfer oscillator, and a CO2 laser frequency synthesizer. A beat frequency was measured between a CO laser and tunable-diode laser whose frequency was locked to the peak of N2O absorption features. The frequency of the CO laser was simultaneously determined by neasuring the beat frequency with respect to a reference synthesized from two CO2 lasers. New rovibrational constants are given for the 01(1)1 state of N2O, which are in excellent agreement with previous results, although the band center is 4 MHz higher than in the previous measurements. A table for the line frequencies and their absolute uncertainties is given for the N2O absorption lines in the wave-number region from 1830 to 1920 kaysers. Some additional frequency measurements near the lower-frequency end of the 02(0)0-00(0)0 band have also been made with respect to a C-12)(0-18)2 laser.

Wells, J. S.↗

Electronic heterodyne readout of fringes in moire deflectometry

An electronic heterodyne technique is described for the readout of fringes in moire deflectometry. The technique is based on phase measurements of signals generated by a photodetector observing the light transmitted through a traveling moire fringe pattern. The phase of the signal is proportional to the fringe deviation and thus to the deflection angle of the light ray. The phase is measured on line by a standard phase meter with an accuracy of 1 deg or 1:360 of a fringe. The technique, which is precise and sensitive, is demonstrated by detecting and measuring a fringe shift of 0.15 mm corresponding to 0.029 of a fringe.

Stricker, J.↗

A heterodyne receiver for the submillimeter wavelength region based on cyclotron resonance in InSb at low temperatures

A heterodyne receiver has been developed for observation of interstellar atomic and molecular lines in the submillimeter wavelength region. The main detection mechanism of the device is cyclotron resonance in bulk n-InSb due to a quantized magnetic field. Measurements were carried out between 492 and 812 GHz in order to determine the sensitivity of the device for astrophysical applications. Double sideband receiver noise temperatures of 250 K at 492 GHz; 350 K at 625 GHz; and 510 K at 812 GHz were obtained. The magnetic induction for the laboratory tests was about 2.5 KG and the mixer operating temperature was about 1.6 K. It is shown that the receiver is sensitive enough to identify the narrow rotation lines of diatomic hydrides in dark-cloud regions of the interstellar medium.

Brown, E. R.↗

Laser heterodyne spectrometer for helioseismology

The technique of laser heterodyne spectroscopy has been applied to the measurement of solar oscillations. Coherent mixing of solar radiation with the output of a frequency-stabilized CO2 laser permits the measurement of fully resolved profiles of solar absorption lines with high spectral purity and excellent frequency stability. This technique has been used to measure OH pure rotation lines in the infrared solar spectrum. Power spectra of these line frequency measurements show the well-known 5-min oscillations as well as significant velocity power at shorter periods.

Glenar, D. A.↗

Determination of the C-12/C-13 and O-16/O-18 ratio in the Martian atmosphere by 10 micron heterodyne spectroscopy

The planetary atmosphere of Mars was studied during the opposition of May, 1984, by means of a 10-micron heterodyne receiver mounted at the Cassegrain focus of a 3-m telescope. On the basis of a model of the Martian atmosphere, the isotopic ratios derived from the fully resolved absorption spectra obtained were compared with the results of Viking probe in situ measurements and terrestrial values; agreement is obtained within statistical errors. It is shown that highly resolving spectroscopy allows for the determination of isotopic ratios in remote sensing with a precision that is comparable to that of in situ mass spectroscopy.

Schrey, U.↗

Diffraction effects and special advantages in electronic heterodyne moire deflectometry

Effects of diffraction on the performance of electronic heterodyne readout of moire fringes are investigated. The sensitivity, accuracy, and resolution of the system are calculated, and it is shown that these features are significantly improved compared with the conventional intensity moire readout technique. The sensitivity of the system can be tripled without changing the distance between gratings. The system was evaluated experimentally by measuring the refractive-index derivatives of a weak phase object consisting of a large KD(asterisk)P crystal. Effects of nonlinear fringe modulation were studied both theoretically and experimentally. It is shown that in this case the electronic phase is not linearly related to the fringe shift, and calibration of the system is necessary.

Stricker, J.↗

Far-infrared heterodyne spectroscopy

A new far-infrared heterodyne spectrometer has been built for ground-based observations at the Cassegrain focus. The receiver, which features a Schottky-diode mixer and a laser local oscillator, was used in January 1984, to detect the 809 GHz fine-structure line of neutral carbon in OMCl. A second-generation version of the spectrometer is now being constructed for airborne observations between 600 and 1500 GHz.

Betz, A. L.↗

Laser heterodyne system for obtaining height profiles of minor species in the atmosphere

An infrared laser heterodyne system for obtaining height profiles of minor constituents of the atmosphere was developed and erected. A brief discription of the system is given. The system consists of a tunable CO2 waveguide laser in the 9 to 11 micrometer band, that is used as a local oscillator and a heliostat that follows the sun and brings in solar radiation, that is mixed with the laser beam in a high speed liquid nitrogen cooled mercury cadmium telluride detector. The detected signal is analysed in a RF spectrum analyser that allows tracing absorption line profiles. Absorption lines of a number of minor constituents in the troposphere and stratosphere, such as O3, NH3, H2O, SO2, ClO, N2O, are in the 9 to 11 micrometer band and overlap with that of CO2 laser range. The experimental system has been made operational and trial observations taken. Current measurements are limited to ozone height profiles. Results are presented.

Jain, S. L.↗

NO2 heterodyne frequency measurements with a tunable diode laser, a CO laser transfer oscillator and CO2 laser standards

Heterodyne frequency measurements have been made on selected groups of nitrogen dioxide rovibronic transitions between 1580.8 and 1650.7/cm. The groups are separated by 7 to 10/cm, and the intent is to provide a limited (and interim) calibration table for the region. In addition to a table of measured frequencies in the region, figures of spectra in the vicinity of the measured lines are included to provide a map for identifying the transitions measured.

Zink, L. R.↗

Heterodyne spectroscopy of the 158 micron C II line in M42

Velocity-resolved spectra of the C-12 II 157.8-micron 2P3/2-2P1/2 fine-structure line in the M42 region of Orion have been obtained. Observations at 0.8 km/s resolution with a laser heterodyne spectrometer show multiple velocity components in some locations, with typical linewidths of 3-5 km/s. Spectra of theta C and BN-KL also show weak emission from the F = 2-1 hyperfine component of the equivalent C-13 II line. From the observed C-12 II/C-13 II line intensity ratios, it is deduced that the C-12 II emission is optically thick with tau of about 5 at both positions.

Boreiko, R. T.↗

The UCB/MPE Cassegrain Submillimeter Heterodyne Spectrometer

The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for astronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acoustooptical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J = 7-6 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (less than 2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.

Harris, A. I.↗

Sources of error in heterodyne moire deflectometry

Alignment problems, and the accompanying errors, in heterodyne moire deflectometry are considered. A change in the x-directed offset between two states of a phase object causes a constant phase error, and it is noted that the relative x coordinate of the two photographic plates (the two states of the phase object) must be positioned typically within 1 micron to avoid a detectable offset. Possible solutions for assuring the relative alignment of the two deflectograms are considered, including a sandwich technique and a two-color double-exposure implementation.

Decker, Arthur J.↗

Germanium:gallium photoconductors for far infrared heterodyne detection

Highly compensated Ge:Ga photoconductors for high bandwidth heterodyne detection have been fabricated and evaluated. Bandwidths up to 60 MHz have been achieved with a corresponding current responsivity of 0.01 A/W. The expected dependence of bandwidth on bias field is obtained. It is noted that increased bandwidth is obtained at the price of greater required local oscillator power.

Park, I. S.↗

Heterodyne spectroscopy of the J = 17-16 CO line in Orion

High-resolution spectra of the 153 micron J = 17-16 CO line in the BN-KL region of Orion using a laser heterodyne spectrometer are obtained. The line shows broad wings characteristic of the plateau emission as well as a narrower component probably associated with the quiescent gas in the molecular ridge. From an analysis of the plateau emission together with that observed in lower J CO transitions, an excitation temperature of 180 + or - 50 K and minimum column density of 1 x 10 to the 18th /sq cm are derived for CO in this component, which constitutes 80 percent of the total integrated intensity of the J = 17-16 line near BN. The peak intensity of the narrower component observed at 0.8 km/s resolution increases relative to that of the plateau component toward theta 1C and away from BN, while the width decreases from 10 to 4 km/s (FWHM).

Boreiko, R. T.↗

Design and simulated performance of a CARS spectrometer for dynamic temperature measurements using electronic heterodyning

A new design for generating CARS signals and for the detection and processing of these signals is presented and evaluated. The design is based on electronic heterodyning of the CARS spectrum of nitrogen at two selected narrowband frequencies, ratioing the resulting signal strengths, and comparing this ratio with a theoretically derived temperature scale. A reference cell is incorporated into the design for system calibration and for accurate temperature measurements. The spectrometer is found capable of measuring temperature in the submillisecond time scale with an accuracy of 10 percent in the 1000-2000 K temperature range. A typical result using the Hg(x)Cd(1-x)Te photomixer for T = 1500 K, Delta T = 50 K is a SNR of 21 dB and a data collection rate of 300 Hz.

Deen, M. Jamal↗

Far-infrared heterodyne receivers

The development of open resonator mixer structures and laser local oscillators has made heterodyne spectroscopy at far infrared (FIR) wavelengths between 150 and 400 microns a reality. Several laser based receivers are now part of the instrument complement flown aboard the Kuiper Airborne Observatory. Lasers are eminently practical as FIR local oscillators whenever there is close frequency coincidence between a strong laser transition and the Doppler-shifted astronomical line. While it is desirable to have continuous frequency coverage in a spectrometer, it should be recognized that most astronomers will focus their interest on the few spectral lines deemed optimum for probing the cosmos. Ultimately, the development of a reliable thin film technology for the new high temperature oxide superconductors may favor SIS-type devices for all wavelengths in future space based FIR receivers.

Betz, Albert↗

Absolute wind measurements in the lower thermosphere of Venus using infrared heterodyne spectroscopy

The first absolute wind velocities above the Venusian cloud-tops were obtained using NASA/Goddard infrared heterodyne spectrometers at the NASA Infrared Telescope Facility (IRTF) and the McMath Solar Telescope. Beam-integrated Doppler displacements in the non-thermal emission core of (12)C(16)O2 10.33 micron R(8) sampled the line of sight projection of the lower thermospheric wind field (100 to 120 km). A field-usable Lamb-dip laser stabilization system, developed for spectrometer absolute frequency calibration to less than + or - 0.1 MHz, allowed S/N-limited line of sight velocity resolution at the 1 m/s level. The spectrometer's diffraction-limited beam (1.7 arc-second HPBW at McMath, 0.9 arc-second HPBW at IRTF), and 1 to 2 arc-second seeing, provided the spatial resolution necessary for circulation model discrimination. Qualitative analysis of beam-integrated winds provided definitive evidence of a dominant subsolar-antisolar circulation in the lower thermosphere. Beam-integrated winds were modelled with a 100x100 grid over the beam, incorporating beam spatial rolloff and across-the-beam gradients in non-thermal emission intensity, line of sight projection geometry, and horizontal wind velocity. Horizontal wind velocity was derived from a 2-parameter model wind field comprised of subsolar-antisolar and zonal components. Best-fit models indicated a dominant subsolar-antisolar flow with 120 m/s cross-terminator winds and a retrograde zonal component with a 25 m/s equatorial velocity. A review of all dynamical indicators above the cloud-tops allowed development of an integrated and self-consistent picture of circulation in the 70 to 200 km range.

Goldstein, Jeffrey J.↗