Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heavy ion testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Mechanisms of Heavy Ion-Induced Single Event Burnout in 4H-SiC Power MOSFETs

This describes the mechanisms behind the failure of 4H-SiC Power MOSFETs when struck by a heavy ion. The modeled device is designed to simulate a commercially available 1200 V power MOSFET and the ion simulated is a silver ion with a Linear Energy Transfer of 46 MeV-cm2/mg commonly used in single event effect (SEE) testing. The device is shown in simulation to fail near 500 V, which is in close agreement to experiments. These simulations go to show that the failure of SiC MOSFET occurs near the interface between the epi and substrate layers due to the rapid increase of the electric field in that region and destruction of the device from impact ionization. From this, two designs were proposed and investigated that would help to mitigate the electric field in these regions and improve the device's tolerance to single-event burnout (SEB). The new designs increased the voltage at which SEB occurs from 500 V to over 900 V and increased the Ron,sp by only 5%.

Mcpherson, Joseph A.↗

Performance study of galactic cosmic ray shield materials

The space program is faced with two difficult radiation protection issues for future long-term operations. First, retrofit of shield material or conservatism in shield design is prohibitively expensive and often impossible. Second, shielding from the cosmic heavy ions is faced with limited knowledge on the physical properties and biological responses of these radiations. The current status of space shielding technology and its impact on radiation health is discussed herein in terms of conventional protection practice and a test biological response model. The impact of biological response on the selection of optimum materials for cosmic ray shielding is presented in terms of the transmission characteristics of the shield material. Although the systematics of nuclear cross sections are able to demonstrate the relation of exposure risk to shield-material composition, the current uncertainty in-nuclear cross sections will not allow an accurate evaluation of risk reduction. This paper presents a theoretical study of risk-related factors and a pilot experiment to study the effectiveness of choice of shield materials to reduce the risk in space operations.

Kim, Myung-Hee Y.↗

Determination Of LETs Of SRAMs By Use Of A Laser

Report describes experimental study of use of microelectronic advanced laser scanner (MEALS) to cause single-event upsets (SEUs) in integrated logic circuits. Basic concepts of SEU testing by use of MEALS described in "Laser Scanner Tests for Single-Event Upsets" (NPO-18216), "Single-Event-Upset Laser Scanner With Optical Bias" (NPO-18217), and "More About Laser Scanner Tests for Single-Event Upsets" (NPO-18494). Study part of continuing effort to study SEU effects of ionizing radiation on such circuits and to use MEALS as relatively inexpensive SEU-prescreening laboratory apparatus serving as alternative to heavy-ion acclerator.

Kim, Quiesup↗

An Examination of Heavy Ion-Induced Persistent Visual Error Signatures in an Electronic Display Driver Integrated Circuit

Heavy ion irradiation of a display driver integrated circuit (DDIC) was performed, and persistent visual error signatures were captured. Based on the heavy ion results, error signatures were localized to configuration registers motivate potential mitigation techniques and observations relating to single event effect susceptibility. DDICs serve as an integral component of integrated display systems that will require the development of single event effects test methodologies in anticipation of extensive use in crewed spacecrafts outside of the Earth’s geomagnetic protection.

Electronic Displays↗

Single Event Effects Test Report Vishay Siliconix Si7113DN P-Channel 100V MOSFET

This study was undertaken to determine the destructive single event effect and degradation susceptibility of the Si7113DN P-Channel 100V MOSFET from Vishay Siliconix. The device was monitored for destructive single event effects and degradation during exposure to a heavy ion beam at the Berkely Accelerator Space Effects (BASE) Facility at the Lawrence Berkely National Laboratory (LBNL).

MOSFET↗

Observation of a two-temperature ion energy distribution in regions of polar wind flow

Study of deviations from thermal equilibrium among the ions in the ionosphere by considering that the 'light' ions H(+) and He(+) may be at a different temperature from the 'heavy' ion O(+). In particular, the case in which thermal protons are observed to be flowing relative to the assumed static ambient oxygen ions is considered. The proton flow is assumed to be along the direction of the magnetic field. Of the cases tested, it is found that the measured proton temperature is from one to ten times the measured oxygen ion temperature. Such temperature enhancements may be expected both because of the energy transfer associated with the ion flow and as a consequence of the preferential energy coupling from the light-ion distribution in the exosphere.

Maier, E. J.↗

Issues in Space Radiation Protection: Galactic Cosmic Rays

With shielding from cosmic heavy ions, one is faced with limited knowledge about the physical properties and biological responses of these radiations. Herein, the current status of space shielding technology and its impact on radiation health is discussed in terms of conventional protection practice and a test biological response model. The impact of biological response on optimum materials selection for cosmic ray shielding is presented in terms of the transmission characteristics of the shield material. Although liquid hydrogen gas is an optimum shield material, evaluation of the effectiveness of polymeric structural materials must await improvement in our knowledge of both the biological response and the nuclear processes.

Wilson, J. W.↗

Effects of heavy ions on visual function and electrophysiology of rodents: the ALTEA-MICE project

ALTEA-MICE will supplement the ALTEA project on astronauts and provide information on the functional visual impairment possibly induced by heavy ions during prolonged operations in microgravity. Goals of ALTEA-MICE are: (1) to investigate the effects of heavy ions on the visual system of normal and mutant mice with retinal defects; (2) to define reliable experimental conditions for space research; and (3) to develop animal models to study the physiological consequences of space travels on humans. Remotely controlled mouse setup, applied electrophysiological recording methods, remote particle monitoring, and experimental procedures were developed and tested. The project has proved feasible under laboratory-controlled conditions comparable in important aspects to those of astronauts' exposure to particle in space. Experiments are performed at the Brookhaven National Laboratories [BNL] (Upton, NY, USA) and the Gesellschaft fur Schwerionenforschung mbH [GSI]/Biophysik (Darmstadt, FRG) to identify possible electrophysiological changes and/or activation of protective mechanisms in response to pulsed radiation. Offline data analyses are in progress and observations are still anecdotal. Electrophysiological changes after pulsed radiation are within the limits of spontaneous variability under anesthesia, with only indirect evidence of possible retinal/cortical responses. Immunostaining showed changes (e.g. increased expression of FGF2 protein in the outer nuclear layer) suggesting a retinal stress reaction to high-energy particles of potential relevance in space. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

RH1020 Single Event Clock Upset Summary Report

This report summarizes the testing and analysis of "single event clock upset' in the RH1020. Also included are SEU-rate predictions and design recommendations for risk analysis and reduction. The subject of "upsets" in the RH1020 is best understood by using a model consisting of a global clock buffer and a D-type flip-flop as the basic memory unit. The RH1020 is built on the ACT 1 family architecture. As such, it has one low-skew global clock buffer with a TTL-level input threshold that is accessed via a single dedicated pin. The clock signal is driven to full CMOS levels, buffered, and sent to individual row buffers with one buffer per channel. For low-skew performance, the outputs of all of the RH1020 row buffers are shorted together via metal lines, as is done in the A1020B. All storage in the RH1020 consists of routed flip-flops, constructed with multiplexors and feedback through the routing segments. A simple latch can be constructed from a single (combinatorial or C) module; an edge-triggered flip-flop is constructed using two concatenated latches. There is no storage in the I/O modules. The front end of the clock buffering circuitry, at a common point relative to the row buffer, is a sub-circuit that was determined to be the most susceptible to heavy ions. This is due, in part, to its smaller transistors compared to the rest of the circuitry. This conclusion is also supported by SPICE simulations and an analysis of the heavy ion data, described in this report. The edge triggered D flip-flop has two single-event-upset modes. Mode one, called C-module upset, is caused by a heavy ion striking the C-module's sensitive area on the silicon and produces a soft single bit error at the output of the flip-flop. Mode two, called clock upset, is caused by a heavy ion strike on the clock buffer, generating a runt pulse interpreted as a false clock signal and consequently producing errors at the flip-flop outputs. C-module upset sensitivity in the RH1020 is essentially the same as that of its ACT 1 siblings (A1020, A1020A and A1020B), which were well tested, analyzed, and documented in the literature.

Katz, Richard B.↗

Single-Event Effect Test Report Texas Instruments DS25BR100 LVDS Buffer

This study was to determine the destructive single-event effect (SEE) susceptibility of the DS25BR100 series Low-Voltage Differential Signaling (LVDS) Buffers with Pre-emphasis and Equalization (DS25BR100, 110, and 120). The device was monitored primarily for destructive events while exposing it to a heavy ion beam at the Texas A&M University’s (TAMU) K500 Cyclotron.

Ted Wilcox↗

Neon transport in selected organic composites

An energy-dependent, perturbation expansion solution for heavy-ion transport in one dimension was used to calculate the dose from Ne-20 beams at incident kinetic energies of 350, 670, and 2000 MeV/amu onto selected organic composites. Transport coefficients, applicable to arbitrary ion beams over a broad range of energies, are presented. Polyethylene and Kapton were tested as constituents of multilayered shielding for spacecraft and astronauts.

Townsend, L. W.↗

Processing technology for high efficiency silicon solar cells

Recent advances in silicon solar cell processing have led to attainment of conversion efficiency approaching 20%. The basic cell design is investigated and features of greatest importance to achievement of 20% efficiency are indicated. Experiments to separately optimize high efficiency design features in test structures are discussed. The integration of these features in a high efficiency cell is examined. Ion implantation has been used to achieve optimal concentrations of emitter dopant and junction depth. The optimization reflects the trade-off between high sheet conductivity, necessary for high fill factor, and heavy doping effects, which must be minimized for high open circuit voltage. A second important aspect of the design experiments is the development of a passivation process to minimize front surface recombination velocity. The manner in which a thin SiO2 layer may be used for this purpose is indicated without increasing reflection losses, if the antireflection coating is properly designed. Details are presented of processing intended to reduce recombination at the contact/Si interface. Data on cell performance (including CZ and ribbon) and analysis of loss mechanisms are also presented.

Spitzer, M. B.↗

Delta excitations and shell-model information in heavy-ion, charge-exchange reactions

We calculate total cross sections for coherent pion production using localized plane-wave approximations for the shell-structure of valence nucleons that are excited to delta particles in the intermediate state in the (12C, 12B) and (12C, 12N) charge-exchange, heavy-ion reactions. We find comparable agreement to projectile downshift data for 12C(12C, 12B)12N. Then we improve the formalism by replacing the localized plane wave bound states with harmonic oscillator states which are imbedded in a multipole expansion approach and calculate pion differential cross sections to test for the sensitivity of the spectra to the single-particle mass parameter.

NASA Program Space Medicine↗

NSBRI Radiation Effects: Carcinogenesis in Sprague-Dawley Rats Irradiated with Iron Ions, Protons, or Photons

Our ability to confidently develop appropriate countermeasures for radiations in space in terms of shielding and design of a spacecraft, the mission scenario, or chemoprevention is severely limited by the uncertainties in both the risk itself and the change in that risk with intervention. Despite the fact that the risk of carcinogenesis from exposures of personnel to radiations on long-term missions is considered one of the worst hazards in space, only a limited amount of in-vivo data exist for tumor induction from exposures to protons or energetic heavy ions (HZEs) at lower doses. The most extensive work remains the landmark study. for tumor development in the harderian gland of the mouse. The objective of this study is to characterize the level of risk for tumor induction in another relevant animal model. Subsequent experiments are designed to test the hypothesis that the level of risk can be reduced by pharmaceutical intervention in the promoting and progressing stages of the disease rather than in the initiating stage. The work presented here results from a cooperative effort on the part of investigators from two projects of the Radiation-Effects Team of the National Space Biomedical Research Institute (NSBRI). The collaborating projects are the Core Project which is investigating the risk of carcinogenesis in Sprague-Dawley rats and the Chemoprevention Project which is investigating the ability of Tamoxifen to reduce the number of malignant tumors in the irradiated animals. Research at the cellular and subcellular levels is being conducted in two other projects of the Radiation-Effects Team, Cytogenetics with J. R. Williams as Principal Investigator and Mutations from Repeated DNA Sequences. Results for these other projects also are being presented at this Workshop.

Dicello, J. F.↗

Comparisons of Selected Atmospheric Escape Mechanisms on Venus, Mars and Titan

The similarities and differences of the escape mechanisms for H+ and D+ from Venus, H+ and D+ from Mars, and heavier ions (approximately 17 and approximately 28 amu) from Titan are described. The dominant escape process for hydrogen and deuterium on Venus is thought to originate in the night side ionosphere, located in the night side H and D bulge region, where the polarization electric field is the dominant force accelerating ionospheric H+ and D+ upward into the induced magnetic tail of Titan. The resulting loss rates approximately 8.6 x 10(exp26)/s and approximately 3.2 x 10(exp 23)/s for H+ and D+, respectively, are consistent with the large observed D/H ratio - 160 times that of terrestrial water and an ancient ocean more than 10 m of liquid uniformly distributed on the surface. In contrast, Jeans escape is the dominant loss mechanism for H and D on Mars, which has a D/H ratio approximately 5.3 times that of terrestrial water. The resulting loss rates for H and D of approximately 3.7 x 10(exp 26/s and approximately 10(exp 22)/s, respectively, can be related to possible ancient water reservoirs below the surface. When horizontal atmospheric winds are taken into account, the Jeans escape rates for H and D are enhanced considerably, as are the corresponding water reservoirs. On Titan, 28 amu ions were observed to escape along its induced magnetic tail by the Voyager 1 Plasma Science Instrument (PLS). In analogy with Venus, the escaping ions were thought to originate in the ionosphere. The Cassini mission permits a test of this principle due to the numerous flybys of Titan through both the ionosphere and the tail. A polarization electric field is obtained in the ionosphere of the TA flyby, yielding an upward acceleration of 17 and 28 amu ionospheric ions that is consistent with the flux of heavy ionospheric ions observed escaping along the magnetic tail by the Cassini Ion Mass Spectrometer (CAPS) during the T9 flyby.

Hartle, R. E.↗

A planetary nebula with high oxygen abundance in the galactic bulge

Extensive photoelectric spectra of the planetary nebula H1-55 in the galactic bulge are obtained, and indicate that the object is overabundant in oxygen and nitrogen. Temperature and density are estimated, and chi-square tests are used to place confidence limits on the result. The logarithmic oxygen abundance is found to be 9.50, and the abundance of other heavy elements are also enhanced, such as N = 8.87, S = 7.4, and Ar = 7.4. Helium, sulfur, and argon abundances are affected by uncertainties in the corrections for unobserved ions, which remains consistent with the exceptionally low electron temperature of less than 5600 K. Results agree with the usual models of planetary nebula formation; and therefore, if H1-55 is formed like most planetary nebulae, there must be some very metal-rich stars in the galactic bulge.

Price, C. M.↗

Single-Event Effect Testing of the Analog Devices AD8041ARZ Operational Amplifier

This study was undertaken to determine the single event transient distribution of a transimpedance amplifier configuration of the AD8041 Operational Amplifier. The AD8041 is made in a bipolar technology and the application of interest has a bipolar supply of ±5 V. The device was monitored for transient events on the output voltage during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory’s (LBNL) 88-inch Cyclotron.

Matthew B. Joplin↗