At least 271 records · Page 15

Nature-Inspired Motivation for Developing Self-Healable Electrical Insulation

Polymeric aircraft electrical insulation normally degrade by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Self-healing insulation may be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the material. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, self-healing through establishment of ionic crosslinks allows for multiple healing events to occur as well as achieving full recovery strength under certain thermal environments. Surlyn®, a commercial ionically-crosslinked material, was investigated as a self-healing insulation candidate based on prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was studied to determine if moisture absorption rates in Surlyn® were lower than that of common polyimide insulators. Preliminary data showed that when cut, Surlyn® films lost nearly 60 percent of its original dielectric strength. However, when Surlyn® was cut and subsequently annealed, the films not only re-mended, but also recouped approximately 93 percent of its original dielectric strength, along with 90-97 percent of its mechanical strength.

electrical↗

Self-Repairing Polymer-Modified Cements for High Temperature Geothermal and Fossil Energy Applications

In this work five novel polymer-cement composite formulations were prepared and evaluated as potential cementitious material alternatives to conventional wellbore cement. These cement composites were cured at 200 °C and their mechanical properties, including compressive strength, Young modulus, shear bond strength to steel casing, and self-healing and re-adhering (to steel) capability. Thermal stability was also evaluated by curing these cement materials at 200 °C for up to one month followed by determining their mineralogy and chemical composition by X-ray diffraction spectroscopy, 13C NMR, and total organic carbon. Permeability analysis was performed before and after healing a longitudinal fracture on unmodified cements and polymer-cement composites with the later showing lower (2nd/1st) permeability ratios with respect to base cements. Furthermore, a reduction in permeability of up to 80X on average with respect to their unmodified (base) cement, was observed in two polymer-cement formulations suggesting that the introduction of these polymers bring about self-healing capability. Two of the best performing polymer-cement composites were exposed to 30-day curing period at 200 °C showing that their self-healing capability is maintained. The composite stability is associated to the fact that the polymer material is stable as demonstrated by total organic carbon and NMR spectroscopy. These advanced polymer-cement composites with higher ductility and self-healing capability could be used as alternative wellbore cement materials for geothermal and fossil energy applications.

Rod, Kenton A.↗

Frictional and Lithological Controls on Shallow Slow Slip at the Northern Hikurangi Margin

Slow slip events (SSEs) have been identified at subduction zones globally as an important link in the continuum between elastodynamic ruptures and stable creep. The northern Hikurangi margin is home to shallow SSEs which propagate to within 2 km of the seafloor and possibly to the trench, providing insights into the physical conditions conducive to SSE behavior. We report on a suite of friction experiments performed on protolith material entering the SSE source region at the Hikurangi margin, collected during the International Ocean Discovery Program Expedition 375. We performed velocity stepping and slide-hold-slide experiments over a range of fault slip rates, from plate rate (5 cm/yr or 1.6 × 10 –9 m/s) to ~1 mm/s (10 –3 m/s) and quantified the frictional velocity dependence and healing rates for a range of lithologies atdifferent stresses. The frictional velocity dependence (a-b) and critical slip distance DC increase with fault slip rate in our experiments. We observe atransition from velocity weakening to strengthening at slip rates of ~0.3 µm/s. This velocity dependence of DC could be due to a combination of dilatant strengthening and a widening of the active shear zone at higher slip rates. We document low healing rates in the clay-rich volcaniclastic conglomerates, which lie above the incoming plate basement at least locally, and relatively higher healing rates in the chalk lithology. Finally, our experimental constraints on healing rates in different input lithologies extrapolated to timescales of 1–10 years are consistent with the geodetically inferred low stress drops and healing rates characteristic of the Hikurangi SSEs.

58 GEOSCIENCES↗

Fluid‐Driven Cohesive Strengthening: Critical Role of Reaction Kinetics as the Determinant for Frictional Stability

After an earthquake, faults in the Earth's crust lock up and slowly regain strength. This process, called fault healing, plays a key role in determining how often earthquakes happen and how large they can be. While scientists know that healing involves both mechanical friction and chemical changes in rocks, it has been unclear how these processes work together, especially over shorter timescales in laboratory settings. In our study, we ran controlled experiments on the mineral anhydrite under different fluid conditions. We found that the presence and pressure of water speeds up fault healing by triggering a chemical reaction that strengthens the fault over time. This strengthening makes the fault more resistant to sliding, which could delay future earthquakes—but also sets the stage for larger ones when they do occur. We propose a model that combines frictional and chemical processes to explain this water‐activated, time‐dependent healing. Importantly, our results show that even faults typically considered stable could still produce earthquakes if they undergo sufficient chemical healing. This has broad implications for understanding where and when earthquakes might strike, especially in fluid‐rich environments such as subduction zones and geoenergy settings.

Affinito, R [Pennsylvania State Univ., University ↗

Epoxy-based vitrimeric semi-interpenetrating network/MXene nanocomposites for hydrogen gas barrier applications

Herein, we report MXene-filled epoxy-based vitrimeric nanocomposites featuring a semi-interpenetrating network (S-IPN) to develop a hydrogen gas (H 2 ) barrier coating with self-healing characteristics for compressed H 2 storage applications. The reversible epoxy network was formed by synthesizing linear epoxy chains with pendent bis-hydroxyl groups using amino diol, which were then crosslinked with 1,4-benzenediboronic acid to generate dynamic boronic ester linkages. To achieve the S-IPN-type molecular arrangement, the epoxy chains were in situ crosslinked in the presence of poly(ethylene-co-vinyl alcohol) (EVOH), giving rise to a self-healing network (EEP) with a healing efficiency of 87%. Into the S-IPN vitrimer (EEP), a 2D platelet-type nanofiller MXene was incorporated to introduce a tortuous path for H 2 gas diffusion along with improved mechanical properties. The nanocomposite coating was applied to nylon 6 liner material, which is conventionally used in all-composite H 2 storage vessels. Further, the application of a 2 wt% MXene/EEP nanocomposite coating showed a permeability coefficient of 0.062 cm 3 mm m -2 d -1 atm -1 exhibiting ~96% reduction in gas permeability compared to uncoated nylon 6. The same nanocomposite exhibited a healing efficiency of 79%. Increasing the MXene loading to 10 wt% further reduced the permeability coefficient to 0.002 cm 3 mm m -2 d -1 atm -1 ; however, the healing efficiency decreased due to restricted chain mobility. In essence, the current work highlights the potential of vitrimeric S-IPN nanocomposite coatings for H 2 gas-barrier applications, enhancing safety and performance.

42 ENGINEERING↗

Non-disruptive error field measurement in DIII-D low safety factor plasmas and projection to ITER

Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional 'compass scan'. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Environmentally Friendly Coating Technology for Autonomous Corrosion Control

This work concerns the development of environmentally friendly encapsulation technology, specifically designed to incorporate corrosion indicators, inhibitors, and self-healing agents into a coating, in such a way that the delivery of the indicators and inhibitors is triggered by the corrosion process, and the delivery of self-healing agents is triggered by mechanical damage to the coating. Encapsulation of the active corrosion control ingredients allows the incorporation of desired autonomous corrosion control functions such as: early corrosion detection, hidden corrosion detection, corrosion inhibition, and self-healing of mechanical damage into a coating. The technology offers the versatility needed to include one or several corrosion control functions into the same coating.The development of the encapsulation technology has progressed from the initial proof-of-concept work, in which a corrosion indicator was encapsulated into an oil-core (hydrophobic) microcapsule and shown to be delivered autonomously, under simulated corrosion conditions, to a sophisticated portfolio of micro carriers (organic, inorganic, and hybrid) that can be used to deliver a wide range of active corrosion ingredients at a rate that can be adjusted to offer immediate as well as long-term corrosion control. The micro carriers have been incorporated into different coating formulas to test and optimize the autonomous corrosion detection, inhibition, and self-healing functions of the coatings. This paper provides an overview of progress made to date and highlights recent technical developments, such as improved corrosion detection sensitivity, inhibitor test results in various types of coatings, and highly effective self-healing coatings based on green chemistry.

Coatings↗

Engineering Polymer Blends for Impact Damage Mitigation

Structures containing polymers such as DuPont's Surlyn® 8940, demonstrate puncture healing when impacted by a 9 millimeter projectile traveling from speeds near 300 meters per second (1,100 feet per second) to hypervelocity impacts in the micrometeoroid velocity range of 5 kilometers per second (16,000 feet per second). Surlyn® 8940 puncture heals over a temperature range of minus 30 degrees Centigrade to plus 70 degrees Centigrade and shows potential for use in pressurized vessels subject to impact damage. However, such polymers are difficult to process and limited in applicability due to their low thermal stability, poor chemical resistance and overall poor mechanical properties. In this work, several puncture healing engineered melt formulations were developed. Moldings of melt blend formulations were impacted with a 5.56 millimeter projectile with a nominal velocity of 945 meters per second (3,100 feet per second) at about 25 degrees Centigrade, 50 degrees Centigrade and 100 degrees Centigrade, depending upon the specific blend being investigated. Self-healing tendencies were determined using surface vacuum pressure tests and tensile tests after penetration using tensile dog-bone specimens (ASTM D 638-10). For the characterization of tensile properties both pristine and impacted specimens were tested to obtain tensile modulus, yield stress and tensile strength, where possible. Experimental results demonstrate a range of new puncture healing blends which mitigate damage in the ballistic velocity regime.

Gordon, Keith L.↗

Self-Healable Electrical Insulation for High Voltage Applications

Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

electrical insulation↗

Zinc chloride affects chondrogenesis via VEGF signaling

Highlights: • ZnCl2 increases expression of various chondrogenic signaling intermediates. • VEGF/VEGFR play a key role in modulating levels of chondrogenesis. • Insulin mimetics are an appealing option for improvement of fracture healing. • Axitinib + ZnCl2 treatment results in decreased transcription of chondrogenic genes. Insulin mimetics, including zinc containing compounds, have previously been shown to influence chondrogenesis as it relates to healing of fractures in various preclinical models. However, the mechanism by which these compounds drive chondrogenic differentiation is yet undefined. Here, via next-generation sequencing (NGS) and in vitro functional validation, we show that Zinc Chloride (ZnCl{sub 2}) induces expression of both chondrogenic genes (Sox9, Runx1, collagen) as well as genes associated with VEGF-mediated signal transduction, including VEGF receptors 1 and 2 and their ligands; VEGF-A and VEGF-B. Noticeably, although insulin was able to also induce expression of these pro-angiogenic and pro-chondrogenic genes, the impact of insulin on expression of VEGF receptor and ligand genes was marginal when compared to that of ZnCl{sub 2.} Furthermore, while the VEGFR antagonist, Axitinib, was able to attenuate the pro-chondrogenic effects of both insulin and ZnCl{sub 2}; a reduction in gene and protein expression was most profoundly observed when the antagonist was applied to cells treated with ZnCl{sub 2.} Taken together, these data suggest an important role for the VEGF-mediated signal transduction pathways in the positive effects observed when applying zinc-based compounds as adjuvants for chondrogenesis-mediated fracture healing. In this regard, further mechanistic evaluation of ZnCl{sub 2} and other zinc-containing insulin mimetics may support rational design of therapies targeted for disease indications associated with impaired fracture healing.

60 APPLIED LIFE SCIENCES↗

Beyond Melting: Amorphous Bonding for Joining and Consolidation

Crystallization may be the hidden constraint in thermoplastic composite manufacturing. It requires tightly controlled cooling, induces residual stresses through shrinkage, and introduces path-dependent behavior that complicates predictive modeling yet remains essential for structural performance. This work asks: can bonding be achieved without relying on melt-driven crystallization? To address this, thin (5–20 μm) polyetherimide (PEI) interlayers are pre-healed to slow-cooled polyaryletherketone (PAEK) in two contexts. The first, Thermabond®, is sub-melt joining of low melt-PAEK laminates. Results show that bond quality is governed primarily by processing (i.e., adequate healing and film handling) rather than modest changes in interlayer thickness. This concept is then extended to laminate-scale manufacturing through an architecture known as OATMEAL (Out-of-autoclave Amorphous/semicrystalline Thermoplastic Material for Energy-efficient Aerospace-grade Laminates). PEI is healed to carbon fiber reinforced polyetheretherketone (PEEK) at the prepreg and excess PEI is then ablated from the surface. Crystallinity is developed off-line during prepreg fabrication, while subsequent consolidation occurs below the melt temperature to preserve it. Cross-ply warpage experiments show that, contrary to intuition, repeated amorphous interfaces reduce global curvature by lowering the effective stress lock-in temperature and eliminating crystallization shrinkage from the lamina response. Correspondingly, laminate behavior is accurately predicted using classical laminate theory (CLT) with a single effective stress-free temperature, whereas conventional CF/PEEK requires accounting for crystallization-driven effects. By decoupling interfacial healing from crystallization, OATMEAL enables sub-melt consolidation, reduces energy consumption by up to 75%, and increases manufacturing throughput by fivefold. These results demonstrate that amorphous bonding is not only a joining strategy, but a pathway to more predictable and scalable thermoplastic composite manufacturing.

solidification↗

Shallow Soil Response to a Buried Chemical Explosion With Geophones and Distributed Acoustic Sensing

Abstract Shallow sediments can respond non‐linearly to large dynamic strains and undergo a subsequent healing phase as the material gradually recovers following the passing of seismic waves. This study focuses on the physical changes in the subsurface caused by the shaking from a buried chemical explosion detonated in a borehole in Nevada, USA, as a part of the Source Physics Experiment Phase II. The explosion damaged the shallow subsurface and modified the frequency content recorded by 491 geophones and 2240 Distributed Acoustic Sensing (DAS) channels within 2.5 km from surface ground zero. We observe a gradual shift of resonance frequencies in the 10–25 Hz frequency band in the hours following the explosion and develop a method to characterize the related logarithm‐type healing process of the shallow (i.e., upper ∼25 m) subsurface. We find that stronger levels of ground motion increase the relative degree of damage and duration of the subsurface healing; with the spall region exhibiting the largest degree of damage and longest healing recovery time. We observe coherent spatial patterns of damage with the region located to the southeast of the explosion exhibiting more damage than the southwest region. This study demonstrates that both DAS and co‐located geophones capture similar temporal changes associated with the physical processes occurring in the subsurface, with the high‐density sampling of DAS measurements enabling a new capability to monitor the fine‐scale changes of the Earth's shallow subsurface following the detonation of a buried explosion.

Viens, Loïc↗

Microcracks, micropores, and their petrologic interpretation for 72415 and 15418

Lunar samples 72415 and 15418 have complex microstructures that indicate a series of fracturing and healing events. Both samples contain relatively few open microcracks but many sealed and healed microcracks. Dunite 72415 contains abundant healed cracks that formed tectonically, symplectic intergrowths spatially and probably genetically related to microcracks, and a cataclastic matrix that has been extensively sintered. Metamorphosed breccia 15418 contains many post-metamorphic healed cracks, large shock induced cracks that have been sealed with glass, and a few younger, thin, open shock induced cracks.

Richter, D.↗

A Multifunctional Coating for Autonomous Corrosion Control

Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of existing microcapsulation designs, the corrosion controlled release function that triggers the delivery of corrosion indicators and inhibitors on demand, only when and where needed. Microencapsulation of self-healing agents for autonomous repair of mechanical damage to the coating is also being pursued. Corrosion indicators, corrosion inhibitors, as well as self-healing agents, have been encapsulated and dispersed into several paint systems to test the corrosion detection, inhibition, and self-healing properties of the coating. Key words: Corrosion, coating, autonomous corrosion control, corrosion indication, corrosion inhibition, self-healing coating, smart coating, multifunctional coating, microencapsulation.

Calle, Luz M.↗

Next Generation Wiring

Wiring is a major operational component on aerospace hardware that accounts for substantial weight and volumetric space. Over time wire insulation can age and fail, often leading to catastrophic events such as system failure or fire. The next generation of wiring must be reliable and sustainable over long periods of time. These features will be achieved by the development of a wire insulation capable of autonomous self-healing that mitigates failure before it reaches a catastrophic level. In order to develop a self-healing insulation material, three steps must occur. First, methods of bonding similar materials must be developed that are capable of being initiated autonomously. This process will lead to the development of a manual repair system for polyimide wire insulation. Second, ways to initiate these bonding methods that lead to materials that are similar to the primary insulation must be developed. Finally, steps one and two must be integrated to produce a material that has no residues from the process that degrades the insulating properties of the final repaired insulation. The self-healing technology, teamed with the ability to identify and locate damage, will greatly improve reliability and safety of electrical wiring of critical systems. This paper will address these topics, discuss the results of preliminary testing, and remaining development issues related to self-healing wire insulation.

Medelius, Petro↗

Mitigation of Crack Damage in Metallic Materials

A system designed to mitigate or heal crack damage in metallic materials has been developed where the protected material or component is coated with a low-melting temperature film. After a crack is formed, the material is heated, melting the film which then infiltrates the crack opening through capillary action. Upon solidification, the healing material inhibits further crack damage in two ways. While the crack healing material is intact, it acts like an adhesive that bonds or bridges the crack faces together. After fatigue loading damages, the healing material in the crack mouth inhibits further crack growth by creating artificially-high crack closure levels. Mechanical test data show that this method sucessfully arrests or retards crack growth in laboratory specimens.

Leser, Patrick E.↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗

Autonomous Strategies for Improved Performance and Reliability of Li‐Ion Batteries

Abstract The battery community has devoted significant effort to improve the performance and reliability of Li‐ion batteries through the development of new materials. The integration of autonomous function provides an alternative strategy to further extend performance. Autonomous material systems mimic the ability of biological systems to self‐protect, sense, regulate, and heal in response to damage and other environmental changes. When incorporated in batteries, these materials enable autonomic restoration of battery performance upon degradation, as well as autonomic shutdown or extinguishment in response to thermal runaway. Successful strategies for improving Li‐ion battery performance include controlled release of microencapsulated functional additives and the integration of self‐healing or adaptive interlayers and binders. These methods have been effective for stabilizing the solid electrolyte interface, preventing battery fires, restoring electrode conductivity, and suppressing Li dendrite growth. Challenges and opportunities exist in the further application of autonomous strategies in the battery environment. A greater variety of encapsulated additives with precise triggered‐release are needed to address specific battery degradation mechanisms. Incorporation of self‐healing polymers in solid‐state batteries facilitates improvement in interfacial and mechanical stability. The integration of autonomous strategies with battery management systems potentially enables enhanced control over multiple battery cycling parameters.

Zhao, Lihong↗