Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics

A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA's Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were ≥ 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.

Ion Thruster↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics

A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA’s Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were ≥ 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.

George C. Soulas↗

Hourglass control in staggered-grid hydrodynamics using virtual element stabilization techniques

Numerical simulations using the staggered-grid hydrodynamics (SGH) discretization suffer from hourglass instabilities. In this work, we develop a stabilization method to suppress the hourglass instabilities using techniques from the virtual element method (VEM). The stiffness matrix of the VEM consists of two terms: the consistency matrix which is rank deficient and the stability matrix. Here, we first show that in two dimensions and on general polygons, the stiffness matrix of the SGH is identical to the consistency matrix of the linear VEM for both the diffusion equation and the linear elasticity equation. These analyses explain the origin of the hourglass instabilities of the SGH discretization method, and establish a theoretical foundation for our proposed stabilization method by augmenting the stiffness matrix of the SGH discretization using the VEM stability matrix. Then, we present numerical examples using Lagrangian SGH simulations. The numerical experiments demonstrate that the proposed VEM stabilization method is effective at eliminating hourglass modes in the SGH discretization.

97 MATHEMATICS AND COMPUTING↗

Smart Inverter Stability Enhancement in Weak Grids Using Adaptive Virtual-Inductance

An adaptive virtual-inductance feedforward scheme is presented in this article to enhance the stable operation of smart inverters in weak grids. In the developed scheme, the virtual inductance is updated in real time according to an adaptation law to ensure that the inverter follows the dynamic response of a robust reference model, thereby ensuring stability without the need for any grid impedance estimation. In this article, the developed scheme is validated with experimental results obtained from testing a small-scale two-level, 208-V, 2-kW inverter.

42 ENGINEERING↗

Boundary-Layer Stability Analysis of the Mean Flows Obtained Using Unstructured Grids

Boundary-layer stability analyses of mean flows extracted from unstructured-grid Navier- Stokes solutions have been performed. A procedure has been developed to extract mean flow profiles from the FUN3D unstructured-grid solutions. Extensive code-to-code validations have been performed by comparing the extracted mean ows as well as the corresponding stability characteristics to the predictions based on structured-grid solutions. Comparisons are made on a range of problems from a simple at plate to a full aircraft configuration-a modified Gulfstream-III with a natural laminar flow glove. The future aim of the project is to extend the adjoint-based design capability in FUN3D to include natural laminar flow and laminar flow control by integrating it with boundary-layer stability analysis codes, such as LASTRAC.

Liao, Wei↗

Modeling of Grid-Forming Inverters for Transient Stability Simulations of an all Inverter-based Distribution System

Existing models of grid-forming inverters are typically three-phase electromagnetic models and positive sequence electromechanical models. Both of them are not suitable for dynamic simulations of large scale three-phase unbalanced distribution systems. In order to investigate grid-forming inverters’ impact on the transient stability of large scale three-phase unbalanced distribution systems, a dynamic model of a grid-forming inverter is developed and implemented in an open-source GridLAB-D simulation environment. The advantage of this method is that it can be extended to full-size three-phase unbalanced distribution systems. Simulation results of an all grid-forming inverter-based modified version of IEEE 123-node distribution system verify the capability of grid-forming inverters to maintain the transient stability of a resilient distribution system.

Grid-forming, Inverter, Distribution System, Trans↗

Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Fourth Edition

As the world increasingly seeks low-carbon energy solutions, solar power emerges as the most abundant resource on our planet. However, the challenge of effectively harnessing this energy is crucial in the coming years. Solar energy applications such as photovoltaics, solar heating and cooling, and concentrating solar power use different technologies to capitalize on sunlight. Each system has unique capabilities and requirements, underscoring the need for reliable information about solar resources across diverse installations, from residential rooftops to large-scale power plants. This is especially important for substantial projects, often exceeding $1 billion in construction costs. Before embarking on such ventures, it is imperative to obtain accurate data concerning solar resource quality and reliability at specific sites. Developers require detailed historical information, including seasonal, daily, hourly, and, ideally, subhourly variability to effectively predict a power plant's annual performance. Without these vital data, financial analyses fall short. Moreover, with the growing adoption of distributed photovoltaics, integrating these generation sources becomes critical to maintaining grid reliability and stability. By accurately forecasting generation patterns, utilities and system operators can facilitate greater integration of solar energy, thus ensuring the operational stability of the grid. The complexity and importance of these issues have prompted the foremost experts in the field to collaborate under the auspices of the International Energy Agency's (IEA's) Photovoltaic Power Systems Programme (PVPS) Task 16 to publish this handbook, which summarizes state-of-the-art information about all these topics. The efforts focus on providing reliable data and insights that can help shape our investments in solar energy and drive a sustainable future.

14 SOLAR ENERGY↗

A solution adaptive grid procedure for an upwind parabolized flow solver

A solution adaptive grid procedure based on an error equi-distribution scheme is developed and applied to a Parabolized Navier-Stokes solver. An improved method for selecting weighting functions is introduced which involves normalizing a combination of flowfield gradients and curvature of a number of dependent variables and then selecting the largest at each point. The scheme re-distributes grid points line-by-line, with grid point motion controlled by forces analogous to tensional and torsional spring forces with the spring constants set equal to the weighting functions. Torsional terms are functions of the grid point positions along neighboring grid lines and provide grid smoothness and stability. A grid-fitting scheme is introduced for external flows in which the number of grid points in the freestream are reduced to a minimum. Results for several problems are presented to demonstrate the improvements obtainable with the solution adaptive grid procedure.

Harvey, Albert D.↗

IEEE PES GM Poster - Cyber-Informed Engineering Approach to Mitigating BESS Supply Chain Concerns

Battery energy storage systems (BESS) are increasingly important to meet the needs of grid resilience and reliability. BESS provide critical grid services, maintaining stability of the grid with increased variable conditions. However, there are significant geopolitical and security concerns regarding their operation in critical infrastructure, due to lack of a domestic supply chain and prevalence of foreign entity of concern (FEOC) components in BESS and associated inverter-based resources. The supply chain challenge is dually exacerbated by a lack of alternative suppliers who can meet the economic targets for energy delivery and a potentially adversarial supply chain. Solutions are needed to secure components, addressing mixed layers of risk and engineering controls. This paper presents a specific application of Cyber-Informed Engineering (CIE) principles for BESS and recommends an alternative strategy to blocking the supply chain, ensuring that grid modernization targets can be met despite lack of a validated or secure supply chain. This study focuses on the United State (U.S.) use case, but the process can be applied globally to address supply chain security challenges. CIE practices represent the next step in functional assurance and risk mitigation, ensuring optimal resource allocation and enhancing security measures to safeguard the future of energy in the U.S. and beyond.

25 - ENERGY STORAGE↗

Dynamic Earth Energy Storage: Terawatt-Year, Grid-Scale Energy Storage using Planet Earth as a Thermal Battery (GeoTES): Seedling Project Final Report

Grid-scale energy storage has been identified as a needed technology to support the continued build-out of intermittent renewable energy resources. As of April 2017, the U.S. had approximately 24.2 GW of energy storage on line, compared to 1,081 GW of installed generation capacity (Litynski et al. 2006, Hellstrom 2003). This represents a large shortfall of the storage needed to stabilize the U.S. grids with the rising penetration of renewable energy. Our team proposed to address this shortfall through the storage of excess energy as geothermal brine in deep geologic formations. This concept, known as geologic thermal energy storage (GeoTES), relies on the storage of thermal energy in geologic formations for recovery and use in large-scale direct use geothermal applications. As such, GeoTES has the potential to play a significant role in meeting the energy storage shortfall in the coming decades by assisting with peak demand ramping, easing stress on transmission, providing regional storage to support sustainable direct use geothermal applications, and providing a variety of grid stabilization benefits due to renewable outages or inaccurate forecasting and rotor stability.

15 GEOTHERMAL ENERGY↗