At least 271 records · Page 15

Collaborative Research: Continuous Dynamic Grid Adaptation in a Global Atmospheric Model - Application and Refinement

This project had goals of advancing the performance capabilities of the numerical general circulation model EULAG and using it to produce a fully operational atmospheric global climate model (AGCM) that can employ either static or dynamic grid stretching for targeted phenomena. The resulting AGCM combined EULAG's advanced dynamics core with the "physics" of the NCAR Community Atmospheric Model (CAM). Effort discussed below shows how we improved model performance and tested both EULAG and the coupled CAM-EULAG in several ways to demonstrate the grid stretching and ability to simulate very well a wide range of scales, that is, multi-scale capability. We leveraged our effort through interaction with an international EULAG community that has collectively developed new features and applications of EULAG, which we exploited for our own work summarized here. Overall, the work contributed to over 40 peer-reviewed publications and over 70 conference/workshop/seminar presentations, many of them invited. 3a. EULAG Advances EULAG is a non-hydrostatic, parallel computational model for all-scale geophysical flows. EULAG's name derives from its two computational options: EULerian (flux form) or semi-LAGrangian (advective form). The model combines nonoscillatory forward-in-time (NFT) numerical algorithms with a robust elliptic Krylov solver. A signature feature of EULAG is that it is formulated in generalized time-dependent curvilinear coordinates. In particular, this enables grid adaptivity. In total, these features give EULAG novel advantages over many existing dynamical cores. For EULAG itself, numerical advances included refining boundary conditions and filters for optimizing model performance in polar regions. We also added flexibility to the model's underlying formulation, allowing it to work with the pseudo-compressible equation set of Durran in addition to EULAG's standard anelastic formulation. Work in collaboration with others also extended the demonstrated range of validity of soundproof models, showing that they are more broadly applicable than some had previously thought. Substantial testing of EULAG included application and extension of the Jablonowski-Williamson baroclinic wave test - an archetype of planetary weather - and further analysis of multi-scale interactions arising from collapse of temperature fronts in both the baroclinic wave test and simulations of the Held-Suarez idealized climate. These analyses revealed properties of atmospheric gravity waves not seen in previous work and further demonstrated the ability of EULAG to simulate realistic behavior over several orders of magnitude of length scales. Additional collaborative work enhanced capability for modeling atmospheric flows with adaptive moving meshes and demonstrated the ability of EULAG to move into petascale computing. 3b. CAM-EULAG Advances We have developed CAM-EULAG in collaboration with former project postdoc, now University of Cape Town Assistant Professor, Babatunde Abiodun. Initial study documented good model performance in aqua-planet simulations. In particular, we showed that the grid adaptivity (stretching) implemented in CAM-EULAG allows higher resolution in selected regions without causing anomalous behavior such as spurious wave reflection. We then used the stretched-grid version to analyze simulated extreme precipitation events in West Africa, comparing the precipitation and event environment with observed behavior. The model simulates fairly well the spatial scale and the interannual and intraseasonal variability of the extreme events, although its extreme precipitation intensity is weaker than observed. In addition, both observations and the simulations show possible forcing of extreme events by African easterly waves. 3c. Other Contributions Through our collaborations, we have made contributions to a wide range of outcomes. For research focused on terrestrial behavior, these have included (1) upwind schemes for gas dynamics, (2) a nonlinear perspective on the dynamics of the Madden-Julian Oscillation, (3) numerical realism of thermal convection, (4) extreme precipitation processes, (5) unstructured meshes, (6) porous-media analogies for simulating flow in urban environments, (7) Monge-Ampere enhancements of semi-Lagrangian methods and (8) further extensions of the generality of EULAG applications to geophysical problems. The generality of EULAG for multi-scale flow was also demonstrated through solar applications. Simulations of solar magnetohydrodynamics showed that EULAG produces the solar cycle fairly well. Although the model's solar cycle is significantly longer than observed, it shows remarkable agreement with observations in features of spatial evolution. These efforts in environments that are extreme from a geophysical perspective have helped to establish the robustness of EULAG as an all-scale code for geophysical applications.

54 ENVIRONMENTAL SCIENCES↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

Algorithm and code development for unsteady three-dimensional Navier-Stokes equations

In the last two decades, there have been extensive developments in computational aerodynamics, which constitutes a major part of the general area of computational fluid dynamics. Such developments are essential to advance the understanding of the physics of complex flows, to complement expensive wind-tunnel tests, and to reduce the overall design cost of an aircraft, particularly in the area of aeroelasticity. Aeroelasticity plays an important role in the design and development of aircraft, particularly modern aircraft, which tend to be more flexible. Several phenomena that can be dangerous and limit the performance of an aircraft occur because of the interaction of the flow with flexible components. For example, an aircraft with highly swept wings may experience vortex-induced aeroelastic oscillations. Also, undesirable aeroelastic phenomena due to the presence and movement of shock waves occur in the transonic range. Aeroelastically critical phenomena, such as a low transonic flutter speed, have been known to occur through limited wind-tunnel tests and flight tests. Aeroelastic tests require extensive cost and risk. An aeroelastic wind-tunnel experiment is an order of magnitude more expensive than a parallel experiment involving only aerodynamics. By complementing the wind-tunnel experiments with numerical simulations the overall cost of the development of aircraft can be considerably reduced. In order to accurately compute aeroelastic phenomenon it is necessary to solve the unsteady Euler/Navier-Stokes equations simultaneously with the structural equations of motion. These equations accurately describe the flow phenomena for aeroelastic applications. At Ames a code, ENSAERO, is being developed for computing the unsteady aerodynamics and aeroelasticity of aircraft and it solves the Euler/Navier-Stokes equations. The purpose of this contract is to continue the algorithm enhancements of ENSAERO and to apply the code to complicated geometries. During the last year, the geometric capability of the code was extended to simulate transonic flows, a wing with oscillating control surface. Single-grid and zonal approaches were tested. For the zonal approach, a new interpolation technique was introduced. The key development of the algorithm was an interface treatment between moving zones for a control surface using the virtual-zone concept. The work performed during the period, 1 Apr. 1992 through 31 Mar. 1993 is summarized. Additional details on the various aspects of the study are given in the Appendices.

Obayashi, Shigeru↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A nested grid, nonhydrostatic, elastic model using a terrain-following coordinate transformation - The radiative-nesting boundary conditions

This study presents a nested-grid nonhydrostatic and elastic model using a terrain-following coordinate transformation as well as a unique application of grid-nesting techniques to the time-splitting elastic model. A simulation of the 10-m-high Witch of Agnesi Mountain provides the control to test this new model. The results show that the model produces the same solution as that derived from a simple linear analytic model. It is demonstrated that the new nested-grid model improves model resolution without resorting to the costly method of placing a fine-resolution grid over the entire domain. Since the wave reflection from the boundaries of the fine-grid model is well controlled, the boundary of the nested fine-grid model can be located even at the wave-active region. The model can be used to simulate various weather systems in which scale interactions are important.

Chen, Chaing↗

Grid-to-rod fretting wear study of SiC/SiC composite accident-tolerant fuel claddings using an autoclave fretting bench test

Grid-to-rod-fretting (GTRF) in pressurized water reactors (PWRs) is known to cause wear and surface damage on the fuel claddings, potentially leading to radioactive leakage. One of the accident-tolerant fuel (ATF) concepts is to use advanced cladding materials that could withstand higher temperatures. Here, we investigated the wear behavior of candidate silicon carbide (SiC)-based composite claddings with different levels of surface finish in fretting against a commercial ZIRLO alloy grid using a unique bench-scale autoclave GTRF rig. The experiments mimicked the environment in an industrial full-assembly PWR simulator. Fretting tests were conducted with a realistic load (~0.5 N) in deionized water under a pressure of 20–23 bar at 204 °C for 100 h. While the SiC/SiC composite claddings showed significantly higher wear resistance than the commercial ZIRLO alloy cladding as expected, the smoother versions experienced surprisingly higher wear than the much softer counterface, ZIRLO grid. The wear mechanism of the SiC/SiC cladding was attributed to the SiC wear debris that was trapped at the fretting interface causing both 3-body and 2-body (embedded into the grid surface) abrasion of the cladding. Rougher SiC/SiC claddings had less material loss but caused more wear on the ZIRLO grid. Finally, pre-oxidized ZIRLO grid showed better compatibility with the SiC/SiC cladding to protect both the cladding and grid as a result of reduced wear debris trapping.

36 MATERIALS SCIENCE↗

An Advanced Platform for Development and Evaluation of Photovoltaic Inverters Using Hardware-in-the-Loop

A rapid shift in the world's energy paradigm towards a higher proliferation of renewables is underway. As these new resources are interconnected with the EPS, it is essential that they not only comply with the relevant interconnection standards, but that they also are evaluated under various dynamic resource input and grid conditions to ensure that they will properly participate in the advancedEPS architecture. To this end, NREL leveraged controller hardware-in-the-loop (CHIL) and power hardware-in-the-lopp (PHIL) simulation techniques to create an advanced platform for the development and evaluation of photovoltaic (PV) inverters. This paper describes a CHIL-based methodology by which PV inverter controllers can be tested against simulated inverter hardware before prior to at powertesting, a PHIL-based PV simulator that can be used to test a PV inverter's response to the truly dynamic output of a PV array, and a grid interconnection evaluator that leverages PHIL techniques to automate the execution and analysis of key interconnection standard test procedures. A number of demonstration test results are presented. These capabilities make up a novel platform that will helpdevelop the PV inverters that will support the next generation EPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

USM3D-ME Analyses Performed in Support of a Wind Tunnel Test of a Boundary-Layer Ingestion Configuration

Boundary Layer Ingestion (BLI) has been proposed as a technology with the potential to decrease fuel burn. However, one major concern for BLI configurations is the potential degradation of the flow quality, both on the airframe and at the fan face, resulting from the tightly integrated propulsor. A wind tunnel test was performed in the National Transonic Facility (NTF) at the NASA Langley Research Center to investigate the flow quality ingested by a tail cone thruster configuration, similar to the Single Aisle Turboelectric Aircraft Concept with Aft Boundary Layer Ingestion (STARC-ABL). The wind tunnel model was a modified version of the Common Research Model (CRM) to include an aft-mounted, flow-through propulsor. The experimental data obtained from the wind tunnel test provide insight into the flow and enables an assessment of the accuracy of the USM3D-ME flow solver for predicting the flow at the fan face, which will be crucial for fan design purposes. Both grid refinement and turbulence model studies were performed for the Clean and Cruise MFP configurations at the condition corresponding to ReMAC = 5 million, Mach = 0.8, and alpha = 2 deg. The selected grid refinement level and turbulence model were then used to perform simulations over the range of conditions considered in the NTF wind tunnel test. The condition sweep comparisons illustrate favorable agreement with the experimental data over the entire range of conditions and for all Mass Flow Plug (MFP) configurations. The largest differences were observed for the Idle MFP configuration, with approximately 3% difference observed between USM3D-ME and the experimental data. Future work should investigate the impact of higher fidelity turbulence models and grid adaptation on the USM3D-ME predictions.

CRM↗

USM3D-ME Analyses Performed in Support of a Wind Tunnel Test of a Boundary-Layer Ingestion Configuration

Boundary Layer Ingestion (BLI) has been proposed as a technology with the potential to decrease fuel burn. However, one major concern for BLI configurations is the potential degradation of the flow quality, both on the airframe and at the fan face, resulting from the tightly integrated propulsor. A wind tunnel test was performed in the National Transonic Facility (NTF) at the NASA Langley Research Center to investigate the flow quality ingested by a tail cone thruster configuration, similar to the Single Aisle Turboelectric Aircraft Concept with Aft Boundary Layer Ingestion (STARC-ABL). The wind tunnel model was a modified version of the Common Research Model (CRM) to include an aft-mounted, flow-through propulsor. The experimental data obtained from the wind tunnel test provide insight into the flow and enables an assessment of the accuracy of the USM3D-ME flow solver for predicting the flow at the fan face, which will be crucial for fan design purposes. Both grid refinement and turbulence model studies were performed for the Clean and Cruise MFP configurations at the condition corresponding to ReMAC = 5 million, Mach = 0.8, and alpha = 2 deg. The selected grid refinement level and turbulence model were then used to perform simulations over the range of conditions considered in the NTF wind tunnel test. The condition sweep comparisons illustrate favorable agreement with the experimental data over the entire range of conditions and for all Mass Flow Plug (MFP) configurations. The largest differences were observed for the Idle MFP configuration, with approximately 3% difference observed between USM3D-ME and the experimental data. Future work should investigate the impact of higher fidelity turbulence models and grid adaptation on the USM3D-ME predictions.

CRM↗

NREL Smart Grid Projects

Although implementing Smart Grid projects at the distribution level provides many advantages and opportunities for advanced operation and control, a number of significant challenges must be overcome to maintain the high level of safety and reliability that the modern grid must provide. For example, while distributed generation (DG) promises to provide opportunities to increase reliability and efficiency and may provide grid support services such as volt/var control, the presence of DG can impact distribution operation and protection schemes. Additionally, the intermittent nature of many DG energy sources such as photovoltaics (PV) can present a number of challenges to voltage regulation, etc. This presentation provides an overview a number of Smart Grid projects being performed by the National Renewable Energy Laboratory (NREL) along with utility, industry, and academic partners. These projects include modeling and analysis of high penetration PV scenarios (with and without energy storage), development and testing of interconnection and microgrid equipment, as well as the development and implementation of advanced instrumentation and data acquisition used to analyze the impacts of intermittent renewable resources. Additionally, standards development associated with DG interconnection and analysis as well as Smart Grid interoperability will be discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Performance Transmission and Distribution Co-simulation with 10,000+ Inverter-Based Resources

The inverter-based resource (IBR) has become avery important component in the distribution system. The impacts on system transient stability introduced by high IBR penetration are not fully addressed because of the lack of high-fidelity models. The aggregate IBR model at the transmission level cannot precisely reproduce the dynamics of distributed IBR at the distribution system because of the oversimplification. In this paper, we will develop a high-penetration fully-connected transmission and distribution (T&D) co-simulation platform that supports the simulation of 10,000+ dispersed IBR models. The interfacing and iterative initialization techniques for the co-simulation have been implemented to maintain stable operation and simulation of large-multitude of IBR models. The phasor-domain IBR models with grid-forming (GFM) and grid-following (GFL) control are implemented in the distribution systems simulators. The developed platform is tested on high-performance computing (HPC) resources and can be utilized to explore the hierarchical control strategies of IBRs for the large-scale T&D hybrid system.

Liu, Yuan↗

Structure Learning and Statistical Estimation in Distribution Networks - Part II

Limited placement of real-time monitoring devices in the distribution grid, recent trends notwithstanding, has prevented the easy implementation of demand-response and other smart grid applications. Part I of this paper discusses the problem of learning the operational structure of the grid from nodal voltage measurements. In this work (Part II), the learning of the operational radial structure is coupled with the problem of estimating nodal consumption statistics and inferring the line parameters in the grid. Based on a Linear-Coupled(LC) approximation of AC power flows equations, polynomial time algorithms are designed to identify the structure and estimate nodal load characteristics and/or line parameters in the grid using the available nodal voltage measurements. Then the structure learning algorithm is extended to cases with missing data, where available observations are limited to a fraction of the grid nodes. The efficacy of the presented algorithms are demonstrated through simulations on several distribution test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct and large-eddy simulations of three-dimensional compressible Navier-Stokes turbulence

This paper reports results from the numerical implementation and testing of the compressible large eddy-simulation (LES). Relevant quantities from 32-cubed coarse grid LES solutions are compared with results generated from direct numerical simulations (DNS) of three-dimensional compressible turbulence that have been run both with sufficient resolution, at 96 cubed. The 32 cubed LES results overall agree well with their 96 cubed DNS counterparts. Moreover, the new DNS results confirm several recent conclusions about compressible turbulence that have been based primarily on two-dimensional simulations.

Zang, T. A.↗

Blade Displacement Predictions for the Full-Scale UH-60A Airloads Rotor

An unsteady Reynolds-Averaged Navier-Stokes solver for unstructured grids is loosely coupled to a rotorcraft comprehensive code and used to simulate two different test conditions from a wind-tunnel test of a full-scale UH-60A rotor. Performance data and sectional airloads from the simulation are compared with corresponding tunnel data to assess the level of fidelity of the aerodynamic aspects of the simulation. The focus then turns to a comparison of the blade displacements, both rigid (blade root) and elastic. Comparisons of computed root motions are made with data from three independent measurement systems. Finally, comparisons are made between computed elastic bending and elastic twist, and the corresponding measurements obtained from a photogrammetry system. Overall the correlation between computed and measured displacements was good, especially for the root pitch and lag motions and the elastic bending deformation. The correlation of root lead-lag motion and elastic twist deformation was less favorable.

Bledron, Robert T.↗

The impact of forest-controlled snow variability on late-season streamflow varies by climatic region and forest structure

Previous studies have documented how forests influence snow at fine spatial scales, but none have documented the influence that existing forest-snow variability has on streamflow. Here to test how much forest-controlled snow variability influences streamflow, a tiling parameterization based on classifications from high-resolution (1–3 m) vegetation maps was incorporated into the Distributed Hydrology and Soil Vegetation Model (DHSVM). Within each grid cell (90–150 m), the tiling parameterization simulated forest-snow variability with four independently evolving snowpacks. Each tile had unique radiation conditions to represent conditions underneath the canopy, in exposed areas, and along north- and south-facing forest edges. This tiled parameterization was used to test where and when detailed forest-snow modelling should be considered further and where and when the impacts are too small to be worth the effort. To test this, tiled model simulations of streamflow were compared to non-tiled model simulations in the Sierra Nevada, CA, the Jemez Mountains, NM, and the Eastern Cascades, WA. In Tuolumne, CA, the tiled model simulated little difference in grid cell average SWE, and late-season streamflow decreased by only 3%–4% compared to the non-tiled model. In Jemez, NM, the tiled model decreased late-season streamflow by 18% due to increased sublimation. In Chiwawa, WA, the tiled model increased late-season streamflow by 15% due to high shortwave radiation attenuation and less longwave radiation enhancement from the forest. Furthermore, within the Chiwawa, a substantial silvicultural practice was synthetically implemented to increase the north-facing edge's fractional area. This silvicultural experiment, which used the same fractional forest area in all simulations increased late-season streamflow by 35% compared to tiled model simulations that did not represent forest edges. In conclusion, representing forest-SWE variability had an effect on late-season streamflow in some watersheds but not in others based on the fractional area of the forest edges, forest characteristics, and climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments: Preprint

Existing state-of-the-art of single-phase grid-forming (GFM) inverter are primarily focused on electromagnetic transient simulation, and there are very few works performing hardware test, and there is no clear understanding how the single-phase GFM inverter should behave from a hardware perspective. Therefore, this paper addresses the gap by performing hardware experiment to evaluate the performance of a single-phase GFM hardware inverter. We enrich the existing GFM testing protocols by investigating transient performance of GFM inverters under different grid dynamic events, and quantifiable performance metrics are made to have a common understanding of expected performance of single-phase GFM inverters. A commercial single-phase GFM inverter is used to verify the test protocols and understand the inverter's performance and functionalities.

dynamic events↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

F-16XL Hybrid Reynolds-Averaged Navier-Stokes/Large Eddy Simulation on Unstructured Grids

This study continues the Cranked Arrow Wing Aerodynamics Program, International (CAWAPI) investigation with the FUN3D and USM3D flow solvers. CAWAPI was established to study the F-16XL, because it provides a unique opportunity to fuse fight test, wind tunnel test, and simulation to understand the aerodynamic features of swept wings. The high-lift performance of the cranked-arrow wing planform is critical for recent and past supersonic transport design concepts. Simulations of the low speed high angle of attack Flight Condition 25 are compared: Detached Eddy Simulation (DES), Modi ed Delayed Detached Eddy Simulation (MDDES), and the Spalart-Allmaras (SA) RANS model. Iso- surfaces of Q criterion show the development of coherent primary and secondary vortices on the upper surface of the wing that spiral, burst, and commingle. SA produces higher pressure peaks nearer to the leading-edge of the wing than flight test measurements. Mean DES and MDDES pressures better predict the flight test measurements, especially on the outer wing section. Vorticies and vortex-vortex interaction impact unsteady surface pressures. USM3D showed many sharp tones in volume points spectra near the wing apex with low broadband noise and FUN3D showed more broadband noise with weaker tones. Spectra of the volume points near the outer wing leading-edge was primarily broadband for both codes. Without unsteady flight measurements, the flight pressure environment can not be used to validate the simulations containing tonal or broadband spectra. Mean forces and moment are very similar between FUN3D models and between USM3D models. Spectra of the unsteady forces and moment are broadband with a few sharp peaks for USM3D.