Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “geophysical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantifying EGS Reservoir Complexity with an Integrated Geophysical Approach-Improved Resolution Ambient Seismic Noise Interferometry

The primary goal of the project was met, as improved resolution (from kilometers to tens/hundreds of meters and to a depth of at least 3 km) was added to the seismic interferometry-estimated parameters relative to the work reported in AltaRock Energy Inc. (2014) for the Dixie Valley Geothermal Wellfield. A procedure for initial fault identification, using seismic interferometry, was developed. The project team further improved, and applied a new, cost-effective, and non-invasive exploration method, developed and validated since 2010, during two previous experiments, at Dixie Valley and Soda Lake, Nevada. The method, initially designed for hydrothermal exploration, was adapted to EGS exploration conditions, which require deeper crustal information. Regions of elevated energy for both the 2-7 Hz and 5-15 Hz frequency bands are located above intersections of multiple faults. Thus, an unprecedented, innovative seismic field deployment and ambient seismic noise and signal processing were successfully used to estimate crustal structure and to identify fault locations at depths up to 3 km, at a cost per kilometer of survey that in some cases may be as much as ten times less than the cost of a controlled-source survey. Based on valid and useful seismic data collected and analyzed during Phase I, in Phase II the team has further quantified statistically the advantage of using seismic analysis, in combination with other geological and geophysical techniques, for EGS target identification. A power spectral density analysis of the passive-seismic empirical Green’s functions reveals significantly higher power recorded over the exploration area at the power plant, and in the drilling area, near the BB station 10201, especially on the horizontal components. In this study, the most important relationship observed during the prior report, namely the one between velocity and temperature was explored. The areas that show anomalously high predicted temperature in the geostatistics occur where multiple faults intersect. Not surprisingly, such areas span between the Dixie Valley range front fault and the basin-ward Piedmont faults, in the vicinity of numerous wells. These locations also fall in the area of high EGS favorability from the prior 2014 study. The anomalies also coincide with the high power spectral density values. The result of altering all favorability criteria for the new data reached a maximum of 1/8th of a point and were not large enough to change any favorability value reported in the 2014 study. The new data reinforce the results obtained from the previous 2014 study. The current high-resolution ambient seismic noise project provided excellent results in defining faults in the wellfield. As such the identification of known faults by the project demonstrated the utility of this method for identifying faults at an exploration stage in geothermal development. Such fault identification, while extremely useful in exploration investigation, has not added sufficient new data for the generation of significantly different DVGW favorability maps in the current project. We believe the cost savings of our passive-seismic technique for EGS, over common industry active-source survey techniques, may have a minimum of 30%, and a maximum of 90%. There are many significant non-cost benefits of passive seismic surveys. Our passive-source method provides an environmentally-friendly seismic survey with minimal to negligible impacts. The economic benefit is greater EGS project feasibility.

15 GEOTHERMAL ENERGY↗

Build Guide for the Geophysical Monitoring System (GMS) Common Source Code 2019 Release

This document provides a "Build Guide" for a Generic Runnable System (GRS) of the Geophysical Monitoring Systems (GMS) common source code. This guide includes a list of software dependencies and licenses, hardware specifications, and instructions for how to build the system from the source code. The document is written for individuals who are experienced as administrators of Linux systems.

58 GEOSCIENCES↗

Infrasound Needs from a Future Geophysical Facility

Since the start of the SAGE/GAGE era, infrasound has become increasingly popular as both dedicated infrasound deplayments or coupled with other geophysical sensors for monitoring and research purposes, with interdisciplinary applications in both Earth and Atmospheric science. Infrasound can be used to study and monitor a variety of hazards that occur at or near the surface, including volcanic eruptions, earthquakes, and rapid gravity-driven mass movements. Because of this, it can help address some of the questions raised by recent community vision initiatives such as SZ4D (increase the understanding of the processes underlying subduction geohazards) and ERUPT (further our understanding of volcanic systems to help inform eruption forecasting). Many of the recommendations included here are topics of focus at workshops and conferences, including most recently at the November 2019 CONVERSE infrasound workshop. As NSF plans the successor to SAGE/GAGE, we advocate including infrasound in addition to the already-supported fields of seismology and geodesy. The two main features that we would like to see in the new facility are: 1) a community pool of infrasound instrumentation, and 2) the continuation and expansion of data management resources provided by the IRIS DMC.

58 GEOSCIENCES↗

Detection Thresholds and Sensitivities of Geophysical Techniques for CO2 Plume Monitoring

This report assesses capabilities and limitations of different geophysical techniques for monitoring geologic sequestration of CO 2 . Seismic, gravity, electrical, and electromagnetic (EM) techniques are considered. Monitoring approaches for site characterization prior to CO 2 injection are different from those used while injecting CO 2 , or those suitable for post-injection monitoring. The focus of this study is on the aspects relevant to long-term monitoring of large areas in the post-injection phase, and specifically on early detection of secondary CO 2 plumes.

54 ENVIRONMENTAL SCIENCES↗

Geophysical Imaging for Investigating the Delivery and Distribution of Amendments in the Heterogeneous Subsurface of the F.E. Warren AFB: ESTCP Project ER-200834

This study focused on improving our ability to develop conceptual amendment delivery models for in situ bioremediation and is based on the premise that geophysical imaging of amendment emplacement via hydraulic fracturing can reduce uncertainty in design and performance monitoring phases, thereby increasing efficacy and cost effectiveness of the remedial treatment.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Build Guide for the Geophysical Monitoring Systems Common Source Code. 2019 Release

The purpose of this document to provide an advance copy of a "Build Guide" for a Generic Runnable System (GRS) of the Geophysical Monitoring Systems' (GMS) common source code. This guide includes a list of software dependencies and licenses, hardware specifications, and related instructions for how to build the system from the source code. The document is written for individuals who are experienced as administrators of Linux systems. The intention is to support preparation activities prior to the open source release so that dependencies may be in place to build and run the system. This document will be updated and provided with the open source release on GitHub, accompanied by a "Run Guide" for the system. An additional "Configuration Guide" will also be provided after the open source release so that users may explore system configuration options.

58 GEOSCIENCES↗

Geophysical Methods for Stratigraphic Identification

The goal of this work is to identify geophysical methods that can be used to delineate (in 3D) a large-scale paleochannel that has been inferred to exist between the 200 West and 200 East Areas of the Hanford Site’s Central Plateau . This paleochannel is of particular importance because it will significantly impact flow and contaminant transport from 200 West to 200 East. Its high permeability can both accelerate contaminant transport and lower contaminant concentrations through spreading. Information about the spatial extent and structure of such features is needed to inform subsurface flow and contaminant transport models that support remedy decisions at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SMART Cables Initiative for Ocean and Geophysical Observing [Slides]

SMART Cables are becoming a reality, and have the potential to revolutionize submarine oceanographic and geophysical sensing. Pilot / demonstration projects are underway to test the technology and explore the feasibility of incorporating both in-repeater standardized sensor packets but also ancillary sensor types on external, branching nodes. The projects currently in planning will set the standard and influence the norms for the future of SMART systems. The interest of all potential stakeholders and users, and input as to needs and concerns, is welcomed as testing proceeds.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the CarbonSAFE Seal Integrity Wells in the Illinois Basin

The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) researchers in Morgantown, West Virginia, utilized computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) to evaluate the integrity of three cores (Geophysical Monitor #2 (GM2), Verification Well #1 (VW #1), and Wabash #1 for the Illinois Basin Carbon Storage Assurance Facility Enterprise (CarbonSAFE) efforts. This work was carried out in collaboration with the Illinois State Geological Survey (ISGS) as part of their efforts to analyze cores from two field locations, including the Illinois Basin-Decatur Project (IBDP) and second stage Illinois Industrial Carbon Capture and Storage (IL-ICCS) sites at Decatur, Illinois, and the Wabash CarbonSAFE project at the Wabash Valley Resources Integrated Gasification Combined Cycle plant in Terre Haut, Indiana. The results of this study are presented in several formats and are available online on the Energy Data eXchange (EDX). The rock characterization was conducted using non-destructive techniques, allowing for future analysis of the cores. While the equipment used did not provide direct visualization of shale pore space, it allowed for detection of fractures and discontinuities. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were utilized to identify areas of interest for further study as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy-related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

FutureGen 2.0 Monitoring Systems Design Basis and Technology Selection: Geohydrologic, Geochemical and Geophysical Considerations

Advances in carbon capture and storage (CCS) technology show promise for addressing carbon dioxide (CO 2 ) emissions and global climate change concerns related to coal-fueled energy. The FutureGen 2.0 Project is intended to demonstrate 1) the technical feasibility of oxy-combustion technology as an approach for implementing carbon capture at new and existing coal-fueled energy facilities, and 2) utility-scale integration of transport and permanent storage of captured CO 2 in a deep geologic formation. Development of the FutureGen 2.0 CO 2 storage site is part of a larger project to design, build, and operate a commercial-scale CCS system capable of capturing, treating, and storing the CO 2 off-gas from a 168-MW(e) gross capacity oxy-combustion coal-fueled power plant located in Meredosia, Illinois—a first-of-its-kind, near-zero emissions coal-fueled power plant with CCS. In cooperation with the U.S. Department of Energy, the FutureGen 2.0 project partners will repower a previously retired oil-fired power plant with oxy-combustion technology to capture approximately 1.1 million metric tons of CO 2 each year—more than 90 percent of the plant’s carbon emissions. Emissions such as sulfur oxides, nitrogen oxides, and mercury will be reduced to near-zero levels. Safe and proven pipeline technology will be used to transport the CO 2 to the storage site and inject it deep into the subsurface through a network of deep-injection wells for long-term storage through geologic sequestration. An evaluation that considered pertinent hydrologic, geochemical, and geophysical processes was performed during development of the testing and monitoring program for the FutureGen 2.0 project. This evaluation informed the technology screening process and, in conjunction with project- and regulation-driven monitoring objectives, was the basis for monitoring technology selection. A summary of the overall monitoring approach adopted by the FutureGen 2.0 project, and a detailed description of the testing and monitoring activities that the FutureGen Industrial Alliance, Inc. will undertake at the FutureGen 2.0 storage site near Jacksonville, Illinois, are documented in a project-maintained testing and monitoring plan. All testing and monitoring activities will be performed in accordance with Title 40 of the Code of Federal Regulations (CFR) Sections 146.89, 146.90, and 146.91 (40 CFR §146.89, 146.90, and 146.91) to verify that the storage site is operating as permitted and is not endangering any underground sources of drinking water (USDWs).

54 ENVIRONMENTAL SCIENCES↗

Requirements for Cataloging Hanford Geophysical Datasets

Environmental management activities at the Hanford Site produce extensive data about site conditions, contaminants, cleanup, and more. Managing and archiving that data requires a high degree of collaboration among site contractors and a high level of awareness by project managers and staff. Part of that effort is developing a Hanford Environmental Information and Data Index (HEIDI) to organize the data and maximize its value by making it findable and available for reuse. The objective is to catalog the disparate data sets collected to address the evolving needs of planning, executing, and documenting cleanup over several decades up to the present day, including links to active data sources when available. A properly implemented data catalog makes finding environmental datasets related to an area or theme a routine, reliable process, without requiring the searcher to have special knowledge that a data set exists and where it may be stored. In this project, a working group, including the U.S. Department of Energy, the Hanford Site contractors, and Pacific Northwest National Laboratory staff, identified needs and requirements for handling complex site data. Geophysical data was chosen as a test case because it can be large and complex and often involves multiple processing steps to extract the information incorporated into deliverables. The ability to document those steps was one of the requirements identified for the catalog. In addition to developing requirements, other activities included selecting a metadata schema and initial testing with the objective of determining whether the workflow and capabilities of selected data catalog software platforms were sufficient to implement and impose the identified requirements. This initial testing involved running the default catalog instance using the software platform of interest and altering the configuration to achieve each requirement, if possible. Where configuration alone was insufficient, the possibility of modifying the software by changing the code was examined, but not implemented. A follow-on task is planned to reprogram the code as necessary to implement requirements in a prototype catalog.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geophysical Imaging of Flow and Transport (GIFT): FY24 Status Report

The GIFT (Geophysical Imaging of Flow and Transport) system will improve predictive capabilities as a platform for collecting multi-physical (MP) time-lapse datasets from well-controlled laboratory experiments. This will enable more accurate prediction of multi-phase fluid flow during delivery and transport of insitu remedial amendments as important components of the overall Hanford Site cleanup mission. Design and construction of the GIFT system, which consists of a meter-scale test cell and a network of custom gas circulation and analysis systems, was accomplished in fiscal year (FY) 2024, with plans to add liquid circulation to the system and use this new capability for multi-phase deep vadose experiments starting in FY25.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Geophysical Technique for Mineral Exploration and Mineral Discrimination Based on Electromagnetic Methods

The research during the first two years of the project was focused on developing the foundations of a new geophysical technique for mineral exploration and mineral discrimination, based on electromagnetic (EM) methods. The developed new technique is based on examining the spectral induced polarization effects in electromagnetic data using effective-medium theory and advanced methods of 3-D modeling and inversion. The analysis of IP phenomena is usually based on models with frequency dependent complex conductivity distribution. In this project, we have developed a rigorous physical/mathematical model of heterogeneous conductive media based on the effective-medium approach. The new generalized effective-medium theory of IP effect (GEMTIP) provides a unified mathematical method to study heterogeneity, multi-phase structure, and polarizability of rocks. The geoelectrical parameters of a new composite conductivity model are determined by the intrinsic petrophysical and geometrical characteristics of composite media: mineralization and/or fluid content of rocks, matrix composition, porosity, anisotropy, and polarizability of formations. The new GEMTIP model of multi-phase conductive media provides a quantitative tool for evaluation of the type of mineralization, and the volume content of different minerals using electromagnetic data. We have developed a 3-D EM-IP modeling algorithm using the integral equation (IE) method. Our IE forward modeling software is based on the contraction IE method, which improves the convergence rate of the iterative solvers. This code can handle various types of sources and receivers to compute the effect of a complex resistivity model. We have demonstrated that the generalized effective-medium theory of induced polarization (GEMTIP) in combination with the IE forward modeling method can be used for rock-scale forward modeling from grain-scale parameters. The numerical modeling study clearly demonstrates how the various complex resistivity models manifest differently in the observed EM data. These modeling studies lay a background for future development of the IP inversion method, directed at determining the electrical conductivity and the intrinsic chargeability distributions, as well as the other parameters of the relaxation model simultaneously. The new technology introduced in this project can be used for the discrimination between uneconomic mineral deposits and the location of zones of economic mineralization and geothermal resources.

15 GEOTHERMAL ENERGY↗

SURFACE GEOPHYSICAL EXPLORATION OF B & BX & BY TANK FARMS AT THE HANFORD SITE RESULTS OF BACKGROUND CHARACTERIZATION WITH MAGNETICS AND ELECTROMAGNETICS

This report documents the results of preliminary surface geophysical exploration activities performed between October and December 2006 at the B, BX, and BY tank farms (B Complex). The B Complex is located in the 200 East Area of the U. S. Department of Energy's Hanford Site in Washington State. The objective of the preliminary investigation was to collect background characterization information with magnetic gradiometry and electromagnetic induction to understand the spatial distribution of metallic objects that could potentially interfere with the results from high resolution resistivity survey. Results of the background characterization show there are several areas located around the site with large metallic subsurface debris or metallic infrastructure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the resolution of inexpensive, novel non-seismic geophysical monitoring tools to monitor CO2 injection into coal beds

A sensitivity study of gravity and electromagnetic (EM) techniques, and amplitude vs. angle (AVA) analysis for CO{sub 2} movement in coal beds was based on the SECARB pilot test planned in the Black Warrior basin in Alabama. In the area of interest, coalbed methane is produced mainly from the Black Creek, Mary Lee, and Pratt coal zones at depths between 400 and 700 m and approximately 3 m thick on average. The permeability of coal in the Black Warrior basin decreases exponentially with depth as overburden stress increases. The permeability of the top layer is 100 mD, while the permeability of the deepest layer is around 1 mD. The pilot field test will include injecting a total of 1000 tons of CO{sub 2} into these three coal zones ({approx}300 tons to each zone). The density, sonic and resistivity well-logs from a deep disposal well a couple of miles from the pilot test site were used to create background (pre-injection) models. Our laboratory measurements of seismic velocity and electrical resistivity as a function of CO{sub 2} saturation on coal core samples were used to provide a link between the coalbed CO{sub 2} flow simulation models and the geophysical models. The sensitivity studies showed that while the response to the 300 tons of CO{sub 2} injected into a single layer wouldn't produce measurable surface response for either gravity or EM, the response due to an industrial-size injection would produce measurable surface signal for both techniques. Gravity inversion results illustrated that, provided we can collect high-quality gravity data in the field and we have some a priori information about the depth of the reservoir, we can recover the spatial location of CO{sub 2} plume correctly, although with the smoothing constraint of the inversion, the area was slightly overestimated, resulting in an underestimated value of density change. AVA analysis showed that by inverting seismic and EM data jointly, much better estimates of CO{sub 2} saturation can be obtained, especially in the third injection zone, where seismic AVA data fail to detect the high CO{sub 2} saturation. Analysis of spatial resolution and detectability limits show that gravity and EM measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

54 ENVIRONMENTAL SCIENCES↗