Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functionally graded material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Optical properties of a nanostructured glass-based film using spectroscopic ellipsometry

Nanostructured glass films, which are fabricated using spinodally phase-separated low-alkali glasses, have several interesting and useful characteristics, including being robust, non-wetting and antireflective. Spectroscopic ellipsometry measurements have been performed on one such film and its optical properties were analyzed using a 5-layer structural model of the near-surface region. Since the glass and the film are transparent over the spectral region of the measurement, the Sellmeier model is used to parameterize the dispersion in the refractive index. To simulate the variation of the optical properties of the film over the spot size of the ellipsometer (~ 3 × 5 mm), the Sellmeier amplitude is convoluted using a Gaussian distribution. The transition layers between the ambient and the film and between the film and the substrate are modeled as graded layers, where the refractive index varies as a function of depth. These layers are modeled using a two-component Bruggeman effective medium approximation where the two components are the layer above and the layer below. Lastly, the fraction is continuous through the transition layer and is modelled using the incomplete beta function.

36 MATERIALS SCIENCE↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

Phase II Study of Neoadjuvant Bevacizumab and Radiotherapy for Resectable Soft Tissue Sarcomas

Purpose: Numerous preclinical studies have demonstrated that angiogenesis inhibitors can increase the efficacy of radiotherapy (RT). We sought to examine the safety and efficacy of bevacizumab (BV) and RT in soft tissue sarcomas and explore biomarkers to help determine the treatment response. Methods and Materials: Patients with {>=}5 cm, intermediate- or high-grade soft tissue sarcomas at significant risk of local recurrence received neoadjuvant BV alone followed by BV plus RT before surgical resection. Correlative science studies included analysis of the serial blood and tumor samples and serial perfusion computed tomography scans. Results: The 20 patients had a median tumor size of 8.25 cm, with 13 extremity, 1 trunk, and 6 retroperitoneal/pelvis tumors. The neoadjuvant treatment was well tolerated, with only 4 patients having Grade 3 toxicities (hypertension, liver function test elevation). BV plus RT resulted in {>=}80% pathologic necrosis in 9 (45%) of 20 tumors, more than double the historical rate seen with RT alone. Three patients had a complete pathologic response. The median microvessel density decreased 53% after BV alone (p <.05). After combination therapy, the median tumor cell proliferation decreased by 73%, apoptosis increased 10.4-fold, and the blood flow, blood volume, and permeability surface area decreased by 62-72% (p <.05). Analysis of gene expression microarrays of untreated tumors identified a 24-gene signature for treatment response. The microvessel density and circulating progenitor cells at baseline and the reduction in microvessel density and plasma soluble c-KIT with BV therapy also correlated with a good pathologic response (p <.05). After a median follow-up of 20 months, only 1 patient had developed local recurrence. Conclusions: The results from the present exploratory study indicated that BV increases the efficacy of RT against soft tissue sarcomas and might reduce the incidence of local recurrence. Thus, this regimen warrants additional investigation. Gene expression profiles and other tissue and circulating biomarkers showed promising correlations with treatment response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of surface pattern on the biological properties of Ti grade 2

Highlights: • Laser modification causes changes in chemical composition of the surface. • Laser treatment creates roughness in a range from nano- to micrometers. • The surface modification presented results in a multimodal topography. • A hierarchical topography promotes protein adsorption. - Abstract: This paper presents a detailed characterization of Ti surface geometries as produced by non-contact laser functionalization and its impact on the process of protein adsorption. The proposed surface modification is designed for the local treatment of implantable devices with original roughness. In this work, titanium plates were initially modified by the two most common mechano-chemical treatments, shot peening and acid etching. The material under study was next functionalized DLIL (Direct Laser Interference Lithography) in order to obtained two different surface patterns: grooves and islands. The modified surfaces were characterized in terms of their shape, roughness, wettability, surface energy and chemical composition. For this purpose, the following methods were used: scanning electron microscopy, optical profilometry, atomic force microscopy, contact angle measurements, and X-ray photoelectron spectroscopy. Protein adsorption tests were conducted to consider the potential of the proposed methodology in biomedical applications and to compare the influence of the two different surface patterns on the initial state of ossointegration. To this end, XPS and FTIR studies were conducted. The systematic analysis presented will be useful when selecting an appropriate surface geometry for the local surface functionalization of implantable devices.

36 MATERIALS SCIENCE↗

Approach to using 3D laser-induced breakdown spectroscopy (LIBS) data to explore the interaction of FLiNaK and FLiBe molten salts with nuclear-grade graphite

Nuclear graphite has historically been a key component of many nuclear reactor designs and has emerged as key to numerous advanced nuclear reactor design concepts. Molten salt reactors (MSRs) are one broad group of advanced reactor designs currently being pursued by industry for commercialization. Several MSR designs under consideration use graphitic materials that directly interface with a molten salt, whether it is a fuel salt, coolant salt, or both. Therefore, the interaction of graphite materials with molten salts must be understood. To gain this required understanding, a range of data is needed including porosity, strength, and composition as a function of different salt exposure parameters. In this study, a laser-induced breakdown spectroscopy (LIBS) measurement and data analysis methodology was developed to obtain spatially resolved elemental composition information for graphite samples exposed to a molten fluoride salt. Traditional univariate emission line analysis of atomic, ionic, and molecular optical emission signals was coupled via correlation analysis with spectral decomposition of the data using principal component analysis. Elemental depth profiling and elemental mapping were also performed to visualize salt–graphite interactions. LIBS was demonstrated to be useful for measuring key analytes such as fluorine and hydrogen, which are troublesome for other analysis techniques. Evidence for complex behavior was found, thereby demonstrating the usefulness of the developed approach for future systematic studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secondary Electron Emission from Plasma Processed Accelerating Cavity Grade Niobium

Advances in the particle accelerator technology have enabled numerous fundamental discoveries in 20th century physics. Extensive interdisciplinary research has always supported further development of accelerator technology in efforts of reaching each new energy frontier. Accelerating cavities, which are used to transfer energy to accelerated charged particles, have been one of the main focuses of research and development in the particle accelerator field. Over the last fifty years, in the race to break energy barriers, there has been constant improvement of the maximum stable accelerating field achieved in accelerating cavities. Every increase in the maximum attainable accelerating fields allowed for higher energy upgrades of existing accelerators and more compact designs of new accelerators. Each new and improved technology was faced with ever emerging limiting factors. With the standard high accelerating gradients of more than 25 MV/m, free electrons inside the cavities get accelerated by the field, gaining enough energy to produce more electrons in their interactions with the walls of the cavity. The electron production is exponential and the electron energy transfer to the walls of a cavity can trigger detrimental processes, limiting the performance of the cavity. The root cause of the free electron number gain is a phenomenon called Secondary Electron Emission (SEE). Even though the phenomenon has been known and studied over a century, there are still no effective means of controlling it. The ratio between the electrons emitted from the surface and the impacting electrons is defined as the Secondary Electron Yield (SEY). A SEY ratio larger than 1 designates an increase in the total number of electrons. In the design of accelerator cavities, the goal is to reduce the SEY to be as low as possible using any form of surface manipulation. In this dissertation, an experimental setup was developed and used to study the SEY of various sample surfaces that were treated by different techniques. Specifically, this work provides the results of SEY from the plasma cleaned cavity grade niobium (Nb) samples. Pure niobium is currently the material of choice for the fabrication of Superconducting Radio Frequency (SRF) cavities. The effect of plasma processing with two different gases will be examined in two groups of samples. The first group of samples is made from cavity grade niobium. The second group of samples is made from the same material, but include a welded joint made by electron beam welding, since in niobium SRF cavities the peak electric and magnetic field are seen in close proximity to the welded joints. Both groups of samples will be exposed to nitrogen (N2) and a mixture of argon with oxygen (Ar/O2) plasma. It is the goal of this research to determine the SEY on these two groups of samples before and after plasma processing as a function of the energy of primary electrons. The SEY as a function of the angle of incidence of the primary electrons is tested on the samples treated with Ar/O2 plasma.

43 PARTICLE ACCELERATORS↗

Supratentorial Ependymoma: Disease Control, Complications, and Functional Outcomes After Irradiation

Purpose: Ependymoma is less commonly found in the supratentorial brain and has known clinical and molecular features that are unique. Our single-institution series provides valuable information about disease control for supratentorial ependymoma and the complications of supratentorial irradiation in children. Methods and Materials: A total of 50 children with newly diagnosed supratentorial ependymoma were treated with adjuvant radiation therapy (RT); conformal methods were used in 36 after 1996. The median age at RT was 6.5 years (range, 1-18.9 years). The entire group was characterized according to sex (girls 27), race (white 43), extent of resection (gross-total 46), and tumor grade (anaplastic 28). The conformal RT group was prospectively evaluated for neurologic, endocrine, and cognitive effects. Results: With a median follow-up time of 9.1 years from the start of RT for survivors (range, 0.2-23.2 years), the 10-year progression-free and overall survival were 73% + 7% and 76% + 6%, respectively. None of the evaluated factors was prognostic for disease control. Local and distant failures were evenly divided among the 16 patients who experienced progression. Eleven patients died of disease, and 1 of central nervous system necrosis. Seizure disorders were present in 17 patients, and 4 were considered to be clinically disabled. Clinically significant cognitive effects were limited to children with difficult-to-control seizures. The average values for intelligence quotient and academic achievement (reading, spelling, and math) were within the range of normal through 10 years of follow-up. Central hypothyroidism was the most commonly treated endocrinopathy. Conclusion: RT may be administered with acceptable risks for complications in children with supratentorial ependymoma. These results suggest that outcomes for these children are improving and that complications may be limited by use of focal irradiation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathophysiology and Natural History of Anorectal Sequelae Following Radiation Therapy for Carcinoma of the Prostate

Purpose: To characterize the prevalence, pathophysiology, and natural history of chronic radiation proctitis 5 years following radiation therapy (RT) for localized carcinoma of the prostate. Methods and Materials: Studies were performed in 34 patients (median age 68 years; range 54-79) previously randomly assigned to either 64 Gy in 32 fractions over 6.4 weeks or 55 Gy in 20 fractions over 4 weeks RT schedule using 2- and later 3-dimensional treatment technique for localized prostate carcinoma. Each patient underwent evaluations of (1) gastrointestinal (GI) symptoms (Modified Late Effects in Normal Tissues Subjective, Objective, Management and Analytic scales including effect on activities of daily living [ADLs]); (2) anorectal motor and sensory function (manometry and graded balloon distension); and (3) anal sphincteric morphology (endoanal ultrasound) before RT, at 1 month, and annually for 5 years after its completion. Results: Total GI symptom scores increased after RT and remained above baseline levels at 5 years and were associated with reductions in (1) basal anal pressures, (2) responses to squeeze and increased intra-abdominal pressure, (3) rectal compliance and (4) rectal volumes of sensory perception. Anal sphincter morphology was unchanged. At 5 years, 44% and 21% of patients reported urgency of defecation and rectal bleeding, respectively, and 48% impairment of ADLs. GI symptom scores and parameters of anorectal function and anal sphincter morphology did not differ between the 2 RT schedules or treatment techniques. Conclusions: Five years after RT for prostate carcinoma, anorectal symptoms continue to have a significant impact on ADLs of almost 50% of patients. These symptoms are associated with anorectal dysfunction independent of the RT schedules or treatment techniques reported here.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A strong and ductile Super Kovar alloy via fully coherent nanoprecipitates

Emerging high-precision technologies demand materials with exceptional dimensional stability and mechanical robustness, as even microscopic thermomechanical deformation can cause functional failure. However, a fundamental trilemma exists: High strength, ductility, and low thermal expansion are mutually exclusive, as strengthening-induced lattice distortions compromise the spin-lattice coupling, which is essential for low thermal expansion. Here, we overcome this trilemma by designing “Super Kovar,” an Fe-Ni-Co-Al-Ta alloy, featuring fully coherent nanoprecipitates. It unifies a 1.0-gigapascal ultimate tensile strength and ∼39% elongation with a Kovar-grade thermal expansion of 3.81 × 10−6 K−1 (100 to 410 K). The key is a dense dispersion of L12 nanoprecipitates that form an almost strain-free coherent interface with the ferromagnetic matrix. Beyond providing precipitation strengthening, these coherent interfaces suppress intrinsic phonons of nanoprecipitates via elastic coupling while avoiding magnetic domain pinning to preserve the Invar effect of the matrix. This reduces the thermal expansion of the precipitates by 56% and achieves a fourfold enhancement in the strength-ductility product, establishing a paradigm for dimensionally stable, ultrastrong alloys.

Yu, Chengyi [University of Science and Technology ↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Experimental Investigation of Gas/Slag/Matte/Tridymite Equilibria in the Cu-Fe-O-S-Si System in Controlled Gas Atmospheres: Experimental Results at 1473 K (1200 °C) and P(SO{sub 2}) = 0.25 atm

Experimental studies were undertaken to determine the gas/slag/matte/tridymite equilibria in the Cu-Fe-O-S-Si system at 1473 K (1200 °C), P(SO{sub 2}) = 0.25 atm, and a range of P(O{sub 2})’s. The experimental methodology involved high-temperature equilibration using a substrate support technique in controlled gas atmospheres (CO/CO{sub 2}/SO{sub 2}/Ar), rapid quenching of equilibrium phases, followed by direct measurement of the chemical compositions of the phases with Electron Probe X-ray Microanalysis (EPMA). The experimental data for slag and matte were presented as a function of copper concentration in matte (matte grade). The data provided are essential for the evaluation of the effect of oxygen potential under controlled atmosphere on the matte grade, liquidus composition of slag and chemically dissolved copper in slag. The new data provide important accurate and reliable quantitative foundation for improvement of the thermodynamic databases for copper-containing systems.

36 MATERIALS SCIENCE↗

Influence of printing parameters on the mechanical behavior of 3D-printed SS316L parts manufactured using laser hot wire directed energy deposition

Hybrid manufacturing combines the simultaneous benefits of additive manufacturing (complex geometries, part consolidation, and mass customization) with the advantages of subtractive manufacturing (superior surface finish and enhanced dimensional accuracies) by integrating a suite of complementary traditional processes into a base platform of additive manufacturing. The use of hybrid technology has grown in recent years given its capabilities on repairing metallic structures, producing parts with conformal cooling features, and manufacturing functionally graded products. These kinds of capabilities are of great interest to the medical implant, energy, automotive, maritime, and aerospace industry sectors, among many other fields. This work investigated the mechanical properties of stainless steel (SS) 316L as a function of different tool paths strategies using an integrated 5-axis CNC hybrid Mazak system with a laser hot wire deposition system (LHWDS). This study includes the evaluation of different printing parameters and their impact on the quality of the printed bead as well as the incorporation of a structure–property material relationship based on the mechanical performance of the manufactured coupons.

36 MATERIALS SCIENCE↗

MATERIAL CONTROL ACCOUNTING INMM

Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

99 GENERAL AND MISCELLANEOUS↗

Additive Manufacturing of Ultrahigh Temperature Refractory Metal Alloys

The project advances the manufacture of RMA for ultrahigh-temperature service with three main innovations: a thermodynamically derived high-throughput AM synthesis and characterization using reactive synthesis of elemental powders, a new dimensional number to predict processing parameters, and a novel processing scheme for the fabrication of components with functional grading microstructures. With these advances, the project demonstrates in Phase I the manufacture of RMAs exhibiting room temperature compression ductility above 20%, room temperature fracture toughness above 10 MPam 0.5 , and the fabrication of tensile test samples that have a transformative impact on the manufacturing of RMAs by enabling cost-efficient and large-scale fabrication of components.

33 ADVANCED PROPULSION SYSTEMS↗

Oak Ridge National Laboratory Thermoplastic Composite Joining of Pultruded Continuous Fiber Spars for Multi-Functional Battery Enclosure

Oak Ridge National Laboratory (ORNL) worked with DowAksa Industry to investigate the potential of using PA66 material to produce larger composite parts, transcending the limitations of traditional presses. The project aimed to develop a suitable material for printing battery boxes using Nylon 66 infused with 40 wt.% carbon fiber, compatible with the ORNL Additive Manufacturing and Compression Molding (AM-CM) system. However, even with extensive work, it was concluded that the material is not compatible with the AMCM process and suitable for joining using compression technique. Main reason for the incompatibility were found to be very high crystallinity of the PA66 grade chosen for this work. To improve printability, a modifier (proprietary) was added to decrease crystallinity, but this led to reduced thermal stability and adhesion issues.

36 MATERIALS SCIENCE↗

Patterns of Response After Preoperative Intensity-Modulated Radiation Therapy and Capecitabine/Oxaliplatin in Rectal Cancer: Is There Still a Place for Ecoendoscopic Ultrasound?

Purpose: The main goals of preoperative chemoradiotherapy (CHRT) in rectal cancer are to achieve pathological response and to ensure tumor control with functional surgery when possible. Assessment of the concordance between clinical and pathological responses is necessary to make decisions regarding alternative conservative procedures. The present study evaluates the patterns of response after a preoperative CHRT regimen, and the value of endoscopic ultrasound (EUS) in assessing response. Methods and Materials: A total of 51 EUS-staged T3 to T4 and/or N0 to N+ rectal cancer patients received preoperative CHRT (intensity-modulated radiation therapy and capecitabine/oxaliplatin (XELOX) followed by radical resection. Clinical response was assesed by EUS. Rates of pathological tumor regression grade (TRG) and lymph node (LN) involvement were determined in the surgical specimen. Clinical and pathological responses were compared, and the accuracy of EUS in assessing response was calculated. Results: Twenty-four patients (45%) achieved a major pathological response (complete or >95% pathological response (TRG 3+/4)). Sensitivity, specificity, negative predictive value, and positive predictive value of EUS in predicting pathological T response after preoperative CHRT were 77.8%, 37.5%, 60%, and 58%, respectively. The EUS sensitivity, specificity, negative predictive value, and positive predictive value for nodal staging were 44%, 88%, 88%, and 44%, respectively. Furthermore, EUS after CHRT accurately predicted the absence of LN involvement in 7 of 7 patients (100%) with major pathological response of the primary tumor. Conclusion: Preoperative IMRT with concomitant XELOX induces favorable rates of major pathological response. EUS has a limited ability to predict primary tumor response after preoperative CHRT, but it is useful for accurately determining LN status. EUS may have a potential value in identifying patients with a very low risk of LN involvement in association with a good pathological response as potential candidates for conservative local surgical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM Polymorphisms Predict Severe Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: The ataxia telangiectasia mutated (ATM) gene mediates detection and repair of DNA damage. We investigated associations between ATM polymorphisms and severe radiation-induced pneumonitis (RP). Methods and Materials: We genotyped 3 potentially functional single nucleotide polymorphisms (SNPs) of ATM (rs1801516 [D1853N/5557G>A], rs189037 [-111G>A] and rs228590) in 362 patients with non-small cell lung cancer (NSCLC), who received definitive (chemo)radiation therapy. The cumulative severe RP probabilities by genotypes were evaluated using the Kaplan-Meier analysis. The associations between severe RP risk and genotypes were assessed by both logistic regression analysis and Cox proportional hazard model with time to event considered. Results: Of 362 patients (72.4% of non-Hispanic whites), 56 (15.5%) experienced grade ≥3 RP. Patients carrying ATM rs189037 AG/GG or rs228590 TT/CT genotypes or rs189037G/rs228590T/rs1801516G (G-T-G) haplotype had a lower risk of severe RP (rs189037: GG/AG vs AA, adjusted hazard ratio [HR] = 0.49, 95% confidence interval [CI], 0.29-0.83, P=.009; rs228590: TT/CT vs CC, HR=0.57, 95% CI, 0.33-0.97, P=.036; haplotype: G-T-G vs A-C-G, HR=0.52, 95% CI, 0.35-0.79, P=.002). Such positive findings remained in non-Hispanic whites. Conclusions: ATM polymorphisms may serve as biomarkers for susceptibility to severe RP in non-Hispanic whites. Large prospective studies are required to confirm our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-temperature structure, elasticity, and thermal expansion of ε-ZrH 1.8

Zirconium hydride is a promising candidate material for nuclear microreactor applications as a solid-state moderator component, owing to its favorable neutronics properties and good thermal stability over other metal hydrides. Here, in the present work, the crystal structure, thermal expansion, and elastic properties of the hydrogen-rich ε phase hydride were measured at elevated temperatures in the range 300–900 K. Samples were prepared by direct hydriding Zircaloy-4 metal – a nuclear-grade zirconium alloy. Room-temperature lattice parameters agree well with those reported from literature for unalloyed zirconium hydride and fall within an observed quadratic H-content dependence. The coefficients of thermal expansion, determined from lattice expansion and dilatometry, agree well within our work but were about 30 % lower than those reported by others for unalloyed hydrides. Density functional theory-based molecular dynamics simulations were used to compare with thermal expansion and elasticity measurements. Results showed lattice parameter temperature dependence and slope of thermal expansion align with those from measurements. Based on diffraction scans at select temperatures, ε phase remained stable in air up to at least 770 K. Likewise, dilatometry showed smooth thermal expansion up to the thermal decomposition temperature around 950 K. The precise decomposition temperature was not determined via diffraction due to sparse scanning. The complete elastic property measurements were gathered for ε-phase Ziracloy-4 hydride for the first time. Young's modulus was lower compared to the metal and δ hydride phases. High-temperature elasticity measurements were limited to <350 K due to acoustic dissipation effects.

36 MATERIALS SCIENCE↗