U 3 Si 2 Fabrication and Testing for Implementation into the BISON Fuel Performance Code
A creep test stand was designed and constructed for compressive creep testing of U 3 Si 2 pellets. This is described in Chapter 3. Creep testing of U 3 Si 2 pellets was completed. In total, 13 compressive creep tests of U 3 Si 2 pellets was successfully completed. This is reported in Chapter 3. Secondary creep model of U 3 Si 2 was developed and implemented in BISON. This is described in Chapter 4. Properties of U 3 Si 2 were implemented in BISON. This is described in Chapter 4. A resonant frequency and damping analyzer (RFDA) using impulse excitation technique (IET) was setup, tested, and used to analyze U 3 Si 2 samples to measure Young’s and Shear Moduli which were then used to calculate the Poisson ratio for U 3 Si 2 . This is described in Chapter 5. Characterization of U 3 Si 2 samples was completed. Samples were prepared and analyzed by XRD, SEM, and optical microscopy. Grain size analysis was conducted on images. SEM with EDS was used to analyze second phase precipitates. Impulse excitation technique was used to determine the Young’s and Shear Moduli of a tile specimen which allowed for the determination of the Poisson ratio. Helium pycnometry and mercury intrusion porosimetry was performed and used with image analysis to determine porosity size distribution. Vickers microindentation characterization method was used to evaluate the mechanical properties of U 3 Si 2 including toughness, hardness, and Vickers hardness. Electrical resistivity measurement was done using the four-point probe method. This is reported in Chapter 5.