Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Single-Chip FPGA Azimuth Pre-Filter for SAR

A field-programmable gate array (FPGA) on a single lightweight, low-power integrated-circuit chip has been developed to implement an azimuth pre-filter (AzPF) for a synthetic-aperture radar (SAR) system. The AzPF is needed to enable more efficient use of data-transmission and data-processing resources: In broad terms, the AzPF reduces the volume of SAR data by effectively reducing the azimuth resolution, without loss of range resolution, during times when end users are willing to accept lower azimuth resolution as the price of rapid access to SAR imagery. The data-reduction factor is selectable at a decimation factor, M, of 2, 4, 8, 16, or 32 so that users can trade resolution against processing and transmission delays. In principle, azimuth filtering could be performed in the frequency domain by use of fast-Fourier-transform processors. However, in the AzPF, azimuth filtering is performed in the time domain by use of finite-impulse-response filters. The reason for choosing the time-domain approach over the frequency-domain approach is that the time-domain approach demands less memory and a lower memory-access rate. The AzPF operates on the raw digitized SAR data. The AzPF includes a digital in-phase/quadrature (I/Q) demodulator. In general, an I/Q demodulator effects a complex down-conversion of its input signal followed by low-pass filtering, which eliminates undesired sidebands. In the AzPF case, the I/Q demodulator takes offset video range echo data to the complex baseband domain, ensuring preservation of signal phase through the azimuth pre-filtering process. In general, in an SAR I/Q demodulator, the intermediate frequency (fI) is chosen to be a quarter of the range-sampling frequency and the pulse-repetition frequency (fPR) is chosen to be a multiple of fI. The AzPF also includes a polyphase spatial-domain pre-filter comprising four weighted integrate-and-dump filters with programmable decimation factors and overlapping phases. To prevent aliasing of signals, the bandwidth of the AzPF is made 80 percent of fPR/M. The choice of four as the number of overlapping phases is justified by prior research in which it was shown that a filter of length 4M can effect an acceptable transfer function. The figure depicts prototype hardware comprising the AzPF and ancillary electronic circuits. The hardware was found to satisfy performance requirements in real-time tests at a sampling rate of 100 MHz.

Gudim, Mimi↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

3D Display Using Conjugated Multiband Bandpass Filters

Stereoscopic display techniques are based on the principle of displaying two views, with a slightly different perspective, in such a way that the left eye views only by the left eye, and the right eye views only by the right eye. However, one of the major challenges in optical devices is crosstalk between the two channels. Crosstalk is due to the optical devices not completely blocking the wrong-side image, so the left eye sees a little bit of the right image and the right eye sees a little bit of the left image. This results in eyestrain and headaches. A pair of interference filters worn as an optical device can solve the problem. The device consists of a pair of multiband bandpass filters that are conjugated. The term "conjugated" describes the passband regions of one filter not overlapping with those of the other, but the regions are interdigitated. Along with the glasses, a 3D display produces colors composed of primary colors (basis for producing colors) having the spectral bands the same as the passbands of the filters. More specifically, the primary colors producing one viewpoint will be made up of the passbands of one filter, and those of the other viewpoint will be made up of the passbands of the conjugated filter. Thus, the primary colors of one filter would be seen by the eye that has the matching multiband filter. The inherent characteristic of the interference filter will allow little or no transmission of the wrong side of the stereoscopic images.

Bae, Youngsam↗

Radiation Hard Bandpass Filters for Mid- to Far-IR Planetary Instruments

We present a novel method to fabricate compact metal mesh bandpass filters for use in mid- to far-infrared planetary instruments operating in the 20-600 micron wavelength spectral regime. Our target applications include thermal mapping instruments on ESA's JUICE as well as on a de-scoped JEO. These filters are novel because they are compact, customizable, free-standing copper mesh resonant bandpass filters with micromachined silicon support frames. The filters are well suited for thermal mapping mission to the outer planets and their moons because the filter material is radiation hard. Furthermore, the silicon support frame allows for effective hybridization with sensors made on silicon substrates. Using a Fourier Transform Spectrometer, we have demonstrated high transmittance within the passband as well as good out-of-band rejection [1]. In addition, we have developed a unique method of filter stacking in order to increase the bandwidth and sharpen the roll-off of the filters. This method allows one to reliably control the spacing between filters to within 2 microns. Furthermore, our method allows for reliable control over the relative position and orienta-tion between the shared faces of the filters.

Brown, Ari D.↗

Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter

This innovation is a compact, superconducting, channelizing bandpass filter on a single-crystal (0.45 m thick) silicon substrate, which operates from 300 to 600 GHz. This device consists of four channels with center frequencies of 310, 380, 460, and 550 GHz, with approximately 50-GHz bandwidth per channel. The filter concept is inspired by the mammalian cochlea, which is a channelizing filter that covers three decades of bandwidth and 3,000 channels in a very small physical space. By using a simplified physical cochlear model, and its electrical analog of a channelizing filter covering multiple octaves bandwidth, a large number of output channels with high inter-channel isolation and high-order upper stopband response can be designed. A channelizing filter is a critical component used in spectrometer instruments that measure the intensity of light at various frequencies. This embodiment was designed for MicroSpec in order to increase the resolution of the instrument (with four channels, the resolution will be increased by a factor of four). MicroSpec is a revolutionary wafer-scale spectrometer that is intended for the SPICA (Space Infrared Telescope for Cosmology and Astrophysics) Mission. In addition to being a vital component of MicroSpec, the channelizing filter itself is a low-resolution spectrometer when integrated with only an antenna at its input, and a detector at each channel s output. During the design process for this filter, the available characteristic impedances, possible lumped element ranges, and fabrication tolerances were identified for design on a very thin silicon substrate. Iterations between full-wave and lumped-element circuit simulations were performed. Each channel s circuit was designed based on the availability of characteristic impedances and lumped element ranges. This design was based on a tabular type bandpass filter with no spurious harmonic response. Extensive electromagnetic modeling for each channel was performed. Four channels, with 50-GHz bandwidth, were designed, each using multiple transmission line media such as microstrip, coplanar waveguide, and quasi-lumped components on 0.45- m thick silicon. In the design process, modeling issues had to be overcome. Due to the extremely high frequencies, very thin Si substrate, and the superconducting metal layers, most commercially available software fails in various ways. These issues were mitigated by using alternative software that was capable of handling them at the expense of greater simulation time. The design of on-chip components for the filter characterization, such as a broadband antenna, Wilkinson power dividers, attenuators, detectors, and transitions has been completed.

Ehsan, Negar↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

Filtration↗

Spectral and Wavefront Error Performance of WFIRST-AFTA Bandpass Filter Coating Prototypes

The Cycle 5 design baseline for the Wide-Field Infrared Survey Telescope Astrophysics Focused Telescope Assets (WFIRST/AFTA) instrument includes a single wide-field channel (WFC) instrument for both imaging and slit-less spectroscopy. The only routinely moving part during scientific observations for this wide-field channel is the element wheel (EW) assembly. This filter-wheel assembly will have 8 positions that will be populated with 6 bandpass filters, a blank position, and a Grism that will consist of a three-element assembly to disperse the full field with an undeviated central wavelength for galaxy redshift surveys. All filter elements in the EW assembly will be made out of fused silica substrates (110 mm diameter) that will have the appropriate bandpass coatings according to the filter designations (Z087, Y106, J129, H158, F184, W149 and Grism). This paper presents and discusses the performance (including spectral transmission and reflected/transmitted wavefront error measurements) of a subset of bandpass filter coating prototypes that are based on the WFC instrument filter compliment. The bandpass coating prototypes that are tested in this effort correspond to the Z087, W149, and Grism filter elements. These filter coatings have been procured from three different vendors to assess the most challenging aspects in terms of the in-band throughput, out of band rejection (including the cut-on and cutoff slopes), and the impact the wavefront error distortions of these filter coatings will have on the imaging performance of the wide-field channel in the WFIRST/AFTA observatory.

cryogenic temperatures↗

Spectral and Wavefront Error Performance of WFIRST/AFTA Prototype Filters

The Cycle 5 design baseline for the Wide-Field Infrared Survey Telescope Astrophysics Focused Telescope Assets (WFIRSTAFTA) instrument includes a single wide-field channel (WFC) instrument for both imaging and slit-less spectroscopy. The only routinely moving part during scientific observations for this wide-field channel is the element wheel (EW) assembly. This filter-wheel assembly will have 8 positions that will be populated with 6 bandpass filters, a blank position, and a Grism that will consist of a three-element assembly to disperse the full field with an undeviated central wavelength for galaxy redshift surveys. All filter elements in the EW assembly will be made out of fused silica substrates (110 mm diameter) that will have the appropriate bandpass coatings according to the filter designations (Z087, Y106, J129, H158, F184, W149 and Grism). This paper presents and discusses the performance (including spectral transmission and reflectedtransmitted wavefront error measurements) of a subset of bandpass filter coating prototypes that are based on the WFC instrument filter compliment. The bandpass coating prototypes that are tested in this effort correspond to the Z087, W149, and Grism filter elements. These filter coatings have been procured from three different vendors to assess the most challenging aspects in terms of the in-band throughput, out of band rejection (including the cut-on and cutoff slopes), and the impact the wavefront error distortions of these filter coatings will have on the imaging performance of the de-field channel in the WFIRSTAFTA observatory.

cryogenic temperatures↗

A micromorphic filter for determining stress and deformation measures from direct numerical simulations of lower length scale behavior

A micromorphic filter is presented for the extraction of stress and deformation measures from underlying direct numerical simulation (DNS) of microstructural mechanical response. The filter is consistent with the micromorphic continuum theory of Eringen and Suhubi (1964), and allows the interrogation of a DNS to generate higher order constitutive models. The filter adopts aspects of the overlap coupling techniques for atomistic-continuum scale-bridging in order to update the nodal degrees of freedom of the finite-element-based filter. Here, two methods for the extraction of quantities of interest from the underlying DNS are presented. The first is a least squares fitting technique which is appropriate for finite-element-style macro-scale domains, and the second is a variationally based approach which generalizes the method to any macro-scale domain which has a variational form. No restrictions on the form of the micro-scale simulation are inherent to the approach, provided that the required quantities (stress, position, etc.) can be provided. The filter is applied to a simple homogeneous medium undergoing homogeneous deformation to demonstrate the recovery of a classical continuum response, what we call the null case. We then apply the framework to the same homogeneous medium with a central and edge penny-shaped crack to show micromorphic effects. We demonstrate that varying the size of the filter causes the micromorphic behaviors to arise and then dissipate as the filter becomes smaller than the crack's length scale. Additionally we show the effect of filter size on a chiral element network along with a plate perforated with evenly spaced and perturbed holes through the thickness. The micromorphic effects are shown to be present for the chiral elements under any loading but become most pronounced when a single element is located within each averaging domain. Micromorphic effects become pronounced for the plate upon the onset of localization.

97 MATHEMATICS AND COMPUTING↗

Social and Demographic Factors Influencing Inferior Vena Cava Filter Retrieval at a Single Institution in the United States

PurposeRetrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care.Materials and MethodsSeven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval.ResultsOf the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024).ConclusionsThe retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable implementation of polynomial filtering for density functional theory calculation in PARSEC

In this work, we present an efficient implementation of polynomial filtering methods in PARSEC, a real-space pseudopotential based Kohn–Sham density functional theory solver. The implementation described here improves upon a Chebyshev-filtered subspace iteration algorithm used in the previous version of PARSEC. We present a hybrid polynomial filtering scheme that combines Chebyshev-filtered subspace iteration and a spectrum slicing method that partitions the spectrum into several spectral slices and uses bandpass-filtered subspace iteration to compute approximate eigenpairs within each interior slice simultaneously. We describe a procedure to partition a spectrum and construct polynomial filters. We also discuss a number of practical issues such as the use of appropriate data layouts for carrying out the computation on a two-dimensional process grid and how to achieve good load balance by allocating an appropriate number of process groups to each spectral slice. Numerical examples are presented to demonstrate the effectiveness of the hybrid polynomial filtering method as well as the superior parallel scalability of spectrum slicing in comparison to that of Chebyshev-filtered subspace iteration.

97 MATHEMATICS AND COMPUTING↗

Joint state-parameter estimation for the reduced fracture model via the united filter

Here, in this paper, we introduce an effective United Filter method for jointly estimating the solution state and physical parameters in flow and transport problems within fractured porous media. Fluid flow and transport in fractured porous media are critical in subsurface hydrology, geophysics, and reservoir geomechanics. Reduced fracture models, which represent fractures as lower-dimensional interfaces, enable efficient multi-scale simulations. However, reduced fracture models also face accuracy challenges due to modeling errors and uncertainties in physical parameters such as permeability and fracture geometry. To address these challenges, we propose a United Filter method, which integrates the Ensemble Score Filter (EnSF) for state estimation with the Direct Filter for parameter estimation. EnSF, based on a score-based diffusion model framework, produces ensemble representations of the state distribution without deep learning. Meanwhile, the Direct Filter, a recursive Bayesian inference method, estimates parameters directly from state observations. The United Filter combines these methods iteratively: EnSF estimates are used to refine parameter values, which are then fed back to improve state estimation. Numerical experiments demonstrate that the United Filter method surpasses the state-of-the-art Augmented Ensemble Kalman Filter, delivering more accurate state and parameter estimation for reduced fracture models. This framework also provides a robust and efficient solution for PDE-constrained inverse problems with uncertainties and sparse observations.

Bayesian inference↗

Ceramic High Efficiency Particulate Air (HEPA) Filter Research and Development at Lawrence Livermore National Laboratory

Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancement of thermoelectric properties by energy filtering: Theoretical potential and experimental reality in nanostructured ZnSb

Energy filtering has been suggested by many authors as a means to improve thermoelectric properties. The idea is to filter away low-energy charge carriers in order to increase Seebeck coefficient without compromising electronic conductivity. This concept was investigated in the present paper for a specific material (ZnSb) by a combination of first-principles atomic-scale calculations, Boltzmann transport theory, and experimental studies of the same system. The potential of filtering in this material was first quantified, and it was as an example found that the power factor could be enhanced by an order of magnitude when the filter barrier height was 0.5 eV. Measured values of the Hall carrier concentration in bulk ZnSb were then used to calibrate the transport calculations, and nanostructured ZnSb with average grain size around 70 nm was processed to achieve filtering as suggested previously in the literature. Various scattering mechanisms were employed in the transport calculations and compared with the measured transport properties in nanostructured ZnSb as a function of temperature. Reasonable correspondence between theory and experiment could be achieved when a combination of constant lifetime scattering and energy filtering with a 0.25 eV barrier was employed. However, the difference between bulk and nanostructured samples was not sufficient to justify the introduction of an energy filtering mechanism. The reasons for this and possibilities to achieve filtering were discussed in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2010. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past decade, the study has now been completed, and all forty-nine HEPA filters have been replaced, due to either technical issues listed in this report, or the previously recommended filter “age limit” of 10 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cluster Sampling Filters for Non-Gaussian Data Assimilation

This paper presents a fully non-Gaussian filter for sequential data assimilation. The filter is named the &ldquo;cluster sampling filter&rdquo;, and works by directly sampling the posterior distribution following a Markov Chain Monte-Carlo (MCMC) approach, while the prior distribution is approximated using a Gaussian Mixture Model (GMM). Specifically, a clustering step is introduced after the forecast phase of the filter, and the prior density function is estimated by fitting a GMM to the prior ensemble. Using the data likelihood function, the posterior density is then formulated as a mixture density, and is sampled following an MCMC approach. Four versions of the proposed filter, namely C ℓ MCMC , C ℓ HMC , MC- C ℓ HMC , and MC- C ℓ HMC are presented. C ℓ MCMC uses a Gaussian proposal density to sample the posterior, and C ℓ HMC is an extension to the Hamiltonian Monte-Carlo (HMC) sampling filter. MC- C ℓ MCMC and MC- C ℓ HMC are multi-chain versions of the cluster sampling filters C ℓ MCMC and C ℓ HMC respectively. The multi-chain versions are proposed to guarantee that samples are taken from the vicinities of all probability modes of the formulated posterior. The new methodologies are tested using a simple one-dimensional example, and a quasi-geostrophic (QG) model with double-gyre wind forcing and bi-harmonic friction. Here, numerical results demonstrate the usefulness of using GMMs to relax the Gaussian prior assumption especially in the HMC filtering paradigm.

97 MATHEMATICS AND COMPUTING↗

Dual Extended Kalman Filter for the Identification of Time-Varying Human Manual Control Behavior

A Dual Extended Kalman Filter was implemented for the identification of time-varying human manual control behavior. Two filters that run concurrently were used, a state filter that estimates the equalization dynamics, and a parameter filter that estimates the neuromuscular parameters and time delay. Time-varying parameters were modeled as a random walk. The filter successfully estimated time-varying human control behavior in both simulated and experimental data. Simple guidelines are proposed for the tuning of the process and measurement covariance matrices and the initial parameter estimates. The tuning was performed on simulation data, and when applied on experimental data, only an increase in measurement process noise power was required in order for the filter to converge and estimate all parameters. A sensitivity analysis to initial parameter estimates showed that the filter is more sensitive to poor initial choices of neuromuscular parameters than equalization parameters, and bad choices for initial parameters can result in divergence, slow convergence, or parameter estimates that do not have a real physical interpretation. The promising results when applied to experimental data, together with its simple tuning and low dimension of the state-space, make the use of the Dual Extended Kalman Filter a viable option for identifying time-varying human control parameters in manual tracking tasks, which could be used in real-time human state monitoring and adaptive human-vehicle haptic interfaces.

manual control↗

Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗