Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Ares I-X Ground Diagnostic Prototype

The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

Schwabacher, Mark A.↗

Shielded-Twisted-Pair Cable Model for Chafe Fault Detection via Time-Domain Reflectometry

This report details the development, verification, and validation of an innovative physics-based model of electrical signal propagation through shielded-twisted-pair cable, which is commonly found on aircraft and offers an ideal proving ground for detection of small holes in a shield well before catastrophic damage occurs. The accuracy of this model is verified through numerical electromagnetic simulations using a commercially available software tool. The model is shown to be representative of more realistic (analytically intractable) cable configurations as well. A probabilistic framework is developed for validating the model accuracy with reflectometry data obtained from real aircraft-grade cables chafed in the laboratory.

Schuet, Stefan R.↗

Physics Based Model for Online Fault Detection in Autonomous Cryogenic Loading System

We report the progress in the development of the chilldown model for rapid cryogenic loading system developed at KSC. The nontrivial characteristic feature of the analyzed chilldown regime is its active control by dump valves. The two-phase flow model of the chilldown is approximated as one-dimensional homogeneous fluid flow with no slip condition for the interphase velocity. The model is built using commercial SINDAFLUINT software. The results of numerical predictions are in good agreement with the experimental time traces. The obtained results pave the way to the application of the SINDAFLUINT model as a verification tool for the design and algorithm development required for autonomous loading operation.

Cryogenics↗

Battery Fault Detection with Saturating Transformers

A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.

Davies, Francis J.↗

Method of Fault Detection and Rerouting

A system and method for detecting damage in an electrical wire, including delivering at least one test electrical signal to an outer electrically conductive material in a continuous or non-continuous layer covering an electrically insulative material layer that covers an electrically conductive wire core. Detecting the test electrical signals in the outer conductive material layer to obtain data that is processed to identify damage in the outer electrically conductive material layer.

Medelius, Pedro J.↗

Hybrid Modeling of Unmanned Aerial Vehicle Electric Powertrain for Fault Detection and Diagnostics

This paper shows the application of hybrid physics-informed machine learning to a representative electric powertrain for unmanned aerial vehicles. The model is composed of physics-derived principles and empirical equations, as well as fully connected networks that are strategically placed within the model to substitute equations that are subject to large uncertainty. Polynomial fit driven by heuristics or empirical observations can be substituted by more flexible networks that can minimize the error between model predictions and observations without being restricted to a predefined functional form. This modeling strategy allows training of networks deep inside the model and unknown parameters in a single learning stage. It has already been applied to Li-ion batteries in the past, and in this work, we extend the applications to other components of an electric powertrain, namely electronic speed controller with pulse-width modulation, and brushless DC motor with connected propeller. Training and testing of the model is carried out using experimental data from Li-ion battery discharge and powertrain testing in a laboratory environment.

Physics-Informed Machine Learning↗

Model Based Approaches for Fault Detection, Prognostics, Decision Making in Complex Systems

The presentation discusses application of model based approaches to complex systems. The model is composed of physics-derived and empirical equations, integrated with connected networks that are strategically placed within the model to substitute equations that are subject to large uncertainty. Polynomial fit driven by heuristics or empirical observations can be substituted by more flexible networks that can minimize the error between model predictions and observations without being restricted to a predefined functional form. This modeling strategy allows training of networks deep inside the model and unknown parameters in a single learning stage.

Physics Informed↗

Fault Detection in the Solvent Extraction Process with Non-traditional Sensors

Solvent extraction is used to separate metals or other complexes into two different immiscible liquids and is an essential component of the PUREX Process. Improvements to the solvent extraction process can directly contribute to an organization’s ability to ensure the purity and recovery of special nuclear materials from spent nuclear fuel. Such improvements can benefit nuclear reprocessing efforts, increase fuel reutilization, and limit the concentration of actinides in nuclear waste repositories.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Parameter Transient Behavior Analysis on Fault Tolerant Control System

In a fault tolerant control (FTC) system, a parameter varying FTC law is reconfigured based on fault parameters estimated by fault detection and isolation (FDI) modules. FDI modules require some time to detect fault occurrences in aero-vehicle dynamics. This paper illustrates analysis of a FTC system based on estimated fault parameter transient behavior which may include false fault detections during a short time interval. Using Lyapunov function analysis, the upper bound of an induced-L2 norm of the FTC system performance is calculated as a function of a fault detection time and the exponential decay rate of the Lyapunov function.

Belcastro, Christine↗