SOSAT: Geohazard Risk Assessment in Carbon Sequestration Operations

Like all operations in which fluids are injected into the subsurface, geologic carbon storage (GCS) presents inherit risks that must be assessed and mitigated to successfully deploy such technology in the field. For example, alterations to pore pressure and the stress state due to fluid injection may trigger certain geohazards, such as potential fault activation and induced seismicity or unintentional hydraulic fracturing. Here we present capabilities for assessing these potential risks using the State of Stress Analysis Tool (SOSAT): a Python library and web-based application capable of probabilistically estimating the subsurface state of stress informed by various field observations. Using posterior distributions of principal stress components, SOSAT can assess the risk of fault activation within the injection formation for either a critically oriented fault or a fault with a user-prescribed orientation. Additionally, SOSAT can estimate the probability of unintentional hydraulic fracturing of the intact reservoir rock. Here, we demonstrate these SOSAT capabilities using a hypothetical GCS site. This type of risk assessment can assist with the effective deployment of GCS technology in the field by informing safe design and management practices.

Haagenson, Ryan J.↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

EQSIM—A multidisciplinary framework for fault-to-structure earthquake simulations on exascale computers part I: Computational models and workflow

Computational simulations have become central to the seismic analysis and design of major infrastructure over the past several decades. Most major structures are now “proof tested” virtually through representative simulations of earthquake-induced response. More recently, with the advancement of high-performance computing (HPC) platforms and the associated massively parallel computational ecosystems, simulation is beginning to play a role in increased understanding and prediction of ground motions for earthquake hazard assessments. However, the computational requirements for regional-scale geophysics-based ground motion simulations are extreme, which has restricted the frequency resolution of direct simulations and limited the ability to perform the large number of simulations required to numerically explore the problem parametric space. In this article, recent developments toward an integrated, multidisciplinary earth science-engineering computational framework for the regional-scale simulation of both ground motions and resulting structural response are described with a particular emphasis on advancing simulations to frequencies relevant to engineered systems. This multidisciplinary computational development is being carried out as part of the US Department of Energy (DOE) Exascale Computing Project with the goal of achieving a computational framework poised to exploit emerging DOE exaflop computer platforms scheduled for the 2022–2023 timeframe.

58 GEOSCIENCES↗

Forward and inverse modeling of fault transmissibility in subsurface flows

Characterizing physical properties of faults, such as their transmissibility, is crucial for performing predictive numerical simulation of subsurface flows, such as those encountered in petroleum engineering and remediation of subsurface contamination. Here, this paper provides a complete investigation of the inverse problem for fault transmissibility in subsurface flow models, under appropriate assumptions on fault structure. In particular, the following aspects are considered: 1) fault modeling and well-posedness of the forward problem; 2) finite element (FEM) discretizations of the forward problem and their rigorous a priori convergence analysis; 3) Well-posedness of the Bayesian inverse problem, FEM discretization of the infinite dimensional Bayesian inverse formulation, and its rigorous a priori analysis. Moreover, computation of the maximum a posteriori (MAP) point via fast inexact Newton-conjugate gradient optimization and a Laplace approximation of the Bayesian posterior are also presented. Numerical results illustrate the use of the proposed fault model in forward and inverse problems for subsurface flows in two dimensional domains with multiple faults.

97 MATHEMATICS AND COMPUTING↗

MASTODON: An Open-Source Software for Seismic Analysis and Risk Assessment of Critical Infrastructure

Seismic analysis and risk assessment of safety-critical infrastructure like hospitals, nuclear power plants, dams, and facilities handling radioactive materials involve computationally intensive numerical models and coupled multiphysics scenarios. They are also performed in a strict regulatory environment that requires high software quality assurance standards, and in the case of safety-related nuclear facilities, a conformance to the American Society of Mechanical Engineers Nuclear Quality Assurance (NQA-1) standard. This paper introduces the open-source finite-element software, MASTODON (Multi-hazard Analysis of Stochastic Time-Domain Phenomena), which implements state-of-the-art seismic analysis and risk assessment tools in a quality-controlled environment. MASTODON is built on MOOSE (Multi-physics Object-Oriented Simulation Environment), which is a highly parallelizable, NQA-1 conforming, coupled multiphysics, finite-element framework developed at Idaho National Laboratory. MASTODON is capable of fault rupture and source-to-site wave propagation using the domain reduction method, nonlinear site response, and soil-structure interaction analysis, implicit and explicit time integration, automated stochastic simulations, and seismic probabilistic risk assessment. When coupled with other MOOSE applications, MASTODON can also solve strongly and weakly coupled multiphysics problems. This paper presents a summary of the capabilities of MASTODON and some demonstrative examples.

42 ENGINEERING↗

Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

DC Circuit Breakers: A Technology Development Status Survey

DC circuit breakers (DCCBs) play a significant role in obtaining the reliability and stability of DC power systems. Selective and fast isolating of faults minimizes the power supply outages to end electricity users and protects the power converters implemented in the DC system. During the last decades, DCCBs have been deeply investigated in industry and academia. There has been impressive progress in terms of efficiency, response time, power-density, lifetime, and electrical operating ratings. Introducing wide bandgap (WBG) devices further has motivated researchers to propose more efficient and novel topologies. This paper provides a point of reference and a background review for DCCBs from novel aspects, fulfilling absent parts in the literature. The elaborated subjects include current commutation circuitry, DCCBs trip-curves developments, newly added functions to DCCBs, as well as marketing analysis. The advancements of DCCBs are surveyed and development needs are recognized. This paper aims to identify the future research needs of DCCBs for emerging DC power systems.

42 ENGINEERING↗

Stochastic Fault Detection

This entry describes the state-of-the-art and future perspectives on stochastic fault detection, namely, stochastic fault detection and diagnosis (FDD). Both model-based and data-driven FDD methods for stochastic signals and systems have been included, where the use of hypothesis testing, Kalman filtering, system estimation, principal component analysis (PCA), and stochastic distribution control has been discussed for the construction of effective FDD algorithms. Indeed, stochastic FDD constitute an important and integrated part in developing fault-tolerant controls (FTC) for guaranteed safe operation of control systems, of which increased penetration of random factors is inevitable nowadays.

Wang, Aiping↗

Subsurface Characterization and Machine Learning Predictions at Brady Hot Springs: Preprint

Subsurface data analysis, reservoir modeling, and machine learning (ML) techniques have been applied to the Brady Hot Springs (BHS) geothermal field in Nevada, USA to further characterize the subsurface and assist with optimizing reservoir management. Hundreds of reservoir simulations have been conducted in TETRAD-G and CMG STARS to explore different injection and production fluid flow rates and allocations and to develop a training data set for ML. This process included simulating the historical injection and production since 1979 and prediction of future performance through 2040. ML networks were created and trained using TensorFlow based on multilayer perceptron (MLP), long short-term memory (LSTM), and convolutional neural network (CNN) architectures. These networks took as input selected flow rates, injection temperatures, and historical field operation data and produced estimates of future production temperatures. This approach was first successfully tested on a simplified single fracture doublet system, followed by the application to the BHS reservoir. Using an initial BHS dataset with 37 simulated scenarios, the trained and validated network predicted the production temperature for 6 production wells with the mean absolute percentage error of less than 8%. In a complementary analysis effort, the principal component analysis applied to 13 BHS geological parameters revealed that vertical fracture permeability shows the strongest correlation with fault density and fault intersection density. A new BHS reservoir model was developed considering the fault intersection density as proxy for permeability. This new reservoir model helps to explore under-exploited zones in the reservoir. A data gathering plan to obtain additional subsurface data was developed; it includes temperature surveying for three idle injection wells, at which the reservoir simulations indicate high bottom-hole temperatures. The collected data assist with calibrating the reservoir model and may lead to converting these wells to producers to access under-exploited zones in the reservoir. Data gathering activities are planned for the first quarter of 2021.

40 EE - Geothermal Technologies Office (EE-4G)↗

Line Faults Classification Using Machine Learning on Three Phase Voltages Extracted from Large Dataset of PMU Measurements

An end-to-end supervised learning method is developed to classify transmission line faults in a twoyear field-recorded dataset that includes synchronized measurements of three-phase voltages recorded by 38 Phasor Measurement Units (PMU) sparsely located in in the US Western Grid interconnection. Statistical analysis is performed to extract features from this large dataset to train Support Vector Machine (SVM), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) classifiers initially. The training further leverages a simulated dataset from a synthetic grid with 12 PMUs to increase the number of faults of types infrequently seen in the field-recorded dataset. Training the classification models with the combined dataset resulted in a classification accuracy of 97.7%. This is a significant improvement over 89.7% to 92.5% accuracy obtained by relying on the field-recorded dataset alone.

47 OTHER INSTRUMENTATION↗

Local chemical ordering of a neutron-irradiated CrFeMnNi compositionally complex alloy

While ion-irradiation studies are a critical first step in studying compositionally complex alloys (CCAs) for nuclear applications, they do not capture all the microstructural changes occurring under the low irradiation dose rates and different particles’ scattering patterns experienced in a nuclear reactor setting. To explore these phenomena in reactor-relevant conditions for the first time in CCA, the single-phase solid-solution Cr 10 Fe 30 Mn 30 Ni 30 was neutron irradiated up to 6.61 displacements per atom at 395 and 579 °C. Irradiation-enhanced local chemical ordering (LCO) well beyond the range of short range ordering was observed, and is predicted to be the precursor to the precipitation of a coherent Ni-Mn L1 0 phase and a Cr-rich α’ phase, though TEM analysis did not indicate the presence of either in any irradiation condition. The line density of faulted dislocation loops decreased from 6.47 to 1.69 ∙ 10 15 m -2 from 3.43 to 6.61 dpa at 579 °C despite no appreciable faulted loop content in the unirradiated material. LCO is expected to increase the complexity of the energy landscape within this alloy, restricting interstitial point defect mobility and creating local regions of greater stacking fault energy. These contribute to the negative correlation between irradiation dose and faulted dislocation loop density in this study, as well as the lack of void swelling observed.

36 MATERIALS SCIENCE↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Shallow Geothermal Potential of the Snake River Plain

The Snake River Plain (SRP) terrestrial heat flow and subsurface thermal regime are not well understood but are important for assessing the local geothermal resource potential, both for conventional and for Enhanced Geothermal Systems (EGS) development in the region. Resource evaluation for the SRP is complicated by the disparate data density, along with the known lateral advection of heat in the Eastern Snake River Plain Aquifer and vertical heat transport by fluids in the bounding faults, primarily in the southwestern section. Fortunately, recent studies, e.g., the Snake River Plain Play Fairway Analysis, the Idaho FORGE site, and site-specific investigations, which included drilling within the Camas Prairie and on the Mountain Home Air Force Base, near Twin Falls, and in the Eastern Snake River Plain as part of the HOTSPOT Project, add both additional drilling and geophysical data. The SMU Geothermal Laboratory has conducted detailed studies of SRP tectonics and heat flow since the 1970's and used this knowledge as part of the EGS geothermal potential estimation for the conterminous United States in 2006 and again in 2011, calculating geothermal potential from 3.5 km to 10 km depth. Recent temperature modeling refined the calculation methodology to estimate shallow (1 km to 4 km) resource potential using an improved thermal conductivity model and incorporation of shallow groundwater flow. By incorporating the new SRP geology, geophysics, and 206 thermal data sites into the SMU thermal modeling methodology, this project updates the resource estimate for the SRP, and generates new temperature-at-depth maps for the shallow subsurface (1 km to 4 km). The project results highlight the EGS potential resource areas (=150°C) and areas with more exploration risks based on minimal and/or low-quality data. The newest temperature modeling results suggest EGS potential is near five times greater in the SRP than previously estimated.

EGS↗

Mitigating Injection‐Induced Seismicity Along Basement Faults by Extraction: Application to 2016–2018 Pohang Earthquakes

Abstract The risk of induced earthquake is considered as the major obstacle for sustainable subsurface energy activities. As a mitigation approach, mechanistic risk assessment can be essential to minimize the potential of seismic hazard. Coupled hydro‐mechanical modeling approach is integrated with geomechanical analysis to better assess the occurrence of seismicity induced by injection and/or extraction, which will provide a basis to update operational conditions (e.g., number and location of mitigating wells, rate and duration of operations) for mitigating earthquake nucleation. The Coulomb stability analysis and seismicity rate estimates from this generic study indicate that simultaneous extraction can relieve injection‐induced pore‐pressure buildup, but also transfer and accumulate elastic energy along the faults. Field‐scale simulation with variation in well design for the Pohang EGS site, South Korea, show that multiple wells aligned across a preexisting fault form gradients of pressure and stress fields normal to the fault, which can enhance the direct impact of diffusion process and poroelastic stressing on the fault stability perturbation. Our mechanistic study suggests multiphysics‐oriented mitigation strategies that consider (1) possible mechanical deformation, caused by hydro‐mechanical coupling effects, and (2) proper configuration of well operations based on site‐specific geological characteristics.

Chang, K. W.↗