pyFLANK, a graph neural network based null distribution inference model for F ST outlier detection

Detecting genomic regions under selection is essential for understanding how populations adapt to different environments, yet it remains challenging due to the confounding effects of demographic history and linkage disequilibrium (LD). Fixation index (F ST ) is a widely used statistic to identify genomic regions under adaptation. However, identifying genes under selection by defining F ST outliers often remains challenging, owing to confounding effects of underlying demographic history. Traditional methods assume independence among loci and rely on simple demographic models, while newer models perform much better but are computationally expensive and not easily scalable. Here, we present pyFLANK, an open-source and automated Python implementation which detects F ST outliers using a null distribution inferred from quasi-independent loci. Our tool integrates three approaches to identify loci obeying a null distribution: graph neural network (GNN) inference, linkage disequilibrium (LD)-based inference, and user-defined input. Because pyFLANK uses GNN-based inference of quasi-independent loci, it yields a more accurate null model with less need for user parameter input. In simulation experiments, pyFLANK achieved lower false positive rates than current methods while maintaining comparable detection power, indicating that its refined null model better distinguishes true adaptive loci from background variation. The GNN-based model, in particular, detected additional loci associated with phenotypic variance that were not identified by existing methods. Assessments of simulation and real data from different species demonstrate that pyFLANK achieves lower false positive rates compared with other commonly used F ST outlier detectors, while maintaining comparable detection power and excellent computational performance, providing a robust and user-friendly tool for identifying loci under divergent selection. It extends existing F ST outlier frameworks by incorporating explicit LD-aware strategies for null model calibration. The method is intended as a practical and scalable complement to existing genome scan approaches.

FST↗

PRESAGE: Protecting Structured Address Generation against Soft Errors

Modern computer scaling trends in pursuit of larger component counts and power efficiency have, unfortunately, lead to less reliable hardware and consequently soft errors escaping into application data ("silent data corruptions"). Techniques to enhance system resilience hinge on the availability of efficient error detectors that have high detection rates, low false positive rates, and lower computational overhead. Unfortunately, efficient detectors to detect faults during address generation (to index large arrays) have not been widely researched. We present a novel lightweight compiler-driven technique called PRESAGE for detecting bit-flips affecting structured address computations. A key insight underlying PRESAGE is that any address computation scheme that flows an already incurred error is better than a scheme that corrupts one particular array access but otherwise (falsely) appears to compute perfectly. Enabling the flow of errors allows one to situate detectors at loop exit points, and helps turn silent corruptions into easily detectable error situations. Our experiments using PolyBench benchmark suite indicate that PRESAGE-based error detectors have a high error-detection rate while incurring low overheads.

Sharma, Vishal C.↗

Radiation Changes Do Not Interfere With Postchemoradiation Restaging of Patients With Rectal Cancer by FDG PET/CT Before Curative Surgical Therapy

Purpose: Changes in F-18 fluorodeoxyglucose (FDG) uptake in normal tissues after chemoradiation therapy (CRT) potentially limit the ability of positron emission tomography (PET) to provide early assessment of therapeutic response. This study evaluated whether such changes negatively impact interpretation of posttherapy PET performed within 6 weeks of CRT completion and before definitive surgery in patients with locally advanced rectal cancer. The positive predictive value (PPV) and specificity of post-CRT PET, read clinically, was determined in 63 consecutive rectal cancer patients who had undergone preoperative CRT. Methods and Materials: A schema for identifying and scoring postradiation effects on PET was prospectively defined and applied in a blinded manner. This was compared with initial clinical reporting of response. Histologic assessment of the operative specimens was used as the reference standard. Correlation between clinical proctitis during CRT and radiation changes on subsequent PET was also assessed. Results: Clinical reporting of post-CRT PET yielded a high PPV (94%; 95% confidence interval, 89--100%) but may have been exaggerated by the low prevalence of complete tumor clearance (16%). The specificity was 80% with only two false-positive results. On blinded reading, significant post-CRT effects on PET were recorded in 4 of 63 patients (6% 95% confidence interval, 0-13%), but pattern recognition converted both false-positive PET results to a complete metabolic response. Clinical CRT proctitis was not correlated with PET findings. Conclusion: Postradiation effects do not appear to significantly compromise the interpretation of PET for therapeutic response assessment. The proposed PET pattern of response may further improve the specificity of PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyper Spectral Anomaly Detection

Anomaly detection is a common machine learning (ML) task with growing importance in the fields of imaging, quality assurance, and multiple security related disciplines. Anomaly detection is more difficult than traditional machine learning methods due to the inherent unlabeled nature of the datasets. Existing anomaly detection architectures commonly face challenges with explainability, retaining information related to the relational structure of the data, and false positive rates. Hyperspectral Imaging Anomaly Detection (HSI) is a statistical model that employs vertex and edge weighted graphs to preserve the data’s relationships on different topographical scales. The model is able to generalize from anomaly detection in 2D images to novel datasets related to cyber-security. Furthermore, the use of multi-spectral and other filtering methods results in fewer false positives and increases the explainability of model predictions. When applying HSI to cyber-security datasets, we are able to successfully detect malicious activity with a relatively high degree of accuracy.

97 - MATHEMATICS AND COMPUTING↗

KEPLER-20: A SUN-LIKE STAR WITH THREE SUB-NEPTUNE EXOPLANETS AND TWO EARTH-SIZE CANDIDATES

We present the discovery of the Kepler-20 planetary system, which we initially identified through the detection of five distinct periodic transit signals in the Kepler light curve of the host star 2MASS J19104752+4220194. From high-resolution spectroscopy of the star, we find a stellar effective temperature T{sub eff} = 5455 {+-} 100 K, a metallicity of [Fe/H] = 0.01 {+-} 0.04, and a surface gravity of log g = 4.4 {+-} 0.1. We combine these estimates with an estimate of the stellar density derived from the transit light curves to deduce a stellar mass of M{sub *} = 0.912 {+-} 0.034 M{sub Sun} and a stellar radius of R{sub *} = 0.944{sup +0.060}{sub -0.095} R{sub Sun }. For three of the transit signals, we demonstrate that our results strongly disfavor the possibility that these result from astrophysical false positives. We accomplish this by first identifying the subset of stellar blends that reproduce the precise shape of the light curve and then using the constraints on the presence of additional stars from high angular resolution imaging, photometric colors, and the absence of a secondary component in our spectroscopic observations. We conclude that the planetary scenario is more likely than that of an astrophysical false positive by a factor of 2 Multiplication-Sign 10{sup 5} (Kepler-20b), 1 Multiplication-Sign 10{sup 5} (Kepler-20c), and 1.1 Multiplication-Sign 10{sup 3} (Kepler-20d), sufficient to validate these objects as planetary companions. For Kepler-20c and Kepler-20d, the blend scenario is independently disfavored by the achromaticity of the transit: from Spitzer data gathered at 4.5 {mu}m, we infer a ratio of the planetary to stellar radii of 0.075 {+-} 0.015 (Kepler-20c) and 0.065 {+-} 0.011 (Kepler-20d), consistent with each of the depths measured in the Kepler optical bandpass. We determine the orbital periods and physical radii of the three confirmed planets to be 3.70 days and 1.91{sup +0.12}{sub -0.21} R{sub Circled-Plus} for Kepler-20b, 10.85 days and 3.07{sup +0.20}{sub -0.31} R{sub Circled-Plus} for Kepler-20c, and 77.61 days and 2.75{sup +0.17}{sub -0.30} R{sub Circled-Plus} for Kepler-20d. From multi-epoch radial velocities, we determine the masses of Kepler-20b and Kepler-20c to be 8.7 {+-} 2.2 M{sub Circled-Plus} and 16.1 {+-} 3.5 M{sub Circled-Plus }, respectively, and we place an upper limit on the mass of Kepler-20d of 20.1 M{sub Circled-Plus} (2{sigma}).

79 ASTRONOMY AND ASTROPHYSICS↗

A system to detect cerebral aneurysms in multimodality angiographic data sets

Purpose: The early detection of cerebral aneurysms plays a major role in preventing subarachnoid hemorrhage. The authors present a system to automatically detect cerebral aneurysms in multimodal 3D angiographic data sets. The authors’ system is parametrizable for contrast-enhanced magnetic resonance angiography (CE-MRA), time-of-flight magnetic resonance angiography (TOF-MRA), and computed tomography angiography (CTA). Methods: Initial volumes of interest are found by applying a multiscale sphere-enhancing filter. Several features are combined in a linear discriminant function (LDF) to distinguish between true aneurysms and false positives. The features include shape information, spatial information, and probability information. The LDF can either be parametrized by domain experts or automatically by training. Vessel segmentation is avoided as it could heavily influence the detection algorithm. Results: The authors tested their method with 151 clinical angiographic data sets containing 112 aneurysms. The authors reach a sensitivity of 95% with CE-MRA data sets at an average false positive rate per data set (FP{sub DS}) of 8.2. For TOF-MRA, we achieve 95% sensitivity at 11.3 FP{sub DS}. For CTA, we reach a sensitivity of 95% at 22.8 FP{sub DS}. For all modalities, the expert parametrization led to similar or better results than the trained parametrization eliminating the need for training. 93% of aneurysms that were smaller than 5 mm were found. The authors also showed that their algorithm is capable of detecting aneurysms that were previously overlooked by radiologists. Conclusions: The authors present an automatic system to detect cerebral aneurysms in multimodal angiographic data sets. The system proved as a suitable computer-aided detection tool to help radiologists find cerebral aneurysms.

60 APPLIED LIFE SCIENCES↗

DETECTABILITY OF TRANSITING JUPITERS AND LOW-MASS ECLIPSING BINARIES IN SPARSELY SAMPLED PAN-STARRS-1 SURVEY DATA

We present detailed simulations of the Pan-STARRS-1 (PS1) multi-epoch, multiband 3pi Survey in order to assess its potential yield of transiting planets and eclipsing binaries. This survey differs from dedicated transit surveys in that it will cover the entire northern sky but provide only sparsely sampled light curves. Since most eclipses would be detected at only a single epoch, the 3pi Survey will be most sensitive to deep eclipses (approx>0.10 mag) caused by Jupiters transiting M dwarfs and eclipsing stellar/substellar binaries. The survey will measure parallaxes for the approx4 x 10{sup 5} stars within 100 pc, which will enable a volume-limited eclipse search, reducing the number of astrophysical false positives compared with previous magnitude-limited searches. Using the best available empirical data, we constructed a model of the extended solar neighborhood that includes stars, brown dwarfs, and a realistic binary population. We computed the yield of deeply eclipsing systems using both a semianalytic and a full Monte Carlo approach. We examined statistical tests for detecting single-epoch eclipses in sparsely sampled data and assessed their vulnerability to false positives due to stellar variability. Assuming a short-period planet frequency of 0.5% for M dwarfs, our simulations predict that about a dozen transiting Jupiters around low-mass stars (M {sub *} < 0.3 M {sub sun}) within 100 pc are potentially detectable in the PS1 3pi Survey, along with approx300 low-mass eclipsing binaries (both component masses <0.5 M {sub sun}), including approx10 eclipsing field brown dwarfs. Extensive follow-up observations would be required to characterize these candidate eclipsing systems, thereby enabling comprehensive tests of structural models and novel insights into the planetary architecture of low-mass stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic detection of ship-induced cloud features in satellite imagery

Ships crossing the ocean are known to produce long, curvilinear features called ship tracks visible in satellite imagery via the Twomey effect; however, there has been little exploitation of satellite imagery for broad atmospheric studies or global monitoring of ship emissions due to the difficulty of automated ship track detection. Prior studies are either proof-of-concept, qualitatively assessed, or restricted to a certain time of day. We propose a statistical method for the automated identification of ship tracks and demonstrate using GOES-West ABI data. We first present a human-assisted segmentation method, which we use to generate a ground truth data set of 529 annotated ship tracks in GOES-West ABI products. We then describe a two-stage automated approach comprising a detection stage to generate ship track proposals and a classification stage to reduce false positives. For detection, we present a novel pipeline based around a z-score filtering technique, and for classification, we demonstrate several classifiers from literature. In a final experiment, we quantitatively tune the detection parameters and train the classifier using the ground truth dataset, then test on a sequestered set of images; the detect-then-classify system had an overall Pd of 0.68 and 0.80 for daytime and nighttime data, respectively, and the classifier reduced false positive detections by 67% and 75%.

47 OTHER INSTRUMENTATION↗

VALIDATION OF 12 SMALL KEPLER TRANSITING PLANETS IN THE HABITABLE ZONE

We present an investigation of 12 candidate transiting planets from Kepler with orbital periods ranging from 34 to 207 days, selected from initial indications that they are small and potentially in the habitable zone (HZ) of their parent stars. Few of these objects are known. The expected Doppler signals are too small to confirm them by demonstrating that their masses are in the planetary regime. Here we verify their planetary nature by validating them statistically using the BLENDER technique, which simulates large numbers of false positives and compares the resulting light curves with the Kepler photometry. This analysis was supplemented with new follow-up observations (high-resolution optical and near-infrared spectroscopy, adaptive optics imaging, and speckle interferometry), as well as an analysis of the flux centroids. For 11 of them (KOI-0571.05, 1422.04, 1422.05, 2529.02, 3255.01, 3284.01, 4005.01, 4087.01, 4622.01, 4742.01, and 4745.01) we show that the likelihood they are true planets is far greater than that of a false positive, to a confidence level of 99.73% (3σ) or higher. For KOI-4427.01 the confidence level is about 99.2% (2.6σ). With our accurate characterization of the GKM host stars, the derived planetary radii range from 1.1 to 2.7 R {sub ⊕}. All 12 objects are confirmed to be in the HZ, and nine are small enough to be rocky. Excluding three of them that have been previously validated by others, our study doubles the number of known rocky planets in the HZ. KOI-3284.01 (Kepler-438b) and KOI-4742.01 (Kepler-442b) are the planets most similar to the Earth discovered to date when considering their size and incident flux jointly.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Hidden Markov Model: a shortest unique representative approach to detect the protein toxins, virulence factors and antibiotic resistance genes

Objective: Currently, next generation sequencing (NGS) is widely used to decode potential novel or variant pathogens both in emergent outbreaks and in routine clinical practice. However, the efficient identification of novel or diverged pathogenomic compositions remains a big challenge. It is especially true for short DNA sequence fragments from NGS, since sequence similarity searching is vulnerable to false negatives or false positives, as is mismatching or matching with unrelated proteins. Therefore, this study aimed to establish a bioinformatics approach that can generate unique motif sequences for profiling searching, resulting in high specificity and sensitivity. Results: In this study, we introduced a Shortest Unique Representative Hidden Markov Model (HMM) approach to identify bacterial toxin, virulence factor (VF), and antimicrobial resistance (AR) in short sequence reads. We first construct unique representative domain sequences of toxin genes, VFs, and ARs to avoid potential false positives, and then to use HMM models to accurately identify potential toxin, VF, and AR fragments. The benchmark shows this approach can achieve relatively high specificity and sensitivity if the appropriate cutoff value is applied. Our approach can be used to recognize the protein sequences of known toxins and pathogens, identifies their common characteristics and then searches for similar sequences in other organisms.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution multi-band imaging for validation and characterization of small Kepler planets

High-resolution ground-based optical speckle and near-infrared adaptive optics images are taken to search for stars in close angular proximity to host stars of candidate planets identified by the NASA Kepler Mission. Neighboring stars are a potential source of false positive signals. These stars also blend into Kepler light curves, affecting estimated planet properties, and are important for an understanding of planets in multiple star systems. Deep images with high angular resolution help to validate candidate planets by excluding potential background eclipsing binaries as the source of the transit signals. A study of 18 Kepler Object of Interest stars hosting a total of 28 candidate and validated planets is presented. Validation levels are determined for 18 planets against the likelihood of a false positive from a background eclipsing binary. Most of these are validated at the 99% level or higher, including five newly validated planets in two systems: Kepler-430 and Kepler-431. The stellar properties of the candidate host stars are determined by supplementing existing literature values with new spectroscopic characterizations. Close neighbors of seven of these stars are examined using multi-wavelength photometry to determine their nature and influence on the candidate planet properties. Most of the close neighbors appear to be gravitationally bound secondaries, while a few are best explained as closely co-aligned field stars. Revised planet properties are derived for each candidate and validated planet, including cases where the close neighbors are the potential host stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Process prediction and detection of faults using probabilistic bidirectional recurrent neural networks on real plant data

Attaining Industry 4.0 for manufacturing operations requires advanced monitoring systems and real-time data analytics of plant data, among other topics. We propose a Probabilistic Bidirectional Recurrent Network (PBRN) for industrial process monitoring for the early detection of faults. The model is based on a Gated Recurrent Unit (GRU) neural network that allows the model to retain long-term dependencies between sensor data along a time horizon, hence learning the dynamic behavior of the process. To reduce the false-positive detection rate of the model, we compel the model to learn from a highly noisy sensor reading while outputting noise-free sensor outputs. The performance of the proposed model is compared to other data-driven statistical process monitoring schemes using real plant data from an industrial Air Separations Unit (ASU) containing noisy sensor readings. We show that the model can learn from noisy data without reducing its performance. Using two different fault cases, we demonstrate the model’s ability to carry out early fault detection with average false-positive rates of 2.9% and 4.9% for both fault cases. The missed detection rates are 0.1% and 0.2%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN EFFICIENT AUTOMATED VALIDATION PROCEDURE FOR EXOPLANET TRANSIT CANDIDATES

Surveys searching for transiting exoplanets have found many more candidates than they have been able to confirm as true planets. This situation is especially acute with the Kepler survey, which has found over 2300 candidates but has to date confirmed only a small fraction of them as planets. I present here a general procedure that can quickly be applied to any planet candidate to calculate its false positive probability. This procedure takes into account the period, depth, duration, and shape of the signal; the colors of the target star; arbitrary spectroscopic or imaging follow-up observations; and informed assumptions about the populations and distributions of field stars and multiple-star properties. Applying these methods to a sample of known Kepler planets, I demonstrate that many signals can be validated with very limited follow-up observations: in most cases with only a spectrum and an adaptive optics image. Additionally, I demonstrate that this procedure can reliably identify false positive signals. Because of the computational efficiency of this analysis, it is feasible to apply it to all Kepler planet candidates in the near future, and it will streamline the follow-up efforts for Kepler and other current and future transit surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Mixture-Tuned, Clutter Matched Filter for Remote Detection of Subpixel Spectral Signals

Mapping localized spectral features in large images demands sensitive and robust detection algorithms. Two aspects of large images that can harm matched-filter detection performance are addressed simultaneously. First, multimodal backgrounds may thwart the typical Gaussian model. Second, outlier features can trigger false detections from large projections onto the target vector. Two state-of-the-art approaches are combined that independently address outlier false positives and multimodal backgrounds. The background clustering models multimodal backgrounds, and the mixture tuned matched filter (MT-MF) addresses outliers. Combining the two methods captures significant additional performance benefits. The resulting mixture tuned clutter matched filter (MT-CMF) shows effective performance on simulated and airborne datasets. The classical MNF transform was applied, followed by k-means clustering. Then, each cluster s mean, covariance, and the corresponding eigenvalues were estimated. This yields a cluster-specific matched filter estimate as well as a cluster- specific feasibility score to flag outlier false positives. The technology described is a proof of concept that may be employed in future target detection and mapping applications for remote imaging spectrometers. It is of most direct relevance to JPL proposals for airborne and orbital hyperspectral instruments. Applications include subpixel target detection in hyperspectral scenes for military surveillance. Earth science applications include mineralogical mapping, species discrimination for ecosystem health monitoring, and land use classification.

Thompson, David R.↗

Lead discovery for mammalian elongation of long chain fatty acids family 6 using a combination of high-throughput fluorescent-based assay and RapidFire mass spectrometry assay

A high-throughput RapidFire mass spectrometry assay is described for elongation of very long-chain fatty acids family 6 (Elovl6). Elovl6 is a microsomal enzyme that regulates the elongation of C12-16 saturated and monounsaturated fatty acids. Elovl6 may be a new therapeutic target for fat metabolism disorders such as obesity, type 2 diabetes, and nonalcoholic steatohepatitis. To identify new Elovl6 inhibitors, we developed a high-throughput fluorescence screening assay in 1536-well format. However, a number of false positives caused by fluorescent interference have been identified. To pick up the real active compounds among the primary hits from the fluorescence assay, we developed a RapidFire mass spectrometry assay and a conventional radioisotope assay. These assays have the advantage of detecting the main products directly without using fluorescent-labeled substrates. As a result, 276 compounds (30%) of the primary hits (921 compounds) in a fluorescence ultra-high-throughput screening method were identified as common active compounds in these two assays. It is concluded that both methods are very effective to eliminate false positives. Compared with the radioisotope method using an expensive {sup 14}C-labeled substrate, the RapidFire mass spectrometry method using unlabeled substrates is a high-accuracy, high-throughput method. In addition, some of the hit compounds selected from the screening inhibited cellular fatty acid elongation in HEK293 cells expressing Elovl6 transiently. This result suggests that these compounds may be promising lead candidates for therapeutic drugs. Ultra-high-throughput fluorescence screening followed by a RapidFire mass spectrometry assay was a suitable strategy for lead discovery against Elovl6. - Highlights: • A novel assay for elongation of very-long-chain fatty acids 6 (Elovl6) is proposed. • RapidFire mass spectrometry (RF-MS) assay is useful to select real screening hits. • RF-MS assay is proved to be beneficial because of its high-throughput and accuracy. • A combination of fluorescent and RF-MS assays is effective for Elovl6 inhibitors.

60 APPLIED LIFE SCIENCES↗

Predicting protein functions from redundancies in large-scale protein interaction networks

Interpreting data from large-scale protein interaction experiments has been a challenging task because of the widespread presence of random false positives. Here, we present a network-based statistical algorithm that overcomes this difficulty and allows us to derive functions of unannotated proteins from large-scale interaction data. Our algorithm uses the insight that if two proteins share significantly larger number of common interaction partners than random, they have close functional associations. Analysis of publicly available data from Saccharomyces cerevisiae reveals >2,800 reliable functional associations, 29% of which involve at least one unannotated protein. By further analyzing these associations, we derive tentative functions for 81 unannotated proteins with high certainty. Our method is not overly sensitive to the false positives present in the data. Even after adding 50% randomly generated interactions to the measured data set, we are able to recover almost all (approximately 89%) of the original associations.

Proteins/chemistry/metabolism↗

Discovering Mercury Protein Modifications in Whole Proteomes Using Natural Isotope Distributions Observed in Liquid Chromatography-Tandem Mass Spectrometry

The identification of peptides that result from post-translational modifications is critical for understanding normal pathways of cellular regulation as well as identifying damage from, or exposures to xenobiotics, i.e. the exposome. However, because of their low abundance in proteomes, effective detection of modified peptides by mass spectrometry (MS) typically requires enrichment to eliminate false identifications. We present a new method for confidently identifying peptides with mercury (Hg)-containing adducts that is based on the influence of mercury's seven stable isotopes on peptide isotope distributions detected by high-resolution MS. Using a pure protein and E. coli cultures exposed to phenyl mercuric acetate, we show the pattern of peak heights in isotope distributions from primary MS single scans efficiently identified Hg adducts in data from chromatographic separation coupled with tandem mass spectrometry with sensitivity and specificity greater than 90%. Isotope distributions are independent of peptide identifications based on peptide fragmentation (e.g. by SEQUEST), so both methods can be combined to eliminate false positives. Summing peptide isotope distributions across multiple scans improved specificity to 99.4% and sensitivity above 95%, affording identification of an unexpected Hg modification. We also illustrate the theoretical applicability of the method for detection of several less common elements including the essential element, selenium, as selenocysteine in peptides.

59 BASIC BIOLOGICAL SCIENCES↗