Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing NDE Reliability for Grade 91 Steel Welds: Ultrasonic Imaging and Microstructural Correlations

Ensuring the integrity of Grade 91 (9Cr-1Mo-V) steel welds is vital for the safe and reliable operation of fossil fuel–fired and nuclear power plants. Here, this study applies an imaging technique for the ultrasonic characterization of two Grade 91 steel welds created with cold metal transfer and flux-cored arc welding processes. Ultrasonic immersion testing in the through-transmission configuration was employed to generate shear waves, which helped identify the weld metal, heat-affected zone, and base metal regions. These weld microstructures were also correlated to their ultrasonic images using metallography, ultrasonic amplitude, hardness measurements, and grain size. The findings from this study can assist practitioners in developing new nondestructive evaluation technologies, improving the inspection reliability of creep strength–enhanced ferritic steel welds by potentially identifying weld microstructure regions susceptible to creep-type failures.

Grade 91 steel↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Dark matter clusters and time correlations in direct detection experiments

Assuming that dark matter (DM) efficiently clusters on various scales we analyse the possible impact on direct DM searches. For certain sizes and densities of DM clusters, mutual detector-cluster encounters may occur only once a year or every several years leading to the apparent failure of individual experiments searching for DM to discover it. If, however, encounters with Earth size and up to 10 4 times bigger clusters occur about once a year, then finding time correlations between events in different underground detectors can lead to DM discovery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid data-driven and model-informed online tool wear detection in milling machines

Precision machining tool wear is responsible for low product throughput and quality. Monitoring the tool wear online is vital to prevent degradation in machining quality. However, direct real-time tool wear measurement is not practical. This paper presents residual-based anomaly detection models, combining a hybrid model comprised of a physics-based model and a data-driven model (a decision tree or a neural network) to predict signals of interest (e.g., power or forces) under nominal conditions, followed by Page’s cumulative sum test for detecting tool wear on-line using the computer numerical control machine measurements. The most informative features are ranked using dynamic programming and its approximation variants from real-time measurements and machine settings, such as the width of cut, depth of cut, feed rate and spindle speed, that serve as inputs to the predictive models. The baseline nominal model is incrementally updated with experimental data via a gradient boosted adaptation model to generate the residuals that account for discrepancies between the actual machine data under normal conditions and the baseline nominal model predictions. The hybrid model is validated against 20 Mazak milling machine experimental tests and one Haas run-to-failure experiment. The proposed anomaly detector is applied to synthetic data from simulations of the physics-based model at different operating conditions, measurement noise levels, and tool wear levels, and the methods were able to achieve an overall 92% accuracy in data with 1% noise. The anomaly detection methods based on hybrid model reduced the false alarms of either the data-driven or physical-based models alone, and are found to be capable of good online detection of tool wear.

42 ENGINEERING↗

Underwater unexploded ordnance discrimination based on intrinsic target polarizabilities – A case study

Seabed unexploded ordnance that resulted partly from the high failure rate among munitions from more than 80 years ago and from decades of military training and testing of weapons systems poses an increasing concern all around the world. Although existing magnetic systems can detect clusters of debris, they are not able to tell whether a munition is still intact requiring special removal (e.g. in situ detonation) or is harmless scrap metal. The marine environment poses unique challenges, and transferring knowledge and approaches from land to a marine environment has not been easy and straightforward. On land, the background soil conductivity is much lower than the conductivity of the unexploded ordnance and the electromagnetic response of a target is essentially the same as that in free space. For those frequencies required for target characterization in the marine environment, the seawater response must be accounted for and removed from the measurements. The system developed for this study uses fields from three orthogonal transmitters to illuminate the target and four three-component receivers to measure the signal arranged in a configuration that inherently cancels the system's response due to the enclosing seawater, the sea–bottom interface and the air–sea interface for shallow deployments. The system was tested as a cued system on land and underwater in San Francisco Bay – it was mounted on a simple platform on top of a support structure that extended 1 m below and allowed the diver to place metal objects to a specific location even in low-visibility conditions. The measurements were stable and repeatable. Furthermore, target responses estimated from marine measurements matched those from land acquisition, confirming that the seawater and air–sea interface responses were removed successfully. Thirty-six channels of normalized induction responses were used for the classification, which was done by estimating the target principal dipole polarizabilities. Our results demonstrated that the system can resolve the intrinsic polarizabilities of the target, with clear distinctions between those of symmetric intact unexploded ordnance and irregular scrap metal. The prototype system was able to classify an object based on its size, shape and metal content and correctly estimate its location and orientation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Integration of Condition-Based, Diagnostic, Prognostic, And Anomaly Detection Data into Reliability Models to Support a Predictive Maintenance Context

Reliability data employed in plant reliability models are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating actual health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). This paper proposes a reliability modeling approach that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. We show how state-of-the art condition-based, diagnostic, prognostic, and anomaly detection models can be linked to system reliability models not in probability terms, but in terms of margin where margin is defined as the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Then, we show how the propagation of margin data from the asset to the system level is performed through classical reliability models such as fault trees or reliability block diagrams. The described method is in fact able to propagate heterogenous health data from the asset to the system level in order to analytically assess system health.

97 MATHEMATICS AND COMPUTING↗

Assessing the Expansion of Ground-Motion Sensing Capability in Smart Cities via Internet Fiber-Optic Infrastructure

Monitoring ground motion in smart cities can improve the public safety by providing critical insights on natural and anthropogenic hazards, for example, earthquakes, landslides, explosions, infrastructure failures, and so forth. Although seismic activity is typically measured using dedicated point sensors (e.g., geophones and accelerometers), techniques such as distributed acoustic sensing have demonstrated the utility of using fiber-optic cable to detect seismic activity over comparable distances. In this article, we present the results of a study that quantifies the expansion in an area monitored for low-amplitude ground-motion events by augmenting existing point sensors with the internet fiber-optic cable infrastructure. Here we begin by describing our methodology, which utilizes geospatial data on point sensors and internet optical fiber deployed in metropolitan statistical areas (MSAs) in the United States. We extend these data to identify the area that can be monitored by (1) considering the observed seismic noise data in target locations, (2) applying the model from Wilson et al. (2021) to understand the potential coverage area gains using optical fiber sensing, and (3) optimizing the selection of fiber segments to maximize coverage and minimize deployment costs. We implement our methodology in ArcGIS to assess the additional area that can be monitored for low-amplitude ground-motion events (i.e., magnitude >0.5) by utilizing internet fiber-optic cables in the 100 most populous MSAs in the United States. We find that the addition of internet fiber-based sensors in MSAs would increase the area monitored on average by over an order of magnitude from 1% to 12%, if the subset of fiber cable segments that maximize coverage and minimize deployment costs is chosen even if only 20% of all fibers are used.

58 GEOSCIENCES↗

Combined ambient vibration and surface displacement measurements for improved progressive failure monitoring at a toppling rock slab in Utah, USA

Seismic resonance and surface displacement measurements can be implemented in tandem to improve landslide characterization and progressive failure monitoring. Crack aperture data are frequently used in rock slope stability monitoring and often exhibit recognizable trends prior to failure, such as accelerated crack opening. Alternatively, ambient resonance data offer multiple parameters including modal frequencies, damping, and polarization that can be monitored alongside crack aperture and may respond differently to environmental forcings and complex failure evolution. We analyzed data from continuous ambient vibration monitoring and concomitant crack aperture measurements at the Courthouse Mesa instability, a large toppling sandstone slab in Utah, USA. Three years of data revealed crack aperture increases of 2–4 mm/year with no clearly detectable irreversible changes in modal parameters, including frequency. Annually, frequency and displacement varied by 29% and 19% of the mean, respectively, with average and maximum daily frequency fluctuations of 6.5% and 16%, respectively. These reversible cyclic changes were primarily temperature-driven, but annually, frequency was in-phase with temperature whereas crack aperture lagged temperature changes by ~37 days. Polarization and damping also varied seasonally but were less strongly correlated with temperature. Conceptual 3D finite element modeling demonstrated consistent frequency decreases associated with crack propagation but variable changes in crack aperture measured at a single point; i.e., crack propagation did not always result in increased crack opening but always generated a resonance frequency decrease. Taken together, our data suggest a possible thermal wedging-ratcheting mechanism at the Courthouse Mesa instability, where annual thermoelastic crack closure is impeded by debris infill but the absence of downward crack propagation during the monitoring period is evidenced by no permanent resonance frequency changes. Our study demonstrates that combined seismic resonance and crack aperture data provide an improved description of rock slope instability behavior, supporting refined characterization and monitoring of changes accompanying progressive failure.

58 GEOSCIENCES↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-temperature Rutherford Backscattering Spectrometry apparatus for in situ material characterization

A new methodology for high-temperature Rutherford Backscattering Spectrometry (HT-RBS) has been developed to enable in situ material characterization at elevated temperatures. A 3.5 MeV proton beam penetrates a 10-µm-thick 316L stainless steel foil mounted on a graphite substrate, with backscattered signals detected using an HT-RBS system. Conventional semiconductor detectors, primarily based on silicon, suffer significant performance degradation at temperatures higher than ~ 60 °C due to increased leakage current and noise, leading to signal distortion and failure. Here, to preserve spectral quality, a 5 µm aluminum foil shields the detector from thermal radiation, allowing reliable operation up to 900 °C at the target. A rotatable shutter provides additional thermal isolation during data collection pauses. In situ measurements of areal density changes of 316L stainless steel were conducted to validate the technique, revealing consistency with the known thermal expansion coefficient. The method facilitates seamless switching between irradiation and analysis, enabling continuous studies. This approach supports in situ investigations of diffusion, void swelling, creep, and corrosion, offering a versatile tool for advanced materials research.

36 MATERIALS SCIENCE↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗