Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

An auroral breakup mechanism

A purely growing electrostatic drift instability driven by the electron temperature gradient at the inner edge of the plasma sheet can grow for large enough values of the temperature gradient. The parallel electric field associated with the instability is localized near the magnetic equator. The growth of the drift instability leads to enhanced whistler noise and increased electron pitch angle diffusion. If the current limit is exceeded in the ionosphere while the parallel electric field of the drift instability exists along the field line, rapid electron precipitation (the auroral breakup) can result.

Maggs, J. E.↗

Electron concentrations calculated from the lower hybrid resonance noise band observed by Ogo 3.

A noise band at the lower hybrid resonance (LHR) is often detected by the VLF and ELF receivers on Ogo 3, using the electric antenna. In some cases the noise band is at the geometric mean gyrofrequency as measured by the Goddard Space Flight Center (GSFC) magnetometer, and local LHR in a dense H(+) plasma is indicated; in such cases, electron concentration can be calculated, if it is assumed that heavy ions are negligible. Observations at midlatitudes and altitudes of a few earth radii show local concentrations as low as 1.4 electrons/cu cm. In one case the concentrations obtained from the LHR noise band agree with those measured simultaneously by the GSFC ion mass spectrometer within a factor of 2. In another case the concentration is observed to fall by a factor of 2 in 150 km and then to decrease roughly as R to the minus fourth power, in agreement with whistler measurements outside the plasmapause.

Burtis, W. J.↗

Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation

HEMT-based receiver arrays with excellent noise and scalability are already starting to be manufactured at 100 GHz, but the advances in technology should make it possible to develop receiver modules with even greater operation frequency up to 200 GHz. A prototype heterodyne amplifier module has been developed for operation from 140 to 170 GHz using monolithic millimeter-wave integrated circuit (MMIC) low-noise InP high electron mobility transistor (HEMT) amplifiers. The compact, scalable module is centered on the 150-GHz atmospheric window using components known to operate well at these frequencies. Arrays equipped with hundreds of these modules can be optimized for many different astrophysical measurement techniques, including spectroscopy and interferometry. This module is a heterodyne receiver module that is extremely compact, and makes use of 35-nm InP HEMT technology, and which has been shown to have excellent noise temperatures when cooled cryogenically to 30 K. This reduction in system noise over prior art has been demonstrated in commercial mixers (uncooled) at frequencies of 160-180 GHz. The module is expected to achieve a system noise temperature of 60 K when cooled. An MMIC amplifier module has been designed to demonstrate the feasibility of expanding heterodyne amplifier technology to the 140 to 170-GHz frequency range for astronomical observations. The miniaturization of many standard components and the refinement of RF interconnect technology have cleared the way to mass-production of heterodyne amplifier receivers, making it a feasible technology for many large-population arrays. This work furthers the recent research efforts in compact coherent receiver modules, including the development of the Q/U Imaging ExperimenT (QUIET) modules centered at 40 and 90 GHz, and the production of heterodyne module prototypes at 90 GHz.

Kangaslahti, Pekka P.↗

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Advanced Components for Spaceborne Infrared Astronomy

Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.

Davidson, Arnold W.↗

Intensity noise in diode-pumped single-frequency Nd:YAG lasers and its control by electronic feedback

The power spectrum of the relative intensity noise (RIN) of single-frequency diode-pumped Nd:YAG lasers is observed to be shot-noise limited at frequencies above 20 MHz for a photocurrent of up to 4.4 mA. Relaxation oscillations result in noise 60-70 dB above shot noise at a few hundred kHz. These relaxation oscillations have been suppressed using electronic feedback.

Kane, Thomas J.↗

Electron velocity space hole modes and narrowband electrostatic noise in the distant tail

Narrowband electrostatic noise (NEN) is frequently observed upstream of the slow shocks in the distant tail. It is suggested that NEN represents a nonstandard plasma wave mode which results from a hole in the low energy electron velocity distribution. A very simple model which plausibly indicates how a hole might be formed by the interaction of the electrons with the slow shock is presented. The hole mode is destabilized by a positive slope in the parallel electron distribution and/or by a weak beam of energetic ions which escape upstream from the slow shock.

Coroniti, Ferdinand V.↗

Scaling and merging time-resolved pink-beam diffraction with variational inference

Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.

47 OTHER INSTRUMENTATION↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

X Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 ??ong niobium microbridge with T c =(approx. equal to)5K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if{italics})) of several GHz. A Y-factor response of 1.15dB has been obtained at an if(italics) of 1.4 GHz with 77k and 295k loads, indicating a receiver noise temperature of 650 k DSB. The -3 dB rolloff in the if(italics) response occurs at 1.7 GHz.

Heterodyne↗

A 90 GHz Amplifier Assembled Using a Bump-Bonded InP-Based HEMT

We report on the performance of a novel W-band amplifier fabricated utilizing very compact bump bonds. We bump-bonded a high-speed, low-noise InP high electron mobility transistor (HEMT) onto a separately fabricated passive circuit having a GaAs substrate. The compact bumps and small chip size were used for efficient coupling and maximum circuit design flexibility. This new quasi-monolithic millimeter-wave integrated circuit (Q-MMIC) amplifier exhibits a peak gain of 5.8 dB at approx. 90 GHz and a 3 dB bandwidth of greater than 25%. To our knowledge, this is the highest frequency amplifier assembled using bump-bonded technology. Our bump-bonding technique is a useful alternative to the high cost of monolithic millimeter-wave integrated circuits (MMIC's). Effects of the bumps on the circuit appear to be minimal. We used the simple matching circuit for demonstrating the technology - future circuits would have all of the elements (resistors, via holes, bias lines, etc.) included 'in conventional MMIC's. Our design in different from other investigators' efforts in that the bumps are only 8 microns thick by 15 microns wide. The bump sizes were sufficiently small that the devices, originally designed for W-band hybrid circuits, could be bonded without alteration. Figure 3 shows the measured and simulated magnitude of S-parameters from 85-120 GHz, of the InP HEMT bump-bonded to the low noise amplifier (LNA) passive. The maximum gain is 5.8 dB at approx. 90 GHz, and gain extends to 117 GHz. Measurement of a single device (without matching networks) shows approx. 1 dB of gain at 90 GHz. The measured gain of the amplifier agrees well with the design in the center of the measurement band, and the agreement falls off at the band edges. Since no accommodation for the bump-bonding parasitics was made in the design, the result implies that the parasitic elements associated with the bonding itself do not dominate the performance of the LNA circuit. It should be noted that this amplifier was designed for good noise performance, which is why the input and output return losses are poorer than one would expect for an amplifier simply matched for gain. However, noise performance has not been measured at this time. While the agreement between modeled vs. experimental data is not exact, the data prove that bump-bonded technology can be used for amplifiers at frequencies at least as high as 100 GHz. JPL is pursuing this technology as a way to economically and quickly incorporate the best available HEMTs into a circuit with all of the reliability and circuit design flexibility offered by MMIC technology. We are currently using the technology to fabricate 4-stage, wide-band, W-band LNA's. We have also performed pull and shear tests which show that the bump bonds are sufficiently robust for any anticipated application.

Pinsukanjana, Paul R.↗

Large Bandwidth and Low Noise in a Diffusion-Cooled Hot-Electron Bolometer Mixer

Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 micrometer long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection with intermediate frequencies (if) of several GHz. A Y-factor response of 1.15 dB has been obtained at an if of 1.4 GHz with 77 and 295 K loads, indicating a receiver noise temperature of 650 K DSB. The -3 dB rolloff in the if response occurs at 1.7 GHz.

Skalare, A.↗

(abstract) A Miniature, High-Sensitivity, Electron-Tunneling Accelerometer

A prototype low-noise accelerometer has been fabricated with an electron-tunneling transducer. By measuring the tunneling current between an electrode on the proof mass and a feedback-controlled monitor electrode, very small accelerations can be detected with high responsivity. This particular prototype (10x10x1.5 mm) was designed for underwater acoustic measurement from a few hertz to 1 kHz. The measured responsivity below the fundamental device resonance at 100 Hz is roughly 1500 volts per m/s(sup 2) with a measured noise spectral density of 10(sup -6) m/s(sup 2) per root hertz or less between 30 and 300 Hz. The noise floor is controlled primarily by 1/f noise in the tunneling current although the noise floor reaches the theoretical molecular-agitation limit at 100 hertz. The responsivity and directivity of the device were measured in a standard gradient-hydrophone calibrator; the noise floor was determined in a vacuum-ionization chamber assembled from commercial off-the-shelf components; and the detailed dynamics of the proof-mass motion were examined using a heterodyne laser interferometer that was scanned across the surface and synchronously detected with respect to the excitation.

accelerometer electron tunneling acoustic measurem↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗