Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron streaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Genesis failure investigation report : JPL Failure Review Board, Avionics Sub-Team

On January 7, 2001, the Genesis spacecraft lifted off from Cape Canaveral. Its mission was to collect solar wind samples and return those samples to Earth for detailed analysis by scientists. The mission proceeded successfully for three-and-a-half years. On September 8, 2004, the spacecraft approached Earth, pointed the Sample Return Capsule (SRC) at its entry target, and then fired pyros that jettisoned the SRC. The SRC carried the valuable samples collected over the prior 29 months. The SRC also contained the requisite hardware (mechanisms, parachutes, and electronics) to manage the process of entry, descent, and landing (EDL). After entering Earthas atmosphere, the SRC was expected to open a drogue parachute. This should have been followed by a pyro event to release the drogue chute, and then by a pyro event to deploy the main parachute at an approximate elevation of 6.7 kilometers. As the SRC descended to the Utah landing site, helicopters were in position to capture the SRC before the capsule touched down. On September 8, 2004, observers of the SRCas triumphant return became concerned as the NASA announcer fell silent, and then became even more alarmed as they watched the spacecraft tumble as it streaked across the sky. Long-distance cameras clearly showed that the drogue parachute had not deployed properly. On September 9, 2004, General Eugene Tattini, Deputy Director of the Jet Propulsion Laboratory formed a Failure Review Board (FRB). This board was charged with investigating the cause of the Genesis mishap in close concert with the NASA Mishap Investigation Board (MIB). The JPL-FRB was populated with experts from within and external to the Jet Propulsion Laboratory. The JPL-FRB participated with the NASA-MIB through all phases of the investigation, working jointly and concurrently as one team to discover the facts of the mishap.

solar wind↗

Thermodynamics of the Solar Corona and Evolution of the Solar Magnetic Field as Inferred from the Total Solar Eclipse Observations of 11 July 2010

We report on multi-wavelength observations of the corona taken simultaneously in broadband white light, and in seven spectral lines, H-alpha 656.3 nm, Fe IX 435.9 nm, Fe X 637.4 nm, Fe XI 789.2 nm, Fe XIII 1074.7 nm, Fe XIV 530.3 nm and Ni XV 670.2 nm. The observations were made during the total solar eclipse of 11 July 2010 from the atoll of Tatakoto in French Polynesia. Simultaneous imaging with narrow bandpass filters in each of these spectral lines and in their corresponding underlying continua maximized the observing time during less than ideal observing conditions and yielded outstanding quality data. The application of two complementary image processing techniques revealed the finest details of coronal structures at 1" resolution in white light, and 6.5" in each of the spectral lines. This comprehensive wavelength coverage confirmed earlier eclipse findings that the solar corona has a clear two-temperature structure: The open field lines, expanding outwards from the solar surface, are characterized by electron temperatures near 1 X 10(exp 6) K, while the hottest plasma around 2X 10(exp 6) K resides in loop-like structures forming the bulges of streamers. The first images of the corona in the forbidden lines of Fe IX and Ni XV, showed that there was very little coronal plasma at temperatures below 5 X 10(exp 5) K and above 2.5X 10(exp 6) K. The data also enabled temperature differentiations as low as 0:2 X 10(exp 6) K in different density structures. These observations showed how the passage of CMEs through the corona, prior to totality, produced large scale ripples and very sharp streaks, which could be identified with distinct temperatures for the first time. The ripples were most prominent in emission from spectral lines associated with temperatures around 10(exp 6) K. The most prominent streak was associated with a conical-shaped void in the emission from the coolest line of Fe IX and from the hottest line of Ni XV. A prominence, which erupted prior to totality, appeared in the shape of a hook in the cooler lines of Fe X and Fe XI, spanning 0.5 R(solar) in extent starting at a heliocentric distance of 1.3 R(solar), with a complex trail of hot and cool twisted structures connecting it to the solar surface. Simultaneous Fe X 17.4 nm observations from space by Proba2/SWAP provided an ideal opportunity for comparing emission from a coronal forbidden line, namely Fe X 637.4 nm, with a space-based EUV allowed line. Comparison of the Fe X 17.4 nm and 637.4 nm emission provided the first textbook example of the role of radiative excitation in extending the detectability of coronal emission to much larger heliocentric distances than its collisionally excited component. These eclipse observations demonstrate the unique capabilities of coronal forbidden lines for exploring the evolution of the coronal magnetic field in the heliocentric distance range of 1 - 3 R(solar), which is currently inaccessible to any space-borne or ground-based observatory.

Habbal, Shadia Rifai↗

Genesis failure investigation report

On January 7, 2001, the Genesis spacecraft lifted off from Cape Canaveral. Its mission was to collect solar wind samples and return those samples to Earth for detailed analysis by scientists. The mission proceeded successfully for three-and-a-half years. On September 8, 2004, the spacecraft approached Earth, pointed the Sample Return Capsule (SRC) at its entry target, and then fired pyros that jettisoned the SRC. The SRC carried the valuable samples collected over the prior 29 months. The SRC also contained the requisite hardware (mechanisms, parachutes, and electronics) to manage the process of entry, descent, and landing (EDL). After entering Earth’s atmosphere, the SRC was expected to open a drogue parachute. This should have been followed by a pyro event to release the drogue chute, and then by a pyro event to deploy the main parachute at an approximate elevation of 6.7 kilometers. As the SRC descended to the Utah landing site, helicopters were in position to capture the SRC before the capsule touched down. On September 8, 2004, observers of the SRC’s triumphant return became concerned as the NASA announcer fell silent, and then became even more alarmed as they watched the spacecraft tumble as it streaked across the sky. Long-distance cameras clearly showed that the drogue parachute had not deployed properly.

UNKNOWN↗

Implosion dynamics and radiation characteristics of wire-array Z pinches on the Cornell Beam Research Accelerator

Experimental results are presented that characterize the implosion dynamics and radiation output of wire-array Z pinches on the 1-MA, 100-ns rise-time Cornell Beam Research Accelerator (COBRA) [J. B. Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]. The load geometries investigated include 20-mm-tall cylindrical arrays ranging from 4 to 16 mm in diameter, and consisting of 8, 16, or 32 wires of either tungsten, aluminum, or Invar (64% iron, 36% nickel). Diagnostics fielded include an optical streak camera, a time-gated extreme-ultraviolet framing camera, a laser shadowgraph system, time-integrated pinhole cameras, an x-ray wide-band focusing spectrograph with spatial resolution, an x-ray streak camera, a load voltage monitor, a Faraday cup, a bolometer, silicon diodes, and diamond photoconducting detectors. The data produced by the entire suite of diagnostics are analyzed and presented to provide a detailed picture of the overall implosion process and resulting radiation output on COBRA. The highest x-ray peak powers (300-500 GW) and total energy yields (6-10 kJ) were obtained using 4-mm-diameter arrays that stagnated before peak current. Additional findings include a decrease in soft x-ray radiation prior to stagnation as the initial wire spacing was changed from 1.6 mm to 785 {mu}m, and a timing correlation between the onset of energetic electrons, hard x-ray generation, and the arrival of trailing current on axis - a correlation that is likely due to the formation of micropinches. The details of these and other findings are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Target Diagnostics Supports NIF's Path to Ignition

The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

42 ENGINEERING↗

Space and Time Resolved Measurements of the Heating of Solids to Ten Million Kelvin by a Petawatt Laser

The heating of plane solid targets by the Vulcan petawatt laser at powers of 0.32-0.73 PW and intensities of up to 4 x 10^20 W cm^-2 has been diagnosed with a temporal resolution of 17 ps and a spatial resolution of 30 um, by measuring optical emission from the opposite side of the target to the laser with a streak camera. Second harmonic emission was filtered out and the target viewed at an angle to eliminate optical transition radiation. Spatial resolution was obtained by imaging the emission onto a bundle of fibre optics, arranged into a one-dimensional array at the camera entrance. The results show that a region 160 um in diameter can be heated to a temperature of ~10^7 K (kT/e ~ keV) in solid targets from 10 to 20 um thick and that this temperature is maintained for at least 20 ps, confirming the utility of PW lasers in the study of high energy density physics. Hybrid code modelling shows that magnetic field generation prevents increased target heating by electron refluxing above a certain target thickness and that the absorption of laser energy into electrons entering the solid target was between 15-30%, and tends to increase with laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Redgillite, Cu[subscript 6](OH)1 0(SO[subscript 4]).2H[subscript 2]O, a new mineral from Caldbeck Fells, Cumbria, England, UK: Description and crystal structure

Redgillite, Cu{sub 6}(OH){sub 10}(SO{sub 4}) {center_dot} H{sub 2}O, space group P2{sub 1}/c, a 3.155(3) {angstrom}, b 10.441(8) {angstrom}, c 19.436(16) {angstrom}, {beta} 90.089(13){sup o}, V = 640.2(9) {angstrom}{sup 3}, Z = 2, is a new mineral from Silver Gill, Caldbeck Fells, Cumbria, England. The strongest six lines of the X-ray powder-diffraction pattern [d in {angstrom}, (I) (hkl)] are: 9.72 (90) (002), 7.11 (100) (012), 4.60 (30) (022), 4.068 (20) (023), 2.880 (30) (112,11{bar 2}), 2.318 (50) (131,13{bar 1}). It occurs as translucent to transparent grass-green bladed crystals up to 0.15 mm long with squared-off or tapering terminations; usually in radiating groups. Forms observed are {l_brace}001{r_brace} prominent, {l_brace}010{r_brace} as composite stepped faces, and {l_brace}100{r_brace} irregular. Redgillite has white streak, vitreous lustre and Mohs hardness of {approx}2. Blades are slightly flexible with irregular fracture and exhibit a perfect {l_brace}001{r_brace} cleavage and good {l_brace}100{r_brace} and {l_brace}010{r_brace} cleavages. The measured density (by sink-float) is 3.45(5) g/cm{sup 3}; the calculated density is 3.450 g/cm{sup 3}. The mineral dissolves slowly in dilute HCl. Redgillite is biaxial-negative with {alpha} = 1.693(2), {beta} = 1.721(2), {gamma} = 1.723(2), 2V = 30(2){sup o} (meas.) and 30{sup o} (calc.); dispersion is r > v, medium; pleochroism: Y blue-green > X blue-green > Z yellow-green; orientation: X c, Y = b, Z a. Electron microprobe analyses yielded CuO 68.9, SO{sub 3} 11.6, total 80.5. With water inferred from the structure analysis, the empirical formula is: Cu{sub 5.995}(OH){sub 9.991}(SO{sub 4}){sub 1.003} {center_dot} H{sub 2}O. Redgillite is typically found in thin fractures in partly oxidized sulphides where it is commonly associated with langite and more rarely with malachite, cuprite, connellite and brochantite. The name is for the Red Gill mine, from which the mineral is best known. The crystal structure of redgillite was determined and refined to R = 0.090 for 1529 observed reflections [I > 2{sub {sigma}}(I)]. The redgillite structure consists of Jahn-Teller distorted CuO{sub 6} octahedra and SO{sub 4} tetrahedra. The octahedra share edges to form sheets that are zig-zag in cross section. The SO{sub 4} tetrahedra share an oxygen with the Cu layer and link the layers by hydrogen bonds to OH groups. The crystal structures of wroewolfeite, langite, posnjakite, spangolite and schulenbergite are similar to redgillite. They all contain edge sharing CuO{sub 6} layers connected to SO{sub 4} groups with the layers bridged via hydrogen bonds.

08 HYDROGEN↗

Possible Microfossils (Warrawoona Group, Towers Formation, Australia, approximately 3.3 - 3.5 Ga)

Early in the twentieth century there were reports of Archean stromatolite-like structures that were similar to organic rich stromatolites from the base of the Cambrian (600 m.y.). It was not until the latter half of this century that fossilized Archean-age (3.9-2.5 Ga) life forms were found in the Fig Tree Formation of South Africa and the Towers Formation of Australia. Some of the ancient stromatolites contained streaks and clots of kerogen, pyrite grains, remnants of microbial cells, and filaments that represented various stages of preservation, while others appeared to lack fossils. A set of physical criteria was established for evaluating the biogenicity of these Archean discoveries: (1) rocks of unquestionable Archean age; (2) microfossils indigenous to Archean sediments; and (3) microfossils occurring in clasts that are syngenetic with deposition of the sedimentary unit. In the case of bedded cherts, the fossils should predate the cherts; (4) the microfossils are biogenic; and (5) replicate sampling of the fossil-iferous outcrop firmly demonstrates the provenance of these microfossils. Sample 002 from the Precambrian Paleobiology Research Group (PPRG) was examined. This stromatolitic carbonaceous chert contains microbial remains that meet the established criteria [10]. Using a scanning electron microscope (SEM), we have analyzed the morphologies and chemistry of these possible microbial remains.

Morris, P. A.↗

Surface interactions involved in flashover with high density electronegative gases.

This report examines the interactions involved with flashover along a surface in high density electronegative gases. The focus is on fast ionization processes rather than the later time ionic drift or thermalization of the discharge. A kinetic simulation of the gas and surface is used to examine electron multiplication and includes gas collision, excitation and ionization, and attachment processes, gas photoionization and surface photoemission processes, as well as surface attachment. These rates are then used in a 1.5D fluid ionization wave (streamer) model to study streamer propagation with and without the surface in air and in SF6. The 1.5D model therefore includes rates for all these processes. To get a better estimate for the behavior of the radius we have studied radial expansion of the streamer in air and in SF6. The focus of the modeling is on voltage and field level changes (with and without a surface) rather than secondary effects, such as, velocities or changes in discharge path. An experiment has been set up to carry out measurements of threshold voltages, streamer velocities, and other discharge characteristics. This setup includes both electrical and photographic diagnostics (streak and framing cameras). We have observed little change in critical field levels (where avalanche multiplication sets in) in the gas alone versus with the surface. Comparisons between model calculations and experimental measurements are in agreement with this. We have examined streamer sustaining fields (field which maintains ionization wave propagation) in the gas and on the surface. Agreement of the gas levels with available literature is good and agreement between experiment and calculation is good also. Model calculations do not indicate much difference between the gas alone versus the surface levels. Experiments have identified differences in velocity between streamers on the surface and in the gas alone (the surface values being larger).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Internal Heterogeneous Processes in Aluminum Combustion

This paper discusses the aluminum particle combustion mechanism which has been expanded by inclusion of gas dissolution processes and ensuing internal phase transformations. This mechanism is proposed based on recent normal and microgravity experiments with particles formed and ignited in a pulsed micro-arc. Recent experimental findings on the three stages observed in Al particle combustion in air and shows the burning particle radiation, trajectory (streak), smoke cloud shapes, and quenched particle interiors are summarized. During stage I, the radiation trace is smooth and the particle flame is spherically symmetric. The temperature measured using a three-color pyrometer is close to 3000 K. Because it exceeds the aluminum boiling point (2730 K), this temperature most likely characterizes the vapor phase flame zone rather than the aluminum surface. The dissolved oxygen content within particles quenched during stage I was below the detection sensitivity (about 1 atomic %) for Wavelength Dispersive Spectroscopy (WDS). After an increase in the radiation intensity (and simultaneous decrease in the measured color temperature from about 3000 to 2800 K) indicative of the transition to stage II combustion, the internal compositions of the quenched particles change. Both oxygen-rich (approx. 10 atomic %) and oxygen-lean (< 1 %) regions are identified within the particles using back-scattered electron imaging and WDS. During stage II, oscillations are observed in particle radiation and the flame and smoke cloud are distorted from their original spherically-symmetric shape. In stage III, particle radiation continues to exhibit oscillations, but its radiation intensity drops and remains at a nearly constant level. The measured temperature decreases to about 2300 K. Also, larger changes in particle velocities are observed, and oxide caps are found on quenched particle surfaces. While these results showed the correlation between the aluminum particle combustion behavior and the evolution of its internal composition, the change from the spherically symmetric to asymmetric flame shape occurring upon the transition from stage I to stage II combustion could not be understood based only on the fact that dissolved oxygen is detected in the particles. The connection between the two phenomena appeared even less significant because in earlier aluminum combustion studies carried in O2/Ar mixtures, flame asymmetry was not observed as opposed to experiments in air or O2/CO mixtures. It has been proposed that the presence of other gases, i.e., hydrogen, or nitrogen causes the change in the combustion regime.

Dreizin, E. L.↗

Optical Spectroscopy Results for the Self-Magnetic Pinch Electron Beam Diode on the RITS-6 Accelerator

Experiments have been conducted at Sandia National Laboratories' RITS-6 accelerator facility [1] (operating at 7.5 MV and 180 kA) investigating plasma formation and propagation in relativistic electron beam diodes used for flash x-ray radiography. High resolution, visible and ultraviolet spectra were collected in the anode-cathode (A-K) vacuum gap of the Self-Magnetic Pinch (SMP) diode [2-4]. Time and space resolved spectra are compared with time-dependent, collisional-radiative (CR) calculations [5-7] and Lsp, hybrid particle-in-cell code simulations [8,9]. Results indicate the presence of a dense (>1x10 17 cm -3 ), low temperature (few eV), on-axis plasma, composed of hydrocarbon and metal ion species, which expands at a rate of several cm/s from the anode to the cathode. In addition, cathode plasmas are observed which extend several millimeters into the A-K gap [10]. It is believed that the interaction of these electrode plasmas cause premature impedance collapse of the diode and subsequent reduction in the total radiation output. Diagnostics include high speed imaging and spectroscopy using nanosecond gated ICCD cameras, streak cameras, and photodiode arrays.

Johnston, Mark D.↗

Metrology of Time-Domain Soft X-Ray Attosecond Pulses and Reevaluation of Pulse Durations of Three Recent Experiments

Attosecond pulses in the soft x-ray (SXR) to water-window energy region offer the tools for creating and studying target-specific localized inner-shell electrons or holes in materials, enabling monitoring or controlling charge and energy flows in a dynamic system on attosecond timescales. Recently, a number of laboratories have reported generation of continuum harmonics in the hundred-electron-volt to kilovolt region with few-cycle long-wavelength mid-infrared lasers. These harmonics have the bandwidth to support pulses with durations of a few to a few-ten attoseconds. But harmonics generated in a gas medium have attochirps that cannot be fully compensated by materials over a broad spectral range; thus, realistically what are the typical shortest attosecond pulses that one can generate? To answer this question, it is essential that the temporal attosecond pulses be accurately characterized. By reanalyzing the soft x-ray attosecond metrology reported in three recent experiments using a newly developed broadband phase retrieval algorithm, we demonstrate here that the generated attosecond pulses in the first two papers have durations of about 60 as, longer than what they have reported. Similarly, the duration from the third experiment is retrieved to be about half of the 322-as upper limit cited in that work. We also introduce the autocorrelation (AC) of the streaking spectrogram. By comparing the ACs from the experiments and from the retrieved SXR pulses, the accuracy of the retrieved results can be directly visualized. Our retrieval method is fast and accurate, and it shall provide a powerful tool for the metrology of the emerging few-ten-attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Removing Stripes, Scratches, and Curtaining with Nonrecoverable Compressed Sensing

Highly-directional image artifacts such as ion mill curtaining, mechanical scratches, or image striping from beam instability degrade the interpretability of micrographs. These unwanted, aperiodic features extend the image along a primary direction and occupy a small wedge of information in Fourier space. Deleting this wedge of data replaces stripes, scratches, or curtaining, with more complex streaking and blurring artifacts—known within the tomography community as “missing wedge” artifacts. Here, we overcome this problem by recovering the missing region using total variation minimization, which leverages image sparsity-based reconstruction techniques—colloquially referred to as compressed sensing (CS)—to reliably restore images corrupted by stripe-like features. Our approach removes beam instability, ion mill curtaining, mechanical scratches, or any stripe features and remains robust at low signal-to-noise. In conclusion, the success of this approach is achieved by exploiting CS's inability to recover directional structures that are highly localized and missing in Fourier Space.

47 OTHER INSTRUMENTATION↗

Investigation of heat transport using directly driven gold spheres

Recently, heat transport was investigated using a directly driven beryllium sphere [Farmer et al., Phys. Plasmas 27, 082701 (2020)]. Models that overly restrict heat transport were rejected. This paper extends work to directly driven gold spheres where radiation loss is more important. Here, gold coated spheres are directly driven at the OMEGA laser facility at intensities of 5×10 14 W/cm 2 . Plasma conditions, laser coupling, and x-ray flux are all measured. Additionally, comparisons to 2D radiation-hydrodynamic simulations are performed. Simulations use three common heat transport models: local transport with flux limiters of f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. It is shown that both the SNB model and f = 0.15 match the measured plasma conditions with the SNB model better capturing the temporal evolution of electron temperature. The f = 0.03 model predicts too low of an electron density and too hot of a temperature. The measured scattered light is roughly 6% of the incident energy, the f = 0.15 and SNB models predict 0.5% uncoupled light, and f = 0.03, 38% uncoupled light. The x-ray fluxes in the f = 0.15 and SNB simulations rise too quickly and are just outside the measurement's error, while the x-ray flux in the f = 0.03 simulation is low by a factor of two-three. For these reasons, the f = 0.03 model is rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗