Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Electron density profiles in the background of LF absorption during Forbush-decrease and PSE

Based on the simulation of different Forbush decrease and particle precipitation effects in the D region, electron density profiles in the mid-latitudes the ionospheric absorption of low frequency (LF) radio waves was determined. The absorption variations at different frequenceis are strongly affected by the shape of the electron density profile. A structure appears which sometimes resembles the letter S (in a sloping form). Both the height (around 70 to 72 km) and the depth of the local minimum in the electron density contribute to the computed absorption changes of various degree at different frequencies. In this way several observed special absorption events can be interpreted.

Satori, G.↗

Comparison of laser-produced plasma spatio-temporal electron density evolution measured using interferometry with simulation results

Due to the difficulties associated with experimental measurements of laser-produced plasma (LPP) properties during the earliest stages of plasma evolution, radiation hydrodynamic codes are often used. However, although these codes have been extensively validated in the higher intensity regimes, validation at low to moderate intensities has been limited. In this study, the spatio-temporal electron density evolution in an LPP generated at moderate laser intensities and at various laser wavelengths was validated against the FLASH code for times up to 20 ns. The LPP was generated by focusing the fundamental and various harmonics radiation (1064, 532, and 266 nm) from a 6 ns full width half maximum Nd:YAG laser, at a laser intensity of 10 GW cm -2 , onto a copper target. The spatio-temporal density evolution of the expanding plasma was analyzed using Nomarski interferometry. Experimental measurements were found to be consistent with FLASH simulations, and the dependence of electron densities on wavelength was found to be in agreement with analytical models, varying as n e ∝ λ -0.7 . However, slight differences were noted in the widths and shape functions of the experimental and simulated electron density profiles.

2D fast imaging↗

The Ionospheric Three-Dimensional Electron Density Variations Induced by the 21 August 2017 Total Solar Eclipse by Using Global Ionospheric Specification

Global Ionospheric Specification (GIS) is based on the Gauss–Markov Kalman filter to assimilate the slant total electron content (TEC) observed from ground-based GPS receivers and space-based radio occultation instrumentations in order to reconstruct three-dimensional (3D) ionospheric electron density structure, and it can remotely sense and monitor the weather condition in space. In this study, five minutes of high temporal resolution GIS is implemented in order to reconstruct the 3D electron density structure on the 21 August 2017 total solar eclipse and analyze the variations induced by the moon’s shadow. To obtain more information of the ionosphere, from the extend 2200 GPS stations on the continental United States, are added for assimilation. The results show the ionosphere peak height (hmF2) uplift was 30–50 km altitude in latitude 25–40°N, and that the electron density depletion at higher altitudes (400 km) has a more noticeable time delay than at low altitudes (200 km), especially in low-latitude regions.

Ionosphere↗

Electron density profiles from ionograms - Underlying ionization corrections and their comparison with rocket results

Electron density profiles from nine daytime rocket flights at Wallops Island, Va., conducted at high and low levels of solar activity are compared with profiles calculated by inversion of ionograms obtained at the same times and location. Sources of error and uncertainty in the ionogram inversion are discussed, as are means for their amelioration. In most cases, agreement between the two kinds of measurement within a few percent in electron density and within a few percent of a scale height can be achieved.

Wright, J. W.↗

Electron density modulation in a pulsed dual-frequency (2/13.56 MHz) dual-antenna inductively coupled plasma discharge

The electron density, n{sub e}, modulation is measured experimentally using a resonance hairpin probe in a pulsed, dual-frequency (2/13.56 MHz), dual-antenna, inductively coupled plasma discharge produced in argon-C{sub 4}F{sub 8} (90–10) gas mixtures. The 2 MHz power is pulsed at a frequency of 1 kHz, whereas 13.56 MHz power is applied in continuous wave mode. The discharge is operated at a range of conditions covering 3–50 mTorr, 100–600 W 13.56 MHz power level, 300–600 W 2 MHz peak power level, and duty ratio of 10%–90%. The experimental results reveal that the quasisteady state n{sub e} is greatly affected by the 2 MHz power levels and slightly affected by 13.56 MHz power levels. It is observed that the electron density increases by a factor of 2–2.5 on increasing 2 MHz power level from 300 to 600 W, whereas n{sub e} increases by only ∼20% for 13.56 MHz power levels of 100–600 W. The rise time and decay time constant of n{sub e} monotonically decrease with an increase in either 2 or 13.56 MHz power level. This effect is stronger at low values of 2 MHz power level. For all the operating conditions, it is observed that the n{sub e} overshoots at the beginning of the on-phase before relaxing to a quasisteady state value. The relative overshoot density (in percent) depends on 2 and 13.56 MHz power levels. On increasing gas pressure, the n{sub e} at first increases, reaching to a maximum value, and then decreases with a further increase in gas pressure. The decay time constant of n{sub e} increases monotonically with pressure, increasing rapidly up to 10 mTorr gas pressure and at a slower rate of rise to 50 mTorr. At a fixed 2/13.56 MHz power level and 10 mTorr gas pressure, the quasisteady state n{sub e} shows maximum for 30%–40% duty ratio and decreases with a further increase in duty ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time delay occultation data of the Helios spacecraft for probing the electron density distribution in the solar corona

S-band time delay measurements were collected from the spacecraft Helios A and B during three solar occultations in 1975/76 within heliocentric distances of about 3 and 215 earth radius in terms of range, Doppler frequency shift, and electron content. Characteristic features of measurement and data processing are described. Typical data sets are discussed to probe the electron density distribution near the sun (west and east limb as well) including the outer and extended corona. Steady-state and dynamical aspects of the solar corona are presented and compared with earth-bound-K-coronagraph measurements. Using a weighted least squares estimation, parameters of an average coronal electron density profile are derived in a preliminary analysis to yield electron densities at r = 3, 65, 215 earth radius. Transient phenomena are discussed and a velocity of propagation v is nearly equal to 900 km/s is determined for plasma ejecta from a solar flare observed during an extraordinary set of Helios B electron content measurements.

Edenhofer, P.↗

Use of micro-photoluminescence as a contactless measure of the 2D electron density in a GaAs quantum well

We compare micro-photoluminescence (μPL) as a measure of the electron density in a clean, two-dimensional (2D) system confined in a GaAs quantum well (QW) to the standard magneto-transport technique. Our study explores the PL shape evolution across a number of molecular beam epitaxy-grown samples with different QW widths and 2D electron densities and notes its correspondence with the density obtained in magneto-transport measurements on these samples. We also measure the 2D density in a top-gated quantum well sample using both PL and transport and find that the two techniques agree to within a few percent over a wide range of gate voltages. We find that the PL measurements are sensitive to gate-induced 2D density changes on the order of 109 electrons/cm 2 . The spatial resolution of the PL density measurement in our experiments is 40 μm, which is already substantially better than the millimeter-scale resolution now possible in spatial density mapping using magneto-transport. Our results establish that μPL can be used as a reliable high spatial resolution technique for future contactless measurements of density variations in a 2D electron system.

42 ENGINEERING↗

Surface loss rates of H and Cl radicals in an inductively coupled plasma etcher derived from time-resolved electron density and optical emission measurements

A study is undertaken of the loss kinetics of H and Cl atoms in an inductively coupled plasma (ICP) reactor used for the etching of III-V semiconductor materials. A time-resolved optical emission spectroscopy technique, also referred to as pulsed induced fluorescence (PIF), has been combined with time-resolved microwave hairpin probe measurements of the electron density in a pulsed Cl{sub 2}/H{sub 2}-based discharge for this purpose. The surface loss rate of H, k{sub w}{sup H}, was measured in H{sub 2} plasma and was found to lie in the 125-500 s{sup -1} range ({gamma}{sub H} surface recombination coefficient of {approx}0.006-0.023), depending on the reactor walls conditioning. The PIF technique was then evaluated for the derivation of k{sub w}{sup Cl}, and {gamma}{sub Cl} in Cl{sub 2}-based plasmas. In contrast to H{sub 2} plasma, significant variations in the electron density may occur over the millisecond time scale corresponding to Cl{sub 2} dissociation at the rising edge of the plasma pulse. By comparing the temporal evolution of the electron density and the Ar-line intensity curves with 10% of Ar added in the discharge, the authors show that a time-resolved actinometry procedure using Ar as an actinometer is valid at low to moderate ICP powers to estimate the Cl loss rate. They measured a Cl loss rate of {approx}125-200 s{sup -1} (0.03{<=}{gamma}{sub Cl}{<=}0.06) at 150 W ICP power for a reactor state close to etching conditions. The Cl surface loss rate was also estimated for high ICP power (800 W) following the same procedure, giving a value of {approx}130-150 s{sup -1} ({gamma}{sub Cl}{approx}0.04), which is close to that measured at 150 W ICP power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solar corona electron density distribution

The paper discusses the three and one-half months of single-frequency time delay data which were acquired from the Helios 2 spacecraft around the time of its solar occultation. The excess time delay due to integrated effect of free electrons along the signal's ray path could be separated and modeled following the determination of the spacecraft trajectory. An average solar corona and equatorial electron density profile during solar minimum were deduced from the time delay measurements acquired within 5-60 solar radii of the sun. As a point of reference at 10 solar radii from the sun, an average electron density was 4500 el/cu cm. However, an asymmetry was found in the electron density as the ray path moved from the west to east solar limb. This may be related to the fact that during entry into occultation the heliographic latitude of the ray path was about 6 deg, while during exit it was 7 deg. The Helios density model is compared with similar models deduced from different experimental techniques.

Esposito, P. B.↗

SU-F-J-162: Is Bulky Electron Density Assignment Appropriatefor MRI-Only Based Treatment Planning for Lung Cancer?

Purpose: To assess the appropriateness of bulky electron density assisment for MRI-only treatment planning for lung cancer via comparing dosimetric difference between MRI- and CT-based plans. Methods: Planning 4DCTs acquired for six representative lung cancer patients were used to generate CT-based IMRT plans. To avoid the effect of anatomic difference between CT and MRI, MRI-based plans were generated using CTs by forcing the relative electron density (rED) of organ specific values from ICRU report 46 and using the mean rED value of the internal target volume (ITV) of the patient for the ITV. Both CT and “MRI” plans were generated using a research planning system (Monaco, Elekta) employing Monte Carlo dose calculation the following dose-volume-parameters (DVPs): D99 – dose delivered to 99% of the ITV/PTV volume; D95; D5; D1; Vpd –volume receiving the prescription dose; V5 – volume of normal lung irradiated > 5 Gy; and V20. The percent point difference and dose difference was used for comparison for Vpd-V5-V20 and D99-D1, respectively. Four additional plans per patient were calculated with rEDITV = 0.6 and 1.0 and rEDlung = 0.1 and 0.5. Results: Noticeable differences in the ITV and PTV point doses and DVPs were observed. Variations in Vpd ranged from 0.0–6.4% and 0.32–18.3% for the ITV and PTV, respectively. The ITV and PTV variations in D99, D95, D5 and D1 were 0.15–3.2 Gy. The normal lung V5 & V20 variations were no larger than 1.9%. In some instances, varying the rEDITV between rEDmean, 0.6 and 1.0 resulted in D95 increases ranging from 3.9–6.3%. Uniform rED assignment on normal lung affected DVPs of ITV and PTV by 4.0–9.8% and 0.3–19.6%, respectively. Conclusion: The commonly-used uniform rED assignment in MRI-only based planning may not be appropriate for lung-cancer. A voxel based method, e.g. synthetic CT generated from MRI data, is required. This work was partially funded by Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

DFT studies of the electron density distribution and donor-acceptor interactions in water-soluble aminohydroximate metallamacrocyclic Ca{sup II} and Y{sup III} complexes

The topology of the electron density and the nature of donor-acceptor interactions in copper-based glycinehydroximate metallamacrocycles bearing calcium(II) and yttrium(III) have been studied for the first time in terms of the density functional theory (DFT). The DFT calculations at the M06/Def2-TZVP level were performed taking into account non-specific (PCM) and specific solvation. Quantitative estimations of the donor-acceptor interactions and topological properties of the electron density were obtained. According to them, the thermodynamic stability of the yttrium complex is higher than that of the calcium analog. The calculated values of the Gibbs energy changes indicate the spontaneous substitution of Ca{sup 2+} by Y{sup 3+} in the metallamacrocycle in an aqueous medium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionospheric electron density irregularities observed by satellite-to-satellite, dual-frequency, low-low Doppler tracking link

A low-low, satellite-to-satellite, dual-frequency, Doppler tracking experiment was performed. The data are analyzed here for irregularities in electron density at the altitude of 212 km. The differential Doppler data with the relative motion term removed are integrated to obtain a representation of the electron density variation along the satellite path. Well-known large-scale features such as the equatorial geomagnetic anomaly and day/night ionization level differences are clearly observed in the integrated data. The larger crest of the morning geomagnetic anomaly is seen to occur in the southern (winter) hemisphere in agreement with previous observations. In addition, a sharp peak in the electron density at the day-to-night transition point is observed in two consecutive revolutions. This effect may be due to the previously postulated atmospheric shock wave generated by supersonic motion of the terminator.

Estes, R. D.↗

Probing electron density across Ar{sup +} irradiation-induced self-organized TiO{sub 2−x} nanochannels for memory application

The variation of electron density in TiO{sub 2−x} nanochannels, exhibiting resistive switching phenomenon, produced by Ar{sup +} ion-irradiation at the threshold fluence of 5 × 10{sup 16} ions/cm{sup 2} is demonstrated by X-ray reflectivity (XRR). The transmission electron microscopy reveals the formation of nanochannels, while the energy dispersive X-ray spectroscopy confirms Ti enrichment near the surface due to ion-irradiation, in consistent with the increase in electron density by XRR measurements. Such a variation in Ti concentration indicates the evolution of oxygen vacancies (OVs) along the TiO{sub 2−x} nanochannels, and thus paves the way to explain the operation and performance of the Pt/TiO{sub 2−x}/Pt-based memory devices via OV migration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The electron density in the galactic center as derived from the S III 18.71/33.47 micron line ratio

High signal-to-noise ratio measurements of the S III lines 18.71 and 33.47 microns from the galactic center, Sgr A West, are reported. The average electron density is calculated for the S III-emitting region and is found to be 1800 + or - 500 per cu cm. This value is much less than the rms electron density of the clumps as derived from radio observations. The implications for various models are discussed. The S III result is consistent with the electron density previously derived from low signal-to-noise ratio measurements of the O III lines at 88 and 52 microns, if newer values are used for the O III atomic constants.

Herter, T.↗