Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Advanced Materials for Mercury 50 Gas Turbine Combustion System

Solar Turbines Incorporated (Solar), under cooperative agreement number DE-FC26-0CH11049, has conducted development activities to improve the durability of the Mercury 50 combustion system to 30,000 hours life and reduced life cycle costs. This project is part of Advanced Materials in the Advanced Industrial Gas Turbines program in DOE's Office of Distributed Energy. The targeted development engine was the Mercury{trademark} 50 gas turbine, which was developed by Solar under the DOE Advanced Turbine Systems program (DOE contract number DE-FC21-95MC31173). As a generator set, the Mercury 50 is used for distributed power and combined heat and power generation and is designed to achieve 38.5% electrical efficiency, reduced cost of electricity, and single digit emissions. The original program goal was 20,000 hours life, however, this goal was increased to be consistent with Solar's standard 30,000 hour time before overhaul for production engines. Through changes to the combustor design to incorporate effusion cooling in the Generation 3 Mercury 50 engine, which resulted in a drop in the combustor wall temperature, the current standard thermal barrier coated liner was predicted to have 18,000 hours life. With the addition of the advanced materials technology being evaluated under this program, the combustor life is predicted to be over 30,000 hours. The ultimate goal of the program was to demonstrate a fully integrated Mercury 50 combustion system, modified with advanced materials technologies, at a host site for a minimum of 4,000 hours. Solar was the Prime Contractor on the program team, which includes participation of other gas turbine manufacturers, various advanced material and coating suppliers, nationally recognized test laboratories, and multiple industrial end-user field demonstration sites. The program focused on a dual path development route to define an optimum mix of technologies for the Mercury 50 and future gas turbine products. For liner and injector development, multiple concepts including high thermal resistance thermal barrier coatings (TBC), oxide dispersion strengthened (ODS) alloys, continuous fiber ceramic composites (CFCC), and monolithic ceramics were evaluated before down-selection to the most promising candidate materials for field evaluation. Preliminary, component and sub-scale testing was conducted to determine material properties and demonstrate proof-of-concept. Full-scale rig and engine testing was used to validated engine performance prior to field evaluation at a Qualcomm Inc. cogeneration site located in San Diego, California. To ensure that the CFCC liners with the EBC proposed under this program would meet the target life, field evaluations of ceramic matrix composite liners in Centaur{reg_sign} 50 gas turbine engines, which had previously been conducted under the DOE sponsored Ceramic Stationary Gas Turbine program (DE-AC02-92CE40960), was continued under this program at commercial end-user sites under Program Subtask 1A - Extended CFCC Materials Durability Testing. The goal of these field demonstrations was to demonstrate significant component life, with milestones of 20,000 and 30,000 hours. Solar personnel monitor the condition of the liners at the field demonstration sites through periodic borescope inspections and emissions measurements. This program was highly successful at evaluating advanced materials and down-selecting promising solutions for use in gas turbine combustions systems. The addition of the advanced materials technology has enabled the predicted life of the Mercury 50 combustion system to reach 30,000 hours, which is Solar's typical time before overhaul for production engines. In particular, a 40 mil thick advanced Thermal Barrier Coating (TBC) system was selected over various other TBC systems, ODS liners and CFCC liners for the 4,000-hour field evaluation under the program. This advanced TBC is now production bill-of-material at various thicknesses up to 40 mils for all of Solar's advanced backside-cooled combustor liners (Centaur 50, Taurus 60, Mars 100, Taurus 70, Taurus 65, Titan 130, Titan 250 and Mercury 50). This TBC coating system significantly outperformed all other TBC systems evaluated under the program. The initial field unit, with the 40 mil advanced TBC developed under this program, has far exceeded the 4,000-hour requirement of the program, accumulating over 20,000 hours of commercial operation at Qualcomm Inc. in San Diego, CA. The 40 mil advanced TBC remains in excellent condition, with no evidence of chipping or spalling. The engine will continue operation until the unit is due for overhaul at approximately 30,000 hours. The Oxide Dispersion Strengthened (ODS) alloy injector tip testing and evaluation was also successful, however, the ODS injector tip development on this program was terminated, primarily due to the fact that the Mercury 50 injector tip was redesigned (Generation 3) by Combustion Engineering.

33 ADVANCED PROPULSION SYSTEMS↗

A method for extracting calibrated volatility information from the FIGAERO-HR-ToF-CIMS and its experimental application

The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.

47 OTHER INSTRUMENTATION↗

Vaporization of the group IVB metal carbides

High temperature vaporization of titanium, zirconium, hafnium and thorium carbides by Knudsen effusion mass spectrometry, measuring ion intensities, formation enthalpies and dissociation energies

Kohl, F. J.↗

Solid-gas phase equilibria and thermodynamic properties of cadmium selenide.

Accurate vapor pressures are determined through direct weight loss measurements using the Knudsen effusion technique. The experimental data are evaluated by establishing the mode of vaporization and determining the heat capacity of cadmium selenide at elevated temperatures. Additional information is obtained through a second- and third-law evaluation of data, namely, the heat of formation and the absolute entropy of cadmium selenide. A preferential loss of selenium during the initial heating of CdSe is observed, which leads to a deviation in stoichiometry.

Sigai, A. G.↗

Evaporation rate and vapor pressure of selected polymeric lubricating oils.

A recently developed ultrahigh-vacuum quartz spring mass sorption microbalance has been utilized to measure the evaporation rates of several low-volatility polymeric lubricating oils at various temperatures. The evaporation rates are used to calculate the vapor pressures by the Langmuir equation. A method is presented to accurately estimate extended temperature range evaporation rate and vapor pressure data for polymeric oils, incorporating appropriate corrections for the increases in molecular weight and the change in volatility of the progressively evaporating polymer fractions. The logarithms of the calculated data appear to follow linear relationships within the test temperature ranges, when plotted versus 1000/T. These functions and the observed effusion characteristics of the fluids on progressive volatilization are useful in estimating evaporation rate and vapor pressure changes on evaporative depletion.

Gardos, M. N.↗

Recognition of the geologic framework of porphyry deposits on ERTS-1 imagery

The author has identified the following significant results. Three major tectonic provinces have been mapped by geologic photointerpretation of ERTS-1 imagery over the Ok Tedi test site. These areas can be characterized as follows: (1) A broad area of low relief and mature topography suggesting a history of relative tectonic stability. (2) A narrow belt of moderate to high relief, broad open folds and prominent linear features. The Mount Fubilan-type porphyry copper deposits and recent volcanic effusive centers occur in this province. (3) A heterogeneous zone of high relief and high drainage density suggestive of relative structural complexity.

Wilson, J. C.↗

High-temperature mass spectrometry - Vaporization of group 4-B metal carbides

The high temperature vaporization of the metal-carbon systems TiC, ZrC, HfC, and ThC was studied by the Knudsen effusion - mass spectrometric method. For each system the metal dicarbide and tetracarbide molecular species were identified in the gas phase. Relative ion currents of the carbides and metals were measured as a function of temperature. Second- and third-law methods were used to determine enthalpies. Maximum values were established for the dissociation energies of the metal monocarbide molecules TiC, ZrC, HfC, and ThC. Thermodynamic functions used in the calculations are discussed in terms of assumed molecular structures and electronic contributions to the partition functions. The trends shown by the dissociation energies of the carbides of Group 4B are compared with those of neighboring groups and discussed in relation to the corresponding oxides and chemical bonding. The high temperature molecular beam inlet system and double focusing mass spectrometer are described.

Stearns, C. A.↗

The lunar atmosphere

In contrast to the earth's atmosphere, the atmosphere of the moon is exceedingly tenuous and appears to consist mainly of noble gases. The solar wind impinges on the lunar surface, supplying detectable amounts of helium, neon and Ar-36. Influxes of solar wind protons and carbon and nitrogen ions are significant, but atmospheric gases containing these elements have not been positively identified. Radiogenic Ar-40 and Rn-222 produced within the moon have been detected. The present rate of effusion of argon from the moon accounts for about 0.4% of the total production of Ar-40 due to decay of K-40 if the average abundance of potassium in the moon is 1000 ppm. Lack of weathering processes in the regolith suggests that most of the atmospheric Ar-40 originates deep in the lunar interior, perhaps in a partially molten core. If so, other gases may be vented along with the argon.

Hodges, R. R., Jr.↗

Some interesting aspects of physisorption stay-time measurements obtained using molecular-beam techniques

Stay-time distributions have been obtained for Xe physisorbing on polycrystalline nickel as a function of the target temperature using a pulsed molecular-beam technique. Some interesting effects due to ion bombardment of the surface using He, Ar, and Xe ions are presented. Measured detector signal shapes are found to deviate from those predicted for first-order desorption with velocities corresponding to Maxwellian effusion at the surface temperature. Evidence is found for interaction between beam pulse adsorption and steady-state adsorption of beam species background atoms.

Wilmoth, R. G.↗

Knudsen measurements of the sublimation and the heat of formation of GeSe

Knudsen effusion studies of the sublimation of polycrystalline GeSe have been performed employing mass spectrometry. The results demonstrate that GeSe vaporizes congruently under present experimental conditions according to the reaction: GeSe(s) yields GeSe(g). The mean values for the third-law heat and second-law entropy of reaction based on direct mass-loss data are 42.0 + or - 1.5 kcal/mole and 42.3 + or - 1.6 eu respectively. From these data the standard heat of formation was calculated to be -10.1 + or - 2.0 kcal/mole, and the standard absolute entropy was determined to be 16.9 + or - 2.0 eu.

Wiedemeier, H.↗

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.↗