Analysis of two alternate damping systems for GEOS gravity gradient stabilized satellite
Magnetically anchored eddy current and eddy current rod dampers for GEOS gravity gradient stabilized satellite
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Magnetically anchored eddy current and eddy current rod dampers for GEOS gravity gradient stabilized satellite
The Alpha Magnetic Spectrometer-02 (AMS-02) is an experiment that will be flown as an attached payload on the International Space Station to detect dark matter and antimatter. It uses large superconducting magnets cooled with superfluid helium to bend the path of cosmic particles through a series of detectors, which then measure the mass, speed, charge, and direction of the particles. Four Sunpower M87N Stirling-cycle cryocoolers are used to extend the mission life by cooling the outer vapor-cooled shield of the dewar. The main magnet coils are separated by a distance of approximately 1 m and the coolers are located approximately 1.5 m from the center line of the magnet, where the field is as high as 925 gauss perpendicular to the cryocooler axis and 400 gauss along the cryocooler axis. Interactions between the applied magnetic field and the linear motor may result in additional forces and torques on the compressor piston. Motion of the compressor arid displacer pistons through the magnetic field spatial gradients will generate eddy currents. Additional eddy currents are created during magnet charge, discharge, and quench by the time-varying magnetic field. The results of tests to determine the magnitude of the forces, torques, and heating effects, as well as the need for additional magnetic shielding, are presented.
The paper discusses development of various NDE techniques to detect cracks in A40 steel poppets used in a valve of the fuel system of the Space Shuttle Orbiter. The valve assembly experiences a severe high cycle fatigue environment during its operation. Cracks were discovered at the radius of the poppet flange. Experience shows that very small cracks or material anomalies do not cause failure in a single operation event. While the design is being modified to eliminate the issue, NDE has been used to screen the poppets for cracks before every use. Several surface flaw detection techniques were considered and a few NDE techniques were developed to provide NDE screening for the flaw detection. The primary method used was the eddy current testing. In the eddy current technique, the X-Y channel test data from the eddy current instrument was recorded as computer files. A Matlab data review and plotting application was developed to analyze the data files. The Matlab application provides much higher resolution than the eddy current instrument that was used to acquire the data. Other techniques that were used included ultrasonic surface wave and magnetic particle testing. A probability of detection (POD) study was undertaken to determine the 90/95 size for the eddy current technique. This study used specimens with same geometry and material as the poppet. Fatigue cracks were grown in these specimens. Information on results of the NDE techniques and results of the POD study are provided.
Highlights: Black-Right-Pointing-Pointer A new sensor system is developed for metal grade measurement of falling bottom ash particles. Black-Right-Pointing-Pointer The system is hybrid, consisting of an optical and an electromagnetic sensor. Black-Right-Pointing-Pointer Grade of ECS concentrated bottom ash in 1-6 mm sieve size accurately measured up to 143 p/s feed rate. Black-Right-Pointing-Pointer Accuracy reached was 2.4% with respect to manual analysis. Black-Right-Pointing-Pointer Measures for elimination of both stationary and stochastic errors are discussed. - Abstract: A hybrid sensor system for accurate detection of the metal grade of a stream of falling solid waste particles is investigated and experimentally verified. The system holds an infrared and an electromagnetic unit around a central tube and counts all the particles and only the metal particles, respectively. The count ratio together with the measured average particle mass ratio (k) of non-metal and metal particles is sufficient for calculation of grade. The performance of the system is accurately verified using synthetic mixtures of sand and metal particles. Towards an application a case study is performed using municipal solid waste incineration bottom ash in size fractions 1-6 mm, which presents a major challenge for nonferrous metal recovery. The particle count ratio was inherently accurate for particle feed rates up to 13 per second. The average value and spread of k for bottom ash was determined as 0.49 {+-} 0.07 and used to calculate grade within 2.4% from the manually analysed grade. At higher feed rates the sensors start missing particles which fall simultaneously through the central tube, but the hybrid system still counted highly repeatable. This allowed for implementation of a count correction ratio to eliminate the stationary error. In combination with averaging in measurement intervals for suppression of stochastic variations the hybrid system regained its accuracy for particle feed rates up to 143 per second. This performance and its special design, intended to render it insensitive to external interference and noise when applied in an eddy current separator, make the hybrid sensor suitable for applications such as quality control and sensor controlled separation.
Code Validation is a permanent concern in computer simulation, and has been addressed repeatedly in eddy current and ultrasonic modelling. A good benchmark problem is sufficiently simple to be taken into account by various codes without strong requirements on geometry representation capabilities, focuses on few or even a single aspect of the problem at hand to facilitate interpretation and to avoid that compound errors compensate themselves, yields a quantitative result and is experimentally accessible. In this paper we attempt to address code validation for one aspect of radio-graphic modelling, the scattered radiation prediction. An update of the results of the 2008 benchmark is presented. Additionally we discuss the extension of this benchmark on the lower energy part for 60 and 80 keV as well as for higher energies up to 10 MeV to study the contribution of pair production. Of special interest will be the primary radiation (attenuation law as reference), the total scattered radiation, the relative contribution of scattered radiation separated by order of scatter events (1st, 2nd, ..., 20th), and the spectrum of scattered radiation. We present the results of three Monte Carlo codes (MC-Ray, Sindbad and Moderato) as well as an analytical first order scattering code (VXI) and compare to MCNP as reference.
To ascertain whether magnetic dynamos operate in rocky exoplanets more massive or hotter than the Earth, we developed a parametric model of a differentiated rocky planet and its thermal evolution. Our model reproduces the established properties of Earth's interior and magnetic field at the present time. When applied to Venus, assuming that planet lacks plate tectonics and has a dehydrated mantle with an elevated viscosity, the model shows that the dynamo shuts down or never operated. Our model predicts that at a fixed planet mass, dynamo history is sensitive to core size, but not to the initial inventory of long-lived, heat-producing radionuclides. It predicts that rocky planets larger than 2.5 Earth masses will not develop inner cores because the temperature-pressure slope of the iron solidus becomes flatter than that of the core adiabat. Instead, iron 'snow' will condense near or at the top of these cores, and the net transfer of latent heat upward will suppress convection and a dynamo. More massive planets can have anemic dynamos due to core cooling, but only if they have mobile lids (plate tectonics). The lifetime of these dynamos is shorter with increasing planet mass but longer with higher surface temperature. Massive Venus-like planets with stagnant lids and more viscous mantles will lack dynamos altogether. We identify two alternative sources of magnetic fields on rocky planets: eddy currents induced in the hot or molten upper layers of planets on very short-period orbits, and dynamos in the ionic conducting layers of 'ocean' planets with {approx}10% mass in an upper mantle of water (ice).
The presentation examines the background and objective of nondestructive crack detection, flow control valve assembly and poppet post flight evaluation, poppet properties. magnetic property characterization of lab data, NDE, eddy current inspection, simulation, eddy current criteria, poppet cycle testing and NDE criteria, and the use of ultrasonic surface wave for crack detection.
A new computational method for characterizing the relationship between surface crystallography and electrical conductivity in anisotropic materials with low frequency electromagnetic techniques is presented. The method is discussed from the standpoint of characterizing the orientation of a single grain, as well as characterizing statistical information about grain ensembles in the microstructure. Large-area electron backscatter diffraction (EBSD) data was obtained and used in conjunction with a synthetic aperture approach to simulate the eddy current response of beta annealed Ti-6Al-4V. Experimental eddy current results are compared to the computed eddy current approximations based on electron backscatter diffraction (EBSD) data, demonstrating good agreement. The detectability of notches in the presence of noise from microstructure is analyzed with the described simulation method and advantages and limitations of this method are discussed relative to other NDE techniques for such analysis.
Imaging station for detecting cracks and flaws in solid materials developed combining both ultrasonic C-scan and eddy-current imaging. Incorporation of both techniques into one system eliminates duplication of computers and of mechanical scanners; unifies acquisition, processing, and storage of data; reduces setup time for repetitious ultrasonic and eddy-current scans; and increases efficiency of system. Same mechanical scanner used to maneuver either ultrasonic or eddy-current probe over specimen and acquire point-by-point data. For ultrasonic scanning, probe linked to ultrasonic pulser/receiver circuit card, while, for eddy-current imaging, probe linked to impedance-analyzer circuit card. Both ultrasonic and eddy-current imaging subsystems share same desktop-computer controller, containing dedicated plug-in circuit boards for each.
The inspection of weldments in critical pressure vessel joints is a major concern in the nuclear power industry. Corrosive environments can speed the fatigue process and access to the critical area is often limited. Eddy current techniques have begun to be used to help overcome these obstacles [1]. As direct contact and couplants are not required, remote areas can be inspected by simply snaking an eddy current coil into the intake tube of the vessel. The drawback of the eddy current method has been the high sensitivity to small changes in the conductivity and permeability of the test piece which are known to vary at weldments [1]. The flaw detection mechanism of the flux focusing electromagnetic probe can help alleviate these difficulties and provide a unique capability for detecting longitudinal fatigue cracks in critical tube structures. The Flux Focusing Electromagnetic Flaw Detector, originally invented for the detection of fatigue and corrosion damage in aluminum plates [2-3], has been adapted for use in testing steel tubing for longitudinal fatigue cracks. The modified design allows for the probe to be placed axisymmetrically into the tubing, inducing eddy currents in the tube wall. The pickup coil of the probe is fixed slightly below the primary windings and is rotated 90 so that its axis is normal to the tube wall. The magnetic flux of the primary coil is focused through the use of ferromagnetic material so that in the absence of fatigue damage there will be no flux linkage with the pickup coil. The presence of a longitudinal fatigue crack will cause the eddy currents induced in the tube wall to flow around the flaw and directly under the pickup coil. The magnetic field associated with these currents will then link the pickup coil and an unambiguous increase in the output voltage of the probe will be measured. The use of the flux focusing electromagnetic probe is especially suited for the detection of flaws originating at or near tube welds. The probe is shown to discriminate against signals due solely to the weld joint so that flaw signals are not hidden in the background in these locations. Experimental and finite element modeling results are presented for the flaw detection capabilities of the probe in stainless steel tubes.
One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.
Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.
A method of fabricating improved transformer cores from composites of thermoplastic matrices and iron-particles has been invented. Relative to commercially available laminated-iron-alloy transformer cores, the cores fabricated by this method weigh less and are less expensive. Relative to prior polymer-matrix/ iron-particle composite-material transformer cores, the cores fabricated by this method can be made mechanically stronger and more magnetically permeable. In addition, whereas some prior cores have exhibited significant eddy-current losses, the cores fabricated by this method exhibit very small eddy-current losses. The cores made by this method can be expected to be attractive for use in diverse applications, including high-signal-to-noise transformers, stepping motors, and high-frequency ignition coils. The present method is a product of an experimental study of the relationships among fabrication conditions, final densities of iron particles, and mechanical and electromagnetic properties of fabricated cores. Among the fabrication conditions investigated were molding pressures (83, 104, and 131 MPa), and molding temperatures (250, 300, and 350 C). Each block of core material was made by uniaxial-compression molding, at the applicable pressure/temperature combination, of a mixture of 2 weight percent of LaRC (or equivalent high-temperature soluble thermoplastic adhesive) with 98 weight percent of approximately spherical iron particles having diameters in the micron range. Each molded block was cut into square cross-section rods that were used as core specimens in mechanical and electromagnetic tests. Some of the core specimens were annealed at 900 C and cooled slowly before testing. For comparison, a low-carbon-steel core was also tested. The results of the tests showed that density, hardness, and rupture strength generally increased with molding pressure and temperature, though the correlation was rather weak. The weakness of the correlation was attributed to the pores in the specimens. The maximum relative permeabilities of cores made without annealing ranged from 30 to 110, while those of cores made with annealing ranged from 900 to 1,400. However, the greater permeabilities of the annealed specimens were not associated with noticeably greater densities. The major practical result of the investigation was the discovery of an optimum distribution of iron-particle sizes: It was found that eddy-current losses in the molded cores were minimized by using 100 mesh (corresponding to particles with diameters less than or equal to 100 m) iron particles. The effect of optimization of particle sizes on eddy-current losses is depicted in the figure.
Shell and tube heat exchangers (STHEs) are critical to energy conversion efficiency of power plants. Eddy current examination is a way to evaluate working conditions of these tubes. However, the current testing apparatus requires human to manually insert an eddy current testing (ECT) probe into and extract it out of individual tubes, and meanwhile monitor measurement results for diagnosis. It is a time-consuming and labor-intensive procedure even for an experienced technician. To tackle this challenge, in this study, we developed a robot enabled ECT system for autonomous inspection of STHEs. The robotic platform employs Mecanum wheeled chassis for high mobility, machine vision to locate tube bundle and tube inlets, a rotational Cartesian mechanism to operate at planes with all possible inclinations, and a task-specific mechanism for ECT probe delivery. Machine vision locates tube bundle and tube inlets by an April tag detection algorithm and a Circle Hough Transform algorithm, respectively. Assisted by a guiding cone, the ECT probe is continuously fed into the tubes with a fill factor of 0.819. In conclusion, during this process, the eddy current data are automatically collected and real-time analyzed by convolutional neural networks, showing accuracy of nearly 100% for identifying defective and nondefective tubes and 85% for four types of defective tubes and nondefective tubes.
Shell and tube heat exchangers (STHEs) are critical to energy conversion efficiency of power plants. Eddy current examination is a way to evaluate working conditions of these tubes. However, the current testing apparatus requires human to manually insert an eddy current testing (ECT) probe into and extract it out of individual tubes, and meanwhile monitor measurement results for diagnosis. It is a time-consuming and labor-intensive procedure even for an experienced technician. To tackle this challenge, in this work, we developed a robot enabled ECT system for autonomous inspection of STHEs. The robotic platform employs Mecanum wheeled chassis for high mobility, machine vision to locate tube bundle and tube inlets, a rotational Cartesian mechanism to operate at planes with all possible inclinations, and a task-specific mechanism for ECT probe delivery. Machine vision locates tube bundle and tube inlets by an April tag detection algorithm and a Circle Hough Transform (CHT) algorithm, respectively. Assisted by a guidance cone, the ECT probe is continuously fed into the tubes with a fill factor of 0.819. During this process, the eddy current data are automatically collected and real-time analyzed by convolutional neural networks (CNN), showing accuracy of nearly 100% for identifying defective and non-defective tubes and 85% for four types of defective tubes and non-defective tubes.
The Large Angle Magnetic Suspension Test Fixture (LAMSTF) is a laboratory scale proof-of-concept system. The configuration is unique in that the electromagnets are mounted in a circular planar array. A mathematical model of the system had previously been developed, but was shown to have inaccuracies. These inaccuracies showed up in the step responses. Eddy currents were found to be the major cause of the modeling errors. In the original system, eddy currents existed in the aluminum baseplate, iron cores, and the sensor support frame. An attempt to include the eddy current dynamics in the system model is presented. The dynamics of a dummy sensor ring were added to the system. Adding the eddy current dynamics to the simulation improves the way it compares to the actual experiment. Also presented is a new method of determining the yaw angle of the suspended element. From the coil currents the yaw angle can be determined and the controller can be updated to suspend at the new current. This method has been used to demonstrate a 360 degree yaw angle rotation.
DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.
Powerpoint presentation on Ultrasonic and Eddy Current NDT; UT Theory; Eddy current (ECA): How it works; Controlled Corrosion at NM Tech; Results – HCl Corrosion; Waveform Data for 10M HCl; Accuracy Statistics; Results – FeCl 3 Pitting; Waveforms for Anhydrous FeCl 3 ; Analyzing Corroded Stainless Steel 316L Plates; 316L Plate to Imitate Pitting; ECA Pit Depth Calibration Curve; C Scan Imaging; UT Pit Detection; SST Containers: Ultrasonic (UT) vs. CMM; UT Data Analysis; UT Conclusions and Observations; ECA Conclusions; Automated System Vision.