Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Neptune Aerocapture Systems Analysis

A Neptune Aerocapture Systems Analysis is completed to determine the feasibility, benefit and risk of an aeroshell aerocapture system for Neptune and to identify technology gaps and technology performance goals. The high fidelity systems analysis is completed by a five center NASA team and includes the following disciplines and analyses: science; mission design; aeroshell configuration screening and definition; interplanetary navigation analyses; atmosphere modeling; computational fluid dynamics for aerodynamic performance and database definition; initial stability analyses; guidance development; atmospheric flight simulation; computational fluid dynamics and radiation analyses for aeroheating environment definition; thermal protection system design, concepts and sizing; mass properties; structures; spacecraft design and packaging; and mass sensitivities. Results show that aerocapture can deliver 1.4 times more mass to Neptune orbit than an all-propulsive system for the same launch vehicle. In addition aerocapture results in a 3-4 year reduction in trip time compared to all-propulsive systems. Aerocapture is feasible and performance is adequate for the Neptune aerocapture mission. Monte Carlo simulation results show 100% successful capture for all cases including conservative assumptions on atmosphere and navigation. Enabling technologies for this mission include TPS manufacturing; and aerothermodynamic methods and validation for determining coupled 3-D convection, radiation and ablation aeroheating rates and loads, and the effects on surface recession.

Lockwood, Mary Kae↗

Ascent Heating Thermal Analysis on Spacecraft Adaptor Fairings

When the Crew Exploration Vehicle (CEV) is launched, the spacecraft adaptor (SA) fairings that cover the CEV service module (SM) are exposed to aero heating. Thermal analysis is performed to compute the fairing temperatures and to investigate whether the temperatures are within the material limits for nominal ascent aeroheating case. The ascent heating is analyzed by using computational fluid dynamics (CFD) and engineering codes at Marshall Space Flight Center. The aeroheating environment data used for this work is known as Thermal Environment 3 (TE3) heating data. One of the major concerns is with the SA fairings covering the CEV SM and the SM/crew launch vehicle (CLV) flange interface. The TE3 heating rate is a function of time, wall temperature, and the spatial locations. The implementation of the TE3 heating rate as boundary conditions in the thermal analysis becomes challenging. The ascent heating thermal analysis on SA fairings and SM/CLV flange interface are performed using two commercial software packages: Cullimore & Ring (C&R) Thermal Desktop (TD) 5.1 and MSC Patran 2007r1 b. TD is the pre-and post-processor for SINDA, which is a finite-difference-based solver. In TD, the geometry is built and meshed, the boundary conditions are defined, and then SINDA is used to compute temperatures. MSC Pthermal is a finite-element- based thermal solver. MSC Patran is the pre- and post-processor for Pthermal. Regarding the boundary conditions, the convection, contact resistance, and heat load can be imposed in different ways in both programs. These two software packages are used to build the thermal model for the same analysis to validate each other and show the differences in the modeling details.

Wang, Xiao Yen↗

Powerpack Testing of the J2-X Oxidizer Turbopump

The J-2X PPA-2 (Powerpack 2) test series was conducted from February through December 2012 on the A1 test stand at NASA Stennis Space Center in a joint effort between Pratt and Whitney Rocketdyne (PWR) and NASA Marshall Space Flight Center (MSFC). The series consisted of 13 tests for a total hotfire duration close to 6500 seconds. Among the chief test objectives was characterization of the capabilities of the new J-2X turbopumps. This paper concentrates on the test results pertaining specifically to the Oxidizer Turbopump (OTP) operation in liquid oxygen (LOX). The two bladed inducer configuration that was tested had a 0.81% blade height tip clearance and incorporated the B-groove modification to the inducer tunnel outboard of the inducer leading edge. Data was collected on inducer suction performance, pump radial loading, and the pump dynamic environment in LOX. Comparisons were made to prior data collected on two geometrically similar subscale inducers tested in water at NASA MSFC (70% scale) and Concepts NREC (52% scale). In overview, the results of the powerpack testing were consistent with the radial load assessment from the water tests. The inducer performed differently in the other two categories, however. The inducer suction performance capability in LOX was notably improved. This was expected and is probably attributable to thermal suppression head (TSH) effects. While the dynamic environment was similar in most aspects to water test observations, the higher order cavitation (HOC) during the powerpack testing was much more benign.

Jambusaria, Mitul↗

GOES-R Spacecraft Verification and Validation Compared with Flight Results

The Geostationary Operational Environmental Satellite, R-Series (GOES-R) represents a dramatic improvement in GEO (Geostationary Earth Orbit) weather observation capabilities over the previous generation. To provide these new capabilities, GOES-R incorporates a number of new technologies flying for the first time. As with any new spacecraft design, extensive ground testing was performed to validate the vehicle performance. In this paper, we present several successes and several lessons-learned from the GOES-R verification and validation (V&V) efforts. Included are the Dynamic Interaction Test (DIT) results for jitter assessment, and comparison to flight results. Also included are the effects of thermally-induced alignment perturbations, along with post-launch mitigations. Finally, we discuss unexpected GOES-17 gyro performance, which caused a Safe Mode entry shortly after launch. V&V mitigations are presented, which will be used for the next two GOES-R vehicles.

GOES-17↗

Synthesis of magnesiowüstite nanocrystallites embedded in an amorphous silicate matrix via low energy multiple ion implantations

The synthesis process is presented for experimentally simulating modifications in cosmic dust grains using sequential ion implantations or irradiations followed by thermal annealing. Cosmic silicate dust analogues were prepared via implantation of 20–80 keV Fe - , Mg - , and O - ions into commercially available p-type silicon (100)wafers. The as-implanted analogues are amorphous with a Mg/(Fe+Mg) ratio of 0.5 tailored to match theoretical abundances in circumstellar dusts. Before the ion implantations were performed, Monte-Carlo-based ion-solid interaction codes were used to model the dynamic redistribution of the implanted atoms in the silicon substrate. 600 keV helium ion irradiation was performed on one of the samples before thermal annealing. Two samples were thermally annealed at a temperature appropriate for an M-class stellar wind, 1000 K, for 8.3 h in a vacuum chamber with a pressure of 1 x 10 -7 torr. The elemental depth profiles were extracted utilizing Rutherford Backscattering Spectrometry (RBS) in the samples before and after thermal annealing. X-ray diffraction (XRD)analysis was employed for the identification of various phases in crystalline minerals in the annealed analogues. Transmission electron microscopy (TEM) analysis was utilized to identify specific crystal structures. RBS analysis shows redistribution of the implanted Fe, Mg, and O after thermal annealing due to incorporation into the crystal structures for each sample type. XRD patterns along with TEM analysis showed nanocrystalline Mg and Fe oxides with possible incorporation of additional silicate minerals.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Physical Security Risk for Potential Implementation of FLEX using Dynamic Simulation Methods

The requirements for United States nuclear power plants to maintain a large onsite physical security force contribute to their large operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability Program Physical Security Pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. This pathway will analyze and minimize the conservatisms built into current security postures in order to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within this pathway has successfully developed a dynamic force-on-force (FOF) modeling framework using various computer simulation tools and integrated them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This document provides an overview of lessons learned in applying a dynamic computational framework that links results from a commercially available FOF simulation tool, a commercially available thermal-hydraulic tool, and EMRALD to an operating commercial nuclear power plant. This process of including plant procedures and multiple analysis results is being called Modeling and Analysis for Safety Security using Dynamic EMRALD Framework. Previous reports described how a user could integrate their plant-specific FOF models with the dynamic simulation tool EMRALD, model operator actions, integrate with probabilistic risk assessment tools, such as Computer Aided Fault Tree Analysis System or Systems Analysis Programs for Hands-on Integrated Reliability Evaluations, and with thermal-hydraulic tools, such as RELAP-5. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report documents the results of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. The purpose of this study was to verify that results achieved using generic models are similar to actual plant results and to refine our guidance of the use of the framework. Such an assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants. NOTE: The work performed in this report is based on a generic EMRALD model with actual plant data used for the analysis. However, only the generic model and general results of the analysis are in the report. No plant’s sensitive information is discussed in this report. The discussion shows examples of insights that can be obtained from the MASS-DEF methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic and thermal analysis of high speed tapered roller bearings under combined loading

The development of a computer program capable of predicting the thermal and kinetic performance of high-speed tapered roller bearings operating with fluid lubrication under applied axial, radial and moment loading (five degrees of freedom) is detailed. Various methods of applying lubrication can be considered as well as changes in bearing internal geometry which occur as the bearing is brought to operating speeds, loads and temperatures.

Crecelius, W. J.↗

Parametric Analytical Studies for the Nonlinear Dynamic Response of the Tile/Pad Space Shuttle Thermal Protection System

The studies examined for imposed sinusoidal and random motions of the shuttle skin and/or applied tile pressure. Studies are performed using the computer code DYNOTA which takes into account the highly nonlinear stiffening hysteresis and viscous behavior of the pad joining the tile to the shuttle skin. Where available, experimental data are used to confirm the validity of the analysis. Both analytical and experimental studies reveal that the system resonant frequency is very high for low amplitude oscillations but decreases rapidly to a minimum value with increasing amplitude.

Edighoffer, H.↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Sustainable Functional Epoxies through Boric Acid Templating

Thermoset polymers (e.g. epoxies, vulcanizable rubbers, polyurethanes, etc.) are crosslinked materials with excellent thermal, chemical, and mechanical stability; these properties make thermoset materials attractive for use in harsh applications and environments. Unfortunately, material robustness means that these materials persist in the environment with very slow degradation over long periods of time. Balancing the benefits of material performance with sustainability is a challenge in need of novel solutions. Here, we aimed to address this challenge by incorporating boronic acid-amine complexes into epoxy thermoset chemistries, facilitating degradation of the material under pH neutral to alkaline conditions; in this scenario, water acts as an initiator to remove boron species, creating a porous structure with an enhanced surface area that makes the material more amenable to environmental degradation. Furthermore, the expulsion of the boron leaves the residual pores rich in amines which can be exploited for CO 2 absorption or other functionalization. We demonstrated the formation of novel boron species from neat mixing of amine compounds with boric acid, including one complex that appears highly stable under nitrogen atmosphere up to 600 °C. While degradation of the materials under static, alkaline conditions (our “trigger”) was inconclusive at the time of this writing, dynamic conditions appeared more promising. Additionally, we showed that increasing boronic acid content created materials more resistant to thermal degradation, thus improving performance under typical high temperature use conditions.

36 MATERIALS SCIENCE↗

Exceptional Radiation Absorption in a Pentagon-Based Si Allotrope

Excellent photovoltaic performance is predicted in a pentagonal covalent network of Si in a hollow structure exhibiting both thermal and dynamical stability. Consisting of a combination of sp 2 and sp 3 hybridized Si atomic orbitals, the GW0 computed band structure shows an indirect band gap near the zone edge and also a manifold of directly absorbing transitions at frequencies in the window of visible light, in distinction with conventional Si. Hydrogenation of a single sp 2 site is predicted to lead to a robust local magnetic moment. In this study, we find a low formation energy at low pressure that is compatible with other experimentally known phases, suggesting that a stable phase might be obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

Solar dynamic power system definition study

The solar dynamic power system design and analysis study compared Brayton, alkali-metal Rankine, and free-piston Stirling cycles with silicon planar and GaAs concentrator photovoltaic power systems for application to missions beyond the Phase 2 Space Station level of technology for all power systems. Conceptual designs for Brayton and Stirling power systems were developed for 35 kWe and 7 kWe power levels. All power systems were designed for 7-year end-of-life conditions in low Earth orbit. LiF was selected for thermal energy storage for the solar dynamic systems. Results indicate that the Stirling cycle systems have the highest performance (lowest weight and area) followed by the Brayton cycle, with photovoltaic systems considerably lower in performance. For example, based on the performance assumptions used, the planar silicon power system weight was 55 to 75 percent higher than for the Stirling system. A technology program was developed to address areas wherein significant performance improvements could be realized relative to the current state-of-the-art as represented by Space Station. In addition, a preliminary evaluation of hardenability potential found that solar dynamic systems can be hardened beyond the hardness inherent in the conceptual designs of this study.

Wallin, Wayne E.↗

An Experimental and Numerical Study of a Supersonic Burner for CFD Model Development

A laboratory scale supersonic burner has been developed for validation of computational fluid dynamics models. Detailed numerical simulations were performed for the flow inside the combustor, and coupled with finite element thermal analysis to obtain more accurate outflow conditions. A database of nozzle exit profiles for a wide range of conditions of interest was generated to be used as boundary conditions for simulation of the external jet, or for validation of non-intrusive measurement techniques. A set of experiments was performed to validate the numerical results. In particular, temperature measurements obtained by using an infrared camera show that the computed heat transfer was larger than the measured value. Relaminarization in the convergent part of the nozzle was found to be responsible for this discrepancy, and further numerical simulations sustained this conclusion.

Magnotti, G.↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗