Compact Radiative Control Structures for Millimeter Astronomy

We have designed, fabricated, and tested compact radiative control structures, including antireflection coatings and resonant absorbers, for millimeter through submillimeter wave astronomy. The antireflection coatings consist of micromachined single crystal silicon dielectric sub-wavelength honeycombs. The effective dielectric constant of the structures is set by the honeycomb cell geometry. The resonant absorbers consist of pieces of solid single crystal silicon substrate and thin phosphorus implanted regions whose sheet resistance is tailored to maximize absorption by the structure. We present an implantation model that can be used to predict the ion energy and dose required for obtaining a target implant layer sheet resistance. A neutral density filter, a hybrid of a silicon dielectric honeycomb with an implanted region, has also been fabricated with this basic approach. These radiative control structures are scalable and compatible for use large focal plane detector arrays.

Brown, Ari D.↗

Optical Transmission Characterization of Fused Silica Materials Irradiated at the CERN Large Hadron Collider

The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. This campaign took place during the Run 2 p+p data taking, which occurred between 2016 and 2018. This paper reports a complete characterization of optical transmission per unit length of irradiated fused silica materials as a function of wavelength (240 nm - 1500 nm), dose (up to 18 MGy), and level of OH and H$_2$ dopants introduced in the manufacturing process. The dose delivered to the rods was estimated using Monte Carlo simulations performed by the CERN FLUKA team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

Shield weight optimization using Monte Carlo transport calculations

Outlines are given of the theory used in FASTER-3 Monte Carlo computer program for the transport of neutrons and gamma rays in complex geometries. The code has the additional capability of calculating the minimum weight layered unit shield configuration which will meet a specified dose rate constraint. It includes the treatment of geometric regions bounded by quadratic and quardric surfaces with multiple radiation sources which have a specified space, angle, and energy dependence. The program calculates, using importance sampling, the resulting number and energy fluxes at specified point, surface, and volume detectors. Results are presented for sample problems involving primary neutron and both primary and secondary photon transport in a spherical reactor shield configuration. These results include the optimization of the shield configuration.

Jordan, T. M.↗

Code CUGEL: A code to unfold Ge(Li) spectrometer polyenergetic gamma photon experimental distributions

A FORTRAN code was developed for the Univac 1108 digital computer to unfold lithium-drifted germanium semiconductor spectrometers, polyenergetic gamma photon experimental distributions. It was designed to analyze the combination continuous and monoenergetic gamma radiation field of radioisotope volumetric sources. The code generates the detector system response matrix function and applies it to monoenergetic spectral components discretely and to the continuum iteratively. It corrects for system drift, source decay, background, and detection efficiency. Results are presented in digital form for differential and integrated photon number and energy distributions, and for exposure dose.

Steyn, J. J.↗

Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

Zhou, Dazhuang↗

Dosimetric mapping inside biorack (7-IML-1)

This experiment documents the radiation environment inside Biorack and compares it to theoretical predictions. Other experiments inside Biorack need this information to determine whether changes to samples are caused by radiation or microgravity. Dosimetric stacks, each with 20 to 100 sheets of plastic detector foils (cellulose nitrate, Lexan, and CR39) and nuclear emulsions of different radiation sensitivity are packed together with Thermoluminescence dosimeters (TLD) inside Type 1 containers. Crew members place two stacks in the 37 C incubator and four in the 36 C incubator, two of which are placed on the 1 g centrifuge. Two stacks are located in a stowage position at ambient temperature. After the mission, the plastic detectors are etched and the nuclear emulsions are developed similar to photographic emulsions. The traces resulting from the interaction of heavy ions with matter can then be evaluated under the microscope. The number, charge, and energy of the particles will be determined. From the TLD readings, the absorbed dose of the low LET components will be received.

Reitz, G.↗

First Results from the ISS-RAD Charged Particle Detector

The Charged Particle Detector (CPD) subsystem of the ISS-RAD detector has been making measurements of high-energy charged and neutral particles since the unit was deployed on Feb. 1, 2016. The CPD is nearly identical to the MSL-RAD instrument, but onboard data processing has been significantly modified to meet ISS requirements. We will present dose rates and LET spectra obtained over the first six months of operations, as well as preliminary results obtained from the limited sample of pulse-height analyzed raw data that has been telemetered to Earth.

Semones, Edward↗

Active dosimetric measurements on Shuttle flights

A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of LET and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 deg x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.

Badhwar, Gautam D.↗

Native Fluorescence Detection Methods and Detectors for Naphthalene and/or Other Volatile Organic Compound Vapors

Naphthalene, benzene, toluene, xylene, and other volatile organic compounds have been identified as serious health hazards. This is especially true for personnel working with JP8 jet fuel and other fuels containing naphthalene as well as other hazardous volatile organic compounds (VOCs). Embodiments of the invention are directed to methods and apparatus for near-real-time in-situ detection and accumulated dose measurement of exposure to naphthalene vapor and other hazardous gaseous VOCs. The methods and apparatus employ excitation of fluorophors native or endogenous to compounds of interest using light sources emitting in the ultraviolet below 300 nm and measurement of native fluorescence emissions in distinct wavebands above the excitation wavelength. The apparatus of some embodiments are cell-phone-sized sensor/dosimeter "badges" to be worn by personnel potentially exposed to naphthalene or other hazardous VOCs. The badge sensor of some embodiments provides both real time detection and data logging of exposure to naphthalene or other VOCs of interest from which both instantaneous and accumulated dose can be determined. The badges employ a new native fluorescence based detection method to identify and differentiate VOCs. The particular focus of some embodiments are the detection and identification of naphthalene while other embodiments are directed to detection and identification of other VOCs like aromatic hydrocarbons such as benzene, toluene, and xylene.

Hug, William F.↗

Spinoff from Space Astronomy

American Science and Engineering (AS&E) built NASA's first x-ray telescope, flown on OSO-4 (Orbiting Solar Observatory), and developed the x-ray detectors that operated flawlessly for four years aboard SAS-1 (Small Astronomy Satellite). The experience AS&E acquired in detecting and processing cosmic x-rays gave the company a broad technology base for commercial applications. Among the commercial products that stemmed from AS&E's space technology are: Micro Dose x-ray scanner for medical use; a digital radiography diagnosis, a system for nondestructive testing of manufactured products; a system of load management for electric utilities; and additional specialized instruments.

Source record↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

Characterization of the Radiation Shielding Properties of U.S. and Russian Extravehicular Activity Suits

Reported herein are results from the Eril Research, Inc. (ERI) participation in the JSC-sponsored study characterizing the radiation shielding properties of the two types of space suit that astronauts are wearing during the EVA on-orbit assembly of ISS. Measurements using passive detectors were carried out to assess the shielding properties of the U.S. EMU Suit and the Russian Orlan-M suit during irradiations of the suits and a tissue-equivalent phantom to monoenergetic proton and electron beams at LLUMC. During irradiations of 6 MeV electrons and 60 MeV protons, absorbed dose as a function of depth was measured using TLDs exposed behind swatches of the two suit materials and inside the two EVA helmets. Considerable reduction in electron dose was measured behind all suit materials in exposures to 6 MeV electrons. Slowing of the proton beam in the suit materials led to an increase in dose measured in exposures to 60 MeV protons. During 232 MeV proton irradiations, measurements were made with TLDs and CR-39 PNTDs at five organ locations inside a tissue-equivalent phantom, exposed both with and without the two EVA suits. The EVA helmets produce a 13% to 27% reduction in total dose and a 0% to 25% reduction in dose equivalent when compared to measurements made in the phantom head alone. Differences in dose and dose equivalent between the suit and non-suit irradiations for the lower portions of the two EVA suits tended to be smaller. Proton-induced target fragmentation was found to be a significant source of increased dose equivalent, especially within the two EVA helmets, and average quality factor inside the EMU and Orlan-M helmets was 2% to 14% greater than that measured in the bare phantom head.

Benton, E. R.↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved field-portable system to measure Cs-137 in wildlife

Here, we have developed an improved system to measure Cs-137 in wildlife at the Savannah River Site. This field-portable system consists of a shielded 5 cm by 10 cm by 40 cm NaI detector controlled by an Ametek Ortec Digibase. Measurement of an animal’s radioactivity is made by placing the animal at a predefined location on the detector system for a one minute count-time. The counts, animal type, and animal weight are then used as inputs to an algorithm which calculates the amount of Cs-137 within the whole animal and within the edible meat portion of the animal. The results from these calculations are used to estimate the received dose from eating this animal and is included in the Savannah River Site’s Hunter Dose Tracking System. This system has a detection limit of 0.60 pCi/g (22.20 Bq/kg) with a typical measurement uncertainty of less than 0.32 pCi/g (11.84 Bq/kg).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

High LET, passive space radiation dosimetry and spectrometry

The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

Benton, E. V.↗

Spacecraft Solar Particle Event (SPE) Shielding: Shielding Effectiveness as a Function of SPE model as Determined with the FLUKA Radiation Transport Code

Analysis of both satellite and surface neutron monitor data demonstrate that the widely utilized Exponential model of solar particle event (SPE) proton kinetic energy spectra can seriously underestimate SPE proton flux, especially at the highest kinetic energies. The more recently developed Band model produces better agreement with neutron monitor data ground level events (GLEs) and is believed to be considerably more accurate at high kinetic energies. Here, we report the results of modeling and simulation studies in which the radiation transport code FLUKA (FLUktuierende KAskade) is used to determine the changes in total ionizing dose (TID) and single-event environments (SEE) behind aluminum, polyethylene, carbon, and titanium shielding masses when the assumed form (i. e., Band or Exponential) of the solar particle event (SPE) kinetic energy spectra is changed. FLUKA simulations have fully three dimensions with an isotropic particle flux incident on a concentric spherical shell shielding mass and detector structure. The effects are reported for both energetic primary protons penetrating the shield mass and secondary particle showers caused by energetic primary protons colliding with shielding mass nuclei. Our results, in agreement with previous studies, show that use of the Exponential form of the event

Koontz, Steve↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗