Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

TEDS Test Plan for Performance Characterization of Packed-bed Thermal Energy Storage Unit

This report proposes a set of test plans for performance measurement and characterization of the packed-bed thermal energy storage (TES) unit for TEDS. The main goals of this test plan are three-fold: (i) support the high-fidelity data measurement for TEDS, (ii) characterize thermal and structural performance of the TEDS TES unit, and (iii) produce high quality validation-oriented data. To achieve the goals, it is first suggested to revisit the instrument calibration and data sampling protocols applied during the startup and commissioning tests of TEDS, based on the observation from the recent CFD validation study using the TEDS TES operational data. The uncertainty quantification of the thermal and hydraulic measurements is also suggested. Lastly, test matrices are provided for charge, discharge, and standby modes of the packed-bed TES unit, respectively, to characterize the thermal and structural performances during the envisioned TEDS operations.

25 ENERGY STORAGE↗

Inaugural Symposium of the Institute for Sustainable Energy and Environment, Virginia Commonwealth University

The Inaugural Symposium of the Institute for Sustainable Energy and Environment (ISEE) was held in Virginia Commonwealth University, Richmond, Virginia during April 26 – 28, 2023. The symposium addressed issues and challenges in energy and environment and highlighted the use of clean renewable energy to mitigate the adverse effects of fossil fuels and the greenhouse gases it produces. These issues are complex as the involve educating the public that the climate change is real, it is caused by the use of fossil fuels, it requires scientists and engineers to understand the fundamental science in the production and storage of renewable energy, it requires industries to manufacture and distribute the equipment necessary for commercial application of these technologies, it requires policy makers to put together policies and guidelines to make the transition from fossil fuels to renewable energies efficient, and it requires social scientists and educators to address environmental justice issues and create a workforce to sustain the transition. The symposium considered all the above issues with a diverse list of speakers from the federal and state government, industrial partners, and experts from science and technology to social sciences and public policy. Speakers from the White House Office of Science and Technology Policy, Department of Energy, universities, and non-governmental agencies discussed the challenges and solutions in Plenary as well as Panel sessions. The talks were recorded with permission from the speakers and the panelists and were put in the ISEE website. The participants included students, postdoctoral fellows, and professors from Virginia Commonwealth University and local area Historically Black College and Universities (HBCU) such as Virginia State University and Norfolk State University. The $5000 fund awarded by the Department of Energy were used to support the participation of students, postdoctoral fellows, and faculty from the HBCU institutions. The technical program the list of participants is provided later in the document.

08 HYDROGEN↗

Impedance Methods for Analyzing Stability Impacts of Inverter-Based Resources: Stability Analysis Tools for Modern Power Systems

Power systems around the world are undergoing a major transformation because of the increasing shares of renewable energy, growing deployment of energy storage systems, proliferation of distributed energy resources, electrification of other sectors, and so on. In the United States, wind and solar provided almost 10% of electricity in 2019. The U.S. Energy Information Administration, in its 2020 Annual Energy Outlook, forecasted that the share of electricity from renewables will reach 38% by 2050, of which more than 80% will come from wind and solar. Wind and solar, along with battery energy storage systems, interface with the grid using power electronic inverters; hence, they are collectively referred to as inverter-based resources (IBRs). The increasing annual share of electricity from IBRs in a power system means that during more times of the year, the system will operate at a much higher concentration of IBRs. Figure 1 presents the hourly share of wind and solar generation in the Electric Reliability Council of Texas (ERCOT) system in Texas in 2019. While the annual wind share was at 20%, the instantaneous percentage share was much higher. Moments of high shares of IBRs (>50%) will continue to grow as more IBRs will be deployed in a power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal hybrid power plants for electric vehicle charging demand

Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.

14 SOLAR ENERGY↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

ThunderSecure: deploying real-time intrusion detection for 100G research networks by leveraging stream-based features and one-class classification network

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks (40/100G) across distributed sites for processing, storage, and analysis. Like general purpose networks, research networks experience intrusions. However, monitoring anomalies in such high-speed network traffics is challenging given current cyber-infrastructure. Moreover, traditional network intrusion detection systems (NIDS) are signature based. However, anomaly patterns are difficult to define and that rulesets are often not updated frequently enough to reflect the changes of attack behaviors. We present ThunderSecure, a high-throughput, unsupervised learning-based intrusions detection system for 100G research networks. ThunderSecure implements an efficient packet processing and detection pipeline using multi-cores and GPUs. It extracts statistical and temporal features from real-time network data streams and feeds them to a one-class anomaly detection network. A baseline of normal distribution will be created based on the training observation. Testing traffic deviated from the learned profile will be marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets mirrored from two 100G network connections at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. Results show that ThunderSecure can recognize science data traffic captured long after the training and made nearly certain detection on the segment of the streams where anomalous flows were injected.

100G research network↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

Emergency Generation Asset Positioning for Resilient Transmission Grid Operation: Preprint

In this paper we study a problem of hurricane emergency preparedness via placement of emergency generation assets prior to its strike. We present a two-stage stochastic model for choosing locations and quantities of emergency storage to help support the power grid through a hurricane event. The expectation of losses in our two-stage model is estimated using the sample average approximation. We construct damage scenarios for sample average approximation using WIND Toolkit meteorological data and fragility curves of various electric grid components. We demonstrate the efficacy of our two-stage planning model by simulating operations during Hurricane Dolly on the 2000-bus transmission test system. Our model, coupled with our scenario selection strategy, is effective at mitigating loss of load when compared to a model without emergency generation assets placed prior to an extreme event.

emergency preparedness↗

Impact of Quaternary Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Transactive Energy Rationing in an Islanded Electric Power System

A battery energy storage system (BESS) has been installed on Nantucket Island to provide service continuity during the N-1 contingency of partial electricity supply interruption from the mainland. During the N-2 contingency of complete interruption from the mainland, most of the loads will have to be disconnected so that a combustion gas turbine (CTG) can supply critical facilities. This work proposes an alternative transactive rationing mechanism that would provide some service to all of the loads, and still fully serve the critical loads, through market-based control during the N-2 contingency. A BESS operating strategy is proposed that would enhance the transactive rationing mechanism. The necessary enabling changes to communication systems, controls and utility tariffs are discussed, along with some ancillary benefits.

transactive energy, power distribution, energy sto↗

Surface Atomic Rearrangement with High Cation Ordering for Ultra-Stable Single-Crystal Ni-Rich Co-Less Cathode Materials

It is crucial to minimize cobalt content in Ni-rich layered single-crystal cathodes due to their high price and limited availability, yet it will inevitably lead to cation disordering, capacity degradation, and thermal issues. Herein, to overcome the intrinsic trade-off between performance and composition of Ni-rich Co-less single-crystal cathodes, a precursor engineering strategy with an epitaxially grown cobalt enrichment on the surface is innovatively proposed. In contrast to traditional coating modifications with random orientation and rigid surface-bulk boundary, the epitaxially enriched surface cobalt layer on the precursor undergoes rapid interdiffusion with the internal Ni 3+ during the optimized sintering process. This interdiffusion eliminates the surface-bulk boundary, promoting the uniform distribution of cobalt and synergistically addressing the Li/Ni intermixing. Moreover, an enhanced surface Li + diffusion is obtained, thereby suppressing the Li + concentration gradient and intragranular cracks generation. Consequently, the modified LiNi 0.7 Co 0.07 Mn 0.23 O 2 exhibits impressive cycling stability with increased capacity retention in both coin-type half-cells and pouch-type full-cells (91% after 1000 cycles), even under the harsh condition of high-temperature, surpassing the majority of previously reported Ni-rich cathodes. Finally, this work opens new avenues toward the low cost, high energy density, thermal stability, and long cyclic life for Ni-rich Co-less cathodes and sheds light on large-scale commercial production.

25 ENERGY STORAGE↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization Framework for Solar Energy Integrated Resilient Distribution Grid

The increasing penetration of distributed photovoltaic (PV) energy and other distributed energy resources (DERs) such as energy storage batteries, diesel generators, and mobile generators deployed in distribution grids must be properly controlled and coordinated to ensure reliable, resilient, and affordable grid operation in response to various operating conditions. Particularly, weather-induced power outages, such as natural disasters, are among the most common causes of power supply interruptions for distribution grid operations [E-1]. Distributed PV and DERs feature advanced grid supporting capabilities and can potentially enhance power supply continuity during and after extreme weather events. To leverage PV and other DERs to provide resilience benefits while ensuring operational and economic feasibility, distribution grids must be carefully designed, proactively managed, and safely operated through a comprehensive framework.

14 SOLAR ENERGY↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BI-LEVEL OPTIMIZATION FOR ELECTRICITY TRANSACTION IN SMART COMMUNITY WITH MODULAR PUMP HYDRO STORAGE

Grid integration of the increasing distributed energy resources could be challenging in terms of new infrastructure investment, power grid stability, etc. To resolve more renewables locally and reduce the need for extensive electricity transmission, a community energy transaction market is assumed with market operator as the leader whose responsibility is to generate local energy prices and clear the energy transaction payment among the prosumers (followers). The leader and multi-followers have competitive objectives of revenue maximization and operational cost minimization. This non-cooperative leader-follower (Stackelberg) game is formulated using a bi-level optimization framework, where a novel modular pump hydro storage technology (GLIDES system) is set as an upper level market operator, and the lower level prosumers are nearby commercial buildings. The best responses of the lower level model could be derived by necessary optimality conditions, and thus the bi-level model could be transformed into single level optimization model via replacing the lower level model by its Karush-Kuhn-Tucker (KKT) necessary conditions. Several experiments have been designed to compare the local energy transaction behavior and profit distribution with the different demand response levels and different local price structures. The experimental results indicate that the lower level prosumers could benefit the most when local buying and selling prices are equal, while maximum revenue potential for the upper level agent could be reached with non-equal trading prices.

Chen, Yang↗