Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Assessing the Interactive Impacts of Energy Efficiency and Demand Response on Power System Costs and Emissions

Utilities are increasingly interested in integrating energy efficiency (EE) and demand response (DR) measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and resulting utility system impacts are not well understood. We quantify the impacts of EE and DR in isolation and in combination on bulk power system costs and emissions based on changes in generation expansion, transmission expansion, and dispatch patterns. The study methodology mimics utility resource planning and uses more novel techniques to select least-cost generation and transmission capacity from supply-and demand-side resources, as compared to more commonly used utility approaches that only consider supply-side resources. The results identify key EE and DR characteristics affecting each other’s power system value and the most valuable technologies and strategies that can be jointly deployed. We discuss implications for EE and DR cost-effectiveness frameworks, program design, and integrated resource planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response Operation of Electricity-Intensive Chemical Processes for Reduced Greenhouse Gas Emissions: Application to an Air Separation Unit

A recent push for reduced greenhouse gas (GHG) emissions has led (in part) to the addition of renewable electricity generation sources to the power generation mix. Renewables such as wind and solar are desynchronized from grid demand, requiring the use of fossil fuels to bridge the gap. We propose a novel production scheduling formulation, emissions-minimizing production (EMP), which utilizes time-based information on the nature of the power generation mix to lower GHG emissions related to the transmission and generation of electricity for industrial users. We demonstrate the application of EMP on a single-column air separation unit. The scheduling problem is cast as a mixed integer linear program that can be solved in a practical amount of time. Extensive numerical studies are used to place EMP in the context of other production scheduling methods (such as demand response), and demonstrate its potential for significant reductions in GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control of Distributed Energy Resources and Demand Response under Uncertainty

We take the perspective of a microgrid that has installed distribution energy resources (DER) in the form of distributed generation with combined heat and power applications. Given uncertain electricity and fuel prices, the microgrid minimizes its expected annual energy bill for various capacity sizes. In almost all cases, there is an economic and environmental advantage to using DER in conjunction with demand response (DR): the expected annualized energy bill is reduced by 9percent while CO2 emissions decline by 25percent. Furthermore, the microgrid's risk is diminished as DER may be deployed depending on prevailing market conditions and local demand. In order to test a policy measure that would place a weight on CO2 emissions, we use a multi-criteria objective function that minimizes a weighted average of expected costs and emissions. We find that greater emphasis on CO2 emissions has a beneficial environmental impact only if DR is available and enough reserve generation capacity exists. Finally, greater uncertainty results in higher expected costs and risk exposure, the effects of which may be mitigated by selecting a larger capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demo Abstract: Toward Data-driven Demand-Response Optimization in a Campus Microgrid

We describe and demonstrate a prototype software architecture to support data-driven demand response optimization (DR) in the USC campus microgrid, as part of the Los Angeles Smart Grid Demonstration Project. The architecture includes a semantic information repository that integrates diverse data sources to support DR, demand forecasting using scalable machine-learned models, and detection of load curtailment opportunities by matching complex event patterns.

Amam, Saima↗

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

H 2 -optimal transactive control of electric power regulation from fast-acting demand response in the presence of high renewables

Here, this paper presents an H 2 -optimal power regulation scheme for balancing authorities to provide regulation services using both generation and load resources in the presence of a significant amount of intermittent renewable generation. The optimal controller is designed to minimize the loss of total economic surplus due to deviations from the schedule because of generation contingencies. The results show that the optimal controller outperforms the conventional ACE control policy by (1) providing faster return to the schedule under varying demand response levels, (2) reducing the cost of using reserve units for regulation services, and (3) minimizing deviations from the global surplus-maximizing schedule.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat Pump Water Heaters: Controlled Field Research of Impact on Space Conditioning and Demand Response Characteristics

A new generation of heat pump water heaters (HPWH) has been introduced into the U.S. market that promises to provide significant energy savings for water heating. Many electric utilities are promoting their widespread adoption as a key technology for meeting energy conservation goals and reducing greenhouse gas emissions. There is, however, considerable uncertainty regarding the space conditioning impact of an HPWH installed in a conditioned space. There is also uncertainty regarding the potential for deployment of HPWHs in demand response (DR) programs to help manage and balance peak utility loads in a similar manner as conventional electric resistance water heaters (ERWH). To help answer these uncertainties, controlled experiments have been undertaken over 30 months in a matched pair of unoccupied Lab Homes located on the campus of the Pacific Northwest National Laboratory (PNNL) in Richland, Washington.

demand response↗

Learning-Based Demand Response in Grid Interactive Buildings via Gaussian Processes

This paper presents a predictive controller for a grid-interactive multi-zone building where the temperature dynamics are learned via Gaussian Process (GP) regression. We investigate the development of a learning-based predictive control with two main objectives: (i) continuously learn the temperature dynamics of the building based on data; and, (ii) use the learned dynamics to solve a multi-objective predictive control problem to guarantee occupants' comfort and energy efficiency during normal conditions and demand response events. We leverage the probabilistic non-parametric properties of GPs to estimate the (unknown) non-linear temperature dynamics of the building and to incorporate the uncertainty of those predictions in a multi-objective optimization problem. The GP-based predictive control is solved via a zero-order primal-dual projected-gradient algorithm. We evaluate numerically the performance of the proposed controller using a five-zone commercial building.

demand response↗

Generic modelling and optimal day-ahead dispatch of micro-energy system considering the price-based integrated demand response

As an extension of micro-grid, micro-energy system (MES) is one of the important carriers for energy utilization in the future, and using energy prices as a controllable resource is conducive to improving the optimization potential of MES. Firstly, based on the energy hub model, a generic method for modelling the steady-state energy balance equation of MES is proposed. Then, considering the multi-energy substitution effect in the background of multi-energy coupling, the concept of price-based integrated demand response (P-IDR) is introduced. Meanwhile, based on the price elasticity theory and the discrete choice theory, the energy timing transfer characteristics and energy substitution characteristics in P-IDR is modelled. Furthermore, after taking into account the P-IDR, an MINLP model for day-ahead dispatch of MES is built, and a generalized benders decomposition method is used for solution. Case studies are conducted on an MES to verify the effectiveness of the proposed modelling method. Here, the result shows that it is beneficial to improve renewable energy accommodation and reduce the peak and off-peak difference of energy load when the P-IDR is deployed. In addition, consider the energy substitution characteristics can reduce the user’s cost on energy purchase and be more in line with the user’s rational consumption behaviour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Custom Controls for Improved Demand Response from Heat Pump Water Heaters

As part of a Grid Modernization Laboratory Consortium (GMLC) project looking at defining grid services for a range of devices, NREL used a custom controller to investigate the ability of a HPWH to provide load add and load shed in hybrid and electric resistance mode using standard set point control. Based on those results, changes were made to the controls to increase the amount of grid services delivered, especially in the load-add case, and speed up the recovery from those events. The custom controls also include less common methods, such as duty cycling of the heat pump or elements. The improved controls led to an increase the amount of demand response that could be provided and enabled faster recovery. Results from the laboratory experiments will be presented, along with details about the custom controls that were implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating the demand response potential of ammonia plants

Demand-side management/demand response (DSM/DR) are key strategies for mitigating the inherent variability in electricity generation rates by renewable sources. This article represents—to our knowledge—the first foray into assessing the DR potential of ammonia plants. Ammonia plants are interesting candidates for DR initiatives because of their significant electricity use (for operating compressors driving the synthesis loop) and the ability to store the ammonia product relatively easily and safely. Our approach is based on formulating and solving an optimal DR scheduling problem for an ammonia plant while accounting for the process dynamics. To this end, we introduce a new Hammerstein–Wiener-inspired modeling framework based on injecting linear dynamics in a first-principles static nonlinear model of the process. The results are encouraging; for the cases considered, peak-time power consumption decreases between 3.57% and 7.40%, coupled with 1.39% to 3.70% reductions in operating cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hawaiian Electric Company Demand Response Roadmap Project

The objective of this project was to develop a “roadmap” to guide the Hawaiian Electric Company (HECO) demand response (DR) planning and implementation in support of the Hawaii Clean Energy Initiative (HCEI) 70% clean energy goal by 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The use of price-based demand response as a resource in electricity system planning

Utilities have conducted IRP for decades to consider both supply- and demand-side resources to meet bulk power system needs. More recently, an increasing number of states are requiring regulated utilities to file plans that identify distribution system needs, including DERs that can avoid or defer certain types of traditional utility investments cost-effectively. Price-based demand response (DR) is an underutilized resource that could substantially contribute to load flexibility. We find that evaluation of price-based DR as a solution to meet identified electricity system needs is uncommon at both planning processes. Where price-based DR is considered as a solution, methodologies are often deficient in the characterization and treatment of this resource. Based on our analysis of utility filings and state requirements, this brief provides recommendations for improving consideration of price-based DR in the context of long-term planning for bulk power and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time Pricing Demand Response in Operations

Abstract—Dynamic pricing schemes have been implemented in commercial and industrial application settings, and recently they are getting attention for application to residential customers. Time-of-use and critical-peak-pricing rates are in place in various regions and are being piloted in many more. These programs are proving themselves useful for balancing energy during peak periods; however, real-time (5 minute) pricing signals combined with automation in end-use systems have the potential to deliver even more benefits to operators and consumers. Besides system peak shaving, a real-time pricing system can contribute demand response based on the locational marginal price of electricity, reduce load in response to a generator outage, and respond to local distribution system capacity limiting situations. The US Department of Energy (DOE) is teaming with a mid-west electricity service provider to run a distribution feeder-based retail electricity market that negotiates with residential automation equipment and clears every 5 minutes, thus providing a signal for lowering or raising electric consumption based on operational objectives of economic efficiency and reliability. This paper outlines the capability of the real-time pricing system and the operational scenarios being tested as the system is rolled-out starting in the first half of 2012.

Demand Response↗

Characterization of demand response in the commercial, industrial, and residential sectors in the United States

The goal of our study is to provide an overview of demand response (DR) technologies, including standards and end uses, in the United States and describe resource characteristics and the attributes of 14 specific DR resources in the U.S. commercial, residential, and industrial sectors. The attributes reviewed for the end uses being considered are response frequency, response time, the need for and impacts of energy pre- or recharge, the cost of enabling a resource to respond to a load-curtailment signal, and the magnitude of load curtailment in a given resource. We also describe controls and communications technologies that can enable end uses to participate in DR programs. The characterization was initially developed as a foundational work to quantify hourly availability of DR resources from the selected end uses followed by a multi-laboratory effort that quantified DR's value within the Western Interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗