Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-E-J-218: Novel Validation Paradigm of MRI to CT Deformation of Prostate

Purpose: Deformable registration algorithms are inherently difficult to characterize in the multi-modality setting due to a significant differences in the characteristics of the different modalities (CT and MRI) as well as tissue deformations. We present a unique paradigm where this is overcome by utilizing a planning-MRI acquired within an hour of the planning-CT serving as a surrogate for quantifying MRI to CT deformation by eliminating the issues of multi-modality comparisons. Methods: For nine subjects, T2 fast-spin-echo images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day as the planning-CT (planning-MRI). Significant effort in patient positioning and bowel/bladder preparation was undertaken to minimize distortion of the prostate in all datasets. The diagnostic-MRI was rigidly and deformably aligned to the planning-CT utilizing a commercially available deformable registration algorithm synthesized from local registrations. Additionally, the quality of rigid alignment was ranked by an imaging physicist. The distances between corresponding anatomical landmarks on rigid and deformed registrations (diagnostic-MR to planning-CT) were evaluated. Results: It was discovered that in cases where the rigid registration was of acceptable quality the deformable registration didn’t improve the alignment, this was true of all metrics employed. If the analysis is separated into cases where the rigid alignment was ranked as unacceptable the deformable registration significantly improved the alignment, 4.62mm residual error in landmarks as compared to 5.72mm residual error in rigid alignments with a p-value of 0.0008. Conclusion: This paradigm provides an ideal testing ground for MR to CT deformable registration algorithms by allowing for inter-modality comparisons of multi-modality registrations. Consistent positioning, bowel and bladder preparation may Result in higher quality rigid registrations than typically achieved which limits the impact of deformable registrations. In this study cases where significant differences exist, deformable registrations provide significant value.

60 APPLIED LIFE SCIENCES↗

SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However, improved methods need to be investigated to improve deformable results for rectum contours.

60 APPLIED LIFE SCIENCES↗

Contribution of vertebral deformities to chronic back pain and disability. The Study of Osteoporotic Fractures Research Group

Among 2992 white women aged 65-70 years recruited from population-based listings, we measured radiographic vertebral dimensions of T5-L4 and calculated ratios of heights: anterior/posterior, mid/posterior, and posterior/posterior of either adjacent vertebra. The degree of deformity for each vertebra was analyzed in terms of the number of standard deviations (SD) that ratio differed from the mean ratio calculated for the same vertebral level in this population. We correlated the severity of each woman's worst vertebral deformity with back pain, back disability in six activities of daily living, and height loss since age 25. Only 39.4% of the cohort had no vertebral deformity; 10.2% had a deformity greater than or equal to 4 SD. Vertebral deformities less than 4 SD below the mean were not associated with increased back pain, disability, or loss of height. In contrast, women whose deformity was greater than or equal to 4 SD had a 1.9 (95% CI, 1.5-2.4) times higher risk of moderate to severe back pain and a 2.6 (95% CI, 1.7-3.9) times higher risk of disability involving the back; they were also 2.5 (95% CI, 2.0-3.2) times more likely to have lost greater than or equal to 4 cm in height. All three types of vertebral deformity (wedge, end plate, and crush) were equally associated with these outcomes. Multiple deformities less than 4 SD did not increase the likelihood of these three outcomes, but multiple deformities greater than or equal to 4 SD tended to be associated with increased back pain, disability, and height loss. This large cross-sectional study suggests that vertebral deformities cause substantial pain, disability, or loss of height only if vertebral height ratios fall 4 SD below the normal mean. Much back pain could not be attributed to vertebral deformities, suggesting other causes.

Non-NASA Center↗

A single crystal plasticity finite element formulation with embedded deformation twins

Deformation twinning is an important plastic deformation mechanism in some polycrystalline metals such as titanium and magnesium. In this paper, we present a novel crystal plasticity finite element framework that accounts for deformation twinning explicitly, in addition to crystallographic slip. Within this computational framework, deformation twins are treated as weak discontinuities embedded within individual finite elements, such that a jump in the velocity gradient field is introduced (via the discretized gradient operator) between the twinned and untwinned crystalline regions, taking into account compatibility and traction continuity conditions at the interface between these two regions. The deformation gradient is multiplicatively split into elastic and plastic parts in the untwinned region, as is customary in finite-deformation crystal plasticity formulations. A different multiplicative decomposition of the deformation gradient into elastic, plastic (slip), and twinning parts is adopted in the twinned region, allowing deformation twinning to be accounted for as an additional mode of plastic deformation. Here, a stochastic model is used to predict twin nucleation at grain boundaries, and the evolution of the length and thickness of the twinned region under subsequent deformation is taken into account.

36 MATERIALS SCIENCE↗

SU-E-J-89: Comparative Analysis of MIM and Velocity’s Image Deformation Algorithm Using Simulated KV-CBCT Images for Quality Assurance

Purpose: Deformable image registration (DIR) is used routinely in the clinic without a formalized quality assurance (QA) process. Using simulated deformations to digitally deform images in a known way and comparing to DIR algorithm predictions is a powerful technique for DIR QA. This technique must also simulate realistic image noise and artifacts, especially between modalities. This study developed an algorithm to create simulated daily kV cone-beam computed-tomography (CBCT) images from CT images for DIR QA between these modalities. Methods: A Catphan and physical head-and-neck phantom, with known deformations, were used. CT and kV-CBCT images of the Catphan were utilized to characterize the changes in Hounsfield units, noise, and image cupping that occur between these imaging modalities. The algorithm then imprinted these changes onto a CT image of the deformed head-and-neck phantom, thereby creating a simulated-CBCT image. CT and kV-CBCT images of the undeformed and deformed head-and-neck phantom were also acquired. The Velocity and MIM DIR algorithms were applied between the undeformed CT image and each of the deformed CT, CBCT, and simulated-CBCT images to obtain predicted deformations. The error between the known and predicted deformations was used as a metric to evaluate the quality of the simulated-CBCT image. Ideally, the simulated-CBCT image registration would produce the same accuracy as the deformed CBCT image registration. Results: For Velocity, the mean error was 1.4 mm for the CT-CT registration, 1.7 mm for the CT-CBCT registration, and 1.4 mm for the CT-simulated-CBCT registration. These same numbers were 1.5, 4.5, and 5.9 mm, respectively, for MIM. Conclusion: All cases produced similar accuracy for Velocity. MIM produced similar values of accuracy for CT-CT registration, but was not as accurate for CT-CBCT registrations. The MIM simulated-CBCT registration followed this same trend, but overestimated MIM DIR errors relative to the CT-CBCT registration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-101: Improved CT to CBCT Deformable Registration Accuracy by Incorporating Multiple CBCTs

Purpose: Combining prior day CBCT contours with STAPLE was previously shown to improve automated prostate contouring. These accurate STAPLE contours are now used to guide the planning CT to pre-treatment CBCT deformable registration. Methods: Six IGRT prostate patients with daily kilovoltage CBCT had their original planning CT and 9 CBCTs contoured by the same physician. These physician contours for the planning CT and each prior CBCT are deformed to match the current CBCT anatomy, producing multiple contour sets. These sets are then combined using STAPLE into one optimal set (e.g. for day 3 CBCT, combine contours produced using the plan plus day 1 and 2 CBCTs). STAPLE computes a probabilistic estimate of the true contour from this collection of contours by maximizing sensitivity and specificity. The deformation field from planning CT to CBCT registration is then refined by matching its deformed contours to the STAPLE contours. ADMIRE (Elekta Inc.) was used for this. The refinement does not force perfect agreement of the contours, typically Dice’s Coefficient (DC) of > 0.9 is obtained, and the image difference metric remains in the optimization of the deformable registration. Results: The average DC between physician delineated CBCT contours and deformed planning CT contours for the bladder, rectum and prostate was 0.80, 0.79 and 0.75, respectively. The accuracy significantly improved to 0.89, 0.84 and 0.84 (P<0.001 for all) when using the refined deformation field. The average time to run STAPLE with five scans and refine the planning CT deformation was 66 seconds on a Telsa K20c GPU. Conclusion: Accurate contours generated from multiple CBCTs provided guidance for CT to CBCT deformable registration, significantly improving registration accuracy as measured by contour DC. A more accurate deformation field is now available for transferring dose or electron density to the CBCT for adaptive planning. Research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Examination of the distribution of the tensile deformation systems in tension and tension-creep of Ti-6Al-4V (wt.%) at 296 K and 728 K

The deformation behaviour of an α + β Ti–6Al–4V (wt.%) alloy was investigated during in situ deformation inside a scanning electron microscopy (SEM). Tensile experiments were performed at 296 and 728 K (~0.4Tm), while a tensile-creep experiment was performed at 728 K and 310 MPa (σ/σ ys = 0.74). The active deformation systems were identified using electron backscattered diffraction-based slip-trace analysis and SEM images of the specimen surface. The distribution of the active deformation systems varied as a function of temperature. Basal slip deformation played a major role in the tensile deformation behaviour, and the relative activity of basal slip increased with increasing temperature. For the 296 K tension deformation, basal slip was less active than prismatic slip, whereas this was reversed at 728 K. Twinning was observed in both the 296 and 728 K tension experiments; however, no more than 4% of the total deformation systems observed was twins. The tension-creep experiment revealed no slip traces, however grain boundary ledge formation was observed, suggesting that grain boundary sliding was an active deformation mechanism. The results of this work were compared with those from previous studies on commercially pure Ti, Ti–5Al–2.5Sn (wt.%) and Ti–8Al–1Mo–1V (wt.%), and the effects of alloying on the deformation behaviour are discussed. Here, the relative amount of basal slip activity increased with increasing Al content.

36 MATERIALS SCIENCE↗

A High-Speed Rotational Diamond Anvil Cell for In Situ Analysis of Hierarchical Microstructural Evolution of Metallic Alloys during Extreme Shear Deformation

High speed shear deformation is ubiquitous in engineering applications, ranging from material processing methods such as friction stir processing/extrusion and in tribological contacts. However, analyzing the microstructural evolution of materials while they are undergoing high speed shear deformation have been a long-standing challenge. This led to predominant reliance on ex situ microscopy before and after shear deformation. But ex situ microscopy lacks the ability to analyze dynamic and transient hierarchical microstructural evolution mechanisms that could occur during shear deformation of materials. Therefore, to better understand the dynamic mechanisms of mass and energy transfer in materials under shear deformation, we developed a first of its kind high-speed rotational diamond anvil cell (HS-RDAC) for synchrotron-based in situ high-energy x-ray diffraction (XRD). We studied the time resolved lattice strain evolution, XRD peak broadening and changes in spatial variation of shear deformation induced alloying in pure metal and metal alloy sheets and powder mixture using the HS-RDAC. These in situ results were combined with detailed ex situ microstructural characterization before and after the shear deformation using transmission electron microscopy and atom probe tomography, which revealed the different stages of evolution of a shear deformation induced hierarchical nanostructure. Multiscale computational simulations including computational fluid dynamics, crystal plasticity, molecular dynamic simulation and density functional theory uncovered the mechanisms behind morphological changes, evolution of defect structures and changes in driving force for shear deformation induced intermixing. In conclusion, this in situ HS-RDAC capability, in combination with ex situ microstructural characterization and computational simulations, can provide new insights into the hierarchical microstructural evolution pathway during shear deformation.

36 MATERIALS SCIENCE↗

Analytical continuation from bound to resonant states in the Dirac equation with quadrupole-deformed potentials

Here, resonances with pronounced single-particle characteristics are crucial for quantitative descriptions of exotic nuclei near and beyond the drip lines, and often impact halo formation and nucleon decay processes. Since the majority of nuclei are deformed, the interplay between deformation and orbital structure near threshold can lead to improved descriptions of exotic nuclei. Develop a method to study single-particle resonant orbital structure in the Dirac equation with a quadrupole-deformed Woods-Saxon potential. Determine the structure evolution of bound and resonant levels with deformation in this scheme, and examine the impact on halo formation in loosely bound systems, with a focus on the recent halo candidate nucleus 37 Mg. Analytical continuation of the coupling constant (ACCC) method is developed on the basis of the Dirac equation with a deformed Woods-Saxon potential. The scalar and vector terms in the deformed potential are determined by the energies of the valence neutron and nearby orbitals, which are extracted from a self-consistent relativistic Hartree-Bogoliubov (RHB) calculation with the PC-PK1 density functional. As a result, we compare the energies and widths of resonant orbitals in the recent halo nucleus candidate 37 Mg using the ACCC method based on the Dirac coupled-channel equations with those determined from the scattering phase shift (SPS) method. It is found that the results from the two methods agree well for narrow resonances, whereas the SPS method fails for broad resonances. Nilsson levels for bound and resonant orbitals from the ACCC method are calculated over a wide range of deformations and show some decisive hints of halo formation in 37 Mg. In conclusion, in our ACCC model for deformed potentials in the coupled-channel Dirac equations, the crossing of the configuration 1/2[321] and 5/2[312] orbitals at a deformation of approximately 0.5 enhances the probability to occupy the 1/2[321] orbital coming from 2 p3/2 thereby explaining the recent observation of a p-wave one-neutron halo configuration in 37 Mg. The resonant 1/2[301] configuration plays a crucial role in halo formation in the magnesium isotopes beyond A = 40 for a wide range of deformations larger than 0.2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The need for application-based adaptation of deformable image registration

Purpose: To utilize a deformable phantom to objectively evaluate the accuracy of 11 different deformable image registration (DIR) algorithms. Methods: The phantom represents an axial plane of the pelvic anatomy. Urethane plastic serves as the bony anatomy and urethane rubber with three levels of Hounsfield units (HU) is used to represent fat and organs, including the prostate. A plastic insert is placed into the phantom to simulate bladder filling. Nonradiopaque markers reside on the phantom surface. Optical camera images of these markers are used to measure the positions and determine the deformation from the bladder insert. Eleven different DIR algorithms are applied to the full and empty-bladder computed tomography images of the phantom (fixed and moving volumes, respectively) to calculate the deformation. The algorithms include those from MIM Software (MIM) and Velocity Medical Solutions (VEL) and nine different implementations from the deformable image registration and adaptive radiotherapy toolbox for Matlab. These algorithms warp one image to make it similar to another, but must utilize a method for regularization to avoid physically unrealistic deformation scenarios. The mean absolute difference (MAD) between the HUs at the marker locations on one image and the calculated location on the other serves as a metric to evaluate the balance between image similarity and regularization. To demonstrate the effect of regularization on registration accuracy, an additional beta version of MIM was created with a variable smoothness factor that controls the emphasis of the algorithm on regularization. The distance to agreement between the measured and calculated marker deformations is used to compare the overall spatial accuracy of the DIR algorithms. This overall spatial accuracy is also utilized to evaluate the phantom geometry and the ability of the phantom soft-tissue heterogeneity to represent patient data. To evaluate the ability of the DIR algorithms to accurately transfer anatomical contours, the rectum is delineated on both the fixed and moving images. A Dice similarity coefficient is then calculated between the contour on the fixed image and that transferred, via the calculated deformation, from the moving to the fixed image. Results: The phantom possesses sufficient soft-tissue heterogeneity to act as a proxy for patient data. Large discrepancies appear between the algorithms and the measured ground-truth deformation. VEL yields the smallest mean spatial error and a Dice coefficient of 0.90. MIM produces the lowest MAD value and the highest Dice coefficient of 0.96, but creates the largest spatial errors. Increasing the MIM smoothness factor above the default value improves the overall spatial accuracy, but the factor associated with the lowest mean error decreases the Dice coefficient to 0.85. Conclusions: Different applications of DIR require disparate balances between image similarity and regularization. A DIR algorithm that is optimized only for its ability to transfer anatomical contours will yield large deformation errors in homogeneous regions, which is problematic for dose mapping. For this reason, these algorithms must be tested for their overall spatial accuracy. The developed phantom is an objective tool for this purpose.

60 APPLIED LIFE SCIENCES↗

Innovative design of composite structures: Axisymmetric deformations of unsymmetrically laminated cylinders loaded in axial compression

The study focuses on the axisymmetric deformation response of unsymmetrically laminate cylinders loaded in axial compression by known loads. A geometrically nonlinear analysis is used. Though buckling is not studied, the deformations can be considered to be the prebuckling response. Attention is directed at three 16 layer laminates: a (90 sub 8/0 sub 8) sub T; a (0 sub 8/90 sub 8) sub T and a (0/90) sub 4s. The symmetric laminate is used as a basis for comparison, while the two unsymmetric laminates were chosen because they have equal but opposite bending-stretching effects. Particular attention is given to the influence of the thermally-induced preloading deformations that accompany the cool-down of any unsymmetric laminate from the consolidation temperature. Simple support and clamped boundary conditions are considered. It is concluded that: (1) The radial deformations of an unsymmetric laminate are significantly larger than the radial deformations of a symmetric laminate, although for both symmetric and unsymmetric laminates the large deformations are confined to a boundary layer near the ends of the cylinder; (2) For this nonlinear problem the length of the boundary layer is a function of the applied load; (3) The sign of the radial deformations near the supported end of the cylinder depends strongly on the sense (sign) of the laminate asymmetry; (4) For unsymmetric laminates, ignoring the thermally-induced preloading deformations that accompany cool-down results in load-induced deformations that are under predicted; and (5) The support conditions strongly influence the response but the influence of the sense of asymmetry and the influence of the thermally-induced preloading deformations are independent of the support conditions.

Hyer, M. W.↗

Study of the Micro-Nonuniformity of the Plastic Deformation of Steel

The plastic flow during deformation of real polycrystalline metals has specific characteristics which distinguish the plastic deformation of metals from the deformation of ordinary isotropic bodies. One of these characteristics is the marked micro-nonuniformity of the plastic deformation of metals. P.O. Pashkov demonstrated the presence of a considerable micro-nonuniformity of the plastic deformation of coarse-grained steel wit medium or low carbon content. Analogous results in the case of tension of coarse-grained aluminum were obtained by W. Boas, who paid particular attention to the role of the grain boundaries in plastic flow. The nonuniformit of the plastic deformation in microvolumes was also recorded by T.N. Gudkova and others, on the alloy KhN80T. N.F. Lashko pointed out the nonuniformity of the plastic deformation for a series of pure polycrystalline metals and one-phase alloys. In his later reports, P.O. Pashkov arrives at he conclusion that the nonuniformity of the distribution of the deformation along the individual grains has a significant effect on the strength and plastic characteristics of polycrystalline metals in the process of plastic flow. However, until now there has not existed any systematic investigation of the general rules of the microscopic nonuniformit of plastic deformation even though the real polycrystalline metals are extremely simple with regard to structure. In the present report, an attempt is made to study the micrononuniformity of the flow of polycrystalline metals by the method of statistical analysis of the variation of the frequency diagrams of the nonuniformity of the grains in the process of plastic deformation.

Chechulin, B. B.↗

Impact-Induced Chondrule Deformation and Aqueous Alteration of CM2 Murchison

Deformed chondrules in CM2 Murchison have been found to define a prominent foliation [1,2] and lineation [3] in 3D using X-ray computed tomography (XCT). It has been hypothesized that chondrules in foliated chondrites deform by "squeezing" into surrounding pore space [4,5], a process that also likely removes primary porosity [6]. However, shock stage classification based on olivine extinction in Murchison is consistently low (S1-S2) [4-5,7] implying that significant intracrystalline plastic deformation of olivine has not occurred. One objective of our study is therefore to determine the microstructural mechanisms and phases that are accommodating the impact stress and resulting in relative displacements within the chondrules. Another question regarding impact deformation in Murchison is whether it facilitated aqueous alteration as has been proposed for the CMs which generally show a positive correlation between degree of alteration and petrofabric strength [7,2]. As pointed out by [2], CM Murchison represents a unique counterpoint to this correlation: it has a strong petrofabric but a relatively low degree of aqueous alteration. However, Murchison may not represent an inconsistency to the proposed causal relationship between impact and alteration, if it can be established that the incipient aqueous alteration post-dated chondrule deformation. Methods: Two thin sections from Murchison sample USNM 5487 were cut approximately perpendicular to the foliation and parallel to lineation determined by XCT [1,3] and one section was additionally polished for EBSD. Using a combination of optical petrography, SEM, EDS, and EBSD several chondrules were characterized in detail to: determine phases, find microstructures indicative of strain, document the geometric relationships between grain-scale microstructures and the foliation and lineation direction, and look for textural relationships of alteration minerals (tochilinite and Mg-Fe serpentine) that indicate timing of their formation relative to deformation event(s). Preliminary Results: Deformed chondrules are dominated by forsterite and clinoenstatite with lesser amounts of Fe-Mg serpentine, sulfides, and low calcium pyroxene. Olivine grains are commonly fractured but generally show sharp optical extinction. The pyroxene, in contrast, is not only fractured but also often displays undulose extinction. In addition, the clinoenstatite is frequently twinned but it is unclear whether the twins are the result of mechanical deformation or inversion from protoenstatite [8]. EBSD work is currently ongoing to determine if areas of higher crystallographic strain can be imaged and mapped, and to determine the pyroxene twin orientations. In regards to alteration, we have found evidence for post-deformation formation of tochilinite and Mg-Fe serpentine indicating that aqueous alteration has indeed post-dated the deformation of the chondrules.

Hanna, R. D.↗

Structural and Magnetic Properties of Thermal- and Deformation-Induced Martensite in an Fe-27%Ni-4%Mn-1%Zn Alloy

Deformation- and thermal-induced martensite properties were examined according to existing martensite morphology and magnetic properties for same prior austenite homogenization conditions in Fe-27%Ni-4%Mn-1%Zn alloy. Scanning electron microscope (SEM) and vibrating sample magnetometer (VSM) characterization techniques were employed for the investigation. Scanning electron microscope observations showed that while martensite formation in the austenite phase of alloy exhibited a lath morphology by thermal effect, elongated deformation-induced martensite morphology exists after deformation. The Curie temperatures were detected at about 201 K for thermal-induced martensite and at about 226 K for deformation-induced martensite from VSM measurements. The magnetic saturation values were determined as about 21 emu g{sup −1} for thermal-induced martensite and 23 emu g{sup −1} for deformation-induced martensite. We found that magnetic saturation increased with deformation effect. On the other hand, VSM offered the soft ferromagnetic characteristic with coersive values of 36 Oe for thermal-induced martensite and the soft ferromagnetic characteristic with 47 Oe for deformation-induced martensite. The changes in the magnetic properties resulting from the thermal and deformation affect were clearly determined. Deformation caused magnetic stabilization in Fe-27%Ni-4%Mn-1%Zn alloy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of microstructure anisotropy on room and medium temperature ECAP deformed F138 steel

The microstructure developed during severe plastic deformation results in improved mechanical properties because of the decrease in domain sizes and accumulation of defects, mainly dislocation arrays. The characteristic deformation stages observed in low stacking fault energy (SFE) face centered cubic (FCC) materials are highly influenced by the development of the primary and secondary twinning that compete with dislocation glide. In this paper, a low SFE F138 stainless steel is deformed by equal channel angular pressing (ECAP) up to 4 passes at room temperature (RT) and at 300 °C to compare the grain refinement and twin boundary development with increasing deformation. Tensile tests were performed to determine the deformation stages reached by the material before and after ECAP deformation, and the resulting microstructure was observed by TEM. X-ray diffraction and EBSD, average technique the first and local the second one, were used to quantify the microstructural changes, allowing the determination of diffraction domain sizes, dislocation and stacking fault densities and misorientation indices, which lead to a complete analysis of the deformation introduced in the material, with comparative correlations between various microstructural parameters. - Highlights: • The microstructure of ECAP pressed F138 steel was studied using TEM, EBSD and XRD. • Increasing deformation reduced domain sizes and increased dislocation densities. • Dislocation array compactness and misorientation increased with higher deformation. • Largest dislocation densities, mostly screw, match with simultaneous activation of twins. • Several correlations among microstructural features and parameters have been disclosed.

36 MATERIALS SCIENCE↗

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for “dose of the day” calculations

Purpose: The aim of this study was to evaluate the appropriateness of using computed tomography (CT) to cone-beam CT (CBCT) deformable image registration (DIR) for the application of calculating the “dose of the day” received by a head and neck patient. Methods: NiftyReg is an open-source registration package implemented in our institution. The affine registration uses a Block Matching-based approach, while the deformable registration is a GPU implementation of the popular B-spline Free Form Deformation algorithm. Two independent tests were performed to assess the suitability of our registrations methodology for “dose of the day” calculations in a deformed CT. A geometric evaluation was performed to assess the ability of the DIR method to map identical structures between the CT and CBCT datasets. Features delineated in the planning CT were warped and compared with features manually drawn on the CBCT. The authors computed the dice similarity coefficient (DSC), distance transformation, and centre of mass distance between features. A dosimetric evaluation was performed to evaluate the clinical significance of the registrations errors in the application proposed and to identify the limitations of the approximations used. Dose calculations for the same intensity-modulated radiation therapy plan on the deformed CT and replan CT were compared. Dose distributions were compared in terms of dose differences (DD), gamma analysis, target coverage, and dose volume histograms (DVHs). Doses calculated in a rigidly aligned CT and directly in an extended CBCT were also evaluated. Results: A mean value of 0.850 in DSC was achieved in overlap between manually delineated and warped features, with the distance between surfaces being less than 2 mm on over 90% of the pixels. Deformable registration was clearly superior to rigid registration in mapping identical structures between the two datasets. The dose recalculated in the deformed CT is a good match to the dose calculated on a replan CT. The DD is smaller than 2% of the prescribed dose on 90% of the body's voxels and it passes a 2% and 2 mm gamma-test on over 95% of the voxels. Target coverage similarity was assessed in terms of the 95%-isodose volumes. A mean value of 0.962 was obtained for the DSC, while the distance between surfaces is less than 2 mm in 95.4% of the pixels. The method proposed provided adequate dose estimation, closer to the gold standard than the other two approaches. Differences in DVH curves were mainly due to differences in the OARs definition (manual vs warped) and not due to differences in dose estimation (dose calculated in replan CT vs dose calculated in deformed CT). Conclusions: Deforming a planning CT to match a daily CBCT provides the tools needed for the calculation of the “dose of the day” without the need to acquire a new CT. The initial clinical application of our method will be weekly offline calculations of the “dose of the day,” and use this information to inform adaptive radiotherapy (ART). The work here presented is a first step into a full implementation of a “dose-driven” online ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗