Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Assessment of Fleet Inventory for Naval Air Station Whidbey Island: Task 1

Task 1 includes a survey of the inventory of non-tactical fleet vehicles at Naval Air Station Whidbey Island (NASWI) to characterize the fleet. This information and characterization are used to select vehicles for monitoring that takes place during Task 2. This monitoring involves data logging of vehicle operation in order to identify the vehicle’s mission and travel requirements. Individual observations of these selected vehicles provide the basis for recommendations related to PEV adoption. It also identifies whether a battery electric vehicle or plug-in hybrid electric vehicle (collectively referred to as PEVs) can fulfill the mission requirements and provide observations related to placement of PEV charging infrastructure. This report provides the results of the assessments and observations of the current non-tactical fleet, fulfilling the Task 1 requirements.

33 ADVANCED PROPULSION SYSTEMS↗

B827 Chemical Synthhesis Project - Industrial Control System Integration - Statement of Work & Specification with Attachments 1-14

The Chemical Synthesis Pilot Process at the Lawrence Livermore National Laboratory (LLNL) Site 300 827 Complex will be used to synthesize small quantities of material to support research and development. The project will modernize and increase current capabilities for chemical synthesis at LLNL. The primary objective of this project is the conversion of a non-automated hands-on process to a remoteoperation process, while providing enhanced batch process step control, stored recipe-specific parameter sets, process variable visibility, monitoring, alarm and warning handling, and comprehensive batch record data logging. This Statement of Work and Specification provides the industrial-grade process control requirements for the chemical synthesis batching control system, hereafter referred to as the “Control System” to be delivered by the System Integrator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomy-Enabled Fuel Savings for Military Vehicles: Report on 2016 Aberdeen Test Center Testing

Fuel savings have never been the primary focus for autonomy-enabled military vehicles. However, studies have estimated that autonomy in passenger and commercial vehicles could improve fuel economy by as much as 22%-33% over various drive cycles. If even a fraction of this saving could be realized in military vehicles, significant cost savings could be realized each year through reduced fuel transport missions, reduced fuel purchases, less maintenance, fewer required personnel, and increased vehicle range. Researchers from the National Renewable Energy Laboratory installed advanced data logging equipment and instrumentation on two autonomy-enabled convoy vehicles configured with Lockheed Martin's Autonomous Mobility Applique System to determine system performance and improve on the overall vehicle control strategies of the vehicles. Initial test results from testing conducted at the U.S. Army Aberdeen Test Center at the Aberdeen Proving Grounds are included in this report. Lessons learned from in-use testing and performance results have been provided to the project partners for continued system refinement.

33 ADVANCED PROPULSION SYSTEMS↗

Hardening of DOE UQ Codes for Ultra-Deep Proactive Geosteering in Oilfield Service

The primary objective of this project was to harden the DOE uncertainty quantification (UQ) code to solve the inverse problem for the geosteering service in the oilfield drilling and exploration. The primary focus is to verify the feasibility of using QUESO to solve geosteering inverse problems through statistical inversion. QUESO is a software library developed by QUEST, a DOE's Scientific Discovery through Advanced Computing (SciDAC) institute. In the process of drilling a borehole, geosteering is the act of adjusting the well trajectory on the fly to reach the geological targets or to keep the wellbore within desired formation. Geosteering inversion is to infer underground formation structure using measurements such as azimuthal resistivity logging data. The geosteering process relies on the real-time reconstruction of the subsurface earth model, and a robust and efficient inversion algorithm is always necessary to satisfy the job requirement. The new generation of azimuthal resistivity geosteering tool is capable of detecting multiple formation boundaries 20-100 ft away, and the corresponding geosteering inversion problem can be very challenging as many parameters need to be inverted within such a large depth of investigation. The success of the project will support US energy security by helping to advance subsurface modeling and characterization technologies in oilfield applications. An effective subsurface inversion algorithm and the implementation as a software package will promote the usage of ultra-deep azimuthal resistivity measurements, which can help well placement in complicated underground environments, reduce costs and risks of drilling, and increase oil and gas production. It will help medium and small size independent service companies and tool manufactures to enter the more advanced and lucrative directional drilling area. In addition, by hardening the QUESO code and building a transparent interface for easy manipulation of the QUESO functions, we provide a user-friendly tool for a larger scientific and industry communities that rely heavily on modeling and simulation tools for forecasting, parameter studies, design, and decision making. These are all activities that can strongly benefit from meaningful representations of modeling uncertainty supported by our product.

58 GEOSCIENCES↗

Smart Particle Collector with Real Time Spectroscopic Analysis

A particle collector breadboard testing system (Racetrack), based on the ACE1.0 particle collector model, was designed and built to study the mechanisms for particle collection and detection. Several parameters were investigated, such as current and voltage of the filament, magnetic fields and supporting electronics. Advanced optical spectroscopic features with data logging capabilities were designed in this project. The advanced features were tested for future incorporation into a new breed of particle collectors. Several experiments conducted with the Racetrack provided a path for a new prototype particle collector “ESP-EV1”. Preliminary results suggest that the new particle collector is an order of magnitude more efficient in collecting material than currently used collector systems. This project also demonstrated the capability to extract nanoparticulates from a sample containing material from 100 nm to 10 micron-sized particulates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Study of Potential Utilization of Triassic Rift Basins for Long-Term Carbon Sequestration

Triassic rift basins of the eastern United States present a potential option for long–term carbon dioxide (CO 2 ) sequestration. Exposed and buried basins are located near large point CO 2 sources. Because of their similar origins, comparable fill successions indicate a level of reproducibility that can be conveyed between basins. The thick rock successions of the exposed Culpeper and Gettysburg basins served as proxies for understanding of the basin sequences. Their study allowed recognition of five mappable assemblages of rock types, herein termed lithofacies associations. These lithofacies associations were formed by alluvial fan, braided and meandering streams and marginal and distal lake depositional processes.Stratigraphic architecture of the lithofacies associations within exposed basins suggests a vertical succession that consists of an initial coarse-grained fluvial succession that is progressively replaced upward and basinward by finer grained lacustrine deposits. Along the faulted margins of the basins alluvial fans transitioning to fluvial delta deposits reflect lateral progradation and contemporaneous lateral components of the basin filling.To test the model devised in exposed basins, facies associations were developed for the buried Taylorsville Basin. This basin preserves over 8,000 feet of Triassic rocks that are concealed beneath more than 2,000 feet of Cretaceous and Tertiary Coastal Plain sediments. Composition and stratigraphic architecture of these rocks are similar to those observed in exposed basins. Infilling of the basin was the result of vertical aggradation and lateral progradation of coarse-grained to fine-grained facies. Based upon study of outcrops in the Culpeper and Gettysburg basins, groups of recurring lithologic facies were identified as the fundamental constructs of the basin’s sediment infilling. These groups of facies, termed lithofacies associations, represent an amalgamation of lithologic components from broadly similar depositional systems. These lithologic associations were then extrapolated into the exposed and buried portions of the Taylorsville basins. This effort determined that Triassic rift basins provide several avenues for potential study of geologic sequestration of carbon. The characteristic rift basin succession in the basins presents possible reservoir targets within the marginal fluvial deposits. Furthermore, intrusive and extrusive mafic bodies present a potential source of fracture porosity that could serve as CO 2 reservoirs. Porosity values from thin section analysis of exposed basin samples are higher in alluvial fan and braided fluvial lithofacies. Porosity is highest in samples that show less compaction, due to a lack of ductile lithic fragments and/or higher stratigraphic position. Log data from the Taylorsville Basin indicates that porosity and permeability values in basin marginal fluvial strata are elevated. Near the center of the basin, porosity and permeability values are greatly reduced, primarily owing to the fine-grained character of the lacustrine deposits. Some Triassic basins also contain thick intervals of concordant extrusive and intrusive mafic igneous rocks. These igneous bodies are potential CO 2 reservoirs for several reasons. Firstly, extrusive lava flows provide potential storage in the layers of primary porosity that occur in the vesicules formed at the top of lava flows. Secondly, both lava flows and subsurface igneous sills exhibit extensive fracture porosity produced by the rapid cooling of the flows and intrusions. Thirdly, these igneous rocks are mafic in composition, and studies have shown that iron- and magnesium-rich mafic rocks provide sequestration opportunities through carbonate remineralization. Lastly, extrusive and intrusive igneous rocks are invariably preserved within fine-grained lake deposits. These lacustrine sediments can serve as a fine-grained confining layer that encases the igneous rocks both above and below.

01 COAL, LIGNITE, AND PEAT↗

Methodology Paper for Lower and Upper Cretaceous Characterization (SECARB Phase III Work Product 1.4.a)

This document serves as the SECARB Phase III work product 1.4.a “Methodology Paper for Lower and Upper Cretaceous Characterization.” The product summarizes the Project Team’s plans for Phase III assessment of the Upper and Lower Cretaceous Saline Reservoirs CO 2 storage capacity. The Project Team will concentrate on potential geologic CO 2 storage reservoirs of the Lower and Upper Cretaceous formations in the Southeast Regional Carbon Sequestration Partnership (SECARB) along the eastern Gulf Coast region. This work will involve assembly of regional geologic cross sections to better define the stratigraphic framework for this high priority, regionally significant geological formation in the SECARB region. Best available well log data and all available core data will be incorporated into the regional analysis to assess reservoir properties and the geologic framework for storage reservoir characteristics. Regional structure maps and reservoir thickness maps will be compiled. Detailed structure maps will be created to assess the suitability of specific storage sites and to assess the potential impact of significant structural features on storage reservoir and confining unit integrity. Of importance will be incorporating the new information being developed from the Phase II and Phase III CO2 storage field projects that will be assessing this formation for storage of CO 2 . The primary deliverable will be input into the next update of the “Regional Atlas”.

54 ENVIRONMENTAL SCIENCES↗

Integrating Machine Learning into a Methodology for Early Detection of Wellbore Failure [Slides]

Approximately 93% of US total energy supply is dependent on wellbores in some form. The industry will drill more wells in next ten years than in the last 100 years (King, 2014). Global well population is around 1.8 million of which approximately 35% has some signs of leakage (i.e. sustained casing pressure). Around 5% of offshore oil and gas wells “fail” early, more with age and most with maturity. 8.9% of “shale gas” wells in the Marcellus play have experienced failure (120 out of 1,346 wells drilled in 2012) (Ingraffea et al., 2014). Current methods for identifying wells that are at highest priority for increased monitoring and/or at highest risk for failure consists of “hand” analysis of multi-arm caliper (MAC) well logging data and geomechanical models. Machine learning (ML) methods are of interest to explore feasibility for increasing analysis efficiency and/or enhanced detection of precursors to failure (e.g. deformations). MAC datasets used to train ML algorithms and preliminary tests were run for “predicting” casing collar locations and performed above 90% in classification and identifying of casing collar locations.

54 ENVIRONMENTAL SCIENCES↗

Integrating Machine Learning into a Methodology for Early Detection of Wellbore Failure [Slides]

Approximately 93% of US total energy supply is dependent on wellbores in some form. The industry will drill more wells in next ten years than in the last 100 years (King, 2014). Global well population is around 1.8 million of which approximately 35% has some signs of leakage (i.e. sustained casing pressure). Around 5% of offshore oil and gas wells “fail” early, more with age and most with maturity. 8.9% of “shale gas” wells in the Marcellus play have experienced failure (120 out of 1,346 wells drilled in 2012) (Ingraffea et al., 2014). Current methods for identifying wells that are at highest priority for increased monitoring and/or at highest risk for failure consists of “hand” analysis of multi-arm caliper (MAC) well logging data and geomechanical models. Machine learning (ML) methods are of interest to explore feasibility for increasing analysis efficiency and/or enhanced detection of precursors to failure (e.g. deformations). MAC datasets used to train ML algorithms and preliminary tests were run for “predicting” casing collar locations and performed above 90% in classification and identifying of casing collar locations.

54 ENVIRONMENTAL SCIENCES↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

A Predictive Model for Internal Magazine Temperatures

This report describes data and methodology used to predict temperatures inside magazines used to store explosive devices, based on outside temperatures from a local weather station and data logged by sensors inside a single magazine over a limited period. It follows on earlier work and predictive models. In conjunction with aging models, predicted temperatures can be used to estimate degradation in the performance of explosives over long periods of storage.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Completion Report for the Well ER-6-2 Site Corrective Action Unit 97: Yucca Flat - Climax Mine

Well ER-6-2 and its satellite hole, Well ER-6-2 No.1, were drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. Well ER-6-2 was drilled in two stages in 1993 and 1994; the satellite hole, Well ER-6-2 No.1 was drilled nearby in 1993 but was abandoned. The wells were drilled as part of a hydrogeologic investigation program for the Yucca Flat-Climax Mine Corrective Action Unit Number 97, in the northeastern portion of the Nevada Test Site. The wells are located in Yucca Flat, within Area 6 of the Nevada Test Site. The wells provided information regarding the radiological and hydrogeological environment in a potentially down-gradient position from tests conducted in northern and central Yucca Flat. Construction of Well ER-6-2 began with a 1.2-meter-diameter surface conductor hole, which was drilled and cased off to a depth of 30.8 meters below the surface. A 50.8-centimeter diameter surface hole was then rotary drilled to the depth of 578.5 meters and cased off to the depth of 530.4 meters. The hole diameter was then reduced to 27.0 centimeters, and the borehole was advanced to a temporary depth of 611.4 meters. The borehole was conventionally cored to a total depth of 1,045 meters with a diameter of 14.0 centimeters. Borehole sloughing required cementing and re-drilling of several zones. The open-hole completion accesses the lower carbonate aquifer, the CP thrust fault, and the upper clastic confining unit. A fluid level depth of 543.2 meters was most recently measured in the open borehole in September 2007. No radionuclides were encountered during drilling. The satellite hole Well ER-6-2 No.1 was drilled approximately 15.2 meters north of Well ER-6-2 on the same drill pad. This was planned to be used as an observation well during future hydrologic testing at Well ER-6-2; however, the satellite hole was abandoned at the depth of 399 meters due to stuck drill pipe, and was subsequently cemented to the surface. Detailed lithologic descriptions with stratigraphic assignments in this report are based on composite drill cuttings samples collected every 3 meters, cores taken between the depths of 619.3 and 1,042.4 meters, and geophysical log data. Stratigraphic assignments within the Paleozoic section are based on paleontological analyses. The well was collared in alluvium and at 30.8 meters penetrated Paleozoic carbonate rocks. These consisted of dolostone with minor shale and limestone of the Bonanza King Formation, and limestone with minor quartzite, sandstone, and dolostone assigned to the Guilmette Formation. The borehole reached total depth in a shale unit assigned to the Chainman Shale. The units below the Bonanza King Formation are overturned due to faulting and folding and, therefore, are stratigraphically upside-down.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REMOTE AREA RADIATION MONITORING (RARM) ALTERNATIVES ANALYSIS

The Remote Area Radiation Monitoring (RARM) system will be used to provide real-time radiation monitoring information to the operations personnel during tank retrieval and transfer operations. The primary focus of the system is to detect potential anomalous (waste leaks) or transient radiological conditions. This system will provide mobile, real-time radiological monitoring, data logging, and status at pre-selected strategic points along the waste transfer route during tank retrieval operations. The system will provide early detection and response capabilities for the Retrieval and Closure Operations organization and Radiological Control personnel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparing Oregon State University to Meet the Research Challenges of the Global Nuclear Energy Partnership Final Scientific/Technical Report

The OSU Radiation Center requested $100,000 under the Global Nuclear Energy Partnership University Readiness program to provide for graduate student support, reactor equipment upgrades, and irradiation support. A portion of the funds requested were used to support the graduate education of a graduate student for a period of one year. The remaining funds were utilized to enhance the irradiation facilities of the Oregon State TRIGA® Reactor as well as to offset the costs of irradiations for initial investigations where grant funding is not available. The focus of this effort was to create an environment that would enhance facilities and equipment at Oregon State University which emphasize GNEP related themes, specifically material science analytical capabilities for the next generation of nuclear reactors. These enhancements included development of a prompt gamma neutron activation analysis analytical capability, digital reactor data logging, electronic dosimetry for researchers, replacement of sample grapples, and irradiation/analytical services.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Sorbent-Based Process for High Temperature Trace Metal Removal

The objective of this project was to demonstrate the efficacy of a novel sorbent can effectively remove trace metal contaminants (Hg, As, Se and Cd) from actual coal-derived synthesis gas streams at high temperature (above the dew point of the gas). The performance of TDA's sorbent has been evaluated in several field demonstrations using synthesis gas generated by laboratory and pilot-scale coal gasifiers in a state-of-the-art test skid that houses the absorbent and all auxiliary equipment for monitoring and data logging of critical operating parameters. The test skid was originally designed to treat 10,000 SCFH gas at 250 psig and 350 C, however, because of the limited gas handling capabilities of the test sites, the capacity was downsized to 500 SCFH gas flow. As part of the test program, we carried out four demonstrations at two different sites using the synthesis gas generated by the gasification of various lignites and a bituminous coal. Two of these tests were conducted at the Power Systems Demonstration Facility (PSDF) in Wilsonville, Alabama; a Falkirk (North Dakota) lignite and a high sodium lignite (the PSDF operator Southern Company did not disclose the source of this lignite) were used as the feedstock. We also carried out two other demonstrations in collaboration with the University of North Dakota Energy Environmental Research Center (UNDEERC) using synthesis gas slipstreams generated by the gasification of Sufco (Utah) bituminous coal and Oak Hills (Texas) lignite. In the PSDF tests, we showed successful operation of the test system at the conditions of interest and showed the efficacy of sorbent in removing the mercury from synthesis gas. In Test Campaign No.1, TDA sorbent reduced Hg concentration of the synthesis gas to less than 5 {micro}g/m{sup 3} and achieved over 99% Hg removal efficiency for the entire test duration. Unfortunately, due to the relatively low concentration of the trace metals in the lignite feed and as a result of the intermittent operation of the PSDF gasifier (due to the difficulties in the handling of the low quality lignite), only a small fraction of the sorbent capacity was utilized (we measured a mercury capacity of 3.27 mg/kg, which is only a fraction of the 680 mg/kg Hg capacity measured for the same sorbent used at our bench-scale evaluations at TDA). Post reaction examination of the sorbent by chemical analysis also indicated some removal As and Se (we did not detect any significant amounts of Cd in the synthesis gas or over the sorbent). The tests at UNDEERC was more successful and showed clearly that the TDA sorbent can effectively remove Hg and other trace metals (As and Se) at high temperature. The on-line gas measurements carried out by TDA and UNDEERC separately showed that TDA sorbent can achieve greater than 95% Hg removal efficiency at 260 C ({approx}200g sorbent treated more than 15,000 SCF synthesis gas). Chemical analysis conducted following the tests also showed modest amounts of As and Se accumulation in the sorbent bed (the test durations were still short to show higher capacities to these contaminants). We also evaluated the stability of the sorbent and the fate of mercury (the most volatile and unstable of the trace metal compounds). The Synthetic Ground Water Leaching Procedure Test carried out by an independent environmental laboratory showed that the mercury will remain on the sorbent once the sorbent is disposed. Based on a preliminary engineering and cost analysis, TDA estimated the cost of mercury removal from coal-derived synthesis gas as $2,995/lb (this analysis assumes that this cost also includes the cost of removal of all other trace metal contaminants). The projected cost will result in a small increase (less than 1%) in the cost of energy.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗