Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

Radically Engineered Modular Air Separation System with Tailored Oxygen Sorbents

The commercial energy sector relies heavily on fossil fuel conversion, and in the process releases a significant amount of CO 2 . A promising technology to utilize fossil fuels with relatively affordable CO 2 capture is gasification. However, it requires a pure oxygen stream. The current state of the art method to produce oxygen is cryogenic air separation, which supercools air to a liquid, and then using distillation columns to separate the components. While this method has been thoroughly studied, it only has a 25% efficiency from a second law standpoint and therefore requires a significant amount of energy (and associated emissions) for oxygen production. This, then, lowers the incentive for carbon capture within a plant, so alternative methods need to be investigated. One potential method, chemical looping air separation (CLAS), is a promising method to replace state of the art oxygen generation technologies. CLAS utilizes a cyclic redox scheme with an oxygen sorbent to create pure oxygen streams. This approach typically utilizes a dual reactor scheme where the oxygen deficient sorbent enters the first reactor and is subjected to high oxygen partial pressures to re-oxidize the sorbent. Then the sorbent is sent to the reducing reactor, where it is subjected to low oxygen partial pressure (steam or vacuum) to releases oxygen. The overarching objective of this project was to discover the principles for rational design and optimization of oxygen sorbents and process design to ensure the process is a viable replacement for cryogenic air separation, especially in the context of modular gasification systems. This was done through development, characterization, testing, and analyses of (a) high temperature mixed composite oxides; (b) low temperature doped perovskite oxides (A1 x A2 1-x B1 y B2 1-y O 3 ); (c) scale up synthesis and testing of the optimized sorbent particles; (d) process design and analyses of the CLAS system in the context of modular gasification applications.

01 COAL, LIGNITE, AND PEAT↗

A large millikelvin platform at Fermilab for quantum computing applications

The need for larger mK cooling platforms is being driven by the desire to host ever growing numbers of cryogenic qubits in quantum computing platforms. As part of the Superconducting Quantum Materials and Systems Center at Fermilab funded through the Department of Energy under the National Quantum Initiative, we are developing a cryogenic platform capable of reaching millikelvin temperatures in an experimental volume of 2 meters diameter by approximately 1.5 meters in height. The platform is intended to host a three-dimensional qubit architecture based on superconducting radiofrequency accelerator cavity technologies. This paper describes the baseline design of the platform, along with the expected key performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

Cryogenic Optical and Spin Scanning Probe Station for High-throughput Characterization of Solid-state Quantum Defects

This final technical report provides an overview of the key milestones achieved by Advanced Research Systems (ARS), a DOE SBIR/STTR Grant Recipient. ARS’s main objective was to develop a prototype of the Closed Cycle Cryogenic Quantum Probe Station (Avalanche). Designed for near field spectroscopy (Tip Enhanced Photoluminescence, TEPL and Tip Enhanced Raman Spectroscopy TERS) and far field spectroscopy (micro-Raman, micro-PL) is in the final stage of completion. The critical components have been tested and the final System Test of the AFM is scheduled for August 2025.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Liquid Hydrogen Heavy-Duty Vehicle Safety Review and Refueling Facility Design

Liquid hydrogen (LH 2 ) used as a fuel onboard a heavy-duty vehicle can result in increased storage capacity and faster refueling relative to compressed gas. However, there are concerns about hydrogen losses from boil-off, potential safety issues, gaps in codes and standards for cryogenic hydrogen fuel, and technical challenges with LH 2 systems for widespread transportation applications. A failure modes and effects analysis (FMEA), a safety codes and standards review, and a design review of the onboard liquid hydrogen system for a heavy-duty vehicle identified some of these potential safety issues and gaps in the codes and standards. The FMEA identified some medium and low risk failure points of the conceptual design, and the design review identified how carefully pressure relief needs to be considered for LH 2 systems. In addition, a conceptual design for a LH 2 refueling station was developed. Rough capital costs for the refueling station design were $\$1 million$ and the layout occupied approximately 13,000 ft 2 . These results can be used to inform future designs and analyses for LH 2 heavy-duty vehicles.

08 HYDROGEN↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic growth of Pd(111) nanostructures on MoS 2

Quantum confinement effects can induce the formation of discrete nanostructures with well-defined preferred heights in thin metallic films. In most systems, such electronic growth modes are weak and limited to cryogenic conditions. Recently, however, we have discovered that metals grown upon van der Waals surfaces can exhibit electronic growth at, or even above, room temperature to spontaneously form well-defined and highly stable nanostructures. Here, we explore the initial stages of room temperature deposition of Pd onto MoS 2 . We found that, even for minimal thicknesses, Pd spontaneously formed discrete islands with three atomic layers. The islands maintained this preferred height for nominal coverages below three atomic layers. At higher coverages, the preferred height switched abruptly to six atomic layers. Unlike previous studies using Au or Ag, the islands did not increase laterally with coverage but rather increased in number with lateral size remaining about the same. The preferred heights in Pd/MoS 2 correlate to the Pd Fermi surface topography and are also consistent with thicknesses showing minima in the density of states at the Fermi level, which suggest that the electronic growth modes are the driving factors in these self-assembled Pd nanostructures. The Pd system shows a preference for island nucleation compared to Au and Ag which grow laterally with increasing coverage. Furthermore, this is likely related to differences in bonding at the interface as Pd is typically much more reactive than Ag or Au.

36 MATERIALS SCIENCE↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS

Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics.

Quinn, Adam [Fermilab] (ORCID:0009000605056371)↗