Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “criticality benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

BLEECAM™ (Benchmarking Life Cycle Environmental, Economic, and Social Metrics for Critical and Advanced Minerals and Materials) [SWR-25-125]

The National Laboratory of the Rockies' (NLR) Benchmarking Life Cycle Environmental, Economic, and Social Metrics for Critical and Advanced Minerals and Materials (BLEECAM™) is an open-source, integrated decision-support tool for evaluating the impacts, risks, and trade-offs across U.S. and global materials supply chains. Funded by the U.S. Department of Energy, BLEECAM supports supply chain and market analysis. The tool integrates multi-objective supply chain optimization, system dynamics, network design, lifecycle assessment, techno-economic modeling, and social impact assessment methods to evaluate how supply chains evolve over time, geography, and deployment scenarios. BLEECAM also supports analysis related to energy infrastructure, data centers and digital infrastructure, advanced manufacturing, and other sectors that depend on critical materials.

Khalifa, SherifA. [National Laboratory of the Rock↗

Improved Verification and Validation Testing and Tools including Nuclear Criticality Safety Applications with the MCNP6.3® Code [Abstract]

A new Python-based framework has been developed to enable a more consistent layout with automatable setup, execution, and documentation of all verification and validation (V&V) test suites previously established for use with the MCNP code. In this paper, the new general framework for the V&V test suites is discussed, including information on all of the current capabilities and plans for future capabilities. For nuclear criticality safety applications, the existing V&V benchmark problems within the criticality, extended criticality, and analytic k-effective test suites have been ported into this new framework. In addition, the status and updates to the Rossi-alpha and subcritical multiplicationtest suites will be discussed. Some V&V results exercising new MCNP6.3 capabilities will be demonstrated.

97 MATHEMATICS AND COMPUTING↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility (IER 575, CED-2 Report)

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to the HTR-PROTEUS HALEU Benchmark Using Modern Analysis Methodologies

The HTR-PROTEUS IRPhEP Handbook benchmarks represent some of the highest quality benchmarks available for systems with TRISO-HALEU fuel, graphite pebbles, graphite reflector, and high neutron leakage. Nevertheless, significant variability in computed eigenvalue results was encountered in HTR-PROTEUS configurations that are relevant for transportation configurations. The team will investigate the source of these variabilities in the original benchmark. In addition, the team will investigate the HTR-PROTEUS subcritical measurements, kinetics data, and potential criticality effects from the introduction of hydrogen in the system (water ingress). The project will generate a benchmark evaluation of additional HTR-PROTEUS measurements that can significantly increase the value of these criticality benchmarks in testing nuclear codes and data to support transportation validation needs for industry and the U.S. NRC.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity Studies, Gap Analysis, and Benchmark Experiment Optimization for Reactor Physics and Criticality Safety Applications

Many new reactor designs, such as advanced reactors and micro reactors, have materials that lack nuclear data validation. This is also true for many other applications in criticality safety and global security. Both differential and integral experiments are needed to validate cross-section data. Without this, a user cannot have confidence in the predicted results of a radiation-transport code. This work describes an approach called ARCHIMEDES (Application Relevant Critical/Subcritical HEU/Pu-based Integral Measurements for Enhancing Data and Evaluating Sensitivities) to design new criticality experiments that have similar k eff cross-section sensitivities to an application of interest. This process involves simulations to generate cross-section sensitivities to a parameter of interest (such as k eff ), a gap analysis to determine which existing benchmarks are most similar to the application, and an experiment optimization. Recently, there has been a great deal of interest in the reactor physics community on advanced reactors, micro reactors, and accelerator driven systems (ADS). This work will apply the described method to specific examples in this area. The focus of this work will be on the sensitivity study and gap analysis, while future work will include experiment design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep-Learning-Derived Evaluation Metrics Enable Effective Benchmarking of Computational Tools for Phosphopeptide Identification

Tandem mass spectrometry (MS/MS)-based phosphoproteomics is a powerful technology for global phosphorylation analysis. However, applying four computational pipelines to a typical mass spectrometry (MS)-based phosphoproteomic dataset from a human cancer study, we observed a large discrepancy among the reported phosphopeptide identification and phosphosite localization results, underscoring a critical need for benchmarking. While efforts have been made to compare performance of computational pipelines using data from synthetic phosphopeptides, evaluations involving real application data have been largely limited to comparing the numbers of phosphopeptide identifications due to the lack of appropriate evaluation metrics. We investigated three deep learning-derived features as potential evaluation metrics: phosphosite probability, Delta RT and spectral similarity. Predicted phosphosite probability is computed by MusiteDeep, which provides high accuracy as previously reported; Delta RT is defined as the absolute retention time (RT) difference between RTs observed and predicted by AutoRT; and spectral similarity is defined as the Pearson’s correlation coefficient between spectra observed and predicted by pDeep2. Using a synthetic peptide dataset, we found that both Delta RT and spectral similarity provided excellent discrimination between correct and incorrect peptide-spectrum matches (PSMs) both when incorrect PSMs involved wrong peptide sequences and even when incorrect PSMs were caused by only incorrect phosphosite localization. Based on these results, we used all the three deep learning-derived features as evaluation metrics to compare different computational pipelines on diverse set of phosphoproteomic datasets and showed their utility in benchmarking performance of the pipelines. The benchmark metrics demonstrated in this study will enable users to select computational pipelines and parameters for routine analysis of phosphoproteomics data and will offer guidance for developers to improve computational methods.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha Analysis of CURIE Experiment

Critical assembly measurement and operations are crucial to the development of benchmark data to support research into criticality safety, radiation-detection development, and the overall application of nuclear technologies. Accurate nuclear data are needed for accurate predictive simulations, and validation using critical experiments is an important part of the nuclear data pipeline. The accuracy of nuclear data are improved using more robust and targeted measurements. In particular, the intermediate energy range of uranium is of great interest. LANL has successfully performed the Zeus series of experiments on the Comet assembly to investigate the intermediate energy range for HEU with various moderators. A successor to these experiments is the benchmark for the Critical Unresolved Region Integral Experiment (CURIE), designed to be sensitive to the unresolved resonance region (URR). This experiment is designed using polytetrafluoroethylene, more commonly known as Teflon, moderators. The CURIE experiment was successfully conducted at the National Criticality Experiments Research Center (NCERC). The Rossi-alpha method was used to evaluate the propensity of the CURIE configurations to sustain fission chains by estimating the prompt neutron decay constant α. This work evaluates the α at delayed critical using Rossi-alpha for different Teflon moderator thicknesses in the CURIE experiment. These results will help improve understanding of the CURIE benchmark experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a New Fixed-source Sensitivity Tally Capability in the MCNP ® Code [Slides]

Current work includes FSEN capability development, continued verification of adjoint-weighted sensitivity method, and improvement of algorithm speed and parallelism capability. Future work is forecasted to include extensions to non-Boltzmann responses, adding more responses and particle types, and connection to new MCNP6.3 tally backend.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VALID Past, Present, and Future [Slides]

This presentation discusses the Verified, Archived Library of Inputs and Data (VALID) procedure which is managed per computational procedure under the overall SCALE quality assurance plan. The principle behind VALID is that two independent, qualified people prepare and review the model, while a dual, independent check acts as a primary barrier to prevent errors in the library. A final check by VALID QAC of procedural compliance is then performed. The future for VALID includes plans to add more experiments, a review for all ICSBEP cases containing Deuterium, ZEUS intermediate and fast spectrum evaluations, intermediate enrichment experiments, other cases of interest to sponsors, and mixed/intermediate spectrum experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Gadolinium Validation in SCALE 6.3.0 using ENDF/B-VIII.0 Data [Slides]

This presentation provides a brief recap of the ANS Summer meeting in 2018 with a discussion of the results. The presentation also provides an overview of new models and states that all new models have been checked but have not yet been added to the VALID library. It also states that the models were originally created as part of a master's thesis or summer internships. Additionally, all models have been rerun in SCALE 6.3.0 using CE ENDF/B-VIII.0 library. In conclusion, this project has facilitated a significant expansion of validation set containing gadolinium, including 13 cases previously in VALID plus 99 new cases. The completion of IPPE HST experiments confirm no clear trend as a function of concentration or spectrum. Solid absorber cases also show no clear trends and LANL HMT experiments have significant discrepancies in Gd alloy cases. While almost half of the total gadolinium-bearing cases from the ICSBEP Handbook are considered here, the presentation recognizes that there is more work to be done.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proposed Methodology for Evaluating and Validating TSLs [Slides]

This presentation begins by providing an overview of the research and discusses recent efforts in validating thermal neutron scattering cross sections, including differential cross section measurements at ORNL for evaluation and validation, total cross section measurements at RPI, pulsed-neutron die-away experiments at LLNL, and integral criticality experiments by LLNL. The presentation also proposes a methodology not only for validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on polystyrene. In conclusion, polystyrene evaluation was conducted using multiple experiments, including differential and integral. The proposed methodology has been shown to improve neutron transport and files have been submitted to NNDC for inclusion in ENDF/B-VIII.1 release. MCT-012 & PCM-002 has been relatively insensitive to changes in $\mathcal{S}(α,β)$. The research found that differences in differential results don’t always propagate to differences in integral results, hence why evaluation of differential data important. Future work on the project is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation [Abstract]

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗