Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “critical loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Ares I-X Upper Stage Simulator Residual Stress Analysis

The structural analyses described in the present report were performed in support of the NASA Engineering and Safety Center (NESC) Critical Initial Flaw Size (CIFS) assessment for the Ares I-X Upper Stage Simulator (USS) common shell segment. An independent assessment was conducted to determine the critical initial flaw size (CIFS) for the flange-to-skin weld in the Ares I-X Upper Stage Simulator (USS). The Ares system of space launch vehicles is the US National Aeronautics and Space Administration s plan for replacement of the aging space shuttle. The new Ares space launch system is somewhat of a combination of the space shuttle system and the Saturn launch vehicles used prior to the shuttle. Here, a series of weld analyses are performed to determine the residual stresses in a critical region of the USS. Weld residual stresses both increase constraint and mean stress thereby having an important effect on fatigue and fracture life. The results of this effort served as one of the critical load inputs required to perform a CIFS assessment of the same segment.

Raju, Ivatury S.↗

The Effect of Initial Displacement of the Center Support on the Buckling of a Column Continuous over Three Supports

The test indicate that "an indiscriminate single application of the Southwell method (for analyzing Exp. Observations in problems of elastic stability)--can result in definite and measurable errors" The test also indicate "that the effect of curvature due to bending on the critical load for the compression flange material of a box beam is probably small and can be neglected." We have not found this to be true in our tests. It is believed that the effect of curvature, together with a small amount of fixity at the ribs, tends to force the stiffeners to bow in each bay thus effectively increasing their end fixity and thereby raising their allowable loads.

Lunquist, Eugene E.↗

Dynamic Structural Fault Detection and Identification

Aircraft structures are designed to guarantee safety of flight in some required operational envelope. When the aircraft becomes structurally impaired, safety of flight may not be guaranteed within that previously safe operational envelope. In this case the safe operational envelope must be redefined in-flight and a means to prevent excursion from this new envelope must be implemented. A specific structural failure mode that may result in a reduced safe operating envelope, the exceedance of which could lead to catastrophic structural failure of the aircraft, will be addressed. The goal of the DFEAP program is the detection of this failure mode coupled with flight controls adaptation to limit critical loads in the damaged aircraft structure. The DFEAP program is working with an F/A-18 aircraft model. The composite wing skins are bonded to metallic spars in the wing substructure. Over time, it is possible that this bonding can deteriorate due to fatigue. In this case, the ability of the wing spar to transfer loading between the wing skins is reduced. This failure mode can translate to a reduced allowable compressive strain on the wing skin and could lead to catastrophic wing buckling if load limiting of the wing structure is not applied. The DFEAP program will make use of a simplified wing strain model for the healthy aircraft. The outputs of this model will be compared in real-time to onboard strain measurements at several locations on the aircraft wing. A damage condition is declared at a given location when the strain measurements differ sufficiently from the strain model. Parameter identification of the damaged structure wing strain parameters will be employed to provide load limiting control adaptation for the aircraft. This paper will discuss the simplified strain models used in the implementation and their interaction with the strain sensor measurements. Also discussed will be the damage detection and identification schemes employed and the means by which the damaged aircraft parameters will be used to provide load limiting that keeps the aircraft within the safe operational envelope.

Smith, Timothy↗

Inconsistencies in Sulphur Dioxide Emissions from the Canadian Oil Sands and Potential Implications

Satellite-derived and reported sulfur dioxide (SO2) emissions from the Canadian oil sands are shown to have been consistent up to 2013. Post-2013, these sources of emissions data diverged, with reported emissions dropping by a factor of two, while satellite-derived emissions for the region remained relatively constant, with the discrepancy (satellite-derived emissions minus reported emissions) peaking at 50 kt(SO2) yr−1 around 2016. The 2013–2014 period corresponds to when new flue-gas desulfurization units came on-line. Previous work has established a high level of consistency between at-stack SO2 emissions observations and satellite estimates, and surface monitoring network SO2 concentrations over the same multi-year period show similar trends as the satellite data, with a slight increase in concentrations post-2013. No clear explanation for this discrepancy currently exists. The implications of the discrepancy towards estimated total sulfur deposition to downwind ecosystems were estimated relative to 2013 emissions levels, with the satellite-derived values leaving the area of regional critical load exceedances of aquatic ecosystems largely unchanged from 2013 values, 335 000 km2, and reported values potentially decreasing this area to 185,000 km2.

Sulphur dioxide (SO2) emissions↗

High Temperature Material Property Data and Challenges to Thermal Process Model Predictions and In-Situ/Ex-Situ Measurements for Metallic Additive Manufacturing

Understanding and predicting performance properties of parts produced by metallic additive manufacturing has improved significantly over the past decade; however, difficult to measure material properties and process outcomes continue to be challenges. The qualification or certification of aerospace parts require extensive measures to quantify variable part properties in order to buy down the risk of component failure. The variability, inherent to the additive manufacturing, process adds unwanted uncertainty in the production of load critical structural components. Process modeling has proven valuable in providing predictions and context for understanding outcomes of the additive manufacturing process; however, these physically informed process models require material properties at temperatures that are difficult to measure and rarely available. Further, calibrating or validating such models is difficult because the process itself is challenging to measure. This talk will explore some of the challenges resulting from difficult to acquire input data by relating thermal process model predictions to in-situ and ex-situ optical microscopy measurements.

Process Model↗

Thermal Systems Modeling of Chemical Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such as system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90-100 Wth thermal power and 30-40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Thermal Systems Modeling of Chemical Heat Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such a system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90 to 100 Wth thermal power and 30 to 40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Evaluate Distributed Energy Technologies for Cost Savings and Resilience With REopt Lite

NREL's REopt Lite TM web tool evaluates the economics of grid connected photovoltaics (PV), wind, and battery storage at a site. It allows users to identify the system sizes and battery dispatch strategy that minimize a site's life cycle cost of energy, and it estimates the amount of time a PV, wind, battery, and diesel generator system can sustain the site's critical load during a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning: Preprint

Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-the-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVALUATING FACILITY ENERGY EFFICIENCY AND RESILIENCE OPPORTUNITIES WITH FEDS AND MCOR

Energy resilience has become increasingly important for critical building infrastructure, in response to concerns over potential disruptions to the electrical grid from threats both natural and man-made. Energy efficiency can provide a valuable resource for reducing critical loads and therefore lowering the cost of supplying alternative power. This paper highlights two tools that are well-suited for analyzing building energy efficiency and resilience opportunities and presents a case study for their combined application. The Facility Energy Decision System (FEDS) and Microgrid Component Optimization for Resilience (MCOR) tools can be used together to simulate building systems, identify energy efficiency measures, and evaluate resilience options for powering a site during an outage.

FEDS, MCOR, Energy Efficiency, Resilience, Simulat↗

Integrating the Value of Resilience into Energy Decisions

The value of resilience can be quantified and integrated into decision making to help inform economic, resilient, and sustainable energy deployment decisions using tools and analysis. Traditionally, distributed energy deployment decisions have often been based on how much energy, or how much money, a system can save. More and more, building owners and communities are recognizing that these systems can also provide a resilience value by sustaining critical loads during an outage. In order to consider the value of resilience in investment decisions, we must quantify how much resilience a system provides, assign a value to that resilience, and monetize that value through grid services, incentives, or other methods. This presentation discusses methods, tools, advantages, and challenges inherent to the process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning

Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

System and method for implementing a zero-sequence current filter for a three-phase power system

In a three-phase, four-wire electrical distribution system, a zig-zag transformer and at least one Cascade Multilevel Modular Inverter (CMMI) is coupled between the distribution system and the neutral. A controller modulates the states of the H-bridges in the CMMI to build an AC waveform. The voltage is chosen by the controller in order to control an equivalent impedance that draws an appropriate neutral current through the transformer. This neutral current is generally chosen to cancel the neutral current sensed in the line. The chosen neutral current may be based on a remotely sensed imbalance, rather than on a local value, determined by the power utility as a critical load point in the system. The desired injection current is then translated by the controller into a desired zero-sequence reactive impedance, based on measurement of the local terminal voltage, allowing the controller to regulate the current without generating or consuming real power.

Benavides, Nicholas↗

NREL: Working Towards a Superlab 2.0 With ESnet and Other National Laboratories

We can currently link models and simulations across the national laboratory complex, but imagine connecting these models with equipment, devices, and scientists so they can work together as if side by side instead of thousands of miles apart. In a future like this, researchers could run experiments that leverage thousands of devices to model the millions of devices that make up our increasingly complex energy systems. With such resources, labs could simulate, for example, the electric grid of California and validate control strategies to best serve critical loads during outages caused by wildfires. The National Renewable Energy Laboratory's (NREL's) Advanced Research on Integrated Energy Systems (ARIES) platform is making that vision a reality, one step at a time.

ARIES↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

The U.S. Department of Energy (DOE) has launched a Connected Communities program that supports projects that expand DOE's network of grid-interactive, efficient building communities nationwide. As an early pilot of Connected Communities, the National Renewable Energy Laboratory (NREL) and its partners have developed and demonstrated a community-scale, hierarchical control solution to address the potential grid issues arising from high penetration of solar photovoltaics (PV) as well as to improve grid reliability and resilience in this residential community. A field pilot study has been performed at an affordable housing development called the Basalt Vista Community, which was built for school teachers and other professionals in the local workforce and represents an autonomous energy grid with all-electric, energy-efficient homes. With no natural gas line in the community, this is the first all-electric net-zero community in rural Colorado. In the field pilot study, NREL has validated the performance of the hierarchical control solution, which consists of NREL's foresee home energy management systems (HEMS) and community aggregators, in increasing demand flexibility and self-consuming PV, reducing potential over-voltages, and supporting critical loads during emergency events. In this presentation, we will present the methodology, simulation and field pilot results, and lessons learned from the project.

all-electric community↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗