Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Efficient data reduction for time-of-flight neutron scattering experiments on single crystals

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Impact of Dimensionality Reduction of Ion Counts Distributions on Preserving Moments, With Applications to Data Compression

The field of space physics has a long history of utilizing dimensionality reduction methods to distill data, including but not limited to spherical harmonics, the Fourier Transform, and the wavelet transform. Here, we present a technique for performing dimensionality reduction on ion counts distributions from the Multiscale Mission/Fast Plasma Investigation (MMS/FPI) instrument using a data-adaptive method powered by neural networks. This has applications to both feeding low-dimensional parameterizations of the counts distributions into other machine learning algorithms, and the problem of data compression to reduce transmission volume for space missions. The algorithm presented here is lossy, and in this work, we present the technique of validating the reconstruction performance with calculated plasma moments under the argument that preserving the moments also preserves fluid-level physics, and in turn a degree of scientific validity. The method presented here is an improvement over other lossy compressions in loss-tolerant scenarios like the Multiscale Mission/Fast Plasma Investigation Fast Survey or in non-research space weather applications.

D. da Silva↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Neutron detection using Poisson distribution comparison independent of count rate based on correlation signals

Embodiments are directed to comparison-based methods of conditionally assessing the excess in correlation of an unknown neutron count measurement compared to the correlation present in a data defined as background, and to providing a technical definition of excess correlation intended to properly handle the measured excess correlation. The degree of correlation between an unknown source and background can be used to prevent masking of neutron count data for the source by background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium glow detector experiment, MA-088

Of the two 584 A channels in the helium glow detector, channel #1 appeared to provide data with erratic count rates and undue susceptibility to dayglow and solar contamination possibly because of filter fatigue or failure. Channel #3 data appear normal and of high quality. For this reason only data from this last channel was analyzed and used for detailed comparison with theory. Reduction and fitting techniques are described, as well as applications of the data in the study of nighttime and daytime Hel 584 A emission. A hot model of the interstellar medium is presented. Topics covered in the appendix include: observations of interstellar helium with a gas absorption cell: implications for the structure of the local interstellar medium; EUV dayglow observations with a helium gas absorption cell; and EUV scattering from local interstellar helium at nonzero temperatures: implications for the derivations of interstellar medium parameters.

Bowyer, C. S.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Population statistics of faint stellar and non-stellar objects

A disc and halo population model is constructed to fit star counts and color data down to V approximately 23 at absolute value of b = 90 deg. This model is used to predict star counts and colors down to V approximately 30. Deviations from these extrapolated relationships provide constraints on the number of faint quasars and black dwarf stars. It is shown that extra-galactic globular clusters start contributing significantly to star counts at V approximately 25 and are more numerous than stars for V 31. Morphological studies of galaxies with approximately 0.5, were made with the space telescope. Significant constraints on theoretical models that describe the evolution of clusters of galaxies are provided.

Vandenbergh, S.↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Application of the Tasseled Cap concept to simulated thematic mapper data

Thematic Mapper signal counts in the six reflective bands (i.e., excluding the thermal band) are simulated using field and laboratory spectrometer measurements of a variety of crops, crop conditions, and soil types. The Dave atmospheric model and prelaunch sensor characteristics comprise the other components of the simulation. The simulated data are found to occupy essentially three dimensions, two of which are equivalent to the MSS Tasseled Cap Greennes and Brightness features, and a third which is substantially influenced by the mid-infrared bands of the TM. This new dimension is primarily related to soil characteristics, including soil moisture. The nature and characteristics of each dimension are discussed, as are some of the expected information gains (over MSS data) resulting from the additional dimensionality of the data.

Crist, E. P.↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Neutral point detection by satellites

The concept of a neutral point depends on the physical phenomena described. The regions with B less than about 1 gamma detected by Schindler and Ness may be interpreted as neutral regions for the ion-tearing process. The assumption of the presence of a multiple neutral point structure (with temporal variations) is still the most promising interpretation of the Explorer 34 data. Alternatives suggested by Russell lead to difficulties. Nevertheless, the final answer can come only from multiple satellite systems. A 1-day displacement of the day count in the data discussed by Schindler and Ness is corrected.

Schindler, K.↗

PROBING NUCLEAR DYNAMICS IN REAL-PHOTON EXPERIMENTS

Experimental results on the reactions ?d ? ?0d, ?d ? pn, ?3He ? ppn, and ?3He ? pd obtained in Hall B at Jefferson Lab at photon energies between 0.3 and 3.0 GeV are discussed. The goal of the measurements is to study the transition between long- and short-range nuclear dynamics, as well as more specific dynamical effects, such as manifestations of three-body mechanisms. Conventional nuclear models can describe the data up to a momentum transfer of ~ 1 (GeV/c)2. All the studied reactions on deuterium clearly show scaling properties consistent with the predictions of the Constituent Counting Rules. The data on 3He suggest that the favorable energy range for the study of three-body mechanisms is 0.6 - 0.8 GeV.

ILIEVA, YORDANKA↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractal Dimension Calculation for Big Data Using Box Locality Index

The box-counting approach for fractal dimension calculation is scaled up for big data using a data structure named box locality index (BLI). The BLI is constructed as key-value pair style with the key (an integer array) indexing the location of a “box” (i.e., a gird cell on the multi-dimensional space embedding a given dataset) and the value counting the number of data points inside the box (called “box occupancy”). Compared with the traditionally used E-dim tree, the BLI avoids complex hierarchical structure and encodes only necessary information required by box-counting approach for fractal dimension calculation. Moreover, the key-value pair nature of BLI, together with the fact that the box occupancy is aggregatable, grants box-counting approach the needed scalability for fractal dimension calculation of big data using distributed computing techniques (e.g., MapReduce and Spark). Taking the advantage of the BLI, MapReduce and Spark methods for fractal dimension calculation of big data are developed, which conduct box-counting for each grid level as a cascade of MapReduce/Spark jobs in a bottom-up fashion. In an empirical validation, the MapReduce and Spark methods demonstrated good effectiveness and efficiency in fractal calculation of a big synthetic dataset. In summary, this work provides an efficient solution for the estimation of intrinsic dimension of big data that is essential for many machine learning methods and data analytics.

Fractal dimension, Intrinsic dimension, Box-counti↗