Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners

Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner from the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ActiveBAS: A Low-cost, Scalable Control Solution for Grid-Interactive Small and Medium Sized Commercial Buildings

This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability analysis of model-free control under constrained inputs for control of building HVAC systems

Recently introduced model-free control method has witnessed successful applications in various domains. While the framework of model-free control renders it simple and efficient, it imposes difficulties in implementing the method for complex applications under external constraints. Moreover, there is a lack of literature on the study and application of model-free control under constrained environments. This paper attempts to further the study of model-free control by employing it for monitoring indoor temperature of buildings through the control of building heating, ventilation and air conditioning (HVAC) system and studying the control design stability conditions under constrained inputs. Two kinds of constraints on the control input are considered and their stability conditions are investigated. The developed framework aims to highlight a potential path to analyze the stability under a given set of constraints. The results of employing model free control on the building HVAC system under unconstrained and constrained inputs are presented. The role of the model estimation error on the stability is also discussed.

Telsang, Bhagyashri↗

Diabetes-specific formula with standard of care improves glycemic control, body composition, and cardiometabolic risk factors in overweight and obese adults with type 2 diabetes: results from a randomized controlled trial

Background and aims Medical nutrition therapy is important for diabetes management. This randomized controlled trial investigated the effects of a diabetes-specific formula (DSF) on glycemic control and cardiometabolic risk factors in adults with type 2 diabetes (T2D). Methods Participants ( n = 235) were randomized to either DSF with standard of care (SOC) (DSF group; n = 117) or SOC only (control group; n = 118). The DSF group consumed one or two DSF servings daily as meal replacement or partial meal replacement. The assessments were done at baseline, on day 45, and on day 90. Results There were significant reductions in glycated hemoglobin (−0.44% vs. –0.26%, p = 0.015, at day 45; −0.50% vs. −0.21%, p = 0.002, at day 90) and fasting blood glucose (−0.14 mmol/L vs. +0.32 mmol/L, p = 0.036, at day 90), as well as twofold greater weight loss (−1.30 kg vs. –0.61 kg, p < 0.001, at day 45; −1.74 kg vs. –0.76 kg, p < 0.001, at day 90) in the DSF group compared with the control group. The decrease in percent body fat and increase in percent fat-free mass at day 90 in the DSF group were almost twice that of the control group (1.44% vs. 0.79%, p = 0.047). In addition, the percent change in visceral adipose tissue at day 90 in the DSF group was several-fold lower than in the control group (−6.52% vs. –0.95%, p < 0.001). The DSF group also showed smaller waist and hip circumferences, and lower diastolic blood pressure than the control group (all overall p ≤ 0.045). Conclusion DSF with SOC yielded significantly greater improvements than only SOC in glycemic control, body composition, and cardiometabolic risk factors in adults with T2D.

Tey, Siew Ling↗

Skylab attitude control and angular momentum desaturation with one double-gimbaled control moment gyro

In case two control moment gyros fail, attitude control of Skylab can be maintained with the thruster attitude control system. This results, however, in a severely increased fuel consumption, depleting the fuel in a few days. Therefore, an alternate concept was developed which does not have large fuel consumption under any circumstances. In this concept the attitude reference is commanded to oscillate in the orbital plane with twice the orbital frequency and the remaining control moment gyro controls about orbital north and about the minimum moment-of-inertia axis, while the thruster attitude control system controls rate only about the remaining axis. This rate control in conjunction with the restoring torque due to the gravity gradient will keep bounded the excursion of the minimum moment-of-inertia axis out of the orbital plane. This alternate concept has the additional advantage that it needs no information on the principal moment-of-inertia axes misalignment and is completely insensitive to star tracker failure. Proper phasing of the attitude reference oscillation even allows angular momentum desaturation, which is responsible for the insensitivity of the thruster fuel consumption to unknown disturbances, like vent torques and magnetic torques.

Kennel, H. F.↗

Evaluation of control laws and actuator locations for control systems applicable to deformable astronomical telescope mirrors

Some of the major difficulties associated with large orbiting astronomical telescopes are the cost of manufacturing the primary mirror to precise tolerances and the maintaining of diffraction-limited tolerances while in orbit. One successfully demonstrated approach for minimizing these problem areas is the technique of actively deforming the primary mirror by applying discrete forces to the rear of the mirror. A modal control technique, as applied to active optics, has previously been developed and analyzed. The modal control technique represents the plant to be controlled in terms of its eigenvalues and eigenfunctions which are estimated via numerical approximation techniques. The report includes an extension of previous work using the modal control technique and also describes an optimal feedback controller. The equations for both control laws are developed in state-space differential form and include such considerations as stability, controllability, and observability. These equations are general and allow the incorporation of various mode-analyzer designs; two design approaches are presented. The report also includes a technique for placing actuator and sensor locations at points on the mirror based upon the flexibility matrix of the uncontrolled or unobserved modes of the structure. The locations selected by this technique are used in the computer runs which are described. The results are based upon three different initial error distributions, two mode-analyzer designs, and both the modal and optimal control laws.

Ostroff, A. J.↗

Lagged low order control systems with powered controls

With powered controls, a high order control system can be changed to a lower order control system with a lag, which is better suited to our position control skills and strategies. Separate groups of untrained men were trained on an acceleration control system, or on a rate control system with an exponential lag of either .5, 2, or 4 sec. Acquisition time was reliably shorter with all the lagged rate control systems than with the unlagged acceleration control system.

Poulton, E. C.↗

The optimal control frequency response problem in manual control

An optimal control frequency response problem is defined within the context of the optimal pilot model. The problem is designed to specify pilot model control frequencies reflective of important aircraft system properties, such as control feel system dynamics, airframe dynamics, and gust environment, as well as man machine properties, such as task and attention allocation. This is accomplished by determining a bounded set of control frequencies which minimize the total control cost. The bounds are given by zero and the neuromuscular control frequency response for each control actuator. This approach is fully adaptive, i.e., does not depend upon user entered estimates. An algorithm is developed to solve this optimal control frequency response problem. The algorithm is then applied to an attitude hold task for a bare airframe fighter aircraft case with interesting dynamic properties.

Harrington, W. W.↗

Pilot control through the TAFCOS automatic flight control system

The set of flight control logic used in a recently completed flight test program to evaluate the total automatic flight control system (TAFCOS) with the controller operating in a fully automatic mode, was used to perform an unmanned simulation on an IBM 360 computer in which the TAFCOS concept was extended to provide a multilevel pilot interface. A pilot TAFCOS interface for direct pilot control by use of a velocity-control-wheel-steering mode was defined as well as a means for calling up conventional autopilot modes. It is concluded that the TAFCOS structure is easily adaptable to the addition of a pilot control through a stick-wheel-throttle control similar to conventional airplane controls. Conventional autopilot modes, such as airspeed-hold, altitude-hold, heading-hold, and flight path angle-hold, can also be included.

Wehrend, W. R., Jr.↗

Multicyclic control of a helicopter rotor considering the influence of vibration, loads, and control motion

Weighted multiple linear regression is used to establish a transfer function matrix relationship between higher harmonic control inputs and transducer vibration outputs for a controllable twist rotor. Data used in the regression were taken from the test of a KAMAN controllable twist rotor conducted in the Ames Research Center's 40- by 80-Foot Wind Tunnel in June 1977. Optimal controls to minimize fixed system vibrational levels are calculated using linear quadratic regulatory theory with a control deflection penalty included in the performance criteria. Control sensitivity to changes in control travel, forward speed, and lift and propulsive forces is examined. It is found that the linear transfer matrix is a strong function of forward speed and a weak function of lift and propulsive force. An open-loop strategy is proposed for systems with limited control travel.

Brown, T. J.↗

Control of large space structures using Annual Momentum Control Devices (AMCD's)

A controller design approach for large space structures, which proposes the use of several Annular Momentum Control Devices (AMCD's) for structural damping enhancement, and either torque actuators of AMCD's for primary attitude control, was investigated. The damping enhancement controller makes the system asymptotically stable under certain relatively simple conditions. The closed-loop stability of the system with the primary attitude controller as well as the overall controller was established. It is shown that the same AMCD's can be used for the actuation of the damping enhancement controller and the primary attitude controller. Numerical results were obtained for a finite-element model of a large, thin, completely free, flat aluminum plate.

Joshi, S. M.↗

F100 Multivariable Control Synthesis Program. Computer Implementation of the F100 Multivariable Control Algorithm

As turbofan engines become more complex, the development of controls necessitate the use of multivariable control techniques. A control developed for the F100-PW-100(3) turbofan engine by using linear quadratic regulator theory and other modern multivariable control synthesis techniques is described. The assembly language implementation of this control on an SEL 810B minicomputer is described. This implementation was then evaluated by using a real-time hybrid simulation of the engine. The control software was modified to run with a real engine. These modifications, in the form of sensor and actuator failure checks and control executive sequencing, are discussed. Finally recommendations for control software implementations are presented.

Soeder, J. F.↗

Road load simulator tests of the Gould phase 1 functional model silicon controlled rectifier ac motor controller for electric vehicles

The test results for a functional model ac motor controller for electric vehicles and a three-phase induction motor which were dynamically tested on the Lewis Research Center road load simulator are presented. Results show that the controller has the capability to meet the SAE-J227a D cycle test schedule and to accelerate a 1576-kg (3456-lb) simulated vehicle to a cruise speed of 88.5 km/hr (55 mph). Combined motor controller efficiency is 72 percent and the power inverter efficiency alone is 89 percent for the cruise region of the D cycle. Steady state test results for motoring, regeneration, and thermal data obtained by operating the simulator as a conventional dynamometer are in agreement with the contractor's previously reported data. The regeneration test results indicate that a reduction in energy requirements for urban driving cycles is attainable with regenerative braking. Test results and data in this report serve as a data base for further development of ac motor controllers and propulsion systems for electric vehicles. The controller uses state-of-the-art silicon controlled rectifier (SCR) power semiconductors and microprocessor-based logic and control circuitry. The controller was developed by Gould Laboratories under a Lewis contract for the Department of Energy's Electric and Hybrid Vehicle program.

Gourash, F.↗

Evaluation of the aerodynamic control of the Space Shuttle orbiter and tip-fin controllers

A feasibility study to assess the benefits/penalties of installing tip-fin controllers on the Space Shuttle orbiter has been conducted. The results from the aerodynamic and stability and control assessment of this study are presented. These results show that using tip-fin controllers with the centerline vertical tail removed provides adequate control for entry. The orbiter basic maneuvering capability is maintained, and symmetrical deflection of the controllers provides adequate speedbrake authority for energy management. Gust analyses of the orbiter with the tip-fin controller configuration have demonstrated no compromise of existing cross-wind landing capability. Six-degree-of-freedom simulations have shown the tip-fin controllers can provide adequate control for entry with no degradation in vehicle capability.

Powell, R. W.↗

A comparison of active vibration control techniques - Output feedback vs optimal control

The paper presents analytical and experimental comparison of two control laws for a laboratory structure designed to simulate large space structures. The first control law is the standard linear quadratic law, which is optimal but requires model reduction for practical implementation. The second control law is a new simple direct feedback control law designed to minimize control forces while guaranteeing stability. The optimal control law was found to be only slightly better than the direct feedback law even in terms of the quadratic performance index. Moreover, the optimal control law provided almost no margin of stability for the unmodeled modes while the direct feedback law provided significant stability margins to all modes. The above results were verified experimentally using a digital implementation of the control laws. Excellent agreement between the analytical prediction and experimental measurements was observed.

Martinovic, Zoran N.↗

Investigation of practical applications of H infinity control theory to the design of control systems for large space structures

The applicability of H infinity control theory to the problems of large space structures (LSS) control was investigated. A complete evaluation to any technique as a candidate for large space structure control involves analytical evaluation, algorithmic evaluation, evaluation via simulation studies, and experimental evaluation. The results of analytical and algorithmic evaluations are documented. The analytical evaluation involves the determination of the appropriateness of the underlying assumptions inherent in the H infinity theory, the determination of the capability of the H infinity theory to achieve the design goals likely to be imposed on an LSS control design, and the identification of any LSS specific simplifications or complications of the theory. The resuls of the analytical evaluation are presented in the form of a tutorial on the subject of H infinity control theory with the LSS control designer in mind. The algorthmic evaluation of H infinity for LSS control pertains to the identification of general, high level algorithms for effecting the application of H infinity to LSS control problems, the identification of specific, numerically reliable algorithms necessary for a computer implementation of the general algorithms, the recommendation of a flexible software system for implementing the H infinity design steps, and ultimately the actual development of the necessary computer codes. Finally, the state of the art in H infinity applications is summarized with a brief outline of the most promising areas of current research.

Irwin, R. Dennis↗