At least 271 records · Page 15

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Managing the techno-economic impacts of partial string failure in multistring energy storage systems

The role of energy storage systems (ESSs) is becoming increasingly important for today’s electric power systems. Unavailability of an ESS assigned to critical grid services may cause unwanted disruption of those services and hence, may have a significant techno-economic impact. Like any physical equipment, an ESS is vulnerable to various types of faults. Failure of one or more strings in a multistring ESS does not have to be the cause of shutting down the entire ESS. It can still operate with a partial number of strings and continue providing critical services to the grid, if there are no reliability or safety issues and is acceptable under applicable standards. However, it is important to make sure that the control strategies are adaptable to the changes in ESS capacity caused by failed strings. Also, depending on the previous operation and type of failure, the reallocation of duty cycle burden among available strings could be non-uniform. These complexities suggest that mitigation of the impact of partial failure in multistring ESSs is not trivial and needs careful consideration. This is the topic of this paper. The proposed work investigates the impact of partial failure of a large multistring ESS on the assigned service and develops strategies to adjust the ESS control duty cycles for reducing such impacts. In doing so, the paper proposes a novel two-stage framework that plans for the multistring failure using robust optimization theory and then adjusts in real-time using a rule-based algorithm, based on the real-time information on the power availability of the string. Illustrations provided in this work are based on frequency regulation use-case, which is a common application for many utility-scale ESSs. A 750 kilowatt (kW)/1500 kilowatt-hour (kWh) 3-string ESS is used for the demonstration in this work and the efficacy of the proposed method is demonstrated and compared against methods that do not incorporate string failure in their strategy. In particular, here we show that revenue loss of 93% can be incurred when partial string failure is not included in operation and planning. These losses in revenue are reduced by 60% with the proposed method.

25 ENERGY STORAGE↗

Autonomous control for Heat-Pipe microreactor using Data-Driven model predictive control

To enable a self-regulating capability for heat pipe (HP) microreactors, an anticipatory control strategy achieved via model predictive control (MPC) could proactively respond to potential disturbances and deviations in operating setpoints. This paper demonstrates data-driven methods for predicting the distribution and transient of temperatures and heat fluxes at selected components and regions in a 37-HP system, based on which the optimal control actions in response to changes in user-defined setpoints can be found. We present the development and validation of linear state-space model, feedfoward, and recurrent neural networks. Here, we compare the performance of MPCs with different modeling approaches in terms of following setpoints for temperatures and averaged output heat fluxes. The accuracies of the three data-driven models are similar, but the control actions initiated by neural-network-based MPC can better adapt to drastic changes in setpoints yet generate the smallest errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-driven key performance indicators and datasets for building energy flexibility: A review and perspectives

Energy flexibility, through short-term demand-side management (DSM) and energy storage technologies, is now seen as a major key to balancing the fluctuating supply in different energy grids with the energy demand of buildings. This is especially important when considering the intermittent nature of ever-growing renewable energy production, as well as the increasing dynamics of electricity demand in buildings. This paper provides a holistic review of (1) data-driven energy flexibility key performance indicators (KPIs) for buildings in the operational phase and (2) open datasets that can be used for testing energy flexibility KPIs. The review identifies a total of 48 data-driven energy flexibility KPIs from 87 recent and relevant publications. These KPIs were categorized and analyzed according to their type, complexity, scope, key stakeholders, data requirement, baseline requirement, resolution, and popularity. Moreover, 330 building datasets were collected and evaluated. Of those, 16 were deemed adequate to feature building performing demand response or building-to-grid (B2G) services. The DSM strategy, building scope, grid type, control strategy, needed data features, and usability of these selected 16 datasets were analyzed. This review reveals future opportunities to address limitations in the existing literature: (1) developing new data-driven methodologies to specifically evaluate different energy flexibility strategies and B2G services of existing buildings; (2) developing baseline-free KPIs that could be calculated from easily accessible building sensors and meter data; (3) devoting non-engineering efforts to promote building energy flexibility, standardizing data-driven energy flexibility quantification and verification processes; and (4) curating and analyzing datasets with proper description for energy flexibility assessm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning-based ethylene and carbon monoxide estimation, real-time optimization, and multivariable feedback control of an experimental electrochemical reactor

Electrochemical reduction of CO 2 gas is a novel CO 2 utilization technique that has the potential to mitigate the global climate crisis caused by anthropogenic CO 2 emissions, and enable the large-scale storage of energy generated from renewable sources in the form of carbon-based chemicals and fuels. However, due to the complexity of the electrochemical reactions, the explicit first-principles models for CO2 reduction are not available yet, and there has been a limited effort to develop process modeling, optimization and control of CO 2 electrochemical reactors. To this end, a rotating cylinder electrode (RCE) reactor has been constructed at UCLA to understand the mass transfer and reaction kinetics effects separately on the productivity. In the RCE reactor, the applied potential strongly influences the reaction energetics and the electrode rotation speed affects the hydrodynamic boundary layer and modifies the film mass transfer coefficient, which involves convective and diffusive transport. Further, the present work aims to develop a multi-input multi-output (MIMO) control scheme for the RCE reactor that integrates techniques from artificial and recurrent neural network modeling, nonlinear optimization, and process controller design. Specifically, production rates of two products from the experimental reactor, ethylene and carbon monoxide, are controlled by manipulating two inputs, applied potential and catalyst rotation speed. Process dynamics and controllability are analyzed, a feedback control strategy is designed and the controllers are tuned accordingly. The experimental electrochemical cell is employed to gather data for process modeling and implement the multivariable control system. Finally, the experimental results are presented which demonstrate excellent closed-loop performance by the control system and regulation of the outputs at three different set-points including an economically-optimal set-point.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pendant Group Modifications Provide Graft Copolymer Silicones with Exceptionally Broad Thermomechanical Properties

Graft copolymers offer a versatile platform for the design of self-assembling materials; however, simple strategies for precisely and independently controlling the thermomechanical and morphological properties of graft copolymers remain elusive. Here, using a library of 92 polynorbornene-graft-polydimethylsiloxane (PDMS) copolymers, we discover a versatile backbone-pendant sequence-control strategy that addresses this challenge. Small structural variations of pendant groups, e.g., cyclohexyl versus n-hexyl, of small-molecule comonomers have dramatic impacts on order-to-disorder transitions, glass transitions, mechanical properties, and morphologies of statistical and block silicone-based graft copolymers, providing an exceptionally broad palette of designable materials properties. For example, statistical graft copolymers with high PDMS volume fractions yielded unbridged body-centered cubic morphologies that behaved as soft plastic crystals. By contrast, lamellae-forming graft copolymers provided robust, yet reprocessable silicone thermoplastics (TPs) with transition temperatures spanning over 160 °C and elastic moduli as high as 150 MPa despite being both unentangled and un-cross-linked. Altogether, this study reveals a new pendant-group-mediated self-assembly strategy that simplifies graft copolymer synthesis and enables access to a diverse family of silicone-based materials, setting the stage for the broader development of self-assembling materials with tailored performance specifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New insights into the role of constitutive bacterial rhizobiome and phenolic compounds in two Pinus spp. with contrasting susceptibility to pine pitch canker

Abstract The rhizobiome is being increasingly acknowledged as a key player in plant health and breeding strategies. The pine pitch canker (PPC), caused by the fungus Fusarium circinatum, affects pine species with varying susceptibility degrees. Our aims were to explore the bacterial rhizobiome of a susceptible (Pinus radiata) and a resistant (Pinus pinea) species together with other physiological traits, and to analyze shifts upon F. circinatum inoculation. Pinus seedlings were stem inoculated with F. circinatum spores and needle gas exchange and antioxidant-related parameters were analyzed in non-inoculated and inoculated plants. Rhizobiome structure was evaluated through 16S rRNA gene massive parallel sequencing. Species (non-inoculated plants) harbored distinct rhizobiomes (<40% similarity), where P. pinea displayed a rhizobiome with increased abundance of taxa described in suppressive soils, displaying plant growth promoting (PGP) traits and/or anti-fungal activity. Plants of this species also displayed higher levels of phenolic compounds. F. circinatum induced slight changes in the rhizobiome of both species and a negative impact in photosynthetic-related parameters in P. radiata. We concluded that the rhizobiome of each pine species is distinct and higher abundance of bacterial taxa associated to disease protection was registered for the PPC-resistant species. Furthermore, differences in the rhizobiome are paralleled by a distinct content in phenolic compounds, which are also linked to plants’ resistance against PPC. This study unveils a species-specific rhizobiome and provides insights to exploit the rhizobiome for plant selection in nurseries and for rhizobiome-based plant-growth-promoting strategies, boosting environmentally friendly disease control strategies.

Leitão, Frederico↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

In-Situ Detection and Prediction of WAAM Cross Feature Geometry

Abstract Wire arc additive manufacturing (WAAM) is increasingly used by manufacturers due to its relatively low cost and high deposition rate compared to other metal AM methods, but the parts produced by WAAM can be subject to localized variations in part quality. One such variation is the cross-feature defect, whereby a localized part height increase occurs due to the crossing of deposition toolpaths. Mitigation of this defect is typically achieved using manual path planning strategies, but closed-loop control is underutilized. Since the nature of this defect and of the WAAM process is such that the previous layer’s geometry influences that of the subsequent layer’s, the cross-feature defect geometry changes throughout the deposition. Therefore, any closed-loop control strategy will need to incorporate the dynamic trait of this defect. The present work seeks to implement an in-situ process modeling approach where a regression model can be continuously updated to predict the defect geometry of the subsequent deposition layer based on the historical process data. Several multi-layer cross-feature geometries are deposited and current, voltage, and optical camera data is taken for each layer. The resulting cross-feature geometries are characterized using 3D scanning and the performance and accuracy of the in-situ modeling approach is evaluated.

Thien, Austen↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

Integrating Marine Hydrokinetic and Offshore Wind Energy: A Review of Technologies, Deployment, and Challenges

Together, offshore wind (OSW) and marine hydrokinetic (MHK) technologies have vast potential to expand the world’s access to abundant energy resource. With more than 60 GW of offshore wind energy capacity and 527 MW of ocean energy deployed globally by 2023, there is a significant amount of available resources; however, technical and non-technical challenges prevent the combined large-scale deployment of these technologies. There is still a lack of research that provides a parallel review of both MHK and OSW technologies in order to better understand their synergistic working principles. This paper aimed to address that research gap by presenting a comprehensive side-by-side review of the worldwide technological landscape, global deployment trends, integration strategies, and modeling approaches for MHK and OSW. A particular focus has been given on analyzing existing modeling and simulation techniques, assessing integration and control strategies, and comparing technologies based on water depth. Furthermore, this study provides important insights into the readiness levels of both technologies by highlighting ongoing international projects. By addressing these issues, this review will give researchers and industry stakeholders an outline for assessing the maturity of OSW and MHK systems and facilitating their transition to large-scale, sustainable deployment.

16 - TIDAL AND WAVE POWER↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Per-Phase Control for CHB Converters with Negative-Sequence Current and DC Voltage Balancing Control

This paper presents a per-phase controller for a grid-connected Cascaded H-Bridge (CHB) converter featuring negative sequence current regulation and DC bus voltage balancing capabilities. Unlike conventional three-phase controllers, each phase of the CHB can be separately and controlled to regulate the DC voltage and reactive power flow. per-phase negative sequence current control strategy is incorporated into the proposed controller to ensure compliance with IEEE Standard 2800-2022, which requires the absorption of negative-sequence reactive current during grid voltage disturbances. Furthermore, a feed-forward control-based DC bus voltage balancing method is employed, which eliminates the need for the integrator commonly used in traditional approaches. The performance of the proposed controller is validated under various unbalanced grid scenarios and DC bus voltage imbalances through electromagnetic transient (EMT) simulation using a three-phase, three-level grid-connected CHB–Dual Active Bridge (DAB) converter testbed developed on MATLAB/Simulink. Additionally, the performance of the negative-sequence current regulation is investigated through simulation under different unbalanced grid voltage scenarios.

negative sequence current↗

Transforming Aeration Energy in Water Resource Recovery Facilities (WRRFs) through Suboxic Nitrogen Removal (Final Report)

The objective of this project was to advance two key technological components—aeration control strategies and process design methodologies—to support the development and broader adoption of suboxic biological nitrogen removal (SBNR). The project focused on achieving the following three goals: • Enhance Model Predictive Control (MPC) Technology: Advance the DO/Nmaster MPC platform from its initial 2018 pilot deployment at the Chico Water Resource Recovery Facility in California to full-scale integration. This included partnering with a blower technology commercialization partner and incorporating machine learning (ML) capabilities to enable nationwide deployment. • Bridge Knowledge Gaps in SBNR Process Design: Address fundamental gaps in SBNR process understanding through controlled pilot-scale testing at a dedicated pilot facility. These efforts supported the development of robust kinetic models to inform reliable SBNR control, operational strategies, and design frameworks. • Demonstrate Full-Scale Implementation of Low DO/SBNR with ML: Transition low dissolved oxygen (DO)/SBNR coupled with ML from pilot-scale trials to full-scale demonstration in flow-through biological nutrient removal (BNR) systems, with the goal of enabling scalable, nationwide adoption in activated sludge treatment processes. The project included demonstration of SBNR at the pilot scale as performed by Hampton Roads Sanitation District (HRSD) and at the full-scale as performed by the Los Angeles County Sanitation Districts' (LACSD) Pomona Water Reclamation Plant (POWRP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human-Machine Shared Control for Path Following Considering Driver Fatigue Characteristics

Fatigue driving has been regarded as one of the most important factors that cause traffic accidents. This paper proposes a robust human-machine shared control strategy to improve the vehicle performance for different driver fatigue states. Firstly, the time-varying driver steering model is proposed to address the model mismatch caused by fatigue driving. And the driver fatigue evaluation system is established based on facial features to quantify driver fatigue levels. Based on the quantified fatigue levels, a novel strategy for allocating authorities of the driver and controller is developed for building the driver-vehicle interaction system. Then, to weaken the influence of parameter perturbations caused by the time-varying driver states, we design a fatigue-based shared controller through state feedback. The actuator saturation and system constraints are considered in the controller design through the robust set-invariance property to improve vehicle safety and driving comfort. The driver-in-the-loop platform is conducted to validate the effectiveness of the proposed shared steering controller. In conclusion, the experimental results show that the proposed strategy can adaptively optimize the human-machine authorities according to fatigue states and comprehensively improve vehicle performance.

97 MATHEMATICS AND COMPUTING↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗