Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Identification of multiloop pilot describing functions obtained from simulated approaches to an aircraft carrier

Predicted results of a simulation of the pilot's approach control strategy in the presence of pilot remnant are presented. The aircraft dynamics and the turbulence environment are representative of a trainer-type aircraft. The non-intrusive pilot identification program (NIPIP) was used to identify the pilot's control strategy required by this highly-coupled, multiloop control task. The results are presented in terms of frequency responses of the individual elements of the pilot's control strategy and indicate that NIPIP can identify the pilot's describing functions even in the presence of significant amounts of pilot remnant.

Jewell, W. F.↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

Model Predictive Control-Based Dual-Mode Operation of an Energy-Stored Quasi-Z-Source Photovoltaic Power System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations with simple structure and other advantages of Z-source inverter. The improved dual-mode (DM) ES-qZSI is able to support all-weather operation even at night or cloudy days when PV power is extremely low. However, the traditional proportional–integral (PI) based control suffers from complicated controller design and poor dynamic response during mode transition, due to two sets of PI control required for the daytime and night operation modes. In order to overcome that, here in this article, we propose a model predictive control strategy for the DM-ES-qZSI PV power system. The system predictive models in both day and night operating modes are derived. The control strategy is disclosed to ensure high performance of the system, through calling the predictive models and defined cost functions of the two modes within a single control loop. Simulation and experiment are carried out to verify the effectiveness of the proposed control strategy.

14 SOLAR ENERGY↗

Network-Wide Traffic Signal Control Using Bilinear System Modeling and Adaptive Optimization

This study proposes a new multi-input multi-output optimal bilinear signal control method in which a bilinear dynamic model approximation is used to capture the nonlinear dynamics of the urban traffic networks. With signal green time splits as the control input and traffic delay changes as the output for each intersections in the network, a bilinear system model was developed, which, on the basis of linear system modeling, takes interactions among traffic delays and signal timing splits into consideration. Based on the bilinear system modeling framework, we conducted two steps in each time interval to derive traffic control strategies: (1) we used the normalized least-squared algorithm to estimate system parameters; and (2) we solved an online optimization problem to obtain the updated traffic control inputs for the signal timing that minimizes future traffic delays. We evaluated the proposed method in a microscopic traffic simulation environment (VISSIM) with a 35-intersection network of Bellevue city in Washington. Two different traffic demand patterns: (1) normal traffic demands; and (2) time-varying traffic demands were simulated to compare the performance of different control strategies. Experimental results show that (1) the proposed bilinear system model can better describe traffic system dynamics than linear-model based methods, such as our previously developed linear-quadratic regulator control; and (2) the proposed method outperforms the state-of-the-art signal control strategies, namely the max-pressure and the self-organizing traffic light control methods. We have also shown that the proposed method is applicable to all other possible network layouts and signal controller phasing structures.

42 ENGINEERING↗

Advanced Stirling Radioisotope Generator (ASRG) Thermal Power Model in MATLAB

This paper presents a one-dimensional steady-state mathematical thermal power model of the ASRG. It aims to provide a guideline of understanding how the ASRG works and what can change its performance. The thermal dynamics and energy balance of the generator is explained using the thermal circuit of the ASRG. The Stirling convertor performance map is used to represent the convertor. How the convertor performance map is coupled in the thermal circuit is explained. The ASRG performance characteristics under i) different sink temperatures and ii) over the years of mission (YOM) are predicted using the one-dimensional model. Two Stirling converter control strategies, i) fixing the hot-end of temperature of the convertor by adjusting piston amplitude and ii) fixing the piston amplitude, were tested in the model. Numerical results show that the first control strategy can result in a higher system efficiency than the second control strategy when the ambient gets warmer or the general-purpose heat source (GPHS) fuel load decays over the YOM. The ASRG performance data presented in this paper doesn't pertain to the ASRG flight unit. Some data of the ASRG engineering unit (EU) and flight unit that are available in public domain are used in this paper for the purpose of numerical studies.

Wang, Xiao-Yen, J.↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Learning to Control Advanced Life Support Systems

Advanced life support systems have many interacting processes and limited resources. Controlling and optimizing advanced life support systems presents unique challenges. In particular, advanced life support systems are nonlinear coupled dynamical systems and it is difficult for humans to take all interactions into account to design an effective control strategy. In this project. we developed several reinforcement learning controllers that actively explore the space of possible control strategies, guided by rewards from a user specified long term objective function. We evaluated these controllers using a discrete event simulation of an advanced life support system. This simulation, called BioSim, designed by Nasa scientists David Kortenkamp and Scott Bell has multiple, interacting life support modules including crew, food production, air revitalization, water recovery, solid waste incineration and power. They are implemented in a consumer/producer relationship in which certain modules produce resources that are consumed by other modules. Stores hold resources between modules. Control of this simulation is via adjusting flows of resources between modules and into/out of stores. We developed adaptive algorithms that control the flow of resources in BioSim. Our learning algorithms discovered several ingenious strategies for maximizing mission length by controlling the air and water recycling systems as well as crop planting schedules. By exploiting non-linearities in the overall system dynamics, the learned controllers easily out- performed controllers written by human experts. In sum, we accomplished three goals. We (1) developed foundations for learning models of coupled dynamical systems by active exploration of the state space, (2) developed and tested algorithms that learn to efficiently control air and water recycling processes as well as crop scheduling in Biosim, and (3) developed an understanding of the role machine learning in designing control systems for advanced life support.

Subramanian, Devika↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Control of nonlinear systems with applications to constrained robots and spacecraft attitude stabilization

This thesis is organized in two parts. In Part 1, control systems described by a class of nonlinear differential and algebraic equations are introduced. A procedure for local stabilization based on a local state realization is developed. An alternative approach to local stabilization is developed based on a classical linearization of the nonlinear differential-algebraic equations. A theoretical framework is established for solving a tracking problem associated with the differential-algebraic system. First, a simple procedure is developed for the design of a feedback control law which ensures, at least locally, that the tracking error in the closed loop system lies within any given bound if the reference inputs are sufficiently slowly varying. Next, by imposing additional assumptions, a procedure is developed for the design of a feedback control law which ensures that the tracking error in the closed loop system approaches zero exponentially for reference inputs which are not necessarily slowly varying. The control design methodologies are used for simultaneous force and position control in constrained robot systems. The differential-algebraic equations are shown to characterize the slow dynamics of a certain nonlinear control system in nonstandard singularly perturbed form. In Part 2, the attitude stabilization (reorientation) of a rigid spacecraft using only two control torques is considered. First, the case of momentum wheel actuators is considered. The complete spacecraft dynamics are not controllable. However, the spacecraft dynamics are small time locally controllable in a reduced sense. The reduced spacecraft dynamics cannot be asymptotically stabilized using continuous feedback, but a discontinuous feedback control strategy is constructed. Next, the case of gas jet actuators is considered. If the uncontrolled principal axis is not an axis of symmetry, the complete spacecraft dynamics are small time locally controllable. However, the spacecraft attitude cannot be asymptotically stabilized using continuous feedback, but a discontinuous stabilizing feedback control strategy is constructed. If the uncontrolled principal axis is an axis of symmetry, the complete spacecraft dynamics cannot be stabilized. However, the spacecraft dynamics are small time locally controllable in a reduced sense. The reduced spacecraft dynamics cannot be asymptotically stabilized using continuous feedback, but again a discontinuous feedback control strategy is constructed.

Krishnan, Hariharan↗

Hybrid Electric Aircraft with Unlike Engine Degradation

Control solutions are applied to uneven engine performance degradation on a conceptual twin-engine transport-class aircraft. Such degradation can lead to asymmetric thrust, which requires rudder trim to maintain desired aircraft heading. This will increase drag and fuel consumption. With the introduction of hybrid-electric aircraft powertrains, new solutions to unwanted asymmetric thrust can be derived. Four control strategies are demonstrated on the power and propulsion system of such an aircraft. Compared with existing strategies, the methodology proposed in this paper controls electromechanical actuators coupled to engine shafts and balances the thrust produced by both engines potentially leading to a decrease in fuel burn. The engine represented in this study is NASA’s conceptual dual-shaft Advanced Geared Turbofan 30,000 lbf thrust class engine. The conceptual engine is hybridized with electric machines attached to both shafts. Simulation results are presented with various levels of degradation. The control strategies are compared based on fuel burn, thrust symmetry, and estimated system weight.

control↗

Hybrid Electric Aircraft with Unlike Engine Degradation

Control solutions are applied to uneven engine performance degradation on a conceptual twin-engine transport-class aircraft. Such degradation can lead to asymmetric thrust, which requires rudder trim to maintain desired aircraft heading. This will increase drag and fuel consumption. With the introduction of hybrid-electric aircraft powertrains, new solutions to unwanted asymmetric thrust can be derived. Four control strategies are demonstrated on the power and propulsion system of such an aircraft. Compared with existing strategies, the methodology proposed in this paper controls electromechanical actuators coupled to engine shafts and balances the thrust produced by both engines potentially leading to a decrease in fuel burn. The engine represented in this study is NASA’s conceptual dual-shaft Advanced Geared Turbofan 30,000 lbf thrust class engine. The conceptual engine is hybridized with electric machines attached to both shafts. Simulation results are presented with various levels of degradation. The control strategies are compared based on fuel burn, thrust symmetry, and estimated system weight.

control↗

Multifidelity multiobjective optimization for wake-steering strategies

Abstract. Wake steering is an emerging wind power plant control strategy where upstream turbines are intentionally yawed out of perpendicular alignment with the incoming wind, thereby “steering” wakes away from downstream turbines. However, trade-offs between the gains in power production and fatigue loads induced by this control strategy are the subject of continuing investigation. In this study, we present a multifidelity multiobjective optimization approach for exploring the Pareto front of trade-offs between power and loading during wake steering. A large eddy simulation is used as the high-fidelity model, where an actuator line representation is used to model wind turbine blades and a rainflow-counting algorithm is used to compute damage equivalent loads. A coarser simulation with a simpler loads model is employed as a supplementary low-fidelity model. Multifidelity Bayesian optimization is performed to iteratively learn both a surrogate of the low-fidelity model and an additive discrepancy function, which maps the low-fidelity model to the high-fidelity model. Each optimization uses the expected hypervolume improvement acquisition function, weighted by the total cost of a proposed model evaluation in the multifidelity case. The multifidelity approach is able to capture the logit function shape of the Pareto frontier at a computational cost only 30 % that of the single-fidelity approach. Additionally, we provide physical insights into the vortical structures in the wake that contribute to the Pareto front shape.

17 WIND ENERGY↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Magnetohydrodynamics (MHD) Aerocapture System for Enabling Faster-Larger Planetary Science & Human Exploration Missions

Since our completing the NIAC Phase I NIAC on this Advanced Aerocapture System, NASA Langley Research Center has funded or supported a number of studies and code enhancements through its Center Innovation Fund (CIF) and NASA’s NSTGRO and Internship Programs to mature the analysis capabilities and quantify the merits of the MHD Aerocapture System technology. These efforts have resulted in a plug and play analysis capability for assessing MHD aerocapture system performance for arrival at many planetary bodies of interest. Our efforts have especially focused on the potential mass savings for improving the capacity for science observations at Neptune and Triton. A re-cent Forbes article published “‘Orbital mechanics is probably going to decide for us whether we go to Uranus or Neptune because we need to flyby Jupiter,’ said Kunio Sayanagi at Hampton University, Virginia, who also worked on the Neptune Odyssey proposal…. Exactly when a mission can be sent to Uranus, or Neptune, depends on the relative position of Jupiter, which can help give a spacecraft a gravitational slingshot. That drastically shortens the cruise phase.” [1] Since shortening the cruise phase is important for these science missions, any mass savings enabled by the MHD Aerocapture System could be reallocated to increasing Thermal Protection System mass to allow faster arrival speeds and/or for onboarding additional payloads such as science instruments, batteries, or propellant for conducting more science for longer durations in the desired orbits. The analysis steps and codes for conducting trades and sizing vehicles for aerocapture are as follows: Step 1 is to conduct aeroheating analysis using LAURA of the selected entry vehicle shape to identify locations on the forebody where ionization and flow velocity are sufficient for producing Lo-rentz forces. LAURA is a multiblock structured grid finite-volume CFD solver developed at the NASA Langley Research Center. [2] LAURA has been used for aerothermal analysis support of the entry, de-scent and landing (EDL) phase of interplanetary missions over the last three decades [3-7]. Step 2 is to port the LAURA results into CFDWARP to calcu-late electrical and thermal conductivities of ionized flow for sizing MHD patch system and calculating Lorentz forces needed for controls analysis. CFDWARP is a CFD code that uses advanced nu-merical methods that enable the simulation of the full coupling between the aerodynamics, the magne-tohydrodynamics, and the non-neutral plasma sheaths. CFDWARP has the unique capability to simulate efficiently the non-neutral sheaths (near the electrodes) in coupled form with the quasi-neutral bulk MHD flow [8-11]. Step 3 is to link re-sults from LAURA and CFDWARP into POST2 for calculating entry trajectories and comparing MHD control results with other aerodynamic control strategies. The Program to Optimize Simulated Tra-jectories II (POST2) is a generalized point mass, discrete parameter targeting and optimization pro-gram. POST2 provides the capability to target and optimize point mass trajectories for multiple pow-ered or un-powered vehicles near an arbitrary rotat-ing, oblate planet [12]. Step 4: TPS sizing was per-formed using the Fully Implicit Ablation and Ther-mal-response code (FIAT) tool which computes the transient one-dimensional thermal response and surface thermochemistry of a multilayer stackup of thermal protection, bonding, and structural materi-als subject to aeroheating on one surface [13]. The sizing and margining methodology used was based on the approach documented by Mahzari and Milos [14] for the dual-layered heatshield for extreme entry environment technology (DL-HEEET) TPS concept. TPS analysis utilizes trajectory information from POST2. Using this step-wise plug and play MHD Aerocapture performance assessment process, our analysis targets a Neptune aerocapture trajectory that will place the spacecraft in an observation orbit for Triton. [15]. Magnetohydrodynamic (MHD) control of a 4.5-meter diameter MSL-style capsule resulted in TPS mass savings of nearly 2000 kg when using an MHD system mass of under 200 kg. The flight path for a vehicle using the MHD control strategy has a much lower heat rate and heat load compared to the conventional aerodynamic aerocapture strategies known as bank angle con-trolled (BAC) and direct force controlled (DFC). Both BAC and DFC have heat rates significantly greater than 1500 W/cm2 typically used as an upper limit for PICA. Thus, DL-HEEET TPS concept was required for the BAC and DFC control strategies. However, considering the more benign environ-ments for the MHD case, additional TPS concepts with improved mass efficiency were also assessed. PICA was considered for the MHD controlled strat-egy since the maximum heat rate was well within the limits (<1500 W/cm2) of PICA. TPS sizing re-sulted in a significant mass reduction. The PICA layer for this sizing case was about 7.8 cm. As a point of reference, the Mars 2020 mission, which used this same PICA concept, had a PICA thickness of 3.18 cm [16]. The trajectories used for the TPS sizing originat-ed from the POST2 simulations. The current, I, to an electromagnet configuration can be manipulated to allow for active control of the vehicle. Manipula-tion of the current, I, changes the magnetic field, B, which affects the Lorentz force and therefore the MHD drag force on the vehicle. Our analysis in-cluded both open-loop and close-loop control. Closed-loop control will enable improved overall performance when taking into account mission level uncertainties, such as interplanetary delivery errors and atmospheric modeling uncertainties. The open-loop and closed-loop MHD control cases do not dip as deep into the atmosphere as the aerodynamic cases. Three types of aerodynamic-only approach-es are investigated: bank angle modulation (BAM), director force control (DFC), and Drag Modulated. BAM and DFC make use of vehicle aerodynamic angles to steer the vehicle. Thus, changing the aer-odynamic forces acting on the vehicle for control, aerodynamic drag modulated case requires a vary-ing drag area to modulate the drag force. The MHD drag modulated case modulates MHD generated drag force that adds to the aerodynamic drag. This higher atmospheric activation of drag forces by the MHD patch results in significantly less heat flux on the vehicle. The MHD technology will enable shorter cruise times and deceleration of larger payloads for increasing the capacity for science at the Ice Giants or for returning astronauts to Earth from cislunar space or from Mars. The purpose of this presentation is to provide more details about this work and to highlight plans for further research and development including a flight demonstration.

R. W. Moses↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗